Air cushion pressure at the 24 liter expansion vessel

แชร์
ฝัง
  • เผยแพร่เมื่อ 28 ธ.ค. 2017
  • The pump from the hydropower starts after about 5 liters of water, so I tried to put pressure into the expansion vessel up to 2 bar. Even so, more than 5 liters I could not get out again and the start time of the pump did not decrease.
    Thanks for watching the video.
    If you like my videos do not forget to SUBSCRIBE to my channel to DISTRIBUTE to others and give a LIKE if you appreciate what I do.
    You can also visit my site where you will find different fields PHOTOVOLTAIC, GRADINARIT, HOUSEHOLD, MANCARE, MISCELLANEOUS
    www.Energy-Sun.Org
    Have a nice day.

ความคิดเห็น • 200

  • @user-fe5lt4rh8r
    @user-fe5lt4rh8r 5 หลายเดือนก่อน

    Domnule te prețuiesc pt acest răspuns tehnic și clar Cătălin dorește să învețe și este de pretuit

  • @adrianad5936
    @adrianad5936 4 ปีที่แล้ว +3

    Multumesc Catalin, mi-am schimbat singura membrana !

  • @MariusChirnoaga
    @MariusChirnoaga 5 ปีที่แล้ว +8

    Asta cu beșica , cea mai tare!

  • @mariusvfp
    @mariusvfp 6 ปีที่แล้ว +46

    salut, "basica" nu se umple cu 24l de apa , specificatiile cer 1,5 bari aer la gol in el intra circa12l maxim ,presostatul e setat sa decupleze la3 bari dublul aerului , fa imparteala 24/2 =12litri si 1,5*2=3bari tu daca comprimi aerul din vas cu un alt fluid la dublu jumatate din vas e ocupat de acel fluid deci besica iti ocupa jumatate din volum12l presostatul vine setat din fabrica cu histerezis de1/2 el declanseaza la jumatate din presiunea vasului3/2=1,5bari,(de aici rezulta cei6 l de apa din tigaie, foloseste un pet de6 l e mai bine de masurat) cand aerul din vas scade, pe la flansa deobicei , presostatul nu stie ca vasul numai are aer si tot la 3bari decupleaza ,la destindere spatiul ocupat de basica e mult mai mare si cantitatea de apa eliberata intre porniri e mai putina din cauza modificarii raportului de1/2 apa aer la3bari, mama ei de matematica ,cataline tu esti baiat destept , sper ca restul care dau cu presupusul sa fi bagat ceva la cap, spor

    • @CatalinCiprian
      @CatalinCiprian  6 ปีที่แล้ว +1

      mariusvfp mihai da logica explicatia. Am bagat si 2bari si degeaba maxim 7.5 lutrii scot si porneste pompa. Deci ori il las asa ori schimb vasul cu unu de 100litrii

    • @mariusvfp
      @mariusvfp 6 ปีที่แล้ว +10

      Catalin Ciprian , salut , nu schimbi nici un vas nimic , mai pui unul in paralel , 2 sau 3 vase de 24 sunt mai ieftine decat un6l mai mare , plus dasta de se strica unul il anulezi , pui cate un rubinet pe fiecare intrare in vas si gata, e mai multa fitingaraie da asta e il poti plasa mai accesibil decat sa stai cu ditamai bomba in casa , incearca sa montezi vasele cu flansa in sus , membrana sa stea in pozitie verticala astfel nu se roade de peretii vasului si nu se sparge , multe nici nu mai au talc in ele , inainte de utilizare dale aerul afara , desfa flansa spala basica cu clor igienizeaza bine , apoi pe marginea basicii intre flansa si vas pe ambele fete pune pe guler vaselina auto , acolo la flansa scapa aerul pe care il bagi pe la fundul vasului, spor

    • @CatalinCiprian
      @CatalinCiprian  6 ปีที่แล้ว

      Nu e rea ideea cu mai multe vase in paralel insa intrebarea e creste volumul de apa consumat pana sa porneasca pompa daca sunt mai multe vase ?
      Buna ideea cu vaselina .
      Multam

    • @mariusvfp
      @mariusvfp 6 ปีที่แล้ว +3

      Catalin Ciprian , salut, pai cum sa nu creasca tu imparti volumul vasului la 4 si aia e cantitatea de apa intre porniri la 1,5 bari aer in vas gol. Men ideea asta cu vase membrane e nebuneasca credema , noua ne trebuie un vas din inox perfect igienic care sa resiste la cel putin 5 bari,pus cu gura in jos si bagat apa in el ,apa intra in el preseaza aerul apa urca pana la un nivel pana cand in vas se fac 3 bari presostatul se opresti si pa nene fara prostii si prostiute , cauta un butoi de bere agatal mai sus pe un perete tragei tevi si uita de saraciile de vase cu membrane , sunt cateva dezavantaje ca peste tot , uneori intra si aer pe instalatie dar daca iti concepi bine instalatia ,adica vasul ceva mai sus spre tavan conducta de alimentare ceva mai verticala pana jos apoi un rubinet de golire vertical sa mai scoti apa din vas cand se umple la presiune 0, hai la treba a la noapte te gandesti la butoiul de bere.

    • @CatalinCiprian
      @CatalinCiprian  6 ปีที่แล้ว +2

      hahaha esti tare :) daca as avea un butoi de bere prima oara ar trebuii golit :))) altfel nu merge treaba :)))

  • @costicaneagu3679
    @costicaneagu3679 3 ปีที่แล้ว +4

    24 de litri este tot conținutul bazinului dar diferența este clar că este cea din exteriorul membranei care este dezlocuită de AER iar interiorul membranei este umplut cu apă
    Sistemul total , este egal cu 24 l aer - apă
    Presiunea nominală în vasul de recomandare apă - aer este de :
    Aer = 1,6 bari
    Apă =1,8 - 2,2 bari ( presiune apă , pe presostat)
    Amortizarea apei pentru blocarea presostatului , pentru oprirea curentului electric este indusă de cei 1,6 bari specificații în cartea tehnică a vasului de expansiune iar forță modificăm pompei de presiunea apei se închide cînd ajunge la maximum 2,2 bari , maxim 2,4 bari care cel din urmă la 2,4 bari , va induce de la sine deteriorarea membranei într-un timp record mult mai scurt decît la o preșiune a apei de 2,2 bari maxim...

