Cold Room ki full Control wiring||Full wiring of walk in chiller and freezer||Cold Storage Diagram
ฝัง
- เผยแพร่เมื่อ 7 ก.พ. 2025
- Cold Room ki full control wiring
Full wiring of walk in chiller and freezer
#coldroom
#coldroomdiagarm
#wiringcoldstore
cold room wiring live :- • Cold room wiring Conne...
NO NC kaise kaam karta hai full video:- • Contactor NO and NC pa...
cold room wiring Connection
cold room diagram
cold room wiring diagram
full wiring of walk in chiller
full wiring of cold room
cold room wiring
walk in chiller connection
cold store wiring
cold store wiring diagram
cold store connection
kaise karte hain cold room ke panel ki wiring for more information please watch this video till the end.
Friends aaj ki video cold room wiring ki full information par hai video puri dekhiyega Restaurants ki machine ka kaam sikhne ke liye hamare channel ko Subscribe kijiye jis se Aap Equipment and Refrigeration ki video dekh sake aur aap Hamare channel ke madham se help le sake aur india and out of india kisi bhi Country mai ek Achhi job kr sake
Please like ,Subscribe and share
Thank you for your love and watching videos
For any inquiry or question :- E-mail
knowledgeofequipment@gmail.com
For any Help Contact +241 06 87 65 21
good job rashid bhai Allah salamat rakhe apko ❤️
Shukriya Sajid ❤️❤️
Wiring is no right temp anai pr s valve off hojai ga or comp on rhai ga
Bro comp lp se of hoga ye wiring krny k 3 tariqy hn
Saudi me Cold room ka kaam krne aaye huye logon ka welcome 🤗
Hahaha 👍👍👍
Bhi bahut sundar samza dya hai bro 👏👍🏻
❤veary good
buhat shukrya brother love you from Pakistan
Thank you
Bahut achi video h. Ky aap without timer sirf subzero controller display per video banaye. Sub zero system se chalega. Please. Hum aap k video ka intezaar m hain
Ok soon
Semi hermetic compressor ke sath penal par video me only all control bata dijiyega
Very nice video thanks 🙏
Ok noted i will try
Good make vedio out door control semi hermetic
Part 2 please jaldi banao
Already upload ho chuki hai th-cam.com/video/aN4ibfOR3ho/w-d-xo.html
Mashullah A one bro
Very good engineering knowledge, ❤ but I want to need control diagram make by autocad, so that all technical personals can get and understand complete logic.
Okay I'll try
Hii brother ,can you make one video for semi harmetic compressor protection mudule wiring
Ap ne copressor ki comand timer se di he jo k sub ziro k compressor vale point se niklni thie
Aap ki baat theek hai
Ye video bhi dekh lo th-cam.com/video/x6STZ5UnT1A/w-d-xo.html
bahi sahab wirring may galti ka ap nay temperature ka control ki supply nahi di or ager timer ha to digital meter ki zarorat nahi
Rashid bahi ssps ka bara me explane kary
Ok
Masha Allah ❤
Zabrdast ❤
I need it
Good explanation 🎉
Thank you
Is me aik porblm he door heater or Derain heater darik kr deya sytm off b kr do tu dono kam krty rahy gay
Direct nahi karna chahiye
Masha allah der kha dosta
Shukriya ji Tariq Bhai
Sir sub zero temperatures controller nikal ke canetion solenoid valve me deya compressor me nahi jaye ga
On delay timer se compressor se jaye ga
Part 2 bna rha hu aap samjh jaynge
Bhai thermostat ki wire kider se use krni or thermostat sensor ki
Playlists mai Digital thermostat wiring ki video hai dekh lo
Your videos are very helpful ❤
Thanks
Good
Module really kaha hai or evaporator fan ka connection dobara check karo Sahi hai?
Agar ap Module Relay ko use Krna chate ho toh lga skte ho.,
Evaporator fan ke connection contactor par jayenge Jo hamara contactor NO NC bala hoga
Ayse to temperature ane pr sirf s.v valve bnd ho ga compressor to chalta rahyn ga bbahi ye clear kryn
Jab SV valve bnd hoga tab LP se compressor bnd ho jyga
Eske up bhi meri video hai SV valve ka kya kaam hai
Cold room wiring ki part 2 video aane bali hai usme aur clear kar dunga
Machine pump down hoke lp se
band ho jayegi
Great 👍 job
Very good video
Thanks
Try to exercise ladder diagram my friend
Boss is main oil pressure switch nhi lagaya or high pressure switch nhi gaya
Oil pressure Kahan lagta hai cold room Mai and LP HP pressure switch ki wiring batai hai video puri dekhe
super
Door heater hamesha ON rehta hai?
Ji Han
Is video ko aap accha se khud se dekho aap ne wiring diagram sahi se nahi banaya hai sab zero ka wiring kaise ho ga aap ne bataya nahi ek bhi na sensor hai na thermostat hai compressor ko aap lp switch se on karva rahe phir sab zero ka kya kaam hai ek video sir detail m banao k har ek part k kaam ko dikhao
@@mdmurtuja9879 playlists check kro subzero se Cold room control wiring ki hai , part 2 video
@@knowledgeofequipmentpart 2 link share kijiye sir
th-cam.com/video/aN4ibfOR3ho/w-d-xo.html
very nice ❤
Good explanation 👏 ❤
❤
Solenoid valve ko separate kyon kar diya wo bhi to series me hota
bhai aapane no ko current nahin diya NC se nikala hai
Hi bro bahut ache se explain kiya 1 or video banaiye sab sub zero (controller display) par please?
