ความคิดเห็น •

  • @mildredmamarilsisonvlogs2514
    @mildredmamarilsisonvlogs2514 ปีที่แล้ว +1

    Wow bait nyo po sana lhat katulad nyo may malasakit sa customer Godbless you more

  • @herablesstv9738
    @herablesstv9738 3 ปีที่แล้ว +1

    OK YANG TUTORIAL MO KA MASTER LHON. MAKAKATULONG KA SA MGA BAGUHANG TECQNICIAN NA GUSTONG MATUTO...HONEST AT MABUTI KANG TAO... KEEP IT UP👍😉😊👌... GOD BLESS U ALWAYS😇...

  • @dollyvitorpinon5211
    @dollyvitorpinon5211 3 ปีที่แล้ว +1

    Hello po ka master lhon .hindi ako mgsasawa panuorin ka ... God bless you more

  • @corneliopabes925
    @corneliopabes925 3 ปีที่แล้ว +2

    Napasubscribe tuloy ako sayo master,,, ito kc dapat,, walang naiiwang tanong na di sinasagut,, ayus na ayus ang channel mo tsaka fully loaded knowledge,,, salamat sa pagshare

  • @chrisvalida330
    @chrisvalida330 3 ปีที่แล้ว +3

    Nice 1 ka master, nakatulong kana nman sa iba nating kababayan.. Huwag ka sana mag sawa mag turo ka master.. Godbless sir 🙏

  • @paulkennedytagpis7479
    @paulkennedytagpis7479 3 ปีที่แล้ว +2

    Astig mo talaga kamaster , dapat may kasama kapag nagseservice ka

  • @fideliipiston4392
    @fideliipiston4392 3 ปีที่แล้ว +1

    Ang husay mo master Lhon sa trouble shoot nakuha mo agad ang main problem ng ref ng client mo....galing mo master Lhon..god bless po at ingat ka lagi sa biyahe mo..salamat po master Lhon...

  • @raynaldovelasco9372
    @raynaldovelasco9372 2 ปีที่แล้ว +4

    Sir dapat pinaandar mo wala load para malaman. Kasi baka may problema lng ung filter drier. Kaya mataas amg curtent nya ay nag kakat off.. minsan ganuan lasi amg problema.

  • @jaysiapno659
    @jaysiapno659 3 ปีที่แล้ว +1

    Ser lhon good PM...masaya na naman ako kase my video ka nanaman... para sakin dagdag kaalaman ul8... ser lhon Eton naman ung problema ko... ung ref namin na non inverter... Panasonic sya... ginawa ko ung natutunan ko sa yu... kase ang problema nito..kaunti lng ang lamig nya sa evap.coil...kaya ang ginawa ko ni reprocess ko...nag flushing ako using r141b...tas ni leaktest ko tas change filterdrier...tas nag vacuum at leaktest at nigative pressure...wala naman ako nakitang leak...tas ni refill ko 134a incan binli ko sa shopee160p..nag initial charging for 20...psi...tas pinagana ko nag return dahan dahan ung pointer ng lowside gauge ko tas ni refill ko very slow ...habana umaandar ung compressor. Peru ung pointer ng gauge ko nasa negative parin.. nilagyan ko ulit ng refrigerant...naubos na ung incan 134a... negative parin ung reading ko sa loside....ung name plate s 105grams lng ung bumili ko 300grams na refrigerant... na halos anubis na NASA negative pressure parin...ser lhon pasensya kana kahaba kwento ko... ser lhon dnaman ako nagmamadali.. pag my time ka bigyan mo ako ng tips..sana mabigyan mo ako ng advice...ser lhon tynx...

    • @kamastertvlhonsantelices
      @kamastertvlhonsantelices 3 ปีที่แล้ว

      Ok...nagba vacuum sia sir..
      Madali lng yan.check.mo.ung pinaghinangan mo..lalong lalo na aa filter drier..mukhang barado ang daanan ng refrigerant...nakunan.mo ba ng monitoring ung liquid line.mo...para dun.mo.rin.makikita na
      Barado ang system.mo..maarin bumara ung silver rod sa tube habang naghihinang ka.