  • @user-fe5lt4rh8r
    @user-fe5lt4rh8r 5 หลายเดือนก่อน

    Bravo Costică Neagu am rezolvat problema pompei care funcționa continua prin desfacerea piuliței la arcul mare și la arcul.mic nu am înlocuit presostatul deși îl cumparasem

  • @costicaneagu3679
    @costicaneagu3679 3 ปีที่แล้ว +2

    Reglarea presostatului este destul de bună doar pentru maxim 2,4 bari ca la această presiune poate ridica apă pînă la 6 etaje
    De 6 etaje ×3m= 18 ridicați fără probleme

  • @costicaneagu3679
    @costicaneagu3679 3 ปีที่แล้ว +4

    Cătălina presiunea în butoi se face în felul următor
    Se scoate pompa de apă , din priză apoi se pune o pompă de aer , cu manometru de presiune aer , apoi se bagă aer exact 1,6 bari presiune cu un robinet deschis pentru ca apa să iasă din vasul de expansiune din membrană
    Deci presiunea de aer din vasul de expansiune este de 1,6 bari
    Presostatul se reglează la 1, 8 bari sau 2,2 bari presiunea apei
    Dacă vei dori o presiune mai mare o poți mari pînă la 4 bari din presostat , se strîngînge arcul cel mare

    • @CatalinCiprian
      @CatalinCiprian  3 ปีที่แล้ว +1

      Salut, multumesc de sfat

    • @costicaneagu3679
      @costicaneagu3679 3 ปีที่แล้ว

      @@CatalinCiprian
      Ca sugestie , ar fi foarte bine să nu mărești presiunea în vasul de expansiune ( în butoi de bere dacă este doar un butoi nu 2 butoaie) , mai mult de 2,4 - 2,6 bari , deoarece îți poate distruge supapa de sens fie să fie ea și în apă deasupra pompei sumersibilă dacă este cazul , deoarece va veni un nou defect , ca supapa să se supra-presurizeze mai mult decît ar închide și după atingerea maximă a presiunii să zicem maxim 4 bari (atmosfere ) supapă se va încolo și va pierde apă încetul cu încetul, și apoi va reporni pompa repetat , iar după un scurt timp se va auto-distruge supapa de sens ( în special dacă este construită din teflon cu material cauciucat în loc de material de bronz cu cauciuc (garnitura de închidere a apei în supapă)...
      Cu doar 2,2 bari presiune vei putea ridica la o locuință de 6 etaje , lejer , înr presiune destul de mare la un debit de 3/4 "(țoli)
      Succes...

    • @user-dy8yo3ck5m
      @user-dy8yo3ck5m 2 ปีที่แล้ว

      Cum îmi pot da seama ce presiune e la presostat ca nu arata niciunde??
      Presiunea nu îmi urca mai mult de 1,8 și de multe ori hidroforul nu se mai oprește...merge continuu...am schimbat presostatul și e la fel...prinde și aer ...sorbul l-am schimbat și tot asa merge

  • @razvanon
    @razvanon 6 ปีที่แล้ว +1

    ai facut bine . nu poti sa scoti din vas ( la presiunea reglata din presostat) un volum de apa egal cu volumul recipientului. probabil ca ai putea sa scoti mai multa apa din vas inainte sa porneasca pompa doar daca ai putea seta o plaja foarte mare de oprit/pornit pe presostat dar nu cred ca ti-ar place sa curga o data cu 5 bar si la final cu 0,5 bar.
    iti trebuie un vas mai mare (80-100 l) daca vrei sa porneasca pompa mai rar. chiar si asa ,dupa un timp, se pierde perna de aer si iar trebuie bagat aer

    • @CatalinCiprian
      @CatalinCiprian  6 ปีที่แล้ว

      Am inteles, probabil voi schimba vasul cu unu de 50 sau 100 litrii atunci.

  • @euse6240
    @euse6240 3 ปีที่แล้ว

    Daca este la 2 bari atunci când stă oprit cu apa in el și 0.5 când merge este corect?

  • @radufanuc
    @radufanuc ปีที่แล้ว

    Nu sunt instalator , dar supapa de sens trebuie sa fie închisă cat se evacuează apa din rezervor ,adică inițial ai o presiune in vas de cca 3 atm , ea pe masura ce apa este evacuat scade , cand ajunge la 1 atm ,presostatul pornește pompa si presiunea creată deschide supapa de sens ,presiunea in vas creste pana la cca 3 atm , cand se oprește pompa , procesul se reia . Daca ai debitul mare ,nu mai ajungi la 3 atm si pompa merge încontinuu , deci ,vei evacua mai multă apa din rezervor cu cat presiunea de pornire a presostatului este mai mică ,presupun ca la 1atm extensia balonului in vezica este maxima ,acum poate sunt avizați in materie si inteleg mai bine ,

  • @costicaneagu3679
    @costicaneagu3679 3 ปีที่แล้ว

    Fabricanții a dat dimensiunile etalon în funcție de capacitatea vasului metalic și dimensiunile etalon al interiorului călători al membranei , astfel încît cele două forțe să acționeze egale ca la un cîntar astfel încît să fie un randament cit mai mare si mai bun în corelare cu timpul de exploatare și uzura materialelor în construcțiea acestora

  • @gavrilassconstantin2952
    @gavrilassconstantin2952 3 ปีที่แล้ว

    Aveti idee de ce de vreo 3 luni imi baga bule de aer la chiuveta ,oare nu mai ajunge pompa bine la apa ?
    Nu prea sevede bime ca e de 15 m putul

  • @costicaneagu3679
    @costicaneagu3679 3 ปีที่แล้ว +2

    Nu poate intra exact 24 de litri de apă ca are bazinul 24 litri și în bazin intra aer nu apă
    Membrana are cam maxim 8 sau 9 litri de apă ca volum
    Atîta apă va trebuie să iasă nu 24 litri de apă

  • @balosumarian1839
    @balosumarian1839 4 ปีที่แล้ว

    Ai nevoie de un vas de expansiune mai mic, sau de un burduf mai mic. De 10 litri. Și trebuie să reglezi presiunea între 1,5 și 3-3,2 bari. Altminteri, debitul și presiunea la care funcționează rămân mult sub valorile nominale ale pompei.

  • @danielnitescu2582
    @danielnitescu2582 6 ปีที่แล้ว +1

    Salut
    Am si eu o intrebare
    Am instalat hidroforul de curand iar cand porneste are asa un sunet de "scârțâit"...Asa se aude el sau care poate fii cauza?

    • @CatalinCiprian
      @CatalinCiprian  6 ปีที่แล้ว +1

      Salut,
      daca se aude la vasul de expansiune este ok , si la mine a facut un timp dupa care nu a mai facut.

  • @parintele-
    @parintele- 5 ปีที่แล้ว +4

    Daca tu bagi aer in vas cam cum iti imaginezi ca poti "folosi" toti cei 24 l?
    Ii folosesti dar nu ca da scoti 24l intre porniri, o parte va fi ocupata de aerul sub presiune iar o parte apa.
    Acea presiune a aerului impinge apa in afara deci.. Spatiul ocupat de aer e folositor, doar ca nu asa cum iti imaginezi tu.
    Cat volum util are un vas de 24 l?
    Asta depinde de diferenta dintre presiunile de lucru.
    Atentie, presiunea initiala a aerului din vas se coreleaza cu presiunile de lucru ale presostatului.
    Adica, presiunes din vas trebuie sa fie foarte putin mai mica decat Pmin setata la presostat.
    De ex. Daca Pmin e 1.5 atunci in vas va trebui sa ai 1.4 bar.
    In felul acesta pompa va porni inainte ca toata apa din vas sa fie evacuata.

    • @CatalinCiprian
      @CatalinCiprian  5 ปีที่แล้ว

      Util raspunsul daca era pe un tot mai normal era si mai bine :)
      Multumesc, asa invatat in viata multe.
      O zi buna

  • @costicaneagu3679
    @costicaneagu3679 3 ปีที่แล้ว

    Pe scurt , indiferent de volumul vasului de expansiune folosit pentru hidrofor , presiunea de aer va fi doar cu o presiune nominală de ,, 1,6 bari " aer
    Așa cum vin și din fabrică cu aer în ele ca piesă de schimb echipate cu membrană în vasul de expansiune

  • @gheorghebueac3585
    @gheorghebueac3585 4 ปีที่แล้ว

    Salut cătălin
    Ce se întîmplă cu hidroforul care sa mîncat sita de la supapă fin fîntînă
    A intrat mizerie ,cum se poate curata ??
    Si inca ceva de ce nu se ridica presiunea la 2 bari .
    Merge in continuuu

    • @CatalinCiprian
      @CatalinCiprian  4 ปีที่แล้ว +1

      Salut,
      daca vorbesti de flansha de la vasul de expansiune aia se poate inlocuii gasesti la Dedeban sau la alte magazine de profil mai mici.
      Daca nu se formeaza presiune s-ar putea sa fie gata pompa.

