Haier Ductless Mini Split Refrigerant Pump Down

แชร์
ฝัง
  • เผยแพร่เมื่อ 5 ก.พ. 2025

ความคิดเห็น • 107

  • @adobemastr
    @adobemastr 2 ปีที่แล้ว +6

    This was a good video! Both of the speakers were wearing wired Lavalier microphones so the audio was excellent, and they did not add any loud, annoying, or inappropriate background music to overpower and ruin the dialogue. Excellent job!

  • @nickstewart3
    @nickstewart3 4 ปีที่แล้ว +9

    Just what I was looking for. Clear and to the point, thanks fellas!

  • @misenko856
    @misenko856 2 ปีที่แล้ว +8

    Guys, nice video but what about to purge the yellow hose before evacuation ? At the end compressor creates a little bit of vacuum as you said and suck in everything what was in yellow how. Since you did not purge it, then it sucked this oxygen in a hose, which is pretty long by the way, into the system. Or am I missing something ?

  • @sudhirtirkey3234
    @sudhirtirkey3234 2 ปีที่แล้ว +18

    I do in a different way. The machine is kept running then hose is attached to the suction pipe. Running presssure is less than standing pressure so attaching the tube is easier and refrigerant leakage will be zero or less. Second, the discharge line should be closed slowly so that there is no sudden pressure shock to the compressor. This I think is a better way of doing.

    • @LC-qi5ff
      @LC-qi5ff 2 ปีที่แล้ว

      Totally agree with you

    • @misenko856
      @misenko856 2 ปีที่แล้ว +2

      Good point to attach the gauge hose when system is running. But I would also purge the hose after is connected, there might be lot of oxygen trapped and at the end it's all sucked into the system. I saw several videos like this from pros so I'm not sure what's going on. And I'm just amateur enthusiast...

    • @robertinogg
      @robertinogg ปีที่แล้ว +3

      What about the air in this yellow hose?

    • @extremeair1199
      @extremeair1199 ปีที่แล้ว

      Yes could have bled that while it was running before pump down, and also good idea to run compressor for a min before closing off discharge valve.

  • @rpsmith
    @rpsmith ปีที่แล้ว +4

    No eye protection and no gloves! That's how real men do their work! :o)

    • @b52tricopter
      @b52tricopter 2 หลายเดือนก่อน +1

      We don't need no stinking PPE.

  • @christopherkrueger4328
    @christopherkrueger4328 2 ปีที่แล้ว +2

    EXACTLY what I needed. Thank you.

  • @b5a5m5
    @b5a5m5 2 ปีที่แล้ว +8

    Your "de minimis" release can be reduced a bit by adjusting the valve core depressor in the hose fitting. And also by getting some core removal tools.

    • @LC-qi5ff
      @LC-qi5ff 2 ปีที่แล้ว +2

      And by attaching hose when system is running (less pressure in suction line)

    • @MarcelHVAC
      @MarcelHVAC 2 ปีที่แล้ว

      @@LC-qi5ff And use a hose with a schrader pusher

  • @TomTom-nk2rt
    @TomTom-nk2rt 2 ปีที่แล้ว

    Thank you very much for the really detailed and easy to understand explanation in your video, tiptop

  • @brobb5767
    @brobb5767 2 ปีที่แล้ว +1

    Well explained and straight to the point 👍

  • @michaelcostello6991
    @michaelcostello6991 2 ปีที่แล้ว +2

    Good video guys. Thank you I am replacing a faulty unit. I may not be able to get the compressor to run !!!! I guess it needs a full recovery procedure otherwise

    • @coolsriz
      @coolsriz 2 ปีที่แล้ว

      Hey Michael, can you summarize how you went about doing this. I have the same challenge with my Indoor unit malfunction. So have to do a full recovery procedure.

    • @misenko856
      @misenko856 2 ปีที่แล้ว

      If it's faulty why just not close discharge and suction valves on the unit and just disconnect it ?

  • @IAmAnAiAndroid
    @IAmAnAiAndroid 2 ปีที่แล้ว +6

    the gauge and service hose will have air/moisture in them when you connect, once you turn the unit on won't that pull it into the system? Wouldn't it be better to connect a gauge directly to the service port without the hose to reduce the amount introduced or is it just negligible?

    • @MarcelHVAC
      @MarcelHVAC 2 ปีที่แล้ว +2

      He should have pull vacuum on that line first,

    • @misenko856
      @misenko856 2 ปีที่แล้ว

      @@MarcelHVAC Or purge it with little bit of refrigerant in the system. How you want to pull a vacuum on that hose if it's already connected to AC ? Only wat is to have that special safety - leak free valve which connects to 5/16 port. So after connection the hose they just should open valve on a manifold for a second...

