1 ton ac= 3.5kw!!! ye cooling capacity he.isse current nai niklega.current nikalne ke liye jo power use karna he wo around 1.2kw hoga for 1 ton ac, 3 star 2020
Sahi pakade है
खाक electrican banega ampier नाही niklna ata hai aur video banata hai ise dekhakar chaman chutiye ac ka wire jala dal ते hai 🤣🤣😂😖😖😖😒🙏
Aap bahot achche se samjate h Thank you bhaiya gi 👌👌👌🙏🏻🙏🏻🙏🏻🙏🏻🏆🎖
Sir the way you clarify things is amazing, please tell if PCCB or DP switch is also required with MCB with 1.5ton split dual inverter AC, also tell voltage stabilizer lagana chahiye ya nahi?
Sir 40 Ampere k mcb b hun use kr sakte hai. 1.5 ton ac k liye.????
Nice video sir
Sir mere ghar me 1.5 ton ka AC hai aur 4 room hai geser hai sabhi room me fan hai led spot light hai to main distibutter Box me kitane Amp KA MCB Lagana hai?
Can we run 1 ton and 1.5 tone ac at a time.. because when I turned on both AC MCB is tripping
16A switch se chalane me koi dikkat toh nhi hogi please reply
Bro 3.5 kw is cooling capacity not power capacity. 1 tonne ki power capacity 600 watt se 1200 watt tak hoti hai.
Please let us how much socket for Ac for 1.5 ton Ac also please let us know for dishwasher and washing machine for 6 kg how much amp amp
1.5ton ka split ac ke liye 16amp ka mcb lagta he to ac thik se work karega??? Jaisa ke cooling sahi se hona.ya to fan ka beech beech me fast slow hona??
Kafi achxese kam karega bhai jitna kam ah ki mcb per chala pauge utnahi jyada safe rehata he👍
So helpful information thanks a lot
Sir 1.5 ton AC me 32 amp ki mcb kis type ki lagaye B type or C type ?
Thanku very much sir.... kerala...
If u guys have inverter AC 1.5 ton then 16AmP mcb kafi hai .... 20 AMP if want to have some buffer. But know 16 AMP will not trip at 16 amp it will take more current. Also dont use overrated mcb, they may not trip and u may get things damaged.
If I am buying 1.5 ton inverter AC, I will go with 16 AMP type C MCB.
Bhai Haier ka ac lagwaya hai 1.5 ton ka jo install karke gaye the vo bole electrician se 32 amp ki MCB lagwa lena to kya 32 amp jyada ho jayegi bhai aap bta do 1.5 ton ac k liye konsi MCB sahi rahegi
Sir mujhe bataiye k lg ka 1.5 ton ka ac ( 19 vnxf hot and cold )wale ac k liye kitne ampere ki MCB lagani chahiye..maine lg authorised ( Jeeves through Flipkart) k aane se phle hi local technician se already wiring karwa Li thee un logo ne 40 amp ki MCB laga di .
I m scared that . Ye kahi jyada na ho..
Agar 35-40 amp current flow hoga to ye MCB trip hi nahi hoga or 40 amp tak aate aate to kahi ac ki pcb / other equipment burn na ho jaye kahi.
Hamare yaha voltage ⚡ 155-240 rhta h..
Us case me baithaye k kitne ampere ki MCB suitable h.
Local market technician logo k paas jaata hu to ye hi bolte h hum to 20 amp ki bhi de denge but fir compressor load lega to wo baar baar trip hogi fir fayda kya h..
Superb job Bhai sahab....
Super Excellent Video
Sir earthing alag karni padegi kya?
Bai ac toh 6 ya 7 amp leta hai fir 25 amp mcb kyo lagaaya jata hai. .plz reply
1 ton ka ac 10 pc yaaki baad 30 amp mcb se chala sakte hey please give idea
1.5ton ka 4ac ke liye kitna mm ka service wire chayie aur kitna ampere ka main switch ka mcbchayir
हमारे पास 1.5 वोल्टास का इनवेटर ए सी 3स्टार हैं जिसमे c 16 का MCB लगा है जो सही चल रहा आप 32a का बता रहे हो
Bhai mere ghr m normal wiring h. To AC ka plug kha lagau. Matlab agar m normal board m he connection kr du to kya wiring jal jayegi? Kya direct meter k baad jodna pdega तार?