  • @mariolegaspi681
    @mariolegaspi681 3 ปีที่แล้ว +2

    Paano yan noy pag pinalitan yung COMPRESSOR mga magkano aabutin gastos nyan. Natanong ko para pag nagpagawa ako sa iyo may idea na ako. Salamat noy!
    Syanga pala pag pinalitan mo compressor nyan sana ma i blog mo uli para makita namin. GOD BLESS NOY!!!

  • @ogielavarro1094
    @ogielavarro1094 3 ปีที่แล้ว +1

    yuun ooh, mabuhay ang mga oragon💪💪💪💪💪💪

  • @herablesstv9738
    @herablesstv9738 3 ปีที่แล้ว

    OK N OK PO YAN KAMASTER...GALING PO NINYO MAG REPAIR. 😉

  • @vicentedugmocjr760
    @vicentedugmocjr760 2 ปีที่แล้ว +1

    Thank you sir galing mo master..

  • @dungskieph3812
    @dungskieph3812 3 ปีที่แล้ว +3

    Ayus master...matagaltagal din hindi ako nakakapanood...hahabo to master..hehhehe ganyan nangyari sa akin master.. bagong compressor hindi ko na check pag bili ang ampherahe.. pag kabit ko dali ako.. high amphere...

    • @kamastertvlhonsantelices
      @kamastertvlhonsantelices 3 ปีที่แล้ว

      😁😁 Good ung resistance windings niya sir..pero stock up siya mechanicaly kaya magbi build up talaga ng current.

    • @dungskieph3812
      @dungskieph3812 3 ปีที่แล้ว +1

      Nalugi tuloy ako... Abunado...

    • @kamastertvlhonsantelices
      @kamastertvlhonsantelices 3 ปีที่แล้ว +1

      Ok lng yan sir..basta in Goodfaith tau asahan mo na darating ang blesings ng panginoon.

    • @dungskieph3812
      @dungskieph3812 3 ปีที่แล้ว +2

      @@kamastertvlhonsantelices ou master part ng trabaho natin yan eh.. d sa lahat ng oras kikita... Paminsan minsan sacrifice nman hehehe... Ang importanti maganda output,.. para maerocomenda sa iba... Magandang gabi sa inyo master, salamat.. keep safe...

    • @kamastertvlhonsantelices
      @kamastertvlhonsantelices 3 ปีที่แล้ว +1

      Yowwwnnn....da best ka sir👍👍👍

  • @oseng0010
    @oseng0010 ปีที่แล้ว

    Another lesson na naman natutunan ko master lhon👌🏼 pano kaya master kung pitik lang ng pitim si relay? Tuwing aandar si compressor pipitik lang si relay at hindi na umaandar si compessor... ano possible sira? High ampere din kaya?

    • @kamastertvlhonsantelices
      @kamastertvlhonsantelices ปีที่แล้ว +1

      Compressor windings,
      Compressor mechanical
      OLP,thermostat muna dapat ang icheck sir

    • @oseng0010
      @oseng0010 ปีที่แล้ว

      @@kamastertvlhonsantelices salamat ka master... may binebenta din kasi saking ref. Wala pa akong clamp meter... declared ng unang tech. Na tumingin refrigerant daw problema. . alam na mas malaki singilan kapag refrigerant problema...

  • @grimreaper7256
    @grimreaper7256 2 ปีที่แล้ว

    Nice master dami ku namn matutunan

  • @jicivel
    @jicivel ปีที่แล้ว +1

    Sana po nandito po kayo sa cavite para mapatingnan KO din Yung refrigerator ko

  • @sanitoedninodurano6981
    @sanitoedninodurano6981 2 ปีที่แล้ว +1

    Galing mo talaga idol
    New sub po from leyte
    Pa sht out nmn..

  • @panchoelliot7375
    @panchoelliot7375 2 ปีที่แล้ว +2

    What if ang pinalit na relay ay mas mababa o mas mataas ang ohms? di ba masisira yung compressor?

  • @permanentveneracion9094
    @permanentveneracion9094 ปีที่แล้ว

    Gud day boss! watching ur video,, ask ko lang ung ref ko parang ganyan din problema,, gud naman overload at relay,, ano kaya possible sira sir? tnx in advance....

  • @marielmalate4361
    @marielmalate4361 24 วันที่ผ่านมา

    ka master, my tanung lng aq.. ung aircon q kz continues ung running ng compressor. d nag sstop kht malamig na. pero nung nag check aq ng thermostat tinapat q sa hangin working nmn cya.. d nmn madumi aircon q. ung olp b pasibol n sira? n dapat pg mainit n ung compresor m mag oopen contact n dapat un tama po b?

