  • Derinkuyu Submersible Pump Panel Installation Liquid Level Relay and Floater Connection How to Install Float.
    At the same time, I connected a liquid level relay to the submersible pump and also made a floater connection. As long as there is water in the well, the submersible pump will operate and the float will be active as long as the motor does not draw high amps and discharge thermal power. If the tank is full, it will open the circuit by pressing the switch with the marble in the floater and cut the energy going to the a1 phase coil leg of the contactor. And naturally the closed contacts of the contactor will open and the motor will stop.
    I both explained with the start stop connection and made the connection by canceling the control circuit.
    When the start stop connection is canceled, you need to get the energy to the common end of the float from the 96 NC contact of the thermal, naturally you have to give the 95 NC contact neutral. Otherwise, the thermal will not work.
    "How to Connect Deep Well Submersible Pump Liquid Level Relay and Floater"
    floater,
    #diver
    liquid level,

ความคิดเห็น • 258

  • @feyzullahihtiyar1051
    @feyzullahihtiyar1051 ปีที่แล้ว +1

    emeğine sağlık çok rahat bir anlatim olmuş yormadan teknik bilgiye boğmadan bilgilendiriniz teşekkür ederim

  • @yasinyldz5381
    @yasinyldz5381 3 ปีที่แล้ว

    gercektenn cokkk faydali Allah razi ollsun hepsini coook iyi anladim valla size ne kadar teşekür etsek az. Allah yolunuzu bahtinizi acik etsin🤗🤗

    •  3 ปีที่แล้ว +1

      Teşekkürler.

    •  3 ปีที่แล้ว +1

      Müşteriye anlatır gibi anlattım 🙂🙂

  • @bilalkokmaz8630
    @bilalkokmaz8630 2 ปีที่แล้ว +1

    Sizin sayenizde elektirkçi dükanı açtım çok teşekkür

    •  2 ปีที่แล้ว

      Şaka yapıyorsun 🙂

    • @bilalkokmaz8630
      @bilalkokmaz8630 2 ปีที่แล้ว +1

      @ evet zaten biliyordum çocukken çıraklık yapmıştım ama sizinde emeğiniz var çok

    •  2 ปีที่แล้ว

      Başarılar

  • @mehmetcetintas4541
    @mehmetcetintas4541 3 ปีที่แล้ว +1

    Kardeşim eline emegine sağlık

    •  3 ปีที่แล้ว

      Teşekkürler. Ne işle meşgulsünüz acaba

  • @hudayikoc7416
    @hudayikoc7416 ปีที่แล้ว +1

    Elinize sağlık

  • @dogadakiyasam6817
    @dogadakiyasam6817 3 ปีที่แล้ว +2

    Hocam ellerinize sağlık Bi çok arızayı sizin sayenizde giderdim varolun videolarınız çok faydalı

    •  3 ปีที่แล้ว

      Teşekkürler. Saygılar

    • @dogadakiyasam6817
      @dogadakiyasam6817 3 ปีที่แล้ว

      Instagramda'da paylaşım yapıyor musunuz ordan da takip etmek isterim

    •  3 ปีที่แล้ว +1

      Sosyal medyayı kullanmıyorum, yinede teşekkür ederim 👍🖐️. Bizim için videolarımıza like yapman yeterli

    • @dogadakiyasam6817
      @dogadakiyasam6817 3 ปีที่แล้ว +1

      @ her zaman hocam

    • @gurkanguler1720
      @gurkanguler1720 3 ปีที่แล้ว

      Ustam kolay gelsin 380 ile calisan bahçemizde bir pompa mız var start stop anahtar ile kontrol ediyoruz depo dolduğu zaman pompa dursun diye flatör takmak istiyorum 380 ile çalışan böyle bir video yapabilirmisiniz teşekürler

  • @mehmetcopur7130
    @mehmetcopur7130 3 ปีที่แล้ว

    Emeğine sağlık 👏👏

    •  3 ปีที่แล้ว

      Teşekkürler

  • @muhammeddemir4709
    @muhammeddemir4709 2 ปีที่แล้ว +1

    Eline sağlık kral

    •  2 ปีที่แล้ว +1

      Teşekkürler 👍

  • @anarqasimov3069
    @anarqasimov3069 4 หลายเดือนก่อน

    SUPER ABİ VAR OL

  • @parakazanmakisteyenler
    @parakazanmakisteyenler 3 ปีที่แล้ว +1

    Kafam Yandı hocam😂😂

    •  3 ปีที่แล้ว +1

      Yanması güzeldir. Yanmayınca problem.. Güneş görmeyen ağaç meyva vermez.. 🙂

  • @sedatcay4968
    @sedatcay4968 3 หลายเดือนก่อน +1

    Teşekkürler.

  • @salihylmaz6247
    @salihylmaz6247 8 หลายเดือนก่อน

    Süpersin

  • @ismailsaglam8431
    @ismailsaglam8431 2 ปีที่แล้ว +1

    Hocam güzel bilgiler verdin sağolasın ama çok karıştı. Star stopluyu ayrı, tam otomatik sistemi ayrı anlatsan benim gibi az bilgili arkadaşlar için daha verimli olur diye düşünüyorum teşekkürler

    •  2 ปีที่แล้ว

      th-cam.com/video/8vW6hQCYAJU/w-d-xo.html

    •  2 ปีที่แล้ว

      Bu da otomatik ama güç Devresi yok. Sadece kumanda Devresi var. Zaten önemli olan kumanda Devresi

  • @cetindegirmenci1677
    @cetindegirmenci1677 3 ปีที่แล้ว +1

    Diğer ucu ikaz lambasında kullanabilirsin mesela su yok ikaz lambası yakar

    •  3 ปีที่แล้ว

      Aynen. Olabilir

  • @cemtopkaya3422
    @cemtopkaya3422 ปีที่แล้ว

    48 Volt motor ve 4 panel için bu sistemi kurmak istersem hangi model ve markaları kullanabilirim? Elbette farklı markaların ürünleri olacaktır ancak en azından bir liste olursa elimde muadil bulmam daha kolay olacaktır. Şimdiden teşekkürler.