Bhai load or wiring ki ratings par depend karta hai ke ac chal payega ya nhi
Sorry to say but you seem to be completely unaware of current, power and cooling capacity of an AC. You are comparing cooling capacity of those ACs with the energy consumption. Nominal current drawn by a 1.5 ton 5 star AC is 6.2 Amps. So, C16 MCB is perfect for 1.5 ton AC even it it is a 3 star AC. If you use more rating MCB than required then it will not trip in case of overload which in turn will damage the AC. For 2 ton AC one should use C20 MCB. And for 1 ton AC you should use C10 MCB.
1.5 ton ac consume 1800 watt power and max. 8 amp running current and also requires max. 40 amp inrush current. so 16amp c type mcb is perfect for 1.5 ton ac.
@@sonukadian7998 first you know what are purpose of MCB, purpose of MCB are to maintain overload protection and short circuit protection. To save wire, switch and other electrical appliances proper rating of MCB is required. 40 amp mcb can run 1.5 ton ac and may give short circuit protection. But it will not give you over load protection . In case of over load , used wire ,switch , other electrical appliances and ac machine may damage. So perfect ratting of MCB. is required in every case of electrical circuit. Use of higher rating of mcb may not give you over load protection and may damage the circuit .For 1.5 ton ac machine 16 amp C type mcb is perfect choice.
Why 16 amp MCB why not 10 or below 16 amp for 1.5 ton AC as current is 8 amp?
@@dinanathpingalkar171 1.5 tone ac needs about 40 amp inrush corrent at the moment of its starting for a fraction of a second, 16amp c type mcb can withstand about 40 amp inrush corrent. 10amp or below than 10 amp rated mcb is not suitable to withstand 40 amp inrush corrent.
Best job .. Thanks
Bhai yesterday Direct Current ka formula hai..Alternating current ka nhi jis per AC Chalta hai 230v AC
Veeeeeeerrrrrreyyyyyyy niceeeeeeeeeeeeee sir
Bhai mera 1.5 ton ka ac 10 amp. Pr chl raha h polycab ki mcb h kaise chl ra h
Nice video and thank
Very useful information 👍
The running current in 1.5 ton AC is between 6 to 8 Amp. So you have to install 10 A type B MCB.
No bro....first mcb should be of type C , short circuit circuit is approx 4-6 times of rated.....if you use 10 -16 amp it will burn or trip someday in normal condition
Bhai mera 1.5 ton ka ac hai bt mene 15a ka switch lga liya hai Havel ka hai tho kya chnge krna padee ga ?
Very nice your explain sir 😊
Bro cooling capacity se ampere kyu nikal rahe ho.
Power consumption alag hota hai ac ka.
Calculation galat ho raha hai.
1.5 ka inverter ac 2100 w leta hai.
Aapne kabhi dekha hay 1 ton ka ac kitna amp lete hay. Pahale check kijiye uske bad video banayea.
Sir, kisi bhi ghar ka loa
D kaise calculate karein
1.5 ton ki ac hai, 25A ka socket hai aur plug 15A ka , ac 3 mint chalne ke bad mcb down ho ja raha hai , plz hlp me
Sir 3 ac par kitne mm tar dale
सर यदि 1 टन के विंडो ए सी मैं 32 एम्पिअर की एम सी बी लगाएंगे तो कोई दिक्कत तो नहीं होगी कृपया गाइड कीजिए 🙏
How much ampere MCB I should use for my home main MCB
Ham aankh band karke 32 ki pel dete hain.. 😂😂😂
1.8 Daikin AC में कितने MCB लगेगी
Very Nice Information
Sir mere Ghar main 1.5 ton ka AC hai 1 fridge hai aur 3 fan hain aur 8 energy saver bulbs hain aur 1000w ki iron hai jab ye aik sath on karta hun tuo breaker trip hojata hai mujy is load par konsa breaker lagana chahe please suggest me from Pakistan
veri Good bro 👍👍👍👍 💖💗
Ampere to thik..
But kon se typ ki MCB lgaye
B, C, D
Thanks 🙏
2ton Ac ka plug & socket 16amp ka hai, dono jal jate hain har saal. Kitne ka lagaun jo chal jayein??
Plug or socket ki jagah mcb lgao or mcb as per load requirement lgana
Agar ek hi line par ac hai to 25 amp ka MCB lagana agar alag alag lione hai to 20 amp ka laga na MCB
Nice video
Thank you very much
Sir, jaise mere ghar mei 4 room hai aur sabhi room ka load 2000watt hai toh distribution box ya meter ke baad jo MCB lagta hai, woh kitne amphere ka hoga?
sir aapne bola ki 1 ton k liye 20A lagega lekin hamne to 1.5ton ka ac par 16A ka mcb lagaya hai bina short k trip nahi karta
C32 240V 4500A written on MCB
Is it fit for 1.5 Tonn AC.
