De ce sunt obligatorii măsurătorile continuității nulului de protecție și a conductoarelor active⁉️

แชร์
ฝัง
  • เผยแพร่เมื่อ 7 ม.ค. 2025

ความคิดเห็น • 24

  • @vladdutzi6937
    @vladdutzi6937 12 วันที่ผ่านมา +1

    Salut, multumim de explicatii. Ne areti si aparatul si cum se masoare corect? Multumim

  • @ELECTRICLIFE4U
    @ELECTRICLIFE4U 19 วันที่ผ่านมา +6

    EXACT! Și sunt obligatorii....măsurătorile!

  • @danst1132
    @danst1132 18 วันที่ผ่านมา +2

    👍👍Foarte corect si la obiect!! Felicitari si numai bine!

  • @pirvanadrian8742
    @pirvanadrian8742 19 วันที่ผ่านมา +2

    Felicitări pentru video! La obiect și bine argumentat.

  • @dumitrustelian1855
    @dumitrustelian1855 19 วันที่ผ่านมา +2

    Mulțumesc Mult, spor și sănătate multă

  • @FlorinUrzica
    @FlorinUrzica 13 วันที่ผ่านมา +1

    👍👍👍

  • @andreipaduraru3656
    @andreipaduraru3656 19 วันที่ผ่านมา +2

    Bravo! Foarte bine explicat!

  • @corneldecean943
    @corneldecean943 15 วันที่ผ่านมา +1

    👍

  • @dragobandas5301
    @dragobandas5301 18 วันที่ผ่านมา +1

    Salut Adrian & team
    Felicitari ptr efortul vostru cu aceste video-uri educationale.
    O simpla observatie.
    Nu poti avea nici un fel de pretentie de la cei ce nu cunosc importanta continuitatii conductorului de Protectie (Protective Earth).
    Daca exista “Electricieni profesionisti” care disputa si au indoieli in privinta importantei continuitatii acestui conductorului de Protectie, atunci nu am cuvinte .......
    Toti Electricienii cu adevarat Profesionisti cunosc faptul ca cel mai important conductor intr-o instalatie Electrica, este PE si de asemenea rezultatele obtinute in urma testelor obligatorii si periodice, sa fie in concordanta cu Normativul in vigoare.
    Care ar fi atunci rolul RCBO-urilor, si cum ar putea acestea sa functioneze correct, cind aceste aparate de Protectie sint menite sa previna socurile electrice si Electrocutarea ?!
    O zi buna va doresc.

  • @pmarius66
    @pmarius66 19 วันที่ผ่านมา +4

    Corect și adevărat ce ai transmis ,dar multa lume nu pricepe sincer am văzut meșteri autorizati ANRE și vai de mama noastră ce lucrări au executat mai ceva că un electro zugrav 😂😂😂

  • @adrianmihaita7459
    @adrianmihaita7459 19 วันที่ผ่านมา +3

    👍👏 SR HD 60364-6/2017 !!!

  • @ciobanumihaieminovici
    @ciobanumihaieminovici 19 วันที่ผ่านมา +2

    La prima mana se descopera cu duspolul si apoi se fac masuratori mai elaborate daca se constata lipsa continuitatii intre N si PE si tensiunea-230- intre PE si faza si N si faza.

  • @palimarueugenalin7499
    @palimarueugenalin7499 19 วันที่ผ่านมา +4

    Sa vezi cum e la Iași , acest video ar trebui trimis la administratorii de asociatii , mai bine de jumatate de oras nu are nici urma de impamantare.

  • @sorinsorin3618
    @sorinsorin3618 19 วันที่ผ่านมา +2

    Buna seara,o intrebare rog:pt o casa din lemn recomandat ar fi cabluri NYM-J sau NYY-J,multumesc si spor...!

  • @ioanmuntean7798
    @ioanmuntean7798 19 วันที่ผ่านมา +2

    🤚👍👍👍👍👍👍♥️♥️♥️♥️

  • @danieldejan9647
    @danieldejan9647 19 วันที่ผ่านมา +2

    Da este normal dar cine poate sa controleze pe cei care spun ca sunt electrician dar la bază nu este.

  • @monicapristanda856
    @monicapristanda856 15 วันที่ผ่านมา

    Bună ziua ,un domn electrician mi a schimbat contoarul cu unul nou și a pus un cablu direct din contoar ptr cuptorul electric de la aragaz ,dar când bag in priza sare siguranța ,cu toate măsurătorile făcute nu stie nici el ce nu este în regulă .As aprecia un o părere până găsesc alt electrician.Multumesc!

    • @RaduClapa
      @RaduClapa 15 วันที่ผ่านมา

      Din păcate sunt foarte mulți așa ziși meșteri care nu știu ce fac, și ca urmare beneficiarul are de suferit.
      Cu tot respectul, dacă nici acel domn electrician nu știe ce are de sare siguranța, mie îmi pare că nu e electrician.
      Nu veți găsi răspunsul problemei pe internet deoarece depinde foarte mult de ce e acolo. Poate fi o suprasarcină (având în vedere că e un cuptor) sau poate fi un defect al aparatului sau poate fi legată greșit priza.
      "siguranța" care sare este un MCB sau un DDR?
      Dumneavoastră ca beneficiar nu aveți de unde să știți toate acestea dar un electrician adevărat ar fi trebuit să le știe și să vă informeze.
      Ce măsurători s-au făcut? Cu ce s-a măsurat? Ce s-a măsurat? Alte întrebări care ajută la identificarea problemei.
      Soluția ar fi să chemați un electrician care chiar știe meserie și nu vă lasă de sărbători fără curent în casă.
      Ca mențiune, cred că ați vrut să spuneți că din tabloul cel nou v-a legat un circuit dedicat pentru cuptor, nu din contor.

  • @electro2709
    @electro2709 19 วันที่ผ่านมา +2

    👋🏻👋🏻🙏🏻

  • @mirceavsau9214
    @mirceavsau9214 18 วันที่ผ่านมา +1

    Puneți protecții diferentiale peste tot, pe toate circuitele, si n-o să mai ia foc clădirile, și e protejată si viata omului.
    Puteți să propuneți cand se mai fac modificări la I7.

  • @n55m6a7
    @n55m6a7 19 วันที่ผ่านมา +2

    Da in afara de I7 mai e si NTSM-ul pe care nu-l mai citeste nimeni... 👍👍⚡⚡

  • @palimarueugenalin7499
    @palimarueugenalin7499 19 วันที่ผ่านมา +2

    Vine mos Crăciun

  • @palimarueugenalin7499
    @palimarueugenalin7499 19 วันที่ผ่านมา +2

    Ia sa vedem ce mai e nou , sper ca nu te-ai suparat pe mine ieri ai sa vezi de ce.😂