  • @idrisardc77
    @idrisardc77 2 ปีที่แล้ว

    Hocam kondansatörü yardımcı sargıya röle üzerinden veya merkezkaç siwic i üzerinden seri olarak bağlanıyor diye hatırlıyordum bu bilgi yanlismi acaba

  • @eyuptemiz9863
    @eyuptemiz9863 18 วันที่ผ่านมา

    Hocam flatör olmadan rölenin kapalı ve açık uçları üzerindende aynı sistem kurulabilirmi yada benmi yanlışım

  • @kutbettinbay855
    @kutbettinbay855 2 ปีที่แล้ว +1

    Ustam zahmet olmasa 3 fazıda anlatabilirmisin bizimki köy su deposudur ona göre bir video 😊

    •  2 ปีที่แล้ว

      Üç fazda kumanda Devresi bunun aynısı. Güç Devresi Üç faz olacak

  • @bunyamingunes7303
    @bunyamingunes7303 ปีที่แล้ว

    Emeğinize sağlık. Çok yararlandım.Depodan tanka su basmıyor. Kontaktör un otomatik açıp kapatan düğmesine basılı tutarsam suyu basıyor. Neden olabilir.Cok teşekkürler.

    •  ปีที่แล้ว +1

      Kardeş görmeden bakmadan, dokunmadan bir şey söyleyemem.. Uzaktan bir şey söylemem size vi cihaza zarar verebilir

  • @recepayyldz6072
    @recepayyldz6072 2 ปีที่แล้ว +1

    Benim dalgıç motorunun üzerinde şamandıra var kablosu ise siyah yeşil beyaz bu ne anlama geliyor siyah faz versem diğer iki uç nötr ve kondansatör bacağımı ?

    •  2 ปีที่แล้ว

      Şamandıra dediğiniz flatör demi

  • @ufukbulut9757
    @ufukbulut9757 2 ปีที่แล้ว +1

    Hocam flatör depo doluyken şebeke suyu kesildiginde yukarıda kaldığı için çalışmıyor yukarıda mi çalışması lazım aşağıdaki flatörün

    •  2 ปีที่แล้ว

      Flatörün açık kontağı kullanılmış ise tankı doldurmak için kullanılır yani tank dolunca flatör yukarıya çıkar motor durur. Tankı boşaltmak için de kapalı kontağı kullanılır.. Sistem aynı

  • @fatihbakar926
    @fatihbakar926 3 หลายเดือนก่อน +1

    Elinize sağlık hocam benim zamanlı bir anahtar bağlantı şekline ihtiyacım var yani 1 saat aksın yada 2 saat aksın gibi bi komut vermek istiyorum fırınlardaki zaman ayarlama anahtarı gibi mümkün mü?

    •  3 หลายเดือนก่อน

      Astronomik zaman saati kullanarak yapabilir siniz

  • @recepsahin9535
    @recepsahin9535 ปีที่แล้ว

    İyi gunler bunu solar 24 volt dc icin yapabilirmiyiz

  • @emrullahcabuk9715
    @emrullahcabuk9715 2 ปีที่แล้ว +1

    Slm hocam öncelikle emeğinize sağlık çok güzel anlatmissiniz benim bir sorum vardı bu elektorotlarin sağlam olup olmadığını ölcebilirmiyiz

    •  2 ปีที่แล้ว

      Teşekkürler. Benim yaptığım uygulamayı yapıyorsa elektrod lar sağlam demek

    • @emrullahcabuk9715
      @emrullahcabuk9715 2 ปีที่แล้ว

      @ benim çalıştığım yerde kuyu var çalışmıyor bugün baktım su seviye rolesi out vermiyor su yok ışığı yanıyor acaba dedim elektrotlar bozuk olabilirmi nasıl olceriz emin olmak için

    •  2 ปีที่แล้ว

      @@emrullahcabuk9715 sıvı Seviye rölesinin üzerindeki L, U, B klemens leri sağlam bağlı mı onu Bi kontrol edin ondan sonra, malumunuz elektrodlar kuyunun içinde, kuyunun içindeki motor çıkacak ve küçük bir su kabının içinde sağlamlık testi yapılacak. Tabi kuyu da su olmayabilir, boşu boşuna çıkarmış olursunuz ama en azından öyle Bi şey varsa suyun olmadığını da tespit etmiş olursunuz. Birde pano üzerinde enerji akışı kesintisiz her yere gidiyor mu buda kontrol edilmeli. Örneğin röle ye enerji tam geliyor mu. Bundan dolayı da aut vermiyor olabilir

    • @emrullahcabuk9715
      @emrullahcabuk9715 2 ปีที่แล้ว +1

      @ teşekkürler hocam bilgiler için l u b uçları bağlı bir gevseklik yok rolenin on ışığı yanıyor yani enerji geliyor zaten kuyu yaklaşık 2 senedir kullanılmıyor ama neden kullanılmıyor bilen yok pompayi olctum sağlam

  • @SinanYlk
    @SinanYlk หลายเดือนก่อน

    Kardes emegine saglik bana direk eve su basacak pano nasil yapilir ve hidrafor olmadan

  • @halimyilmaz3527
    @halimyilmaz3527 2 ปีที่แล้ว

    Kondasadör ler nörlenmi çalışıyor acaba

  • @emretovic
    @emretovic 3 ปีที่แล้ว

    bilge hocam bu derin kuyu dalgıç pompalar basınç düşüşü prensibine göre de çalışıyorlar mı? yapacağım su kuyusuyla dolduracağım su deposu arasında yüz metre mesafe var. su deposuna elektrik flatörlü seviye kontrol vanası koyacağım. flatör vanayı açacak ve depo dolmaya başlayacak. ama pompa bu sırada manuel mi devreye sokulması lazım yoksa vana açılınca doğal olarak hattaki basınç da düşeceği için basınç düşüşüyle birlikte pompa da devreye girer mi, o detayı tam bilmiyorum. yardımcı olursan sevinirim.