  • @EduardoCabal-j1v
    @EduardoCabal-j1v 9 หลายเดือนก่อน +1

    Ka master halos ganyan Ang problema Ng ice maker na inaayos ko ,,mataas din Ang starting current na nasu2kat ko,, Ang max current Ng compressor requirements 11 amps. Nasu2kat ko nasa 10 amps umaandar naman Ang compressor at nag yeyelo after 45 mins. nag ooverload Ng 35 amps. at nag titrip Ang breaker,,Ang overload requirements Ng compressor 40 amps,, after pahingahin ko Ang compressor andar nnman sya sa parehong sitwasyon trip nnman Ang breaker 😭😭😭na check ko na Ang relay,,olp,,running at starting capacitors ok naman lahat,,,ok naman Ang pag yeyelo after 45 mins nga lang Trip ulit Ang breaker 🤔🤔🤔Wala na Ako idea ka master,,,sau na ka master Ang aking saklolo😢para sayong kaalaman ka master electronics technician Ako d2 sa taif ksa sa Royal palace inaaral ko itong refregiration KC walang marunong sa refrigeration d2,,,3 na naayos Kong cooling machine 2 freezer at 1 ice maker machine sa tulong Ng tutorial vlog mo 👌👍many thanks ka master God bless Bismillah 🙏🙏🙏

  • @jannosvlogspot
    @jannosvlogspot 3 ปีที่แล้ว +2

    Dagdag kaalaman ulit..salamat

  • @VicenteTugano
    @VicenteTugano หลายเดือนก่อน +1

    Sir master pwede po mag pa home service repair ng refrigerator sanyo po ung brand old model maraming salamat po

  • @studentcarabbacanh8793
    @studentcarabbacanh8793 3 ปีที่แล้ว +2

    Magandang araw Ka master, newbi...
    Pa tingin naman po Yung mga gamit mo pag nag ho home service ka...
    1st time ko maka panood ng vid. Mo at Ang linaw ng pag Kaka explain, Sana po marami kapang matulungan dilang sa mga naayos mo kundi sa Amin ding student..
    Salamat kamaster

    • @kamastertvlhonsantelices
      @kamastertvlhonsantelices 3 ปีที่แล้ว

      Sundan nio lng mga video ko...sisnisigurado ko sa inyo na may matututunan kau na hindi naituro sa school na makikita nio sa mga video ko.

  • @celabril1380
    @celabril1380 2 ปีที่แล้ว +1

    napa subscribe tuloy aq

  • @markanthonyfranco3972
    @markanthonyfranco3972 ปีที่แล้ว +1

    Nice master idol..
    Master pasaklolo naman po baka makahingi po ako ng advise nag diy lang po ako sa bahay halos lahat ng video nyo napanood ko na po at napakadami ko ng natutunan.. ung carrier window type 1.5hp ko. Umaandar po sya at lumalamig pero after 5-10sec namamatay ang compressor at nag high ampere.. halos umaabot ng 21ampere.. ano po kaya master problema.. salamat po Ka master.

  • @RomeoErasmo
    @RomeoErasmo 2 หลายเดือนก่อน

    Ka master paano magkabit ng automatic to manual kung walang capacitor pero may clutch lang ang ginamit? 3 wires yon clutch niya pero dalawang wire naman ang may resistance ,LG automatic washing machine ,salamat sa sagot master

  • @ronelsalvoro1269
    @ronelsalvoro1269 3 ปีที่แล้ว +2

    Boss bawasan mu lang nang pa unti2 ang freon. Ganyan na ganyan ang nang yari sa ginawa ko na ref.

