Megger test of transformer ll IR valu test of transformer ll 3 Phase
ฝัง
- เผยแพร่เมื่อ 29 ส.ค. 2024
- Megger test of transformer ll IR valu test of transformer ll 3 Phase #SurokshElectricalServices
#transformer #megger #irtest #electrical #electricalpower #threephasetransformer #11kv #सुरोक्ष_इलेट्रिकल_सर्विसेज
🚀 विद्युत संबंधित वीडियो देखने के लिए #सुरोक्ष_इलेट्रिकल_सर्विसेज चैनल को सब्सक्राइब करे 👇 / surokshelectricalservices
عقلمند کے لیے اشارہ ہی کافی ہوتا ہے
آپ نے HT to earth کا پریکٹیکل کرکے دکھایا ہے بقیہ کسی وجہ سے نہیں دکھا پائے تو کوئی بات نہیں سب سمجھ آ گیا ہے بہت شکریہ
Ap bolne k trika bahut accha h dost bolte ho mujhe bahut accha lga
Thanks Dear ☺
Ekdom onjob training Ka perfect example & practical experience also.
Goog
Dost vedi bhut achi thi
Mega Ohm must be recorded in Uppercase Letters "M", and not "m".
Thank you sir to do show practical
Thank you for your patience in showing this in live and the way you pronounce dosth sounds really thank you sir
SUPER sir ji
video man is sick
👌👍nice information real prectical 🙏
Meggar se Bhut help hae 👍️
Nice video brother mai bhi electrical ka work krta hu dost 🥰🥰🥰❤❤👍👍👍👍👍👌👌👌👌👌
👍
Great
Good
Very nice sir
thik hai dost thanku
🙂
Bhai Ask your Company to change Megger probe shouldn't be hold with hand Need Clip type Also Megger looks local company,
Same thing I have noticed and it is dangerous during test that holding probs by hand.
Nice sir for helping me
Nice work Sir
Tq sirji
🙏🙏👍👍👍👍
Super
Video is good,but u not explain full about condition and many more thing...
Thank you dost
🚀 विद्युत संबंधित वीडियो देखने के लिए #सुरोक्ष_इलेट्रिकल_सर्विसेज चैनल को सब्सक्राइब करे 👇 th-cam.com/users/SurokshElectricalServices
Thank u sir
IR test ke liye ye IR test kit sahi nehin hai..Accident hone ki chances jyada hai..
Theek h dost😂😂
11kv hand gloves 🧤 used brother for sefty
Good video but HT-LT-E write and speak not similarly
For HT to earth test
Did you short all phases of HT? And one lead connected to ground
Are Bhai sahab IR testing machine me second khud hi count hota hai
Kyoritso company ka achha hota hai
Fully confused plz clear my doubt ...transformer HT side kitna KV ka tha ... Aur aap 2500 mein kyu meger ko set kiye.....aur agar G ohms aata hai toh kya hoga ....
Me also thora confuse hei
Sir CT neutral pe nhi hoti kya??? कहीं कहीं to dekhi h मैंने.... Please tell
Very nice information sir 👍
Dost 😀
Sir to do u know that in HT side 2500 set kare
We are looking for power transformers used in running condition
Meggar karte samay near by kitna value honi chahiye mega ohms mai aur kitna kam hone se prblm hosakta hain
1Mohm for 1kv
Bhai Humne kal ek transformer ka magger kiya aur uski value hamisha incerese hori thi kabhi bhi constant nhi thi aisa kyu hua please answer do
Aur BHI videos upload karo sir plz
What is the use of third point..... Used only...two points
Can connect to LT when doing HT-Earth or HT when doing LT-Earth. In theory, it gives more accurate results. It's called a guard terminal to isolate the effect of other winding.
Sar apne ware me video bnaia ki aap kis chij me kaam ker te ho or ham sabhi bhai log kise aap jise kam ker sakte he
Transformer ke Nutan se magar kaise karte Hain
Do you work in Military Engineer Service?
Me thora sa confuse hei sir can you help me
HT-LT ka to shi se batana tha sir ji
Tf ka IR valu kitna Mohm hona chahia uska range kitna hota hai
Kitne rating transformer p perform kiya h ye test??
Full description do sir
60s and 10minute me karte hain na
Vai ye baht danger
Aap adhura maat dekhaiye please sab dekhana padega ok
सर ट्रांफोर्मर में से जो आउट पुट 3फेज जो आया है उस मे वोट सेम आता है
Megger kitne omh hai
Hello dear
Is magger ka prise kitna hai
Meggar rating Kiya hai
Bhai ham new meggar bnata h
Discharge rod kahan hai sir bina discharge kiye kam nahi karna chahiye
English please
Kitni value aani chaiye minimum or maximum ??
Inhone bataya ke 1m ohm se kam nahi ani chahiye
Pura to batate
Bushings ko short kyu karte hai
Reading lete hue transformer p connection nae Dikhae apny
Guard wire is missing
Sir,
Pura video to ache se banate..
Pura practical kar k diko
Why 500 or why 2500 and these are dc ?
Transformer Purana ho gaya h
Transformers kitne kV ka hai
400kva
Hlo
Safety first boos no ✋ gloves
LT AUR E ME RED LEAD OF TESTER KISME LAGAYENGE
LT me lagayenge
Bhai g ht ko 2500 p nhi 5000 p krte hai
Hello sir aap apna no de sakte hai main uppcl main tg2 hu apki madad se mujhe bahut kuch sikhne ko milega
itna dost dost kio bolte reheteho bhiya
😀
20 mva ka kasa magar karaga
Sir Kitnay KV ka T/F hai?
400kva
Hmlogo job hai kya
Pura test tu dikhaya nhi
Incomplete video hai
Bhai adhura Gyan ghatak hota dost Kisi ko video adhura video mat Di khao
Bhsiya apna number dijiye
पूरा तो बताया नहीं गुरदेव की कितनी होम सही है विडियो बनाने के चक्कर मेअधूरी जानकारी
Bhag
Barbar jamta nahi to mat banavo video kya faltu video banaya