    • @misenko856
      @misenko856 2 ปีที่แล้ว

      Not immediately but for sure at the end of evacuation once compressor creates a litle bit of vacuum. All what was in the hose after connection is now sucked in the unit...

  • @savoy6
    @savoy6 2 ปีที่แล้ว

    Great video!. Thanks guys

  • @kadeemantoine2335
    @kadeemantoine2335 3 ปีที่แล้ว

    Best video I have watched

  • @BYENZER
    @BYENZER 4 ปีที่แล้ว +7

    At 4:38 mm:ss: No mention of FSCit: FSC - 'Front-Seat=Clockwise'
    At 08:00 mm:ss: NO, you did NOT pull all the refrigerant into the 'compressor'. It's in the receiver tank (if equipped) and the condenser coil, mainly.
    Otherwise, an EXCELLENT VIDEO.
    Keep up the good work!

    • @themrmoy40
      @themrmoy40 3 ปีที่แล้ว +1

      looks like the used before, locos🥴

    • @BYENZER
      @BYENZER 3 ปีที่แล้ว

      @@themrmoy40 Pardon?? No comprendo.

    • @dennisdoroshenko6582
      @dennisdoroshenko6582 2 ปีที่แล้ว

      @@BYENZER he's cracked out on a good one

    • @misenko856
      @misenko856 2 ปีที่แล้ว +1

      Those are just details :) A bigger problem is that they've sucked all the air in the the yellow hose into the system at the end of evacuation...

    • @BYENZER
      @BYENZER 2 ปีที่แล้ว

      @@misenko856 YES! That too. Good catch. Nowadays, im noticing many such TH-camrs are intentionally making mistakes, just to generate clicks and comments to up their TH-cam incomes by jacking up their "engagement" numbers.

  • @keyronruddock9770
    @keyronruddock9770 2 ปีที่แล้ว

    Very nice and simple 👌

  • @mrgoggles1963
    @mrgoggles1963 6 หลายเดือนก่อน

    How would you do a pump-down on a multi zone mini split?

  • @MelvinAlc
    @MelvinAlc 11 หลายเดือนก่อน

    Do set it for cooling when doing the retrieval of the refrigerant back ???

  • @ericrmccormick
    @ericrmccormick 3 ปีที่แล้ว +10

    He didn't bleed the line so he is sucking a little bit of air back into the system.

    • @robertberin4872
      @robertberin4872 3 ปีที่แล้ว

      When I preped my mini split I didn't realize my schrader valve wasn't being depressed and released the refridgerant into the system. I didn't start it. Should I do what he does or should I evacuate the system and recharge it.

    • @joesutera6940
      @joesutera6940 3 ปีที่แล้ว

      Noticed the same thing

  • @Kopano-Mocumi
    @Kopano-Mocumi 5 หลายเดือนก่อน

    Well understood thank you.

  • @gennarocaputi1700
    @gennarocaputi1700 3 หลายเดือนก่อน

    Hello ,,what about when the unit is not operating ??
    Can you push the charged lines back into compressor any other way ? With a vac pump ? Or is that sucking only and cannot push , gas back unto compressor ??

    • @anticapitalize
      @anticapitalize 22 วันที่ผ่านมา

      If the compressor in the unit isn't working you have to use a refrigerant recovery machine to pump it all out.

  • @aqualife3389
    @aqualife3389 3 ปีที่แล้ว +1

    After the refrigerent is pumped in Shoulbi shut down the unit by remote or shut down the outdoor unit from outside?

    • @Sneakybeave
      @Sneakybeave 2 ปีที่แล้ว

      I just shut the service port and pull the disconnect.
      Careful when disconnecting the line from the system as it will be filled with high pressure, likely liquid refrigerant, wear gloves.

    • @MarcelHVAC
      @MarcelHVAC 2 ปีที่แล้ว

      @@Sneakybeave and glasses

    • @misenko856
      @misenko856 2 ปีที่แล้ว

      @@Sneakybeave What ? There will be no pressure in the hose or lines after evacuation and after you close the valves... There will be more likely vacuum.

  • @jeepaz79
    @jeepaz79 3 ปีที่แล้ว

    great video

  • @sarkisbalanjian7999
    @sarkisbalanjian7999 10 หลายเดือนก่อน

    Is the blue gauge closed or opened?