  • @jhonnabellebustillo1807
    @jhonnabellebustillo1807 2 ปีที่แล้ว

    sir naghohome serbis po ba kau?? sampaloc manila lang po..thanks

  • @melcamba4457
    @melcamba4457 9 หลายเดือนก่อน

    Ka master ganyan din ba ang e check kapag inverter ref parehas lng

  • @benjiearroyo6881
    @benjiearroyo6881 ปีที่แล้ว +1

    👍👍👍

  • @djjomcrumer9628
    @djjomcrumer9628 ปีที่แล้ว +1

    Tanong lng po ok lng po bang palitan ang relay kasi may alog na po sya kaso wla po akong tester na katulad sa inyo Salamat po.. 🙏

  • @ElmiMaddawin
    @ElmiMaddawin 2 หลายเดือนก่อน +1

    Sir tanong k lng po sna my freezer upright panasonic po kmi mg 6mos.plng po bgla po ngshotdown.ngmoist sa gilid sa my pinto po.sbi ng kinuhanan po nmim is bunutin at isaksak after 10mnts nging ok nman po after in a day gnun n nman po ulit normal po ba un s freezer?wla po b problema un

    • @kamastertvlhonsantelices
      @kamastertvlhonsantelices 2 หลายเดือนก่อน

      inverter po ba yab

    • @ElmiMaddawin
      @ElmiMaddawin 2 หลายเดือนก่อน

      @@kamastertvlhonsantelices opo sir inverter po xa panasonic upright po.nung friday ng umaga ung unang shotdown nya po tpos ngaung umaga n nman po pero after 10,15mnts.sinaksak po ulit umandar nman n po.ngwwory kc ako kc mg 5mos.plng po ngaung august 4.ano po posibleng dhilan nya po pg gnun.my chestype po kmi pero never po nmin naencounter ung gnung shotdown bigla.

  • @systemunderground
    @systemunderground 2 ปีที่แล้ว +1

    Ano po ba dapat ang range ng starting current?

  • @limeoirasecen9502
    @limeoirasecen9502 2 ปีที่แล้ว +2

    Ka master tv....salamat po sa iyo...may itatanong lang po ako....kailangan po ba match yong compressor at over load relay.....salamat po sa sagot.....

    • @kamastertvlhonsantelices
      @kamastertvlhonsantelices 2 ปีที่แล้ว +1

      Kylangan po match para di magkaroon ng problema sa ating windings.

    • @limeoirasecen9502
      @limeoirasecen9502 2 ปีที่แล้ว +1

      Paano po malalaman po...yong mcompresor po..ez90 po Ang code po...ano po Ang Bagay na overload cappasitor Ang pwede po....salamat po sa sagot....

    • @limeoirasecen9502
      @limeoirasecen9502 2 ปีที่แล้ว +1

      @@kamastertvlhonsantelices ka master ez90 po Ang compressor po...ano po Bagay na overload cappasitor Ang Bagay po....salamat po sa sagot

    • @limeoirasecen9502
      @limeoirasecen9502 2 ปีที่แล้ว +1

      @@kamastertvlhonsantelices ganun din po ba Ang relay KA MASTER pareho din po Ang capacity nya po...salamat po sa sagot

    • @kamastertvlhonsantelices
      @kamastertvlhonsantelices 2 ปีที่แล้ว +1

      Ano po brand ng motor sir

  • @albertorpalas4899
    @albertorpalas4899 ปีที่แล้ว +1

    Ka master gud morning.ask ko lng po Anu po Kya Ang sira Ng ref LG double door.hindi lumalamig.1 year po xa d nagagamit ung ref.

  • @GenesisLangcaad
    @GenesisLangcaad ปีที่แล้ว

    Ka master PWD patoru,,, 2 and 3 blings ani ba sira Samsung po,,ayaw omandar ng kompresor,,,80ALR TT6 bagohan langpo ako kamaster,,, salamat PO,,,

  • @allangavinaag
    @allangavinaag 2 ปีที่แล้ว +1

    Maraming salamat kamaster

  • @aljhimodquier1439
    @aljhimodquier1439 4 หลายเดือนก่อน

    boss bakit may lagitik pa rin ang compressor kaht pinalitan ko ng match relay at ok naman ang overload nya.tnx

  • @jhonnabellebustillo1807
    @jhonnabellebustillo1807 2 ปีที่แล้ว

    sir nag hohome serbis po ba kau...dto lang po sampaloc manila

  • @rolandlamoste7795
    @rolandlamoste7795 3 ปีที่แล้ว +1

    goodjob master...godbless po

  • @alexxx446
    @alexxx446 หลายเดือนก่อน +1

    Hi po possible po ba same issue sa ref namin? Nag brown out po kasi bigla, and then pag ka plug after few hours di na po siya lumalamig. Power shock po ba tawag dito and ito yung reason bakit nasisira yung relay?
    Wala po ako exp sa ref pero kung papalitan lang po ba ang olp at relay at gumana naman wala pong problema kung ako na aayus?