    •  3 ปีที่แล้ว

      Manuel ayarlar iseniz tank doluncaya kadar dalgıç çalışır, tank dolunca flatör enerjiyi keser dalgıç durur. Ama sıvı seviye rölesi de olması gerekiyor kuyuda. Çünkü su bittiği halde tank dolmadığı için hala çalışırsa dalgıç yanar.

    •  3 ปีที่แล้ว

      Bunu Manuel de yapabilirsiniz yani kendiniz start yaparsınız tank dolana kadar dalgıç su olduğu sürece çalışır tank dolunca flatör motoru durdurur. Otomatik de yapabilir siniz. Kuyuda su olduğu sürece ve tank boş olduğu sürece motor Sürekli çalışır durur.

    •  3 ปีที่แล้ว

      th-cam.com/video/v8Uq0eh-BfA/w-d-xo.html
      Bunu da izleyebilir siniz. Dalgıç pompa susuz çalışınca neden yanar

  • @sebahattinarslan8117
    @sebahattinarslan8117 2 หลายเดือนก่อน

    Flatorun kablosunu dogrudan motorun kalosun baglasam bir sikinti olur mu

  • @addyokk662
    @addyokk662 3 ปีที่แล้ว +1

    Hersey guzel ama cekim yaparken biraz aydinlatma olsaydi daha iyi olurdu kameranin yanina bir isik goruntu daha net olabilir

    •  3 ปีที่แล้ว

      Evet ama imkanlar malesef :(

  • @benyaparim.
    @benyaparim. 3 ปีที่แล้ว +1

    Sıvı seviye rolesi olmadan sadece flatörü nasıl bağlayabiliriz?Depo boşaldıkça çalışıp dolduracak dolunca duracak şekilde.

    •  3 ปีที่แล้ว

      Sadece flatör bağlı kalacak nötür üzerinden.. Yani aynı bağlantı. Sadece sıvı seviye yi iptal edeceksiniz veya olmadığını düşünün

    •  3 ปีที่แล้ว

      th-cam.com/video/zTx4RIZxaB4/w-d-xo.html

  • @orhanguler7123
    @orhanguler7123 2 ปีที่แล้ว

    Merhaba ustam.oncelikle bizleri aydinlattiniz icin teşekürler..size bi sorum olacak.kuyumuzda bu gosterdiniz panodan var.kuyumuz 3 dkka su basiyor(yesil yaniyor)duruyor.daha sonra 2 saat su bitti (sarı isik)yaniyor..biz kuyuda su
    oldunu düşünüyoruz.ariza nedir sizce?

    •  2 ปีที่แล้ว

      İhtimalleri söylüyorum. Motor filtresi tıkanmış olabilir. Fan yani kademe kum ile tıkanmış olabilir.. Motoru çalıştırıp stop ettikten sonra hemen çalıştırmayın Bi 15 dk bekleyin. Çünkü fan içindeki kumlu suyu tahliye etmeden start yaparsanız fan kumlu suyu çekmekte zorlanır ve tıkanır veya motor sargı kablo su kopar yanar

    •  2 ปีที่แล้ว

      Dalgıç pompalar çok nazik kuyu temiz olmak zorunda. Bilinçli kullanılmak zorunda. İkinci bir kişi tarafından kullanılmamalı

    • @orhanguler7123
      @orhanguler7123 2 ปีที่แล้ว +1

      @ teşekkürler

  • @serdarcangir5466
    @serdarcangir5466 3 ปีที่แล้ว +1

    Hocam ellerinize sağlık panoda su seviyesini nasıl yukseltebilirim şu an benim sondaj kuyuda su depoya az aktarıyor panoda bunu nasıl düzeltebiliriz

    •  3 ปีที่แล้ว

      Depoya su az mı geliyor, kuyunun içindeki su seviyesi yükselmez

    • @serdarcangir5466
      @serdarcangir5466 3 ปีที่แล้ว +1

      @ hocam şu şekil panoda suyun akış hızını yükseltebilir miyim

    •  3 ปีที่แล้ว

      Kuyuda ki suyu çokluğuna göre motor takılır sisteme.. Şimdi yüksek beygir li pompa taksan kuyuda su az ise hemen çeker bitirir

  • @ersinkayabas4268
    @ersinkayabas4268 2 ปีที่แล้ว +1

    Biliyorsunuz ne demek. Videoyu ihtiyacı olan kişi öğrenmek için seyretiyor.

    •  2 ปีที่แล้ว

      Eksik kalan yerleri diğr videolarımı izleyerek tamamlayabilirsiniz

  • @siyarylmam583
    @siyarylmam583 ปีที่แล้ว +1

    Abi merhaba senin sayende çok şeyi yaptım. Bu videonun aynısını kendi koyuma yapacam su bitti ışığını nasıl baglayacam

    •  ปีที่แล้ว

      th-cam.com/video/VbwoYanjBtw/w-d-xo.html

  • @emretalum5612
    @emretalum5612 3 ปีที่แล้ว +1

    Abi peki sıvı seviye rolesiz ve elektrotsuz sadece flatörle calışırmı bu sistem

    •  3 ปีที่แล้ว

      Flatör ile çalışır ama kuyuda suyun bittiğini nasıl tespit edecen

    • @vefaaltun3796
      @vefaaltun3796 6 หลายเดือนก่อน

      Bzm kuyu derin kuyu değil kepçeyle açılan yüzeysel kuyu pompam sadece susuz çalışmasın diye flatör yeterlimi seviye bana gerekli değil çünkü suyu görüyorum hazır satılan panolarda sıvı seviye rölesi hariç diğer ürünler mevcutmu röle olsun kontaktör olsun pahalı pano daha uygun geliyor tabi hepsi mevcutsa konu uzadı seviye röle olmadan flator şu bitince pompayı kapatırmı bzm burda koydekilerin hiçbirinde pano sigorta ve kondansatör var şahsi fikrim pano daha iyi cvplarsan sevinirim

