motor ir value || motor ir test || how much ir value for induction motor||motor ir value test
ฝัง
- เผยแพร่เมื่อ 5 ก.พ. 2025
- motor ir value || motor ir test || how much ir value for induction motor||motor ir value test
dosto is video me aap sabhi log motor ki ir value actual me kitani honi chahiye ye lern karne wale hai....so watch this video carefully and learn about motor ir value...
Bahut badiya sir 🙏🏻
good nice sir❤❤❤
Nice explain sir ji
Thanks and welcome
Sir LT and HT motor me
Magger DC voltage kitana set katege
According to motor name plate voltage..
Good st
Nice sir
Thanks and welcome
Sir IEEE ka konse standard se ye criteria pta laga hy?
IEEE 43 STANDARD 1974,2000
IEEE 43 STANDARD 1974,2000
@@excellentelectricalknowled6672 bohat shukria bhai, me jahan kam krta hun wahan ye standard use hota hy
Motors less than 1kV : IR > 0.5Mohm at 500volt applied voltage,
Motors greater than 1kv : IR > 1MOHM/1KV
Winding resistance unbalanced hai to kya kiajaega..?
Motor chalana par unbalanced resistance ke Karan unbalanced current ke Karan motor trip ho jayegi
@@excellentelectricalknowled6672 trip to ho jaega, per unbalanced resistance ko balance kaise kare..ya motor ko rewinding k liye bhejna padega..?
@@mopasand3980 yes motor ki rewinding krana paregi
Motor pm .cm kya kya Aktivije hai video kon si hai messege kardo brother agar video nahi hai to video message Karo brother
Bhai lt me megha ohm aati h..HT me Giga ohm aata HH..8 saal ka bekar h experience HH
Bai ir valu barabar as per kv+1 per arahato trip nahi hoga trip ja reason alage
Which voltage megger to be used
DC voltage
Ek baat smjh na aai pahle ka to formula bta diye latest formula nhi btaya aapne
Can you please tell me the latest formula ???
Practical ker k dikhaiye
Waisting time with wrong information