  • @bogdanivan2109
    @bogdanivan2109 ปีที่แล้ว

    Vezi la producator care este presiunea maxima a vasului de expansiune...verifica si tevile la ce presiune rezista...verifica hidroforul ce presiune maxima suporta si apoi baga presiune mai mare ca sa vezi rezultatul... :)

  • @gavrilassconstantin2952
    @gavrilassconstantin2952 3 ปีที่แล้ว

    Am facut si mia mers foarte bine ,pacat ca la apa de put este mult calcar
    O intrebare ,as putea sa mai adaug inca un vas de expansiune de 50 pe langa ala care il am ?

    • @CatalinCiprian
      @CatalinCiprian  3 ปีที่แล้ว

      Da se mai poate adauga inca un vas. Asa am facut eu. Urmariti aici clipul cand am adaugat inca un vas th-cam.com/video/KUHA6LaQfqk/w-d-xo.html

  • @amprentareverticala933
    @amprentareverticala933 5 ปีที่แล้ว +8

    Dacă se bagă mai multă presiune de aer automat va intra mai puțini litri de apa in bășică

  • @cristachevizireanu124
    @cristachevizireanu124 4 ปีที่แล้ว +1

    Mai baiatule, dispozitivul caruia ii spui "besica", este o membrana elastica ce are rolul de a crea o perna de aer in vasul de expansiune. Apa ca orice lichid nu este compresibila si atunci se creaza intentionat o perna de aer, care este compresibil. Presiunea aerului creste pana la valoarea maxima la care este reglat presostatul, iar cand se deschide iesirea aerul se destinde si in acest fel se lungeste timpul pana se atinge presiunea minima, la care porneste pompa. Daca lipseste perna de aer, cum apa nu este compresibila se ajunge foarte repede la presiunea minima desi vasul este plin. La vase mari perna se face fara membrana, cu conditia ca vasul sa fie vertical iar orificiul de aer sa fie in partea superioara.
    Presiunea pernei de aer nu are nici o lagatura cu volumul vasului. (volumul vasului de expansiune se alege in functie de marimea consumului). Aceasta este in general mai mica cu 10% decat presiunea de pornire a pompei cu conditia sa fie masurata cand instalatia de utilizare este golita si presiunea de iesire este zero.
    Nu mai aburi lumea cu masuratorile tale cu cratita.

    • @pascarlat274
      @pascarlat274 4 ปีที่แล้ว

      Scuze că intervin. Presiunea de aer se face (are loc ), între peretele metalic al vasului de expansiune și burduf ( beșica cauciucată ) ...... și nu în burduf , domnule Cristache.

    • @gheorghealexandru4300
      @gheorghealexandru4300 4 ปีที่แล้ว +4

      Raspuns pentru dl Catalin Ciprian: La orice dispozitiv, trebuie sa stim constructia si functionarea.
      Constructie: La un hidrofor, presostatul regleaza presiunea in instalatie. Presostatul are o parte electrica si o parte mecanica. Partea electrica are un conector electric cu doua intrari de la priza si doua iesiri la pompa de apa. Legaturile firelor se fac in serie, linie cu linie, nul cu nul, si masa comuna. Partea electrica mai are un intrerupator rabatabil de curent, ca un ac de siguranta, comandat de partea mecanica a presostatului. Partea mecanica e formata dintr-un platou fix pe care se prind doua suruburi si un platou mobil la un capat, pe care stau cele doua arcuri de reglaj. Sub platoul fix se afla camera de presiune a apei, prevazuta cu o garnitura de cauciuc si un disc metalic. Discul are rolul de a actiona platoul mobil cand presiunea apei creste sau scade.
      Functionare, asa cum am inteles eu: Presostatul vine reglat din fabrica dar, in anumite situatii, trebuie reglat dupa necesitati. Pentru aceasta, se desurubeaza suficient cele doua piulite de reglaj si se porneste hidroforul. Presiunea apei incepe sa creasca. In momentul cand presiunea apei este mai mare decat presiunea constanta a arcului mic, discul metalic de pe garnitura camerei de presiune impinge platoul mobil in sus, rabateaza contactul si decupleaza curentul electric. Se citeste presiune la manometru si incepe reglarea presiunii maxime de decuplare. Daca insurubam piulita surubului mic, presiunea apei creste. Daca desurubam, scade. Se stabileste o presiune maxima de 2,8 bari sau dupa necesitati. Pentru a stabili presiunea minima de cuplare la curent, deschidem un robinet, presiunea incepe sa scada si in momentul cand presiunea apei este mai mica decat presiunea constanta a arcului mare, platoul mobil este impins in jos de arcul mare, rabateaza contactul si cupleaza curentul electric. Se citeste presiunea la manometru si incepe reglarea presiunii minime. Daca insurubam piulita surubului mare, presiunea creste. Daca desurubam, scade. Se stabileste o presiune minima de 1,4 bari sau dupa necesitati. Mai ramane de reglat presiunea pernei de aer dintre membrana de cauciuc din vasul de expansiune si peretele interior al lui la 1,4 bari. Aceasta presiune este necesara pentru a induce in instalatie, deci si la supapa sorbului din fantana, o presiune permanenta de amorsare apompei de apa. Daca presiunea pernei de aer este prea mica, hidroforul porneste des sau porneste dar nu baga apa. Va multumesc pentru rabdare.

  • @marinbalosu1340
    @marinbalosu1340 4 ปีที่แล้ว +1

    Dacă scoți toată apa balonul se va uza prea repede deoarece se cutează (de aia se taie) sub presiunea de aer din vas. În plus, vara, dacă n-ai un consum curent mare de apă, vei consuma apă cam prea caldă. Presiunea din vas trebuie să fie de până la 1,8 bari. Dacă reglezi pornirea la presiune mai joasă vei avea porniri mai dese. Vasul de expansiune nu e nevoie să fie mai mare decât dacă poți folosi o presiune mai mare de 3,5 la 4 bari în rețea.

    • @CatalinCiprian
      @CatalinCiprian  4 ปีที่แล้ว

      1,5b asa vine el setata din fabrica atat am lasat-o si eu 1,5 pornirea 3 oprirea.

    • @marinbalosu1340
      @marinbalosu1340 4 ปีที่แล้ว

      @@CatalinCiprian 1,5 presiune de declanșare și 2,8-4 bari maximă, de oprire (la care mă refeream ca maxime în siguranță), în funcție de rețeaua de apă (diametrele conductelor, materialul lor și siguranța îmbinărilor.

  • @gheorghebueac3585
    @gheorghebueac3585 4 ปีที่แล้ว

    Cătălin, de cind l-am instalat si pînă joi a mers fara probleme.