  • @exekeen
    @exekeen 3 ปีที่แล้ว +1

    Videolar için çok teşekkür ederim. Ben İnşaat Mühendisiyim, fakat bu işlerden de çok zevk alıyorum. Bir sorum olacak. Kael ke-skr sıvı seviye rölem var. Elektrot bağlantılarını bildim. Fakat anlatımızda kullandığınız üründe bulunan A1, A2, C, NO ve NC yerine bendeki üründe 1, 2, 3, L1 ve N bağlantıları mevcut. Elektrik konusunda da yetersizliğimden iki ürünü birbiri ile ilişkilendiremedim. Bir de ben şöyle bir sistem işletmek istiyorum. (Sıvı seviye rölesinin alt ve orta elektrotlarını kesona daldıracağım. Sadece motoru korumak için, eski bir motor ve flatörü yok. Elektrikli flatörü de depoda kullanmak istiyorum. 1. Depo dolunca kontak açılmalı 2. Keson boşalınca kontak açılmalı 3. Keson orta elektrota gelince kontak kapanmalı) 1, 0, 2 konumları olan bir pako şalterin 1 konumunda SSR ve Depodaki flatör senkron çalışsın istiyorum. Anlattığınız zaten bu. 0 kapalı. 2 konumunda ise depoyu bypass ederek direk kuyudan hortumla sulama yapmak istediğimde Depodaki flatör devre dışı kalarak sadece kesondaki elektrotlara göre çalışmasını istiyorum. Videolarınızdan yardım etmeyi sevdiğinizi anladım:) Ben de uzmanı olduğum konularda çok vericiyimdir. Bana zaman ayırarak yol gösterebilirseniz çok mutlu olacağım. Sistemimde on off butonları yerine 3 konumlu pako şalter olacak sadece. Onun dışında bütün elemanlar bende de var. Bana göre bir video daha çekebilir misiniz? Zira bu konulardan anlayan donanımlı bir teknik elemana ulaşabilmem oldukça zor.

    • @exekeen
      @exekeen 3 ปีที่แล้ว

      Yanlışlıkla oğlumun hesabından yazmışım. Kendi mailim tan.arel@gmail.com

    •  3 ปีที่แล้ว

      Sizdeki motor koruma rölesi olabilir

    •  3 ปีที่แล้ว

      1,0.2 konumlu video yaptım.. Ama yapmak istediğinizi kısaca anlatabilir misiniz.biraz karışık oldu

    • @areltanriogen
      @areltanriogen 3 ปีที่แล้ว +1

      @ Yani termik yerine motor koruma rölesi mi kullanmalıyım?

    •  3 ปีที่แล้ว

      Hayır elinizdeki SıvıSeviye Rölesi değil, Motor koruma rölesine benziyor ondan dedim

  • @ercanbayram8938
    @ercanbayram8938 3 ปีที่แล้ว +1

    Abi nötr üzerinden flatorun ortak ucuna veriyoruz flatorun açık üçünü Kontaktorun a2 bobin ucuna veriyoruz depoya şu dolduğunda no ucu kapanıp a2 ye nötr iletiyor kontaktör u nasıl durduruyor onu anlayamadım

    •  3 ปีที่แล้ว +1

      Evet flatörün ortak ucuna nötür veriyoruz.. Açık kontak yani NO ucunu kontaktörün faz bobin bacağına veriyoruz, bu a1 de olabilir, a 2 de olabilir.. Flatörün içinde misket var tank dolunca flatör yukarı kalkıyor, yukarı kalkınca içinde ki misket sivitch in devreyi açmasını sağlıyor, ve kontaktörün bobin bacağına giden enerjiyi kesiyor

    • @ercanbayram8938
      @ercanbayram8938 3 ปีที่แล้ว +1

      @ ayrı bir nötr veriyoruz ama a2 ye flaşör aşası konumda iken açık kontak su dolunca açık kontak kapanıyor ve yine a2 ye flaşör uzerimd3m nötr gitmiyormu benmi 6anlis anladim

    •  3 ปีที่แล้ว

      Hayır ayrı bir nötür değil... Kontaktörün bobin bacağına gidecek nötürü flatör üzerinden gönderiyoruz.. Yani flatör kontrol mekanizması oluyor

    • @ercanbayram8938
      @ercanbayram8938 3 ปีที่แล้ว +1

      @ şimdi anladım teşekkürler vidyo da ayrıntıyı kaçırmışım sigorta çıkışından kontaktör bobinine bağladığınız notru sokup flaşör üzerinden verdiniz depoyu şu dolarken flatorun kontağı kapalı durumda oluyor şu dolunca flaşör şamandıra yukarı kalkıp kapalı olan kontağını açıyor ve kontaktir bobinine giden enerji kesiliyor

    •  3 ปีที่แล้ว

      Aynen öyle... Teşekkürler

  • @yarentv7059
    @yarentv7059 3 ปีที่แล้ว

    Ya bide şöyle faz koruma,sıvı seviye,zaman röle,zaman saati olan bir pano kurulumunu yapabilirmisin.

    •  3 ปีที่แล้ว

      Faz koruma rölem üç fazlı ondan dolayı tek fazlı pano da kullanamıyorum. Ama diğerleri olabilir

    • @yarentv7059
      @yarentv7059 3 ปีที่แล้ว

      @ olsun sadece görsel olarakta olabilir.calistirman gerekmez.