  • @RoberthSilas-z4f
    @RoberthSilas-z4f 4 หลายเดือนก่อน

    Mantap

  • @richardgibbs00
    @richardgibbs00 2 ปีที่แล้ว

    Witch one do you open first to release refrigerants back

    • @marconantel7735
      @marconantel7735 ปีที่แล้ว

      Thoughts on this vary, my vote is the suction line

  • @AsBi1
    @AsBi1 2 ปีที่แล้ว +1

    Very helpful

  • @craigrobinson4161
    @craigrobinson4161 3 ปีที่แล้ว

    Great video guys. Went to check pressure in my unit. Got a static psi reading of 25lbs. when I hooked up gauge. When I turn the unit on, in cool mode, line pressure pressure quickly decreases to -10hg vacuum. Turn unit off. Pressure quickly rose back up to 25lbs. Is it a Leak or a clog or just super low on 410?? Im leaning towards a clog. And how that would troubleshooted. Thoughts? Thanks.

    • @harmonicwaves8375
      @harmonicwaves8375 2 ปีที่แล้ว

      Did you ever figure this out? I have exact same issue...

  • @rondail5675
    @rondail5675 3 ปีที่แล้ว

    Well done!

  • @reyrey9634
    @reyrey9634 3 ปีที่แล้ว

    So in mid winter..if you want to pump down the heat pump...same procedure for heat mode?

    • @misenko856
      @misenko856 2 ปีที่แล้ว

      Hair drier 😀

  • @Talentman18
    @Talentman18 ปีที่แล้ว

    Thank you

  • @benarrocheilyes1284
    @benarrocheilyes1284 ปีที่แล้ว

    How about the app! How it works?

  • @nampam3945
    @nampam3945 3 ปีที่แล้ว

    How long in minutes did it take to pull down the refrigerant?

    • @anyname367
      @anyname367 3 ปีที่แล้ว +1

      Takes about 40 sec

    • @nampam3945
      @nampam3945 3 ปีที่แล้ว

      @@anyname367 Wow thats fast, small volume I guess. thank you

  • @KeenPotato
    @KeenPotato ปีที่แล้ว

    Haha why leave the compressor running when you have both service valves closed? Pull disco then close suction service

  • @joeyysossa4144
    @joeyysossa4144 2 ปีที่แล้ว

    Did you pull a vacume to a -30 psig???

    • @Sneakybeave
      @Sneakybeave 2 ปีที่แล้ว

      Any amount of vacuum will do. One you have it in a vacuum the losses in the line set will be far below an oz, probably in the grams of refrigerant.

    • @misenko856
      @misenko856 2 ปีที่แล้ว

      @@Sneakybeave But one should not forget to purge the hose before evac, otherwise....

  • @ride-it-outtimandtoni232
    @ride-it-outtimandtoni232 3 ปีที่แล้ว +2

    Check your copper line sets that white ISO POLAR insulation is causing an acidic climate when wet that creates pin holes in the copper. I pulled out a run and put up a video of it leaking through little pin holes over a 15 ft span. Still have another 160 Ft to pull out and the suppliers and manufacturers are trying to hide the failure and pass costs on to you.

  • @rivera9185
    @rivera9185 2 ปีที่แล้ว

    We can do same on Four Zone Ductless Mini-Split ? Thank you

    • @EmersonSwaninc
      @EmersonSwaninc  2 ปีที่แล้ว

      Yes the method is the same on multi-split units as well.

    • @VirgilioNabor-cu7xk
      @VirgilioNabor-cu7xk ปีที่แล้ว

      @@EmersonSwaninc , Hi, meaning turn on all the indoor units at cool setting at the same time then closing all the valve once go to zero and shutdown the main switch?

  • @devinbenoit8370
    @devinbenoit8370 2 ปีที่แล้ว

    What size adapter is that

    • @EmersonSwaninc
      @EmersonSwaninc  2 ปีที่แล้ว

      Standard r410a hose adapter, female 5/16 SAE x male 1/4 SAE. Can be purchased individually or in kits such as yellow jacket.

    • @EmersonSwaninc
      @EmersonSwaninc  2 ปีที่แล้ว

      One more thing, the contractor should have two of them and they should always check for a good o ring before use.

  • @MrKdebolt
    @MrKdebolt 2 ปีที่แล้ว +3

    Amateur hour. Sucked air into the system because you didn’t purge your ridiculously long service hose. It’s also not a liquid line on a mini split. The metering device is in the outdoor unit.

    • @tombomombodombo
      @tombomombodombo 2 ปีที่แล้ว

      How do you purge the hose?

    • @misenko856
      @misenko856 2 ปีที่แล้ว

      @@tombomombodombo you connect it to service port and open the valve on manifold for a second or so.

  • @icidro1
    @icidro1 3 ปีที่แล้ว

    great vid..can you pump down your system without a schrader valve in it?

    • @kw1984
      @kw1984 3 ปีที่แล้ว

      Presume so. The valve is just to attach a guage to monitor the refrigerant being drawn back into the condenser.