  • @RodrigoBandilla
    @RodrigoBandilla 2 หลายเดือนก่อน

    Sir ano po angbipekto pag bumotaw ang relay àt olp ano po ang opekto kung isa lamg po ang bumotaw sa kanila

  • @tuystore2545
    @tuystore2545 2 ปีที่แล้ว

    Sir tanung ko lng normal po ba yun biglang tunog n sa chest freezer.

  • @romillesto1083
    @romillesto1083 3 ปีที่แล้ว +1

    Ok na ok malinaw n paliwanag boss more vedio pa idol

  • @nestorquisido6620
    @nestorquisido6620 3 ปีที่แล้ว +2

    Ka master pag zero ang nakukuhang ampere sa r600a na LG compressor ,tapos 1.5 amps sa name plate model ng unit GR-B519ES0Z,then hindi uminit ang discharge pipe

    • @kamastertvlhonsantelices
      @kamastertvlhonsantelices 3 ปีที่แล้ว

      Check po muna ung compresor windings baka.out of range na..at ung ibang parts supporting sa compressor operation kaya zero ang amps.nia.then check narin ung pressure syempre baka under charge na oh talagang wala ng laman

    • @nestorquisido6620
      @nestorquisido6620 3 ปีที่แล้ว +1

      @@kamastertvlhonsantelices ang winding resistance sir ay heto cs 12.9 then cr 4.9 and then sr 17.9 LG compressor sya at inverter ang refrigerator .tama naman ang resistance,then ung karga -1 ,kahit papaano naman sir iinit ang discharge pipe di ba kung loose compression ang compressor.ano satingin mo sir ang problema

    • @kamastertvlhonsantelices
      @kamastertvlhonsantelices 3 ปีที่แล้ว

      Pag inverter sir dapat equal ung tatlong terminal..

  • @bosscaloy9737
    @bosscaloy9737 ปีที่แล้ว

    Boss yung overload Ng freezer kopo nag babaga kaya po nag automatic na mamatay po agad? Ano puba problema non

  • @ryanperez7706
    @ryanperez7706 8 หลายเดือนก่อน +1

    May overload yan master?

  • @EdwinSison-xg1zp
    @EdwinSison-xg1zp ปีที่แล้ว

    Sir ilang ohms po dapat ang reading ng relay at overload protector

  • @nathanielabellana6944
    @nathanielabellana6944 2 ปีที่แล้ว

    Ka master..ask ko lang sana kung ilang ohms ang relay ng ⅕ hp compressor...sana masagot po salamat.

  • @hermogenesverona1792
    @hermogenesverona1792 3 ปีที่แล้ว +1

    master,tanong Klang kung anong masuggest mong alternative na relay n pwd kong ipalit sa sanyo refrigerator.?
    nag inquire nko sa electrical supply.wala daw katulad ng stock sa sanyo ko.

    • @kamastertvlhonsantelices
      @kamastertvlhonsantelices 3 ปีที่แล้ว

      Kahit di naman sanyo sir..meron at madaming klase ng relay na mbibili tau na kaparehas ng relay ng ref nio.

  • @jeanlayao8309
    @jeanlayao8309 2 ปีที่แล้ว

    Kamaster anung tawag don sa dalawang connecting wire na ikabit sa relay at overload?

  • @JuliusCabelis-kg4uo
    @JuliusCabelis-kg4uo 11 หลายเดือนก่อน

    Kamaster ilang ohms na relay kailangan sa 1/6 na compressor

  • @ricklindamasco2071
    @ricklindamasco2071 2 ปีที่แล้ว

    Master pag nag palit po ba ng relay.wala na po bang code yan.universal po ba lhat ng relay

  • @jammaybanzagales1425
    @jammaybanzagales1425 2 หลายเดือนก่อน +1

    Bagong gawa yng ref okay na sana nagyelo kaagad ngad isinasaksak ko ng mga 7am tqpos bangdang mga 5pm namatay yng compressor o yng motor

  • @patrickfrancisco4375
    @patrickfrancisco4375 ปีที่แล้ว

    sir good day ask ko lang ponsa relay digital po kasi tester ko pag nag continuity test po ako sa relay yung setting ko sa ohms na may sound or beep pero hindi natunog hindi rin sya OL pero may reading ng resistance, itong video same ng lang ref na ito ang problema namamatay sya tas i unplugged lang then plug ulit then back to normal operation then after 10 minutes patay ulit ano po ang trouble? sana makatulong po kayo?