    •  3 ปีที่แล้ว

      Olabilir

  • @serhatelektrik9309
    @serhatelektrik9309 2 ปีที่แล้ว +1

    Ustam kolay gelsin dün bi arızaya gittim dalgıç motoru var muslukları açtığınız zaman kontaktör çekip şu gelmesi lazım orda tam tersi oluyor panoyu açıyorum musluklar kapalıyken kontaktör sürekli tak tak çekiyo anlayamadım yardımcı olurmusun

    •  2 ปีที่แล้ว

      Hidrofor sistemi varsa tam bilmiyorum ya

    •  2 ปีที่แล้ว

      Basınç şalteri falan kontrol edilmeli

    • @agitgokmen8525
      @agitgokmen8525 2 ปีที่แล้ว

      Basınç şalteri yada swici kontrol etmek lazım

  • @ozgurilhandemiraslan9759
    @ozgurilhandemiraslan9759 2 ปีที่แล้ว +1

    Kaçlık pompa için hazırladınız. Malzeme listesi (özellikleri - ürün kodları amper değerleri vs.) nedir. 1,5 hp ye kadar pompa için nasıl bir malzeme listesi olur? Tşk.

    •  2 ปีที่แล้ว

      Malzemelerin markası önemli. Schneider Siemens veya viko kullanılabilir..

    •  2 ปีที่แล้ว

      Kumanda Devresi sıvı Seviye rölesi için butonlar için amper değeri yok

    •  2 ปีที่แล้ว

      Termiği alırken dikkat edin. 5-9 amper değerleri arasında seçim yapın diğerleri önemli değil

    •  2 ปีที่แล้ว

      th-cam.com/users/shortsdaxUkZCWryA?feature=share
      Bu kanala abone olabilirmisiniz

    • @muhammedsahin7557
      @muhammedsahin7557 2 ปีที่แล้ว

      @ 3 hp 2.2 kw dalgic icin 4-6.3 amper termik aldim yeterli mi acaba

  • @ibrahimcakir7390
    @ibrahimcakir7390 3 ปีที่แล้ว +2

    Peki ustam iki depo var bir adet pompa( kuyu) iki depoya ayrı ayrı iki flatör ile nasıl kumanda edebiliriz yada kuyudaki motoru iki depodan birinin suyu bitince tekrar nasıl su takviye etmeli böyle bir sistem nasıl olur
    Paralel flatör ve toplu şamandıra düşündük flatör kapatmaz yada takılı kalır ise bu sefer motor sıkışır ve sıkıntı yapar Hidrofor yapalım dedim devamlı devreye gireceğinden biz vaz geçtik
    Yani kısacası iki depodan hangisi biterse motor çalışıp boş olanı doldursun istiyoruz

    •  3 ปีที่แล้ว

      Flatör ikinci bir flatör ile ikinci bir depoyu aynı pompa dan kontrol etmek biraz zor gibi. Düşündüm ama olmuyor galiba

    • @ibrahimcakir7390
      @ibrahimcakir7390 3 ปีที่แล้ว

      @ doğru ustam en iyisi depoları bir birine baypas yapıp aynı seviyeye alıp tek flötör ile çözmek sanırım

    • @ugurlu.teknolojikadam
      @ugurlu.teknolojikadam ปีที่แล้ว

      Büyük itimalle sorunu bir şekilde cözmüşünüzdür herhalde belki başkabirinin işine yarar diyelim yüksekteki deponun enüst seviyesi alttaki deponun üstseviyesinden bir iki metre yüksek dahafazlada olsa farketmez alttaki depoya toplu şamandıra takılıp üst depodan beslenir filatör üst depoya alt deponun üst seviyesinin altına düşmeyecek şekilde yerleştirilir üstdepodaki su alt deponun üstüne cıkınca allt depo dolmaya başlayacaktır doduğunda şamandıra kapanınca üst depo da tamamen dolunca filatör pompayı durduracaktır fılarör takılı kalırsa su üst deponun üstünden taşıp gidecektir.

  • @ibrahimaslan1231
    @ibrahimaslan1231 2 ปีที่แล้ว

    Motor yonu nasil değişir

  • @alperdalar
    @alperdalar 2 ปีที่แล้ว

    Merhaba, bugunun kosullarinda bu panoyu yapma maliyeti yaklasik olarak nedir?

    •  2 ปีที่แล้ว

      Şu an piyasa çok dalgalı ya. Malzeme fiyatı vermek imkansız gibi bişey

  • @yusufyuce06060
    @yusufyuce06060 3 ปีที่แล้ว

    Hocam videonuz ve emeğiniz için teşekkürler anlatımınız gayet iyi ama size bı sorum olacak konu dışı ama
    Sorum şu : 3 fazın olduğu yerde nötr oluşur bu olay nasıl gerçekleşiyor bilginiz varsa bir videoda onunla ilgili anlatır mısınız

    •  3 ปีที่แล้ว +1

      Nötür kopunca faz çakışması olur ama nötür oluşmasını duymadım. Bi bakıyım

    • @tankctopcusuvaricit-72mb21
      @tankctopcusuvaricit-72mb21 3 ปีที่แล้ว +2

      3 fazlı motor yıldız bağlı iken ve şebeke Trafosunun iç bobininde nötr oluşur çünkü manyetik alan oluşur. +manyetik alan nedir?
      Herhangi bir iletken'den akım geçerse bir manyetik alan meydana gelir.
      Jeneratör 3 faz çıkışı ile Şebeke Trafosunun iç bobininde Bir nötr oluşur manyetik alan sayesinde.

    • @yusufyuce06060
      @yusufyuce06060 3 ปีที่แล้ว +1

      @@tankctopcusuvaricit-72mb21 evet mantıklı...
      Fakat daha detaya daha derine inmem gerekiyor hep zaten kendime sormusumdur jeneratör nötr u nerden üretiyor diye

    • @tankctopcusuvaricit-72mb21
      @tankctopcusuvaricit-72mb21 3 ปีที่แล้ว +2

      @@yusufyuce06060 doğdu fikir yürütmüşsün, merak etmen güzel birşey gerçekten elektrik öğrencisimisin bilmiyorum ama değilsen öğrenmişsin gerçekten merakdan ne güzel. Evet jeneratörde'de yıldız noktası oluşur ve bu yıldız noktası Topraklanır, topraklama işlemine işletme Topraklaması denir aynı Elektrik direğinde bulunan Trafo gibi.