    • @CatalinCiprian
      @CatalinCiprian  4 ปีที่แล้ว

      Deci ori pierde apa pe undeva o conducta sparta ori pompa e dusa sau presostatul.
      Chiar daca membrana era sparta tot trebuia sa decupleze

  • @ionellupu3943
    @ionellupu3943 2 ปีที่แล้ว

    Bună ziua, trebuie băgat presiune atât cât scrie pe butelie( 1,5 sau 2 bari )apă va curge în jur de 7-8 litri,nu vei avea niciodată 24

  • @ydravlikos234
    @ydravlikos234 5 ปีที่แล้ว +1

    Salut, dupa cate stiu eu, vasul de expansiune vine deja cu o presiune prestabilita de fabricant. Pe cutie sau in manual scrie cat rezista si presiunea prestabilita. Acum depinde de fiecare situatie, fiecare hidrofor la ce presiune e pus sa mearga. Daca merge la o presiune de 2,5 bari, in vas trebuie sa ai undeva la 2,1 2,2 bari. Poate gresesc, dar noi aici pe sistemul acesta mergem.

    • @CatalinCiprian
      @CatalinCiprian  5 ปีที่แล้ว

      Da asa este vine cu o presiune de 1,5 bari

  • @gheorghebueac3585
    @gheorghebueac3585 4 ปีที่แล้ว

    Nu stiu ce sa zic la pierdere de apa ar trebui ca la îmbinare sa iasa apa din pămînt dar nu iese

  • @iuliiuli4897
    @iuliiuli4897 3 ปีที่แล้ว

    Sau cat trebuie?

  • @catalinmoraru1854
    @catalinmoraru1854 2 ปีที่แล้ว

    E normal să nu scoată toată apa din moment ce scade presiunea pentru ca cuplează presostatul presostatul are rolul să țină o presiune cat de cat constanta daca nu ar porni nu ai avea o presiune anume la fel am si eu la 6 litri pornește

  • @mihaim8935
    @mihaim8935 3 ปีที่แล้ว +1

    1. Trebuie băgată presiune mai mare decât presiunea la care pornește hidroforul.
    2. Aerul băgat în hidrofor se pune si el, adică nu mai ai 24L de apă în hidrofor.

    • @CatalinCiprian
      @CatalinCiprian  3 ปีที่แล้ว

      Am inteles.
      Daca tot te pricepi la astea, vreau sa te intreb daca pot pune 2 vase de expansiune in serie de 24 litri ? si daca mai este necesar acel racord care ar atenua asa zis efectul lovitura de berbec.

  • @gabrielbujor7372
    @gabrielbujor7372 6 ปีที่แล้ว

    Baga mai mult aer e mare vasul si mai faceti o proba apasati unde bagati aer cu cv sa vezi daca ese aer daca ese apa in loc de aer e sparta besica

    • @CatalinCiprian
      @CatalinCiprian  6 ปีที่แล้ว

      Am mai spus si la altcineva , am bagat aproape 2,5 bar si am avut acelas rezultat , maxim 5 6 litrii. dupa care porneste pompa. Am verifica nu e sparta membrana , iese aer pe la ventil.

  • @FreddyHFK
    @FreddyHFK 5 ปีที่แล้ว +1

    Eu folosesc două vase de 50L montate în paralel la același nivel și cu aceeași presiune în perna de aer și am aproximativ 24L de apă între porniri (presiunea de aer o faci la 90% din presiunea minimă ce o setezi în presostat pentru pornire, iar pentru oprire setezi dublu; iar presiunea de pornire este după câtă presiune dorești să ai în punctul cel mai înalt al instalației - cam așa ai raportul cel mai bun). Pe scurt 6Litri dintr-un vas de 24 este bine.

    • @johnnyjohn9134
      @johnnyjohn9134 4 ปีที่แล้ว

      Salut, cu setezi presostatul sa pornească la o anumită presiune?! La mn nici când ajunge la 0 nu pornește! Am tot strâns la șuruburi de cred că l am dat peste cap. Am observat că atunci când nu mai e nicio picătură de apă pe conducte declanșează presostatul. Cum aș putea să l setez sa nu scadă sub 0,5bari?

    • @laurentiuenache6640
      @laurentiuenache6640 4 ปีที่แล้ว

      Ce presiune trebuie sa fie la un vas de 50 L

    • @FreddyHFK
      @FreddyHFK 4 ปีที่แล้ว

      @@laurentiuenache6640 dacă te referi la presiunea aerului din vas, ea trebuie să fie 90% din presiunea minimă la care setezi presostatul (adică un pic mai puțin decât presiunea de pornire a pompei). Atenție presiunea de aer se face cu vasul deconectat din instalație, golirea instalației nu este suficientă, uneori poți avea apă pe coloana.

  • @iuliasimion6136
    @iuliasimion6136 4 ปีที่แล้ว

    Dacă nu declanșează ce tvr sa fac

  • @danydaniel7231
    @danydaniel7231 5 ปีที่แล้ว

    Cu pompa cat aer bag cum stiu ca am destul trebuie sa am robinet deschis cand bag aer?

    • @CatalinCiprian
      @CatalinCiprian  5 ปีที่แล้ว

      1,5 bari trebuie bagati pe acel ventuil deci va trebuie o pompa cu manometru.

    • @pascarlat274
      @pascarlat274 4 ปีที่แล้ว +1

      Da, trebuie sa fie deschis robinetul -consumator , când se bagă presiune in vas expansiune.
      Presiunea o verifici cu un aparat manual ,, control presiune ,, și după ce bagi presiune , pui la ventilul vasului expansiune , prin apăsare manuală . Dacă arată mai mult de 1,5 bari , mai scoți apăsând pe tija de la ventil. Asta e ordinea, succes.
      Te salut din Suceava.

    • @saptesoapte8267
      @saptesoapte8267 2 ปีที่แล้ว

      salut! multumesc de raspunsuri! 1.5 trebuie bagata indiferent de capacitatea hidroforului? si daca este deschis un robinet, nu o sa iasa pe acolo si presiunea, dupa ce curge apa, cum se mai face presiune daca iese aerul bagat. precizez ca este un butoi de inox de bere, fara "basica". multumesc de raspuns!

  • @halaszcarol4207
    @halaszcarol4207 6 ปีที่แล้ว +1

    Se poate face un compresor de aer din vasul de expansiune de 24 de litrii?

    • @halaszcarol4207
      @halaszcarol4207 6 ปีที่แล้ว

      Până la ce presiune rezista vasul de expansiune? ????

    • @CatalinCiprian
      @CatalinCiprian  6 ปีที่แล้ว

      Parca scrie pe el 8 sau 10 bari

    • @halaszcarol4207
      @halaszcarol4207 6 ปีที่แล้ว +1

      Catalin Ciprian Mulțumesc pentru răspunsul tău! !!!

    • @zenoviamirodone6112
      @zenoviamirodone6112 4 ปีที่แล้ว

      Aaa.., nepoate, ce pula mea discutăm noi aici și ce întrebi tu?

  • @adiromlak76
    @adiromlak76 6 ปีที่แล้ว +1

    Mini redresor? E compresor de la lidl pt masina si e ok

    • @CatalinCiprian
      @CatalinCiprian  6 ปีที่แล้ว +1

      Romlak Adrian asa am spus mini redredor ? 😁 Da e mini compresor de la lidl

  • @mihaienache5888
    @mihaienache5888 3 ปีที่แล้ว

    Dupa schimbarea membranei la un vas de 50 de litri, ce presiune se baga ?