Kiya aap ka no. Milsaktahe
Han ji bataye ..?
Sir -20 tampture main R404 R22 gass hai gass ka passour kya rhe ga section pe
Ye video dekh lijiyega full information hai th-cam.com/video/axpw6cM40yY/w-d-xo.html
20-25
Heater ka kya kaam h cold storage mein
Without heart Deforst nhi hoga and 3,4 din chlne ke baad temperature bhi nahi aayega
Grat sir
Good job Sir
Good 🎉
Sir I am thankful to u
Welcome
Thanks
bahi sahab jab compresser on hoga to fan kon on karay ga bahi ko supply ap nay compresser on ki tab hi fan on ho ga galat giad mat karo
Bhaisaab Apne Esme dekha ki contactor NO NC bale Lage huye hain apko pta hoga ki NO NC kaise kaam karta hai
Everything okay but how you ON the Compressor Contractor ?
By Dixell or subzero
Thanks bro
Thanks very useful
Sensor ke bareme nahi bataye bhai
Dixell Control Mai lagega Sensor
Mere ko eak friz dekha digiyana
Kya ..?
🥰🥰🥰🥰🥰🥰🥰
Temperature pura hona ka bad compressor off kasa ho ga
By Solenoid Valve
Bhai dixell ka thermostat hai infrico freedge hai cooling coil par ice aa raha hai aur alarm HA aa raha hai New freedge hai pahale sahi tha kya kare.
Freezer hai kya ..?
Chiller hai
Temperature down nahi aa raha hai ice hai shayad setting mai problem ho defrost Nahi ho raha hai automatic.
Han agar Deforst nahi hoga toh ice aayegi
Bhai koi idea
Bhai. Thermostat ka conection. Kaha hei
Solenoid valve par
solinide valve ki wiring me lapda dikthahe
Nice
sub zero ka kam sirf solonoied ko control kiya apne
Jab SV band hota hai phir kuch second mai Compressor LP se cut off ho jata hai
Compressor ka overload switch ka nhi btaya
Sir,You are Given Line ,I Think Wrong, BecauseYou Have To Give Line Sub Zeero To Timer Line ,You Given Line Main Tugal Switch. Maybe Wrong. Pls Chak .
جناب ایووپریٹر اور ہیٹر کے کنٹیکٹر کے این سی اور این او کو آپس میں شارٹ کیا۔ یہ سمجھ نہیں آیا
Aap ye video dekh lijiye NO NC ki
th-cam.com/video/pHLDkaWbqBU/w-d-xo.html
No nc ka bolna chye kia ha or na video bnai bd main
Bhai Apne dekhi nhi already upload kar di hai th-cam.com/video/pHLDkaWbqBU/w-d-xo.html
Where is the power of A2 evaporatior that connect on to normally close of heater contactor
Evaporator fan is working with the NO NC contactor
@@knowledgeofequipment What I'm asking is the A2 line of your evaporator that is connected to the normally closed of your heater contactor, why don't you make a ladder diagram to make it clearer
सर,..जब डि-फ्रोसटींग हिटर द्वारा हो रही हैं,...तो सॉलिनॉइड वाल्व का क्या काम हैं। इसके बारे में भी बता दिजीए।
Aap playlist check karke already es par bhi video upload kar di hai
th-cam.com/video/419WoOpJOIc/w-d-xo.htmlsi=aecFfY7Uba4jXLUW
Thermostat bhi nahi hai
Digital temperature thermostat lga hua hai
Sir sab o kiha
No nc ka btya ni jo zrori hota
th-cam.com/video/pHLDkaWbqBU/w-d-xo.html
Wrong diagram pahle bhi compressor
Aur timer se bhi compressor pahle write karna sikho phir logo ko batawo biryani banate banate khichdi bna diya bhae
Biemetl switch kidhar hai
Bhai connection galat h aapka temperature control nahin hoga
Bhai btaye Kahan galat hai aur kaise temperature control nahi hoga
Temperature control Se output kahan aaraha h
@@haseenengineering9008 Bhai AP pehle aur videos hain unko dekho phir smjh jaoge,,Ye AC ya fridge nahi hai jo thermostat ka wire direct compressor ke contactor par jayega ..
Cold storage mai thermostat ka wire SV par jata hai aur jab SV band hota hai toh compressor ko low pressure switch cut off krta hai
For me
What..?
Sir perfect waring nhi hai mind nhi krna
Cold room ek jese nhi hote sab
Sab ki kuch na kuch wiring alag Hoti hai
Ladder diagram please not pictorial
Ok
@@knowledgeofequipmenti am waiting for your diagram my teacher
Comprassor 😂😂😂
😂
wiring galt ahi bhai
Han So sakti hai galat wiring
But Bhai Kahan galat hai ye bhi bta do
Please Dada apka phone no dowge
Ji bataye ..?
sir aapka WhatsApp number dijiye.😢
Koi bhi problem ho toh email ya comments kar sakte hain
Thanks