window air conditioner Not Cooling ice Problem Solution (Urdu Hindi)
ฝัง
- เผยแพร่เมื่อ 19 เม.ย. 2019
- is video mein ap doston ko window air conditioner ke cooling ko thek Karne Ka Tarika kar bataun ga aur yah bhi bataun ga ky ap window air conditioner ki ice ko Kaise Khatam kar sakte hain
#windowAirconditioner
#ice - วิทยาศาสตร์และเทคโนโลยี
Bai sahib 12000 btu ka 1:5 ton hota hai 1200 ka nahi
12000 btu ka 1 ton hota ha bhai g 1.5 nhi hota ap kia answer kar rahe hain #ajengineering
1.5 ton me 18000 btu hota ha bhai
Yes 12000 Btu 1 ton
18000 Btu 1.5 ton
24000 Btu 2 ton
Ap kahan sy ho
12000 BTU = 1 TON
18000 BTU = 1.5 TON
24000 BTU = 2 TON
30000 BTU = 2.5 TON
36000 BTU = 3 TON
وعلیکم السلام ورحمت اللہ وبرکاتہ
زبردست
بہت اچھی معلوماتی ویڈیو بنای ہے آپ نے
Thanks
Mashallah zabardat information sir
Thanks #ajengineering
Nice video aapka video bahut achcha lagata hai up se
Thanks #ajengineering ❤️
Good Information Dear...👍
Thank you
Masha Allah super all videos useful
Thanks & welcome #ajengineering
Good information
Right information
Walikum Asslam bhai app bahut mast kam kar tai hu
Thanks #ajengineering
Bhai compreshar hit kyo hota he
Hit hone ke baad 20.25 minat me chalu hota he
Walaikum assalam Bhai
Me what'sapp0966599768807 #ajengineering
Aslam o alikum apna WhatsApp number send
9649941662 . Add me Bhaijaan
Walaikum salam bhai
💔
Good work
Assalaam mualaikum bhai..... Bhai mere pas super general window AC hai 1.5 ton ka..... 6 months hua hai purchase karke but Abhi 15 din se kuch khaas cool Nahi karraha hai..... Aur Jahan se Hawa aati hai us ke neeche ek Chota sa button diya hai wo kis pe rakhna hai... Off ya on
Button on karo grill ka button hota hai grill ko Upar niche karne ke liye room ka size big to nahin hai aur Jis Jagah ap ne AC Lagaya hia Ap na acche se AC ko pack Kiya hua hai Bahar Wali Garmi Hawa andar To Nahin a Rah check karo Aur din Ko thand Nahin Karta K Raat Ko
Bhai mera ek lg ka Window a/c same problem getting ice in pipe and showing ahmp high mechanic bola comperser change kero . Reply plz
gas check करवाए
Ac bhee woo ac jiska Naam bhee nahee very good
Thanks #ajengineering
Thnx bro
❤️
Good video
Walekum Assalam wa rahamatullahi wa barkathu
Thanks #ajengineering
Same problem in my ac
Bro kis window AC me temperature 15 show krta h
Nice video
Thanks
Nice
Thanks #ajengineering
10 mpr jaida hai tumahre gas thodi kam kr ya fan condeser fan speed. Check kr 8 se 8.5 amp.set kr 1.5 ton AC ke
Thanks #ajengineering
walequm assalam bhai
💔
Very nice video
Thanks #ajengineering
پیارے بھائی ڈیرھ ٹن 18000 BTU کا ھوتا ھے نہ کہ 1800 کا
Ji hum dekh sakte h 😜😍🤣😃
Window AC ka grill temperature perfect 12 hota hy na k 18 ya 20
Heat load ke hisab se temperature kam Jyada Hota rahata hai #ajengineering
Hlo sir Kya aap mujhe ek baat bta skte ho. Mere pass ek split AC hai jiska indoor unit grab ho gya hai Kya meh uska indoor unit change krva du toh vo outdoor unit se match ho jayga kya
Bhai ap ka Kan sa Ac ha R22 gas Hai #ajengineering
Good
Thanks #ajengineering
Good🇨🇦🇨🇦
Thanks
Bhai jan window 1.5 ton k ac main agar rotary R410 laga dain to kya ye work kari ge or kitnay amp reduce hon gay
Window R22 gas Mein R22 gas wala hi compressor Laga sakte hain #ajengineering
simply
Sir mere ac ke kuwail mai bi bahut ice aa rahi aa kahi compressor ka pressure to kam nahi ja gas problems
Ni thurmostate badal do
Leake test karo with nitrogen
Sir agar tanda pani ac k indoor unit me pump k zarye pass kare tho cooling milegi k nahi.. (out door unit ki zaroorat nahi rahegi).. Pls guide kare..
Je bilkul Aisa ho sakta hai iske liye ap ko Hi fan ki zarurat hai. #ajengineering
G bilkul indoor working condition me rahegi.. (fan chalega)... Mere khyal me agar 4 room ka ghar ho tho 1 freezer aur 1 pump se control hojayenge. (freezer se indoor k suction pe pump k through water pass kare. Aur discharged se second pipe k through freezer me return kare..