    • @CatalinCiprian
      @CatalinCiprian  3 ปีที่แล้ว +1

      La 24Litrii trebuie bagat pana in 3 bari el vine pre-incarcat cu 1,5bari.
      La cel de 50Litrii nu stiu cat aer trebuei dar scrie pe el sigur

  • @gabrielcristian505
    @gabrielcristian505 3 ปีที่แล้ว

    Salutare. Cum ai reusit sa aduci compresorul pentru automobil la put? Cum ai schimbat alimentarea? Functioneaza la 220?

    • @CatalinCiprian
      @CatalinCiprian  3 ปีที่แล้ว

      Te referi la minicompresorul auto ?
      Nu , nu merge la 220v e alimentat la o baterie de 12v

    • @gabrielcristian505
      @gabrielcristian505 3 ปีที่แล้ว

      @@CatalinCiprian Ok. multumesc. Credeam ca ai facut o modificare la cablul compresorului.

  • @ioanchiorean2616
    @ioanchiorean2616 6 ปีที่แล้ว +3

    Utilajul cu care faci presiunea este un redresor...??
    Ridica presiunea cu un compresor pana la 1,8-2.1 bati ( fara sa umbli la reglajul presostatului) si urmareste rezultatul!

    • @CatalinCiprian
      @CatalinCiprian  6 ปีที่แล้ว

      Este un minicompresor nu redresor. Da voi incerca si pana la 2 bari

  • @marealupta9906
    @marealupta9906 3 ปีที่แล้ว

    Salut !
    Cum bag aer in vas expansiune ?
    Dau drumul la apa , sau cu apa in vas ?

    • @CatalinCiprian
      @CatalinCiprian  3 ปีที่แล้ว +2

      Salut.
      Opresti pompa golesti sistemul de apa si lasi un robinet deschis.

    • @marealupta9906
      @marealupta9906 3 ปีที่แล้ว

      @@CatalinCiprian mulțumesc

  • @rusioan1009
    @rusioan1009 4 ปีที่แล้ว

    Daca presiunea este de4atm si porneste si cind nu e folosit?

    • @CatalinCiprian
      @CatalinCiprian  4 ปีที่แล้ว +1

      Atunci pe undeva se pierde apa din sistem, urmariti la ce presiune atmosferica porneste.

    • @florinraduta3897
      @florinraduta3897 3 ปีที่แล้ว

      @@CatalinCiprian apa o poate pierde si prin sorbul pompei care nu,
      este la vedere ,sa i-l poti controla vizual ! Dacă nu sint pierderi pe rețeaua de apa sau robinetul,în mod sigur ,sorbul pierde presiunea,si trebuie schimbat !

  • @iliepop4858
    @iliepop4858 3 ปีที่แล้ว

    Cum fac sa am presiune mai mare ? Trebuie alta pompa sau vas de expansiune mai mare?

    • @CatalinCiprian
      @CatalinCiprian  3 ปีที่แล้ว +1

      Presiunea cred ca tine de pompa . Pe fiecare pompa scrie la cati bari lucreaza.
      Se mai poate marii si din presostat.

    • @iliepop4858
      @iliepop4858 3 ปีที่แล้ว

      Mersi

  • @saptesoapte8267
    @saptesoapte8267 2 ปีที่แล้ว

    buna seara! am si eu 2 intrebari va rog, am un vas de presiune facut dintr un butoi de bere de 50l, nu are basica de cauciug, deci perna de aer este direct in contact cu apa, a ramas fara perna de presiune si acum porneste f des pompa (submersibila, de adancime), acum am vazut din comentarii ca pt a reface presiunea, trebuie scoasa apa si lasat un robibet deschis, dar daca las deschis robinetul, dupa ce curge toata apa din instalatie, nu o sa iasa si presiunea pe robinet, trebuie sa inchid robibetul cand fac presiunea? si intrebarea 2., tot 1.6 trebuie pusa presiunea, chiar daca e de 50l? multumesc mult!

    • @CatalinCiprian
      @CatalinCiprian  2 ปีที่แล้ว +1

      Daca nu are membrana atunci nu stiu ce sa zic, presiunea e valabila doar cu membrana deoarece ea se face intre membrana si vas si nu iasa daca robinetu 3 deschis

    • @saptesoapte8267
      @saptesoapte8267 2 ปีที่แล้ว

      @@CatalinCiprian multumesc, poate altcineva din discutie stie....o sa incerc sa fac si cu el deschis si cu el inchis sa vad cum functioneaza, o sa inchid circuitul care duce in casa si las deschis circuitul care duce la gradina, revin👍

    • @saptesoapte8267
      @saptesoapte8267 2 ปีที่แล้ว

      @@CatalinCiprian am lasat robinetul deschis pana a curs apa si a ajuns manometrul de la butoi la 0, dupa a trebuit sa l inchid pt ca nu se mentinea presiunea pe care o bagam cu compresorul. am bagat 1.8 presiune si este ok acum, nu mai pleaca imediat pompa. In consum cu apa deschisa urca presiunea cu pompa pornita pana la 3.8, se opreste pompa si coboara pe masura ce curge apa pana la 1.8 cand iar porneste si urca pana la 3.8. Deci presostatul este setat din fabrica la 2 bari. Problema care este la sistemul asta artizansl cu butoi, din cate vad, este ca daca nu tii pompa in permanenta in priza, si ai de ex sistemul de picurare deschis, curge apa din sistem pana ajunge la 0, nu se opreste la 1.8, si posibil, nu stiu, dar asa pare, pierde iar presiunea, perna de aer, deci asta cred ca este rolul basicii de cauciug sau al supapelor la hidrofoarele din comert.

  • @costicaneagu3679
    @costicaneagu3679 3 ปีที่แล้ว +3

    Mai mare presiunea de 2,2 bari se poate defecta anumite piese la motor sau instalație, cum ar fi
    Presetupa , sau chiar supapă de sens care o poate deforma sau sparge datorită presiunii prea mari...
    Deci :apă max 2,2 bari
    ...aer minim 1,6 și maxim 1,6 bari
    Daca scade presiunea de aer , completezi aerul pînă la 1,6 cum este corect
    ATENȚIE ! ...
    INAINTE DE A BAGA AER IN VASUL DE EXPANSIUNE , SE VA OPRI AL8MENTAREA ELECTRICĂ , SCOATE PRESIUNEA DIN VASUL DE EXPANSIUNE ȘI SE VA DA DRUMUL LA CEL MAI APROPIAT ROBINET , DUPĂ CARE CE VA BĂGA AER
    APA IESE DIN MEMBRANĂ TOATĂ PÎNĂ CE PRESIUNEA DE AER VA FI DOAR MAXIM 1,6 BARI
    APOI INCHIDEȚI ROBINETUL SI REPUNEȚI HIDROFORUL IN FUNCTIE

  • @VerRo23
    @VerRo23 4 ปีที่แล้ว +1

    Va rog da-ti și mi mie un sfat...îmi merge hidroforul non-stop,se oprește doar când îl scot din priza,am schimbat balonul asta și am pus presostat nou,iar hidroforul merge la fel,încontinuu....ce pot sa fac?

    • @CatalinCiprian
      @CatalinCiprian  4 ปีที่แล้ว +1

      Ori exista o pierdere de apa dupa presostat ori nu ati conectat bine presostatul parerea mea. Mai asteptati si alte sfaturi poate sunt mai priceputi printre noi.

    • @VerRo23
      @VerRo23 4 ปีที่แล้ว

      Catalin Ciprian ok,multumesc!