    • @yusufyuce06060
      @yusufyuce06060 3 ปีที่แล้ว

      @@tankctopcusuvaricit-72mb21 teşekkürler

  • @mehyasyakc538
    @mehyasyakc538 3 ปีที่แล้ว +3

    Usta sağolun da sırayla cihazların çalıştırma mantığını anlatarak bağlantıları yapsanız daha iyi olur. Bu anlatımdan kimse bir şey anlamaz bence. Bana tersten gidiyorsunuz gibi geliyor. Çok beliğ değil. Çünkü onun için taktığınız kabloyu çıkarıp tekrar bağlıyorsunuz. Yinede emeğinize sağlık. Yani örneğin nötrleri önce bir sırayla gitseniz bunun sayesinde flatör bağlantısı önce olacak, daha sonra flatörün kumanda ettiği ve sıvı seviyenin kumanda ettiği durumları ayrı bir anlatsanız.. VS Bilmiyorum bana çok karışık anlatım yapmışsınız gibi geldi.yinede tşk. Ler.

    •  3 ปีที่แล้ว +1

      Video çok uzar hepsinin çalışma prensibini detaylı anlatırsam.. Ama yinede öğretici yaptım.. Önce güç Devresi sonra sonra start stop butonu ile birlikte yardımcı röleler bağlanır.. Nötür evet ilk başta bağlanır ama nötürü flatör üzerinden geçirdiğim için sonunda yapmak zorunda kaldım

    • @mehyasyakc538
      @mehyasyakc538 3 ปีที่แล้ว +1

      @ Sağolun. Yüreğinize sağlık. Yalnız Termiği bu tarz bağlanmazsa düz atlama yaparak bağlansa olmazmı?Hep bu şekilde mi bağlanması gerekir.

    •  3 ปีที่แล้ว

      Atlama nasıl mesela

    • @mehyasyakc538
      @mehyasyakc538 3 ปีที่แล้ว +1

      @ termiğin üstünden kabloları 3 e gelip ordan (3.kontaktan) çıkış yapsak olmazmı.

    •  3 ปีที่แล้ว +1

      Termiğin üstündeki 95,96 NC kontak üzerinden start stop bağlantısı yaparak kumanda Devresi oluşturulur.. Ama Üç hangisi açıklarmısınız

  • @barsaltnbas9690
    @barsaltnbas9690 ปีที่แล้ว +1

    Slm malzeme listesi yazabilir misin rica etsem mümkünse

  • @muhittinaksoy9801
    @muhittinaksoy9801 3 ปีที่แล้ว +1

    Emeğinize sağlık. Bir sorum olacak. Sıvı seviye sensörlü panoya 2 adet start-stop nasıl eklenebilir? Teşekkürler...

    •  3 ปีที่แล้ว

      Farklı yerlerdeki noktalara mı

    •  3 ปีที่แล้ว

      th-cam.com/video/i-Lji7WJ9qk/w-d-xo.html

    • @muhittinaksoy9801
      @muhittinaksoy9801 3 ปีที่แล้ว +1

      @ Hocam bu videoda sıvı seviye sensörü yok. Dolayısıyla farklı yerlerdeki noktalara start-stop butonunu ekleyemedim.

    • @muhittinaksoy9801
      @muhittinaksoy9801 3 ปีที่แล้ว +1

      Yani benim kısaca sorunum şu: Elimde aç-kapat düğmesi olan (I-0) bir pano var. Ben buna start-stop butonları ekleyeceğim. 2 farklı yere eklediğim start-stop butonlarıyla dalgıç motoru açıp kapatacağım. Panomda sıvı seviye sensörü de mevcut.

    •  3 ปีที่แล้ว

      Mevcuddaki izlediğiniz dalgıç pompa Panosuna ek de attığım şekilde hem pako şalter hemde start stop butonu bağlayabilirsiniz

  • @orkundonmez9443
    @orkundonmez9443 3 ปีที่แล้ว +1

    Flatör yerine motor kulansak olurmu

    •  3 ปีที่แล้ว

      Flatör su tankını doldururken kontrol etmek için, kullanılıyor, suyun taşmasını önlemek için.. doğal olarak motor kullanamazsınız.

  • @bony_clyde
    @bony_clyde 3 ปีที่แล้ว +1

    Sayın abim bi konuya açıklık getirelim. Elektrotlar ve şamandıra aynı tanklarda mı ayrı tanklarda mı anlayamadım. Ayrıdır heralde çünkü aynı tankta olsa şamandırada elektrotlarda aynı işi yapıyor ??

    •  3 ปีที่แล้ว +1

      Sıvı Seviye rölesi kuyuya kullanılır, flatör yani sizin dediğiniz şamandıra havuz veya su tankına kullanılır, flatör kuyuya kullanılmaz..

    •  3 ปีที่แล้ว +1

      Motoru korumak için sıvı Seviye Kontrol Rölesi kullanılır, dolan tankın suyunun taşmasını önlemek için flatör kullanılır

    • @bony_clyde
      @bony_clyde 3 ปีที่แล้ว

      Evet teşekkür ederim bilgilendirdiğiniz için sondaj kuyusunda mı kullanılır pratikte kullanımıyla ilgili videonuz var mı?

