I would like to express my admiration for the exceptional work you do in the field of cool room design. Your God-gifted talent and expertise truly set you apart, and you have made a significant impact in this area.I believe your contributions have earned you recognition as a cool room expert, and I would love to learn more from your insights. If possible, could you kindly share a video showcasing your cool room designs? It would be greatly appreciated.
Bhai. Maine 404 ka expansion valve change krke. 22 gas ka expansion valve lagaya. Aur gas Bhi 22 charge kiya lekin - 18 tempreture nhi aa raha .oil seprator. Oil. Driyer. Bhi change kiya compressor pumping bhi ok hai fir bhi. - 13 se neeche nhi aa raha hai. Bhi kya problem ho sakta hai
Seplast freezer plastic body chemical wali ice creem freezer hai uska -23 se liche nahi ja rahi kya karu r404 gass hai customers ka kahana hai pure raat me 10 point tak hi charge hoti hai bas din bhar me -9 tak a jati hai ice creem pighalane lag jati hai
Bhai cold room temperature -13 ke niche jata nahi semi hermetic compressor hain pressure back pressure 25psi hain tab bhi -18 tak nahi jata tell me reason
2-8 Degrees par bhi almost 38 se 40 ke bich hi rahega na Back pressure. Kya R404A chiller ke liye use kar sakte hai kya...? Next time R407A par video banao. Aur ye bhi batana ki R407 ka use freezer me kar sakte hai kya aur nhi to kyo..?
Kcm 475 lal compressor me expansion valve laga hai orifice no 3 hai lekin back pressure 70 se 80 chalta Hai temperature jaldi kam nahi hota hai or back pressure kam karne par kam nahi karta hai
Wow very good knowledge because exactly pressure your explained pls more videos your experience
I would like to express my admiration for the exceptional work you do in the field of cool room design. Your God-gifted talent and expertise truly set you apart, and you have made a significant impact in this area.I believe your contributions have earned you recognition as a cool room expert, and I would love to learn more from your insights. If possible, could you kindly share a video showcasing your cool room designs? It would be greatly appreciated.
I made many videos on the cold room please check the playlists and thank you so much 🙏
Bai sab jb -20tprecher pa jae ga to us ka high perisher km hojae ga mere khial me ha
Perfect bro! U have nice knowledge
Bcuz i have 15 years experience in this field ❤
@@Onemanarmy-jx1cq thanks
very correct information ,and I am doing same job since 33 years
Thank you..
Itna deeply and Right information dene ke baad bhi log Negative Comments karte hain
Sir cold storage me lp 0 psi ke ache aur hp 290 psi araha hai aur gas 404 a hai cooling Barabar nahi araha hai .
Very good 💯💯
OR Sab se assaaan hai subcoolong 7 to 10 rakho itna nhi sochna hai
Bhai video bnanae ke Liye bahut padna padega
Bahut achchha samjhaye aap ne
Thank you
Bhai bht acha love you form pakistan
Thanks
भाई जो आपने बताया बहुत अच्छा बताया भाई एक बात पूछनी थी कंप्रेसर कितने टीआर का होगा यह सभी में यह टी आर कंप्रेसर् का बैक प्रेशर हो गया🧐
Bhai Tr. se koi fark nahi padta hai hai back pressure par , Unit ki volume capacity par depend karta hai
Bhai 6 temperature ko ki gass charge karne hai semi hermetic compressor
Mins 40 50 ki gass pressure kiya ho gi bata de
Thanks brother
very nice video
but aporate chiller R404a hai 25 psi thik h ya nhi +2 ya 4 temperature keliye
20 to 25 psi is good
Sir cold room ka panel par video banao basic se solenoid valve ka connection kaise karte h & timer
Coming soon
Cold storage ka full wiring banawo
Substitute for 404?
Bhai 1 no
سر،مرا قلفی مشین ہے اس کے لی یہ کون سا کیس سے ہے
Bhai. Maine 404 ka expansion valve change krke. 22 gas ka expansion valve lagaya. Aur gas Bhi 22 charge kiya lekin - 18 tempreture nhi aa raha .oil seprator. Oil. Driyer. Bhi change kiya compressor pumping bhi ok hai fir bhi. - 13 se neeche nhi aa raha hai. Bhi kya problem ho sakta hai
Cold Room R 22 gas ke upar Jo video bni hai wo dekh lo Puri agr fir bhi temperature nahi aaye toh baat Krna aa jayga
Hallo sir I am from Moradabad.
Sir r22 ke liye batao sir
Good Aap toh Hamare Padosi ho .
Ok jaldi hi
Super hit 👍👍👍
Seplast freezer plastic body chemical wali ice creem freezer hai uska -23 se liche nahi ja rahi kya karu r404 gass hai customers ka kahana hai pure raat me 10 point tak hi charge hoti hai bas din bhar me -9 tak a jati hai ice creem pighalane lag jati hai
Cold storage ka full wiring banawo
@@hasimjan3200 playlist check kro already upload hai
Bhai cold room temperature -13 ke niche jata nahi semi hermetic compressor hain pressure back pressure 25psi hain tab bhi -18 tak nahi jata tell me reason
@@RahulDhumal-w9u gas Kaunsi hai and high & back pressure Kitna hai
Bhai cold storage compressor k size or defrost heter k wattage ki video b bnaay
Okk
Sir cold room kitna ariama kitna t r lagana chhia piliz
Ak video banaya❤
Okay
Waise apne achha bataya hai apke koshish ko mai appreciate karta hu .apka sukriya.
Thanks
2-8 Degrees par bhi almost 38 se 40 ke bich hi rahega na Back pressure.
Kya R404A chiller ke liye use kar sakte hai kya...?
Next time R407A par video banao.
Aur ye bhi batana ki R407 ka use freezer me kar sakte hai kya aur nhi to kyo..?
Okk
Kcm 475 lal compressor me expansion valve laga hai orifice no 3 hai lekin back pressure 70 se 80 chalta Hai temperature jaldi kam nahi hota hai or back pressure kam karne par kam nahi karta hai
Freezer mai 1and 2 No.orifice use hota hai and back pressure jada hai
R22 me -18 to -24c me suction pressure kitna psi hoga ?
15 to 18 psi
Ok big bro
Pressure drop kiya to kitna psi hona chahiye
Running pressure 30 psi he to kya kre ? -18c temperature lana he
Great 👍👍
R22 ka minus temp me kitna psi hoga
30 psi back pressure
134 ka backpressure minus temp ka liya
R22 pe bhi banao
Okay
Tnx sir❤
Mera - 10 c par 60 back pressure rahata hai ice making plant hai
Sir ice creams machine ke bare me knowledge
Playlists check kijiye kafi videos hain ice cream machine ke upar
Cold storege unit p display temperature jaldi kyun kam hota h. Standing temperature nhi rehta 2 minutes v
Room sensor ki jagah change kar do
r410 a pr banaiye plz
Ok
R22 ka suction pressure zoada na yeh to 25 se 30 hota hai
Ye only 404a gas ka hai
R22 call room banaen
Soon
Aysa hi video R22. Ka video banao
Okay soon
R22
Okk
आपकी आवाज कहीं कहीं बहुत कम है ,भाई साहब
Mic problem ho gyi hogi
502
Okay
Bhai un logo ny 80 90 ac ka bp he pakag ac wagra
Ap smjh skte ho
Apka mobile no. Cahiye