    • @constantinnegoita3054
      @constantinnegoita3054 3 ปีที่แล้ว

      verifica etanseitatea supapei de sens !!

  • @ionellupu3943
    @ionellupu3943 2 ปีที่แล้ว

    Bună ziua, trebuie băgată presiune atât cât scrie pe butelie(1,5 sau 2 bari)va curge în jur de 7-8 litri 24 de litri nu vei avea niciodată,doar să pui o butelie de 50 litri

    • @horhepetrescu
      @horhepetrescu ปีที่แล้ว

      Daca la 24l poti avea 6l intre doua porniri, la 50l vei avea maxim 12l. Oricum nu scapi de neplacerea diferentei prea mari de presiune, vizibila mai ales cand folosesti un furtun in gradina. Ai un avantaj al rezervei de apa mai mari cand nu mai ai energie electrica din retea. Rezolvarea consta in folosirea unui presostat electronic care este mult mai precis si reactioneaza mult mai rapid. In acest caz se poate chiar elimina vasul de expansiune, dar mie nu mi se pare recomandabila aceasta eliminare, desi cunosc o situatie in care pompa functioneaza de cativa ani fara vas.

  • @nicolaebarbu501
    @nicolaebarbu501 4 ปีที่แล้ว

    Dacă pui la socoteala și apa de pe coloana vei vedea ca da cu realitatea de la ieșirea din perna de aer deci apa rămâne pe rețea

    • @CatalinCiprian
      @CatalinCiprian  4 ปีที่แล้ว

      Da, e si asta o treaba , nu m-am gandit si la treaba asta

  • @mihaildaiciulescu2307
    @mihaildaiciulescu2307 2 ปีที่แล้ว

    Postezi atunci cand esti pregatit sa informezi. Asa de dragul '' bessicai'' toata lumea se poate distra pe canal

    • @CatalinCiprian
      @CatalinCiprian  2 ปีที่แล้ว

      Postez arunci cand vreau sa arat ce fac eu in gospodaria mea nu pentru a informa pe nimeni.
      Nu postez pentru ca sunt un expert in ceva anume ci pentru ca imi place.
      Nimeni nu trebuie sa ia de bun nimic de pe yt inainte de a verifica daca este real.

  • @oooo9288
    @oooo9288 2 ปีที่แล้ว

    Si daca scoate mai mult de odata inseamna ca si motorul v-a merge mai mult de 15 sec , deci adio motor in 2 luni

  • @enacheadrian8992
    @enacheadrian8992 4 ปีที่แล้ว

    Salutare sper sa ma poti ajuta cu ceva, deci eu ieri am schimbat o membrana la un vas de expansiune de 100 litri deoarece la 1.5 litri de apa consumati presiunea imi scadea de la 2.5bar la 1.5bar si pompa imi pornea non stop, am schimbat membrana deoarece era fisurata si plina de nisip, am pus membrana noua dar aer nu prea am bagat mult deoarece deja avea aer, in momentul de fata manometrul imi arata ca aerul din vasul de expansiune are o presiune de 1.3bar aprox, mie pompa imi porneste automat atunci cand presiunea scade la 1.5 bar si se opreste cand atinge presiunea de 3 bar.
    ce nu sunt eu sigur este bine sa fie asa? adica presiunea ca si aer din vas sa fie la 1.3 bar si mie sa imi arate presiunea apei la 3 bar? cat aer ar trebui sa bag in vasul de expansiune si cand trebuie sa bag? trebuie sa imi arate presiunea apei pe manometrul respectiv la 0 bar si apoi sa bag aer in vasul de expansiune si apoi sa pornesc iar pompa?

    • @CatalinCiprian
      @CatalinCiprian  4 ปีที่แล้ว +1

      salut, pe vasul meu de 24l scrie ce vine cu o presiune de aer de 1,5b nu știu dacă la cele de100l este aceas presiune citește pe vas. după ce schimbi membrana golești tot sistemul de apa , cu pompa oprita bagi aer prin acel ventil exact cat scrie pe vas după care pornești pompa sa se umple sistemul. eu din Vadu de 24l scot aproximativ 8 10 litrii până să pornească pompa. deci tu ar trebui să scoți macar 35 litrii până să pornească. daca apeși pe venitul și iasă aer atunci e ok daca iasă apa membrana e sparta

    • @enacheadrian8992
      @enacheadrian8992 4 ปีที่แล้ว

      @@CatalinCiprian pe vas scrie o chestie asa : "Pre-charge bar 1.5"
      Golesc tot sistemul de apa in ce sens? adica nu pot pur si simplu sa fac in felul urmator? : Opresc pompa de apa (presiune scade undeva la 0.8 bar din cate stiu) apoi dau drumul la un robinet unde curge apa si scade la 0 bar, apoi opresc robinetul respectiv si bag aer in vas?

    • @CatalinCiprian
      @CatalinCiprian  4 ปีที่แล้ว

      @@enacheadrian8992 golești sistemul in sensul că sa nu mai curgă apa la robineți, apoi presiunea de 1,5 i bagi cu robinetu deschis așa fac eu , nu am incercat cu robinet inchis. In momentul când bagi presiune va ieșii toată apa de pe sistem

    • @enacheadrian8992
      @enacheadrian8992 4 ปีที่แล้ว

      @@CatalinCiprian Multumesc, mi-ai fos de mare ajutor am reusit sa cresc presiunea din vas fara probleme prin metoda ta.

    • @CatalinCiprian
      @CatalinCiprian  4 ปีที่แล้ว

      @@enacheadrian8992 ma bucur

  • @tivadareross2212
    @tivadareross2212 4 ปีที่แล้ว +3

    Eu i-am pus 1,8

    • @costicaneagu3679
      @costicaneagu3679 3 ปีที่แล้ว

      Cum de ai ajuns la tocmai la 1,8 cînd specificațiascr8să de constructorului , este că pe orice corp al vasului de expansiune scrie în clar că nu se pune nici mai mult și nici mai puțin de 1,6 bari , indiferent de ce volum are vasul de expansiune
      Presiunea de aer , este aceeași fie ca este la un vas de expansiune , fie ca este la un cauciuc de bicicletă sau automobil sau ele anvelope de tractoare (pe față) care nu sint expuse tractiunii motoare al utilajului în sine

  • @mihaitatentu163
    @mihaitatentu163 4 ปีที่แล้ว

    Am si eu o intrebare de cand porneste hidroforu merge an valuri

    • @CatalinCiprian
      @CatalinCiprian  4 ปีที่แล้ว

      Adica cu goluri de aer ? verifica membrana sa nu fie sparta apasa pe ventilul din spate daca iasa aer e ok daca iasa apa atunci e sparta

    • @pascarlat274
      @pascarlat274 4 ปีที่แล้ว

      Vezi și supapa de sens unic .( a 2-a verificare )

  • @johnnyjohn9134
    @johnnyjohn9134 4 ปีที่แล้ว +1

    Salut maestre, problema e că la mn se scurge toată apa din instalație și pompa tot nu pornește, ai idee de ce?! Ii dau o presiune de aproape 2 bari, merge ok dar când dau drumul la robinet se scurge absolut toată și pompa nu pornește decât daca apăs eu pe presostat. Presostatul e nou, omega parca se numește.
    Nu am umblat la bășică...