    •  3 ปีที่แล้ว

      Kullanım amacınıza bağlı. Bir kaç video kanalda var bununla ilgili. Motor ve suya endeksli bir röle, sadece motoru susuzluktan korumak için kullanılır. Biliyorsunuz dalgıç pompa motoru içinde yağ var, su yağı soğutma görevi görüyor,, Motor susuz kalınca yağ soğutamaz ve bakır sargılar sıcaktan zarar görür

    • @sinandag4788
      @sinandag4788 2 ปีที่แล้ว +1

      Ustam bunun start stoplusunun devresini atabilir misin rica etsem

  • @halimyilmaz3527
    @halimyilmaz3527 2 ปีที่แล้ว

    Kardeşim o banyoya 1 mkş 2aşırı akım rolesi 3her iki kuyua mobil uygulama ile kontrol edilse acaba nasıl olur çok daha dedaisi daha çok var yorum yok ama. Sen yanlış bilgi veriyorsun

  • @muhammeddemir4709
    @muhammeddemir4709 2 ปีที่แล้ว +1

    Kardeşim sana birisi ışıklı kamara tutsun çekimlerin daha iyi olur

    •  2 ปีที่แล้ว

      🙂

  • @mustafayesilyaprak2332
    @mustafayesilyaprak2332 3 ปีที่แล้ว +1

    Kolay gelsin 7.5 hp motor 32 kademe pompa için kaçlık kablo kullanmak gerek 100 metreden su çekecek

    •  3 ปีที่แล้ว

      3 faz.. Yıldız Üçgen mi

    • @mustafayesilyaprak2332
      @mustafayesilyaprak2332 3 ปีที่แล้ว +1

      Evet

    •  3 ปีที่แล้ว

      4 mm Kablo uygundur

    • @mustafayesilyaprak2332
      @mustafayesilyaprak2332 3 ปีที่แล้ว +1

      60227 IEC 71 F 450/750 V HO7VVH6-F 364 mm2 Elimizde bu kablo var uygunmudur acaba üzerinde böyle yazıyor tam bilgim yok yardımcı olursanız ustam

    •  3 ปีที่แล้ว

      mm2 den önce tam olarak ne yazıyor

  • @kutbettinbay855
    @kutbettinbay855 2 ปีที่แล้ว +1

    Ustam bizim su dalgıç motoru suyu çekmiyor nedenleri ne olabilir .yanlız üç faz gidiyor motora

    •  2 ปีที่แล้ว +1

      Ya bu dalgıç pompalar çok sıkıntılı oluyor, sebebi de yerin altından biriken suyu çekmesi.. Motorun filtresi tıkanmış olabilir. Kuyunun içinde toprak kayması olmuş olabilir... Mümkün se Ulusu pompa kullan bunun filtresi güzel

    • @kutbettinbay855
      @kutbettinbay855 2 ปีที่แล้ว +1

      Teşekkür ederim kardeşim

    •  2 ปีที่แล้ว

      th-cam.com/users/shortsdaxUkZCWryA?feature=share
      Bu kanala abone olabilirmisiniz

  • @lutfisivri2066
    @lutfisivri2066 3 ปีที่แล้ว +1

    Merhaba! Benim dalgıç da aynı sistem fakat yenilerde kondansatör yandı 40 lık yeni taktım sorun olmadı şimdi de kontaktör açıyor ama çalışmıyor bazen çalışıyor , otomatik de sorun yok manuel açınca evdeki sigorta atıyor neden olabilir acaba

    •  3 ปีที่แล้ว

      Dalgıç kaç hp..

    • @lutfisivri2066
      @lutfisivri2066 3 ปีที่แล้ว +1

      1.5

    •  3 ปีที่แล้ว +1

      Sigorta kısa devreden atar.. Anladığım kadarı ile motorda problem yok, tesisatta problem var

    •  3 ปีที่แล้ว

      Elektrik kabloların sağlam mı.

    • @lutfisivri2066
      @lutfisivri2066 3 ปีที่แล้ว +1

      Sağlam

  • @ibrahimbyk5363
    @ibrahimbyk5363 2 ปีที่แล้ว

    Hocam yardımcı konnektör ucu klemens te boş kalıyor ya bu Enerjiyi nereden Alıyor

    •  2 ปีที่แล้ว +1

      Nötüre paralel bağlandığı için enerjiyi nötr üzerinden alıyor

    • @ibrahimbyk5363
      @ibrahimbyk5363 2 ปีที่แล้ว

      @ Teşekkür Ederim iyi çalışmalar

  • @umitsert3653
    @umitsert3653 3 ปีที่แล้ว

    Hocam 2.2 kwt trefoze su pompasını bu flatörle çalıştırmam lazım kuyu suyunu tahliye ediyorum acil yardım

    •  3 ปีที่แล้ว +1

      Flatörü kuyuya kullanmayacaksın demi.. Hepsini anlattım burda

    • @umitsert3653
      @umitsert3653 3 ปีที่แล้ว

      @ bina su toplama kuyusu hocam 2.5 m derinlik var

    • @umitsert3653
      @umitsert3653 3 ปีที่แล้ว

      @ 3 tane dalgıç yaktık bende trofeze motorla boşaltıyorum fakat şalteri aç kapa ile elimdeki dalgıçların şamsndırası ile bir panoya ihtiyacım var

    •  3 ปีที่แล้ว

      Anladım. Buradaki tamda sizin istediğiniz. Sadece kontaktör ün a1 faz bobin bacağına kahverengi kabloyu bağlayacaksınız

    •  3 ปีที่แล้ว

      Sıvı seviye rölesi de olur ama o biraz maliyetli 250₺ falan

  • @gokmengul8103
    @gokmengul8103 3 ปีที่แล้ว +1

    Allah aşkına sonuna doğru karman çorman ettiniz. Sakin anlatim yapın yoksa asla kimse bişey anlamaz. bu iş sahada böyle heyecanla olan bir şey değil ki. yine de teşekkürler

    •  3 ปีที่แล้ว +1

      Gayet sade anlatım dı. Teşekkürler

    • @muzafferfak1032
      @muzafferfak1032 6 หลายเดือนก่อน

      Evet sonlara doğru hiç ama hiç anlamadım,heyecandan olsa gerek çok karıştırdı.

  • @bukalemuntv5144
    @bukalemuntv5144 3 ปีที่แล้ว

    Dalgıç pompalar genelde monafaze mi oluyor?

