    Why display showing "out of range"

    • @SurveyMentorWaqas
      @SurveyMentorWaqas  14 วันที่ผ่านมา +1

      1.Exceeding Vertical Angle Limits: The vertical angle of the Sokkia CX 105 may have a specified range, such as -30° to +90°. If the instrument is tilted beyond this range (for example, pointing too high or too low), it will display "out of range."
      2. Incorrect Instrument Setup: If the total station isn't leveled properly or is set up on uneven terrain, it could report an incorrect angle, leading to the "out of range" message.
      3. Calibration Issues: The vertical angle sensors may be out of calibration. If the total station hasn't been calibrated recently or has undergone rough handling, this could affect its ability to accurately measure vertical angles.
      4. Obstructions or Reflections: If there are objects or reflective surfaces near the instrument, they may interfere with angle readings and cause the instrument to interpret vertical angles incorrectly.