    • @misenko856
      @misenko856 2 ปีที่แล้ว

      I can't get this. What do you mean without Schrader valve? Schrader valve where ? On 5/16 service port ? That valve is there to hold refrigerant in the system and you can't remove it if there is refrigerant in the system. But if you mean to pump down the unit without manifold gauge and hose then yes, this is also possible. But you may leave some refrigerant in lines and needs more experiences.

  • @danielivoicila1860
    @danielivoicila1860 4 หลายเดือนก่อน

    You need to be EPA type 2 not necessary to be EPA 608.

  • @mdsaifmdsaif3328
    @mdsaifmdsaif3328 3 ปีที่แล้ว +1

    Malti ac pamp Don gas recovery please sar

  • @Fastrose328
    @Fastrose328 3 ปีที่แล้ว

    8:19 seems pretty enlightend but when it's time to let the other guy share (older male) his mood went down. :) once a hater always a hater. 🙏

  • @hvacandvrvspecialvedoindus7891
    @hvacandvrvspecialvedoindus7891 2 ปีที่แล้ว

    Haier Vrf pump down setting 😊l 🙏

    • @EmersonSwaninc
      @EmersonSwaninc  2 ปีที่แล้ว

      We don't currently have this video but it is something we can look at making in the future. Thanks for your interest.

  • @HVACR-Airman
    @HVACR-Airman 3 ปีที่แล้ว

    Dimaximas release low loss fittings are required by EPA standards

  • @gorillaxrich
    @gorillaxrich 9 หลายเดือนก่อน +1

    That wasn't a tiny release of refrigerant... That was venting... Your the trainer??? WITH NO GLOVES...

    • @CarlosDelaoGunEngraver
      @CarlosDelaoGunEngraver 6 หลายเดือนก่อน +1

      looked painful

    • @gorillaxrich
      @gorillaxrich 6 หลายเดือนก่อน

      @@CarlosDelaoGunEngraver Exactly, he knew he'd better stop it frostbite or not or they gone frost-bite his bank account 😄...

  • @HVACR-Airman
    @HVACR-Airman 3 ปีที่แล้ว

    Why cant you just pull down to 0 PSIG ?

    • @misenko856
      @misenko856 2 ปีที่แล้ว

      You can, why not ? But those gauges are not that precises so if you want to be sure you've evacuated everything you may want to create a little bit of vacuum.

  • @johnbohmer4319
    @johnbohmer4319 3 ปีที่แล้ว +1

    What's up with the lineset? Somebody let corky play HVAC tech for a day?

  • @Sneakybeave
    @Sneakybeave 2 ปีที่แล้ว +2

    Wear gloves, please. That “completely normal” release of refrigerant he was talking about can give you serious frostbite. Don’t be like this guy.

    • @airplanenut6242
      @airplanenut6242 10 หลายเดือนก่อน

      That’s the truth! Even that tiny amount is super cold!

  • @briekhnaa
    @briekhnaa ปีที่แล้ว

    Tiny amount 🤔

  • @pokerbuddy2227
    @pokerbuddy2227 2 ปีที่แล้ว +1

    My flare is leaking, so I’m going to try this vs paying some dude 700$

    • @pokerbuddy2227
      @pokerbuddy2227 2 ปีที่แล้ว +1

      Worked perfectly

    • @gf2e
      @gf2e 2 ปีที่แล้ว

      Thanks for posting the update. I always wonder if people succeeded. This looks a lot easier than using a refrigerant recovery system. I’m planning on installing my own mini split and didn’t realize you could just suck the coolant back in!

    • @MarcelHVAC
      @MarcelHVAC 2 ปีที่แล้ว

      @@pokerbuddy2227 You should not have done that with a leak in the system

    • @misenko856
      @misenko856 2 ปีที่แล้ว

      Did you re-flare the pipe or what did you do ? Probably just tightening them up would help as well or ?

  • @Fastrose328
    @Fastrose328 3 ปีที่แล้ว

    Add a public comment...

  • @robertofranciscoriverabibi3264
    @robertofranciscoriverabibi3264 2 ปีที่แล้ว

    Fff

  • @user-bj4lp3fr1o
    @user-bj4lp3fr1o 3 ปีที่แล้ว +1

    No gloves and no eye protection.

    • @ictviamfortruthgoogleisspa5886
      @ictviamfortruthgoogleisspa5886 3 ปีที่แล้ว

      hey put yo shitty mask on too,, just in case, some bullshit gov created virus gonna get in yo trought

  • @akuuab
    @akuuab ปีที่แล้ว

    No gloves, no eye protection.