  • @rockykidian3489
    @rockykidian3489 2 ปีที่แล้ว

    Kapag ba mahigit 5 ang reading ng compressor ay sira ang compressor sir?

  • @boyekyotvlogs
    @boyekyotvlogs 2 ปีที่แล้ว +2

    Ka master yung motor nh ref ko .. pag pinagana mo ! Gumagana lang siya ilang minoto ..tapos my pumipitik biglang mamatay yung motor ayaw na umandar ulit..

  • @albertsincebirth
    @albertsincebirth ปีที่แล้ว +1

    Tanong ko: Normal ba na may clicking sound yung start relay every 10 mins? Direct cool 2 door po TCL 4.2 cft

  • @melvinlofranco5758
    @melvinlofranco5758 2 ปีที่แล้ว

    Pwd ba palitan ng 33 ohms or 4.7 ohm relay ang 15 ohms na relay?

  • @eduardotiongson8633
    @eduardotiongson8633 2 ปีที่แล้ว +1

    Ka master pag malakas pa mag yelo ang freezer sira na po ba ang compresor,,2 door po ang rafe ko sa baba po nawala po ang lamig

  • @ahrged6296
    @ahrged6296 2 ปีที่แล้ว +1

    ka master yung ref ko ginawa , pinalitan ng new compressor gumana siya and then umalis na yung repairman, pero after 3 hrs ay nag shot off and pati kuryente ng kabahyan brownout na din. telling story short ang dahilan ay meron short circuit sa ref. napansin ko yung wire sa likod ay mukhang nasunog nagdikit. . hindi nako binalikan nung gumawa. Pwede ba putulin ko ito part na nagdikit na wire and dugtungan ko ng panibago. ...?????

    • @kamastertvlhonsantelices
      @kamastertvlhonsantelices 2 ปีที่แล้ว +1

      Kahit po putulin nio yan since na nangyari na ang trouble..pa gawa nio napo agad yan sa technician.

    • @ahrged6296
      @ahrged6296 2 ปีที่แล้ว

      @@kamastertvlhonsantelices thank you sa reply....
      ginamitan ko ng tester ang relay ay ok naman ... pero yung sa compressor upon test sa cinasabing common and sa compressor body ground ay meron resistance, pumalo yung level ng tester...dapat ba wala resistance .
      wala pa ako makita technician.. kasi yung gumawa nito last month ay hindi na ako binalikan...sa FB lang nakausap yun . Pinalitan naman ng new compressor

  • @eugenecastro6202
    @eugenecastro6202 3 ปีที่แล้ว +1

    Magandang umaga master nais ko ren po sanang ipasuri ang freezer ko syo nagagawi ka po b s pampanga?

    • @kamastertvlhonsantelices
      @kamastertvlhonsantelices 3 ปีที่แล้ว +1

      Nakupo...medyo may kalayuan na sir..dami ko rin sana customer na gsto magpagawa jan sa pampanga.kaso medyo malayo sir.

    • @eugenecastro6202
      @eugenecastro6202 3 ปีที่แล้ว +1

      @@kamastertvlhonsantelices oo nga po master...well thanks anyway s reply godbless po

    • @kamastertvlhonsantelices
      @kamastertvlhonsantelices 3 ปีที่แล้ว +1

      Welcome sir👍👍👍

  • @rubentimbol1326
    @rubentimbol1326 ปีที่แล้ว +1

    Brad ano po Ang problema Ng ref ko Westinghouse magstart after Ng ilang seconds mamatay at kapag hinipo ko Yung overload mainit after mawala Yung init saksak ko start uli tapos mamatay uli, salamat po sa sagot

  • @mariloufajarit6808
    @mariloufajarit6808 2 ปีที่แล้ว

    Hello Ka Master magkano po b yang pyesang nasira?