    • @CatalinCiprian
      @CatalinCiprian  4 ปีที่แล้ว +1

      Mda dubios, daca nu ai umblat sa modifici presiunile atunci s-ar putea sa fie defect presostatul , daca modifici presiunea mare sa sti ca chiar daca nu modifici si presiunea mica ea se modifica automat. Daca ai adus presiunea mare la 2 bari aia mica scade singura chiar la sub 1bar. Trebuie sa reglezi presiunile daca ai umblat la ele daca nu atunci e ceva cu presostatul verifica firele si besica din vas sa nu fie sparta. Apesi pe valva aia daca iasa aer e ok daca iasa apa atunci e sparta.

    • @johnnyjohn9134
      @johnnyjohn9134 4 ปีที่แล้ว

      @@CatalinCiprian bășică nu e spartă. Presostatul este bun pt că atunci când modific presiunea mare se modifică doar că mereu scade până la zero și pompa nu pornește decât după ce se scurge absolut toată apa din țevi

    • @CatalinCiprian
      @CatalinCiprian  4 ปีที่แล้ว

      @@johnnyjohn9134 mareste presiunea mica atuncipana ajungi la 1,5bari iar cea mare laso la 3bari

    • @johnnyjohn9134
      @johnnyjohn9134 4 ปีที่แล้ว

      @@CatalinCiprian pai daca nu merge cum sa regleze??! Sau te referi la presiunea din bășică?!

    • @johnnyjohn9134
      @johnnyjohn9134 4 ปีที่แล้ว

      Presiunea mare ajunge și la 7bari

  • @valitoma1423
    @valitoma1423 4 ปีที่แล้ว +2

    daca membrana de cauciuc are 6 litri de unde 24 litri

    • @costicaneagu3679
      @costicaneagu3679 3 ปีที่แล้ว

      24 litri are tot vasul de expansiune , pe cînd interiorul membranei de cauciuc nu are un volum mai mare de 6 l de apă , diferența de volum o va ocupa aierul care întră în vas prin supapa de pe vasul de expansiune avind o presiune a aerului de 1,6 bari
      Cînd schimbi membrana , dacă există ziar este bine să fie scos de sub presiune și scos apa din vas
      După montarea membranei cu o pompă introduci ziar în vas la 1,6 bari apoi poți monta la pompa de apă , după o verificare într-un bazin cu apă ,a vasului de expansiune , exact cum se verifică o cameră de bicicletă sau de automobil
      Dacă da aer pe oriunde prin partea metalică nu este indicat al monta ...
      Dacă dă aer pe artificiul de montare al pompei , spre presostat , înseamnă că nu este ceva în regulă cu membrana
      Dacă este bine o mîncați la locul ei să își facă treaba...

  • @francescotogan179
    @francescotogan179 4 ปีที่แล้ว

    De ce hidroforul imi merge in șuturi?? Am incercat sa i bag presiune cu pompa de bicicleta si apoi am bagat compresorul si nu se mai ridica acul deloc si l am bagat in priza si a inceput sa bage in suturi

    • @CatalinCiprian
      @CatalinCiprian  4 ปีที่แล้ว

      pompa nu mai face presiune, besica din vas e sparta.

    • @francescotogan179
      @francescotogan179 4 ปีที่แล้ว

      @@CatalinCiprian besica doar i am schimbat o de curand

    • @francescotogan179
      @francescotogan179 4 ปีที่แล้ว

      @@CatalinCiprian dupa am scos presiunea bagata si nu am facut asa

    • @CatalinCiprian
      @CatalinCiprian  4 ปีที่แล้ว

      Verifica pompa poate e crapata. Apasa pe ventilu de la vas daca iasa apa e sparta besica. Altceva nu stiu ce sa zic

    • @pascarlat274
      @pascarlat274 4 ปีที่แล้ว +3

      Salut Francesco. Ca idee , pentru a crea presiunea necesară în vasul de expansiune, mai întâi golești tot vasul de apă (să fie gol) prin robinetul deschis. Pui pompa la ventilul vasului de expansiune și pompezi, astfel că la fiecare pompare se va auzi un tiuit și apă va curge la robinet. Faci mișcările astea până nu mai iese apă.
      Până aici e ok , apoi , tot cu robinetul deschis , continuii să bagi cu pompa aer in vas expansiune până la 1,5 .bari.
      Acul de la manometrul presostatului nu arată presiunea din vas. Are alt rol.
      Presiunea din vas, o măsori cu un aparat manual ,,control presiune,, .
      ,,Suturile,, de care spui , apar deoarece nu mai ai presiune aer in vas .
      Salutare din Suceava.

  • @georgedaniel1432
    @georgedaniel1432 4 ปีที่แล้ว

    Salut! Am facut presiunea pernei de aer la 1,5 bar asa cum este specificat pe eticheta de pe hidrofor. Aparent merge bine. Spun aparent pentru ca ma confrunt cu o mica "ciudatenie". Daca las sa curga toata apa din hidrofor (cu el scos din priza) si manometrul de pe presostat e pe zero... Cand il bag in priza, din prima secunda, manometrul "sare" direct la 1,5 bar si incepe sa urce pana la 3 bar, cand presostatul decupleaza tensiunea. Nu ar fi trebuit ca acul sa urce cat de cat constant, de la zero la 3 bari?

    • @CatalinCiprian
      @CatalinCiprian  4 ปีที่แล้ว

      Cred ca e ok, la fel face si la mine daca acu e pe 0 sare la 1,5 apoi urca treptat.

    • @savasilviu3194
      @savasilviu3194 4 ปีที่แล้ว +4

      Asa este normal, cand pompa de apa este oprita, presiunea de pe manometru este 0. Cand pompa porneste si impinge apa, i se opune presiunea din vasul de expansiune care are are deja 1,5 bari. De aceea se intampla acest fenomen.

  • @chiricamarius1649
    @chiricamarius1649 3 ปีที่แล้ว

    La ce presiune trebuie sa fie normal ?câți bari

  • @mihaienache5888
    @mihaienache5888 3 ปีที่แล้ว

    Ai umplut mai intai vasu cu aer sau cu apa?

    • @CatalinCiprian
      @CatalinCiprian  3 ปีที่แล้ว +1

      Pui vasul in sistem si golesti sistemul de apa deci si vasul.
      Apoi incarci cu aer

    • @mihaienache5888
      @mihaienache5888 3 ปีที่แล้ว

      @@CatalinCiprian da, dar bagand prima data aer intre pereti si membrana, nu se strange membrana neavand unde mai intra apa, sau intra apa dar putina?

    • @CatalinCiprian
      @CatalinCiprian  3 ปีที่แล้ว

      Nu se strange.
      Faceti asa cum v-am spus ... aerul dintre vas si membrana are 2 beneficii ... tine membrana departe de peretii vasului si goleste total apa din membrana. Or mai fi si alte beneficii.

    • @mihaienache5888
      @mihaienache5888 3 ปีที่แล้ว

      @@CatalinCiprian ok, multumesc !

  • @gheorghealexandru4300
    @gheorghealexandru4300 4 ปีที่แล้ว

    Va salut!
    Presiunea pernei de aer dintre membrana de cauciuc din vasul de expansiune si peretele interior al vasului este necesara pentri a mentine pompa amorsata. La supapa sorbului din fantana trebuie aceasta presiune. Daca presiunea aceasta este prea mica, pompa porneste prea des sau porneste si nu baga apa la robineti.
    Eu am postat pe Facebook despre ,, Reglarea presiunii la un hidrofor de 24 l'' pentru ca m-am intalnit la hidroforul meu cu aceste probleme si am dorit sa cunoasca cei interesati experienta mea.
    Va multumesc!

