Air Conditioner not blowing cold air

แชร์
ฝัง
  • เผยแพร่เมื่อ 18 ก.ย. 2024
  • HVAC AIR CONDITIONING & REFRIGERATION ⎸ HOW TO FIX
    In this video I attend a Service Call and come across an Actron Air Air Conditioner displaying an E6 Fault. It turns out to be a gas leak that caused the fault. Watch on as I find the leak and get this unit back up and running.
    R410a Refrigerant.

ความคิดเห็น • 29

  • @sqracing
    @sqracing ปีที่แล้ว +2

    Mitch is a LEGEND.. these video helped me diagnose my on A/C and fix it.... THANKS MATE

  • @lwilliams3285
    @lwilliams3285 2 ปีที่แล้ว +1

    Love your work mate. Helps me a lot seeing your methods for fault finding and diagnosis after doing mostly install work my whole career.

  • @IrfanKhan-ks3sn
    @IrfanKhan-ks3sn 11 หลายเดือนก่อน +1

    AC nitrogen testing gas charging good work 👍👍

  • @locklyn9572
    @locklyn9572 ปีที่แล้ว +1

    Nice work mate ! Close liquid tap , open vapour and invert cylinder and you should get the last little bit out of the cylinder

  • @FreedomInMindtv
    @FreedomInMindtv 2 ปีที่แล้ว +1

    Nice one mate 👍🏻 I seen one of them stickers up centre point tower

  • @westindianhvac
    @westindianhvac 2 ปีที่แล้ว +1

    Never saw that Solenoid setup before I was here thinking why is it tripping like that if he weighed in factory charge , probably a bad pressure switch but then you said that's how the unit works that threw me off lol

    • @maracservices
      @maracservices  2 ปีที่แล้ว +1

      Yeah mate that’s definitely how they work. This particular unit isn’t an ‘Inverter’ as such, instead Actron Air use a Copeland Digital Scroll Compressor which apparently has its benefits. All day long these things make that noise and basically it’s just a solenoid valve taking the load off the compressor every few seconds. I can’t say I’m a massive fan of it but yeah that explains the noise 😂

  • @ashwinkumar3727
    @ashwinkumar3727 ปีที่แล้ว

    Hi mate love your videos. Are you based in Melbourne?

  • @syedbasheer8210
    @syedbasheer8210 2 ปีที่แล้ว +1

    👍👍👍

  • @atillakolik7321
    @atillakolik7321 ปีที่แล้ว

    Hi Mitch....love ur videos....i was hoping to pick your brain a bit.....i just had the same Esp platinum system installed.....the unit is much quiter than i expected......my issue is the vibration of the pipes inside the wall that create a buzzing/humming sound which can be felt/heard inside when the compressor kicks in.....have you ever come across this??....any recommendations on a solution to consider???

    • @SurRainbow
      @SurRainbow 9 หลายเดือนก่อน

      That’s normal when the compressor starts

  • @ashwinkumar3727
    @ashwinkumar3727 ปีที่แล้ว +2

    I have actron cooling. The condenser is not turning on. The fan is working I have checked all 3 capacitors all perfect. Would love your help. Happy to pay if you are in Melbourne

    • @maracservices
      @maracservices  ปีที่แล้ว

      Unfortunately, I am in Sydney however I’m happy to help any way I can.
      If you turn the Air Conditioner on, and walk outside and see the fans running but the compressor is not then I would be extremely confident that the soft starter is at fault. Actrons are well known for this fault unfortunately. However it’s an easy fix.

    • @ashwinkumar3727
      @ashwinkumar3727 ปีที่แล้ว

      Thanks for the advise Mitch. What reading should I get when testing to check. Your help would be so much appreciated

    • @ashwinkumar3727
      @ashwinkumar3727 ปีที่แล้ว

      Hi Mitch, on that softstart board there is a tiny red light flashing next to the blue wire. Your help would be truly appreciated

    • @ashwinkumar3727
      @ashwinkumar3727 ปีที่แล้ว

      Hi Mitch,
      I have made some progress as I checked the soft starter with multimeter neutral to Run winding and Neutral to Start winding it's showing OL
      Does that mean it's the Soft Starter? Thanks heaps in advance.

    • @maracservices
      @maracservices  ปีที่แล้ว

      @@ashwinkumar3727 You need to test the voltage in and out of the soft starter mate. Basically If there is power going into the soft starter but not coming out of the soft starter to the compressor then it’s the soft starter that’s faulty. Good luck

  • @tarekabuhijleh5638
    @tarekabuhijleh5638 6 หลายเดือนก่อน

    R410 charging is a liquid, not a gas

  • @Nazem.M
    @Nazem.M 7 หลายเดือนก่อน

    Hey Mate mine comes up with E9 code and when its too hot outside its doesnt turn the compressor on any ideas??

    • @cli_aus
      @cli_aus 6 หลายเดือนก่อน

      Hi Nazem, may I know how yours ends up fixing? I have the same issue E9 on a hot day😢

    • @Nazem.M
      @Nazem.M 6 หลายเดือนก่อน

      @charlieli8537 mine was the thermostat I'd say yours would be the same :)

  • @hendramulyawan9841
    @hendramulyawan9841 ปีที่แล้ว

    Mau i be your employee sir?