  • @janeldelacruz8296
    @janeldelacruz8296 ปีที่แล้ว +1

    Master ano po kayang sira ng ref, bigla nalang pong hindi lumamig sa baba. Ngyeyelo naman po yung freezer except sa likod, dina din po masyadong maiinit

  • @julylozada2827
    @julylozada2827 16 วันที่ผ่านมา +1

    sir inverter po ref q bigla nalng di nalamig may ilaw naman sa loob.pag switch ramdam mo na natunog yung relay after 3 to 5 second mamamatay na

  • @jhonnabellebustillo1807
    @jhonnabellebustillo1807 2 ปีที่แล้ว +1

    sir..nagseserbis po ba kau..dto lang po sampaloc,manila

  • @Emengtv
    @Emengtv ปีที่แล้ว

    Gudmorning sir.ask qlang po.bakit po derederetso ang andar ng ref q.malakas po b s koryente.endi po xa namamatay

  • @conradosison4514
    @conradosison4514 2 ปีที่แล้ว +1

    boss walang continuity ang mga terminal ng compressor maaayos paba??

  • @rogerlibrando9890
    @rogerlibrando9890 3 ปีที่แล้ว

    Master pagnakalagay sa running at starting at nakaset sa continuity Ang tester magbabuzzer ba? salamat po

  • @arkanghelkerubin1980
    @arkanghelkerubin1980 2 ปีที่แล้ว +1

    Ka master ask ko lang sir. Ung gngamit nio po pang flashing comp. Non po ba or inv at need parin ba ng cap bago paandarin yun lang po ka master salamat God bless po🙏🙏🙏

    • @kamastertvlhonsantelices
      @kamastertvlhonsantelices 2 ปีที่แล้ว

      Kapag non inverter need po ng capacitor

    • @arkanghelkerubin1980
      @arkanghelkerubin1980 2 ปีที่แล้ว +1

      Salamat po 🙏🙏🙏

    • @arkanghelkerubin1980
      @arkanghelkerubin1980 2 ปีที่แล้ว +1

      Sir or ka master pag paumahin po. Bibili po Sana ako sa junk na comp. Panu ko po malalaman sir kung inv or non po sir alam ko po masasagot nio po yan sir. Censya napo ka master. 🙏🙏🙏

    • @kamastertvlhonsantelices
      @kamastertvlhonsantelices 2 ปีที่แล้ว

      Sa specification po ng compressor rated voltage at desired frequency niya..kapag inverter po ay DC ang output voltage unlike sa non inverter ay AC output

  • @emanbuenaventura118
    @emanbuenaventura118 2 ปีที่แล้ว +1

    Master matagal Mona Po akong taga subaybay tanong ko lang Po Sana bakit Po ganun may ginawa akong ref tapos nag defrost lang costumer ko ayaw na lumamig bakit Po Kaya ganun

  • @skltecht.v9059
    @skltecht.v9059 2 ปีที่แล้ว +1

    ka master nasisira ba ang compressor kapag over charge?

  • @marygraceroxannematias4843
    @marygraceroxannematias4843 ปีที่แล้ว

    anu po kaya sira nito samsung inverter,, bale tumihaya po dahil sa baha pero napatingnn ko na sa technician,, pinalitan na po ng filter dryer ska freon,, ngaun po malamig na pero hndi nman nkkabuo ng yelo yung freezer.

  • @alexanderarabia2445
    @alexanderarabia2445 3 ปีที่แล้ว +2

    Na balik n dn po sir s wakas ung binaklas ng technician. Dumating 4 na po

    • @kamastertvlhonsantelices
      @kamastertvlhonsantelices 3 ปีที่แล้ว +1

      Salamat sa Diyos mam🙏🙏

    • @alexanderarabia2445
      @alexanderarabia2445 3 ปีที่แล้ว +1

      @@kamastertvlhonsantelices thank you po dn po sir aasa po ako n mgawa nyo po ung ref k

    • @kamastertvlhonsantelices
      @kamastertvlhonsantelices 3 ปีที่แล้ว

      Sure po mam..wag po kau mag alala..gagawa pi ako ng bagong design ng wiring diagram niya at mga parts na kylangan bilhin para sa convertion ng Digital to manual..

  • @arjoarcenas7944
    @arjoarcenas7944 2 ปีที่แล้ว +1

    Hello po sir ask co lang po if ano sira. Ng ref namin no frost po magdamag gumagana tapos sa umaga po hindi na gumagana nag frost na po tapos hindi na ulit umaandar after mag frost.