  • @fabianghitoiu5098
    @fabianghitoiu5098 2 ปีที่แล้ว

    am si eu hidrofor si bate acul pe 2 la ceas si nu se opreste din ce cauza este?

    • @CatalinCiprian
      @CatalinCiprian  2 ปีที่แล้ว

      Verificati daca nu cumva membrana din interior este sparta apasand pe ventilul vasului , daca iasa aer e ok daca iasa apa e sparta.
      Daca nu e sparta opriti pompa scoateti toata apa din sistem lasati robinetii deschisi si bagati aer prin acel ventil pana la 1,5 bari. Apoi inchideti robinetii si umpleti sistemul de apa.

    • @fabianghitoiu5098
      @fabianghitoiu5098 2 ปีที่แล้ว

      @@CatalinCiprian te inteleg perfect besica este buna nu iese apa dar eu nu am robineti

    • @fabianghitoiu5098
      @fabianghitoiu5098 2 ปีที่แล้ว

      scot tot aerul din el?

    • @fabianghitoiu5098
      @fabianghitoiu5098 2 ปีที่แล้ว

      tin apasat pe valva pana iese tot si dupa bag iara ?

    • @CatalinCiprian
      @CatalinCiprian  2 ปีที่แล้ว

      Daca nu ai robineti si folosesti direct apa din el nu e nici o problema am crezut ca il folosesti pentru instalatia casei.
      Nu mai scoate atunci nici un aer din el doar goleste membrana de apa apoi baga aer pe valva aia 1,5 bari.
      Daca nici asa nu se opreste atunci pompa are pronelema nu mai face presiune ori e crapata ori e defecta.

  • @nicudarie9504
    @nicudarie9504 5 ปีที่แล้ว

    Buna ziua. De ce hidrforul meu nu reuseste sa faca mai mult de 2 atmosfere?

    • @CatalinCiprian
      @CatalinCiprian  5 ปีที่แล้ว

      Salut, verifica daca membrana din vasul de expansiune nu este sparta , verifica daca presostatul este setat la macar 3bari presiunea mare.

    • @nicudarie9504
      @nicudarie9504 5 ปีที่แล้ว

      @@CatalinCiprian , am verificat si membrana si presostatul dar cred ca pompa are o problema si nu reuseste sa faca presiune. Mentionez faptul ca am desfacut-o si corpul pompei prezinte cateva fisuri.

  • @chiriecimarian3270
    @chiriecimarian3270 3 ปีที่แล้ว

    Salut
    Presiunea la apa nu este stabila scade și creste.

  • @dimitricringus9375
    @dimitricringus9375 2 ปีที่แล้ว

    Maristella presiune din pressostat.

  • @bogdanpop3615
    @bogdanpop3615 4 ปีที่แล้ว +3

    Cam incurci termenii. Vas de expansiune, redresor:))

    • @CatalinCiprian
      @CatalinCiprian  4 ปีที่แล้ว

      Ce anume am încurcat? Cu mini redresorul am băgat aer în vasul de expansiune

    • @robydany8749
      @robydany8749 4 ปีที่แล้ว +9

      @@CatalinCiprian "dispozitivul" cu care bagi aer in vas se numeste compresor.

  • @costicaneagu3679
    @costicaneagu3679 3 ปีที่แล้ว

    Cătăline ! ...
    Nu crezi că greșești cu cei 24 litri de apă?...
    Scoate membrana (beșica , cum spui tu) apoi pune apă în membrană și vezi cîți litri întră în ea
    Mai mult de 3 l sau 3,5 l nu întră sigur
    Păi mai mult de 6 litri nu se poate încărca membră , deoarece nu se poate întinde la 24 litri

  • @gheorghebueac3585
    @gheorghebueac3585 4 ปีที่แล้ว

    Nu cred ca e POMPA este nou are doar 2 luni de CIND l-am cumparat

    • @CatalinCiprian
      @CatalinCiprian  4 ปีที่แล้ว

      Se mai intampla sa vina asa din fabrica.
      A facut asa de cand ati pus pompa cea noua ?
      Verificati presostatul

  • @iphonepho9621
    @iphonepho9621 6 ปีที่แล้ว

    pai mai baga aer ioane :)

    • @CatalinCiprian
      @CatalinCiprian  6 ปีที่แล้ว

      lol:) pai cat ba ca din cate am cititi se baga 90% din presiunea de pornire a pompei , adica 0.9x1,5 - 1.35bari

    • @iphonepho9621
      @iphonepho9621 6 ปีที่แล้ว

      baga pana face poc :))

    • @CatalinCiprian
      @CatalinCiprian  6 ปีที่แล้ว

      Aia da vasilica :) ca numa de schimbat bashici nu am chef :))

    • @mariusvfp
      @mariusvfp 6 ปีที่แล้ว

      termino nu face poc , daca vasul e nou tine ,el a fost testat pana la 8,1 bari.

  • @marianstefan2657
    @marianstefan2657 2 ปีที่แล้ว

    Beșică ai zis ????
    ,,nu intra pe sistem" ???
    🤣🤣🤣🤣🤣

  • @catalinstuparulcatalinstup3918
    @catalinstuparulcatalinstup3918 5 ปีที่แล้ว +1

    Sa nu bagi prea mult aer cu redresorul ca spargi besica!

  • @danutneacsu8526
    @danutneacsu8526 4 ปีที่แล้ว

    Miniredresor? Mă beșică! De ce ai umblat și la presostat? I-ai pus-o la beșică.

    • @CatalinCiprian
      @CatalinCiprian  4 ปีที่แล้ว

      Unealta cu care bag presiune in bashica se numeste mini compresor :)) daca am zis redresor asta e mai greseste si omu :)

  • @Adam-bw4lw
    @Adam-bw4lw 6 ปีที่แล้ว

    Baga 1.8-2bar in rezervor

    • @CatalinCiprian
      @CatalinCiprian  6 ปีที่แล้ว +1

      Deci sa mai bag aer pana la 1,8-2 ziceti. Nu afecteaza cu nimic presiunea apei ? adica nu trebuie modificata si presiunea apei cumva ? pornirea si oprirea ?

    • @CatalinCiprian
      @CatalinCiprian  6 ปีที่แล้ว +1

      Nu cred ca ar fi ok 2 e posibil sa blochez presostatul ce parere ai ?

    • @Adam-bw4lw
      @Adam-bw4lw 6 ปีที่แล้ว

      Nu, la mine asa merge de cand am cumparat pompa,la mine pompa se opreste la 3bar eu pot sa scot in jur de 15-17L dintrun tank de 20L

    • @CatalinCiprian
      @CatalinCiprian  6 ปีที่แล้ว

      Hmminteresant, voi incerca si 1.8-2 cu riscu sa sparg besica sau sa blochez presostatul si voi revenii

    • @Adam-bw4lw
      @Adam-bw4lw 6 ปีที่แล้ว

      Are trebui se scrie si pe tank presiunea de umflare recomandata

  • @iuliiuli4897
    @iuliiuli4897 3 ปีที่แล้ว

    1,5 bari este la toate hidrofoarele?

    • @CatalinCiprian
      @CatalinCiprian  3 ปีที่แล้ว +2

      1,5 vine din fabrica dar poti baga pana la 3