Yes yeh 32 ampere ka mcb hai to 1.5 tin ac k liye more then enough hai
1.5 ton inverter ac me 20 amp ka hawells mcb lagaya he to kya chalega sir?
Nice information
❤❤❤
Kw 1 ਦੇ 4 ਜਾ 5 ਹੁਦੇ ਨੇ ac ਚ
Sir 1 tan me to 1000 waat hote h naa
Thank you sir
यदि एक टन के ए०सी०के लिए 25 एम्पियर का एम०सी०बी० लगाया जाए तो कैसा रहेगा?
Sir AC power P= VIcospi but you explained VI pleae explain why we not considered cos pi
Nice g
1 hours power moter me kitne ka MCB lgaye ki kisi ko lit na mare
2 ton AC k stabilizer?
Sir p.f.ko kiyo add nhi kar rahe ho
Totally Wrong information
Humans 1.5 ton Ka voltage ac 7 amp maximum leta hai mcb 10 amp se jada nhi lage gi
Invertor ac me b itna hi watt hota hai kya?
Lagbhag same rehata hai bes itna fark heki invoter ac her baktw full power nahi leta hai?
Main to 16 amp ka hi MCB use karta hoon ac acha chalta hai ghr ki alg lione hai aur ac ki alag hai
Which type and rating MCB is suitable for 1.5-ton convertible inverter ac ?,type C or B,,?16 or 24 or 32 amp Mcb?,,somewhere,someone suggested B type Mcb ,,becoz inverter AC has soft starting.!!
Agar 1 ton ke ac ko 32 ampare ka mcb laga de koi problem to nahi hoga
@@electricalstuff4u mai purchase karke le iya hu, kal ac ka installation hai agar 32 ampare ka 1 ton ko laga du koi problem to nahi hoga
Wrong information
25 amp ka mcb h aur 12 amp k stabilizer pr 1.5 ton ka ac chal rha h
Practical karke dekhao 1ton AC 3.5kw tum kahase lateho itna kw 1ton AC max 1.3kw hota he starting me 2kw tak load leta he
Aaj to inv b aaa gye h joo 500w tk hi load lete h
Ac ka switch or baton gram Q hota hai
wormg information 1 ac maximum load is 1500 watt ,
इस हिसाब से तो मेरे घर मे 1.5 टन के तीन AC है। और हर AC मे 32 Amp का MCB लगाये तो मेरे घर का कुल लोड तो 96 Amp खाली AC से ही आयेगा। तो क्या घर पर 100Amp का मेन MCB लगेगा। 😂😂😂😂
Ismein Power Factor kahan hai
0.8 ton k liya Kitna.. 16?
Hanji 0.8 ton ka ac 13A tak load lega to uske liye 16A ka MCB bilkul theak hai
👍
3_4 ampper chalta h
लेकिन इसमें एक झोल यह है कि लगा तो दे हम 1 टन एसी में 20 एंपियर लेकिन बाजार में जो दिखता है 25 एंपियर । रियलिटी में वह 25 एंपियर भी नहीं होता क्योंकि उसकी क्वालिटी डाउन होती है तो फिर किस क्वालिटी कर ले जो लिखा हो वही एक्चुअल में होल क्योंकि मेरे यहां 25 एंपियर का भी बोर्ड जल चुका है
Thank you sir 🙏🙏🙏
1 ton Kaur ac 1150 watt let hai maximum
AC ton AC chalane ke liye kitne mm ka wire lagta hai
@@kachravlogsss6802 panle boards se jada long hoga to ac ka supplying ta 4mm wire lagega. nehi to 2.5 wire heat hoga.
Mcb ke upar C 32 hai to C KA KAI
Bhai itna galat video mat banaye
Wrong calculation. You are taken cooling capacity not power. 😂😂😂
1 ton AC is aprox 6 to 7 Amp and 1.5 ton os aprox 7 to 9 Amp. For more details see on ratings charts mentioned on every AC.
Jab Meri Aisi 3.5 kilowatt hai to 1000 kilowatt kahan se a jaega
Ab 5 star ka ac a rha hi itni power nahi leta bhai kripya galat jankari na de
Wrong calculations. Plz correct it
1 Ton AC = 1.2 KW. to 1.5 kw.. Not 3.5 K Watt...
My Website electricalstuffs4u.com/
Get the Best Price
Air Conditioner :amzn.to/3LhjRsF