Water cool coil ho gi to mile ge split window ac kay coil mag water cool system nhi ho skta
@@UsmanKhan-cf6mp AHU main..child Water saply hota bo kaise hota hain.. Sir please reply
Sir mera Volta's split Ac outdoor unit me exhaust fan on karnese kabi kabi chal raha he kuch 2,3 ghante chalne ke bad automatic ban hotahe kya problem. Kabi kabi on hote hi chalu nehi hotahe .problem bataie sir
Assalamalekum bhaijaan
Meri ac me barf jama ho rahi hai cooling kam karti hai pani nahi fekti hai peeche se kia problem ho sakti hai
Alaikum assalam warahmatullahi wabarkatullah
Song by uncle bedroom anime and bacon casserole the blue what is another me about paragraph but i'm back down again i have asked me about others edinburgh
Bhai Jan ap Saudia me Hotay ho
Replay me
Asslamu alycom sir window ac hetar ke dare rahate.
Walaykumassalam,sir ji agar split ac me indoor ki input line me ice aa rahi hai aur gas preesure pahele 30 psi tha aur thodi der baad 50 psi ho gaya aur standing pressure 130psi tha tau kya sir is ac me capillary chowk ho sakti hai ya kuchh aur please help me
Is ki gas thoori barha do ap thik hojae ga
Agar back pressure differ hota rehta hai jaise 30 psi FIR 50 psi Ho Gaya aur FIR kam ho gaya to bahut jyada chances hai ki capillary partial choke ho sakti hai ya strainer block ho sakta hai iske liye chahiye ki capillary aur strainer ko change karen system ko dry nitrogen se flush kiya jaye acchi tarah aur FIR vacuum karke gas recharge kiya jaye gas top up karne wala idea useless hai.
Zamil ac not Collings what do you think
Kia sath sath seiling fan chala sakty hain
Suction लाइन पर गर्म महसूस होता है या ठंडा
Sir Meri window AC kharab hai Chalte Chalte a pressure chhutti hai ka kya issue hai please reply
Sir mera ac back se garm air nahi nikalta thodi si cool air niklata hai .Window ac ha 1 ton ka kya problem ho sakti hai aur cooling bi kam karta hai pls help me
Tehi problem mere ac jo 2 ton ka hai------
Window ac m 1.5 ton r22 gas ka charge kitna hota h sir
Dear sir , Ac k liye kon si company gas ki achi hoti hai
USA ki gas #ajengineering
Gas dubara dalni padti h Kya bro
mery a c b cooling sahi nahi cooling karta . tell me the solution
meri ac me stand pressure 170 psi h or back pressure 15 psi h or amp. 8 le rhaa h cooling nhi ho rhi or ice bhi aayi huyi h 2 pipe pr
bhai kha pr phli baat usme gees hii nhi he aor he to sarves mang rha he chek kro use
Bhai Mujay Lagta hai ap Saudia me Hotay ho
Ma B Saudia me Hota hwo
Ap kaha hotay ho
Ma B ye hi kaam karta hwo
966597762540
Reply me
00966580636050
bhai Agar leakage Nahin Hai Fir Bhi aisa hai to kya problem ho sakti hai
Hlo sir mena apsa ek bat pushni hai ki mena gas fill grayi laki ac temp 17 nikal raha hai usna waqum b kiya tha ap bat sakta hai kya problem hai
gas ka Gas ka suction pressure kitna hai
Mery pas jo window ac hy us me ye problem hy k wo starting me ice show krwata hy bad me slowly slowly khatm ho jati hy
Or colling b km hy kia issue hy
AC ki gas check karo aur AC ki service karo
Mera Hitachi ka ac h iski coil puri thandi nahi hoti sirf 8 ya 9 coil hi thandi hoti he cooling main bhi koi jyada kam nahi karty kya problam ho sakti he
Ap Ac Ki service karao aur gas check karo #ajengineering
Bhai ye batao mera window ac me compressor chal rha hai par aage evaporater coils me cooling nhi ho rhi, kewal 1 saal purana voltas ac hai, kya wajah ho sakti hai???
Gas check karo #ajengineering
Aise hi mere ac mein quil ki side barf jam rahi h Kya ye hi problem ho sakti h bro
Gas Chakra Ac k service karo #ajengineering
bhai mere pass 9000 btu window ac hai 10 ×10 room mai laga hai or wo colling sai nai kar raha hai b new .compny ki tarf se jo amp hai 4.sy 7 hai or wo amp bhi 4 le raha hai. plz kuch bata dije
bhai usme gees chek kra lo
Sab comments ko "love" karte ho ? Kyun..
Capillary par ice formation. Ka Matlab hai short supply of liquid refrigerant. Aur wo ho sakta hai choke ya gas leak ki kaaran. Agar ampere constant hai to gas leak hai aur ampere fluctuate karta hai toh capillary ya strainer choke hai.