    •  3 ปีที่แล้ว

      Trefaze de oluyor ama onların pek Bi detayı yok. Direk yol verip çalıştırıyon. Kırsal kesimlerde üç faz olmadığı için çoğunluk tek fazlı motorlar

    • @bukalemuntv5144
      @bukalemuntv5144 3 ปีที่แล้ว

      @ anladım peki yıldız üçgen yol verilmiyor özel durum mu var yoksa şebekedeki yük zaten az olduğu için mi direkt yol veriliyor

    •  3 ปีที่แล้ว

      Yıldız üçgen yol verilenlerde var. Çok büyük pomlalarda yıldız üçgen çalışıyor. Yani 6 hp nin üstü mü ne yıldız üçgen.

  • @mehmetzonturlu8388
    @mehmetzonturlu8388 3 ปีที่แล้ว +1

    Tek fazli sessiz kontoktorle yaparsan daha anlamli olur diye dusunuyorum kardes

    •  3 ปีที่แล้ว

      Sessiz kontaktör dalgıç için çok kibar ya

    •  3 ปีที่แล้ว

      Ama olabilir

    • @mehmetzonturlu8388
      @mehmetzonturlu8388 3 ปีที่แล้ว +1

      Tek fazli daha anlatila bilir oyuzden kardes

    •  3 ปีที่แล้ว

      Evet ama onları konutlarda kullanıyorlar, Motor kontrolünde pek kullanmıyor lar

  • @isabayraktar3211
    @isabayraktar3211 3 ปีที่แล้ว +1

    Bu devreye start stop butonları ile beraber dtr 10 entes zaman saatini nasıl bağlayabilirim?

    •  3 ปีที่แล้ว

      Mümkün değil.. Zaman saatini sadece pako şalter ile bağlayabilirsin

    •  3 ปีที่แล้ว

      th-cam.com/video/f92QUic0w1g/w-d-xo.html

    • @isabayraktar3211
      @isabayraktar3211 3 ปีที่แล้ว +1

      @ Termiği iptal mi edeceğim?

    •  3 ปีที่แล้ว

      Hayır ben sisteme termik bağlamadım ama termik olacak

    • @isabayraktar3211
      @isabayraktar3211 3 ปีที่แล้ว +1

      Termik üzerinden nasıl bağlayabilirim. Yardımcı olabilir misiniz?

  • @ercanbayram8938
    @ercanbayram8938 3 ปีที่แล้ว

    Elektrotların hangisi üst alt taban olduğunu ölçü aletiyle nasıl anlariz

    •  3 ปีที่แล้ว +1

      Kardeş ölçü aletini napcan.. Rölenin üzerinde yazıyor.. Hangi elektrodu U terminaline bağlasan orası üst seviye elektrodu oluyor

    • @ercanbayram8938
      @ercanbayram8938 3 ปีที่แล้ว

      @ anladım da elektrodlar kuyuda görme şansım yok sokulmuş uçları anlYBilirmiyiz

    •  3 ปีที่แล้ว +1

      Kablo mesafesinden anlarsınız.. En uzun kablo taban elektrodu,, iki metre kısa olan alt seviye elektrodu,, birazdaha kısa olan üst seviye elektrodu.. Bu şekilde düşünebilirsiniz

    • @ercanbayram8938
      @ercanbayram8938 3 ปีที่แล้ว +1

      @ Sağol ustam hayırlı geceler

    •  3 ปีที่แล้ว

      Eyvallah

  •  2 ปีที่แล้ว

    Faz Nötr Topraklama Monofaze bu

  •  2 ปีที่แล้ว +1

    Yardımcı faz ne abi? :D

    •  2 ปีที่แล้ว +1

      Motorun yol alması için kondansatör ile oluşturulan gerilim

  • @UK211
    @UK211 2 ปีที่แล้ว

    kanalizasyon kuyusu varsa tabki boşaltmak istersiniz ,

  • @mavi3180
    @mavi3180 3 ปีที่แล้ว +1

    Wp grubunuz var mı

    •  3 ปีที่แล้ว +1

      facebook.com/bilge.oglan.3

  • @sezginkahraman1467
    @sezginkahraman1467 3 ปีที่แล้ว +1

    Şamandıra için link atar mısın

    •  3 ปีที่แล้ว

      Şamandıra dan kastınız he acaba
      th-cam.com/video/AYGixtqyl3E/w-d-xo.html

  • @rustemkaraman6119
    @rustemkaraman6119 2 ปีที่แล้ว +1

    Bilmiyoruz hocam

    •  2 ปีที่แล้ว

      🤔?

  • @mehmetduman8509
    @mehmetduman8509 3 ปีที่แล้ว +1

    konzaktor link verebilirmisin ben nette bulamadım

    •  3 ปีที่แล้ว +1

      Hangi marka

    • @mehmetduman8509
      @mehmetduman8509 3 ปีที่แล้ว

      @ marka fark etmez yuvarlak düz akım veren

    •  3 ปีที่แล้ว +1

      www.hepsiburada.com/siemens-kontaktor-3tf40-10-4kw-230vac-pm-HB0000018YH4

    • @mehmetduman8509
      @mehmetduman8509 3 ปีที่แล้ว +1

      @ abim kontaktör değil yuvallak kontaktör e bağlandığın aparat diyorum onun link verirmisin

    • @mehmetduman8509
      @mehmetduman8509 3 ปีที่แล้ว

      @ yuvallak gri 2 kablosu beyaz olan parça diyorum

  • @esatsenal1788
    @esatsenal1788 3 ปีที่แล้ว +1

    Motorun akımını kontaktör üstünden eşit pay yapmiyosun

    •  3 ปีที่แล้ว

      Kontaktörün güç Devresi amper kapasitesi yeterli olduktan sonra faz nötürü korumaya almanın zararı olmaz diye düşünüyorum.. Ama faz seri de bağlana bilir kontaktörün güç Devresi ne

  • @ismailakkus4789
    @ismailakkus4789 หลายเดือนก่อน +1

    Hiçbiri nin şeması vermemişsin, bu da anlatımı çok soyut yapıyor. Şemayı biz mi çizelim istiyorsun ?