Ye basic daignostic rule hai.
Gas charging karne see pehle pressure test bhi karna hota hai. Pressure test toh nahi kiya, ek leak ko hi confirm maan liya.
Grill temperature ka Matlab hai return air temperature. Aap ne Jahan thermometer laga wo through temperature.
Educational videos dhyan se banane chahiye,
Thanks #ajengineering
Gas charge hoti h kya
Mery waly ac main hawa nahi a rahi plz btao kasy theek hoga
Apmr to sahi. Hai 6
G ❤️
Bhai sahab ji mera window ac sahi hone ke bad bhi cooling sahi nhi de raha me isme pehle hi kafi paise laga chuka hun muje kya karna chahiye
Yar mera ac 10 din cooling krta hai our bad men thori thori cooling krta hai yar kia kron boht se Ac cheng kar k dekha hai plzz koi Hal bta dy
Super
Thanks #ajengineering
i think new technician
Thanks #ajengineering
Sir ek ac h cool Kar rhe h but Ampear bahut Kam le rhe h 1.5 ten ka splet h
Gas check Karo #ajengineering
ice aa rhi thi tab iska stand pressure kitna tha
Eska course kaha hota hai sri
Aap katna chahate hai ac ka kaam
Sir Aj Engineering Me Job Milega Ham Dubai me Job karte hai Ac ka
Hi
Bhai compressor k discharge pipe line main U turn kyu diya jata hai ?
agar compressor fail hota hai toh uska oil discharge line mai chala jata hai aur maintenance main usse change karna padta hai isliye u turn lagane se oil zyada fehlta nahi hai aur aap sirf u turn tak cut karke uska maintenance easy aur cost saving tarikhe se karsakte ho
اسلام علیکم جناب کیسے ہو جناب ھم نے وینڈو اے سی ایک جگہ سے دوسرے جگہ پر رکیں ابھی وہ کولنگ نہیں کرتی کیا کریں کچھ طریقہ بتاؤ
Thanks #ajengineering
Mechanic kitna paise leta h ye problem thik karne ke
Is problem ke mechanic kitne paise charge karta h
Red button ka kya work h
Kitna paisa lagta h gas filup krna me
1500
Aslamalakum
W Salam ❤️
Ac thand nahi karraha hai keya Hal hai
Mere pass ek windows ac aaiya hai go ki usme cooling coil ka 2 pipe cool karta hai full cooling nahi karta hai
back pressor 175
Running pressor 75
AC proper service karo #aj engineering
@@Ajengineering proper service kar diye hai
Or Colling coil bhi saf he or air thoro bhi thik he gas bhi thik he.phir ice Q a rahe he
Thermostat check karo
18.000 BTU 1.5 ton hota hai. AAP galat bol rahe ho 1800 BTU
thermostat kase check kare
Video upload karun ga #ajengineering
Ac ka kam malum hai
AP ko #ajengineering
Sir mere Ac m hawa nhi de rha h kya kru
blower chal Raha hai ke nahi
App khaka ho bhai sap
G Pakistan se #ajengineering
Bhai BTU 18.000 hai 1800 so nhi hai
likeage hotahe Toh evaporator pe borof zom jatahe ,,
Borof Ha na acha se check karo video #ajengineering
Aj engineering apko buhut buhut shukriya kye ke apko hortime comment ka reply kaartahe😍😍😍😘love you much engeneer
Aj engineering mera name yad rakhna he kye ke me apko channel subscribe kiya✌bidio achha banaya ga hortime comment karega ) frome Bangladesh
Welcome bro #ajengineering
Ok Thanks no problem #ajengineering
Video to thik hai lekin aap ne kaise gas nikali kaise vacuum kia fir kaise dubara gas bhari es bare mai kush nahi btaya jo ke main baat thi sir.
Ok Naxt video Mein
@@Ajengineering Jaldi bnao Next video.
Ok Thanks #ajengineering
Pleasebhai batana Jarur
Hava kasa dekha bhai
Hi
12.000 BHT k 1 ton hota hai bhai
ALLAH k bandey tum information share kro ye jo tarikaaa bata rahe ho ghar per kon kr skta hai thora to dimag se kaam lo ...
Ok sir
Bhai gas kaam hai
Es video me vacuum kaise kiye gass kase nikala ye sab to dikhate nhi ho.samjh kahase aayegi.ap ka professional work hai koi value nhi rakhta dikhana but humlogo k liye har pahlu ko dekhna zaruri hota hai saheb.bahot sari video me Maine dekha hai k AP connection bhi karte huwey nhi dikhate hai videos pouse kardete hai fir wire pakar k dekhate hai this is not good.
Vacuum ke upar aur gas nikalne ke video ha channel me Ap ap watch kar lo #ajengineering
lts ok Bahi nat video Full Ho gi INSHALLAH 💔
Nrb lek the
I have try everything and my A.C. dont cool , it blows air but not cold?
1800 🤣🤣🤣