  • @napoleona.alegre6356
    @napoleona.alegre6356 2 ปีที่แล้ว +1

    Excellent

  • @genpilong7094
    @genpilong7094 3 ปีที่แล้ว +1

    sir sira na ang aking thermostant at balak kung palitan peru magkaiba po ang model e bali ang dati ay swtb-8624 1x16 ang ipapalit ko sana ai swtb-r130a ok lang po ba yun? sana masagot salamat

    • @kamastertvlhonsantelices
      @kamastertvlhonsantelices 3 ปีที่แล้ว

      mag iiba po talaga ang model niyan sir lalo pat replacement lng ang ipapalit mo..wala naman po problema jan.as long as same ang mounting....wala po magigin problema dahil kahit magkaiba po ng model eh same lng ang trabho nila..check mo ung cut OFF temp nia nklagay yan sa thermostat mismo

  • @alvincruz9122
    @alvincruz9122 3 ปีที่แล้ว +1

    Magandang araw sir... Tanong ko lng po kung ano kya ang problema ng ref ko bigla nalang po kasi nawala ang lamig... Condura po.. Salamat po"

  • @ronellbadillo3795
    @ronellbadillo3795 3 ปีที่แล้ว +1

    Sir pwede po ba makuha number nyo magpapagawa po sana ako chest freezer.. thank you dito lang din po. Ako sa bulacan

  • @Ma.biancaM.Remoroza-o5o
    @Ma.biancaM.Remoroza-o5o 24 วันที่ผ่านมา +1

    Anu Kaya sira Ng ref KO master umingay ang conprisor Nia mula Ng pumutok sak2

  • @marygraceroxannematias4843
    @marygraceroxannematias4843 ปีที่แล้ว

    hello san po ang area nyo

  • @hilbertros
    @hilbertros 3 ปีที่แล้ว +1

    Magandang araw po Master pwede nyo po ba matingnan yung refrigerator ko sobra init ng compressor every 8 to 10 min. Nagooff yung compressor. Buonaman po yung relay and overload. Ano po kaya possible na sira nya. Thanks po Bulacan lang po ako

  • @estellejeanpama5555
    @estellejeanpama5555 2 ปีที่แล้ว +1

    Sir ung ref po Namin bago pa po .. pero bakit hndi gumagana hndi na uma andar . Pero pag binuksan mo nailaw naman sya. At Tsaka po nangunguryente na sya pag nahawakan mo. Ano po kayang sira nya sir Sana masagot nyo po. Salamat.

    • @kamastertvlhonsantelices
      @kamastertvlhonsantelices 2 ปีที่แล้ว

      Inverter po ba yan mam

    • @estellejeanpama5555
      @estellejeanpama5555 2 ปีที่แล้ว

      @@kamastertvlhonsantelices Hanabishi po tatak. 2 door. Nag grounded po Kasi sya at d na gumagana hndi ko na naririnig na tumutunog.. tingin nyo po sir Ano sira nya. Salamat sa sagot.

  • @arpeemac
    @arpeemac 3 ปีที่แล้ว +1

    Master, itatanong ko lang kung normal ba yung sobrang init na compressor. yung ibabaw nya nakakapaso sa init.

    • @kamastertvlhonsantelices
      @kamastertvlhonsantelices 3 ปีที่แล้ว

      dipo normal...meron tau tamang temperature sa head compressor

    • @arpeemac
      @arpeemac 3 ปีที่แล้ว +1

      @@kamastertvlhonsantelices ano kayang dahilan na masyadong mainit ang compressor? lumalamig naman yung chest freezer. nung isang araw, binuhat namin, medyo na tilt yung lebel nung freezer. may epekto kaya yon?

    • @kamastertvlhonsantelices
      @kamastertvlhonsantelices 3 ปีที่แล้ว

      wag lang masyado naka tagilid

  • @gieperez6043
    @gieperez6043 ปีที่แล้ว +1

    Sir hello po dpo umaandar ang mutor ng ref ko wla po syang ugung ano po kaya possible n sira nya

  • @redmojar05
    @redmojar05 3 ปีที่แล้ว +1

    Master pare-parehas lang ba ng size ng relay at thermal overload para sa ref ng compresor thanks

  • @Pagkahi
    @Pagkahi 3 ปีที่แล้ว +1

    Ka master ano kya sira ng freezer ko, pag marami ang load nya on off siya.

    • @kamastertvlhonsantelices
      @kamastertvlhonsantelices 3 ปีที่แล้ว +1

      Inverter po ba

    • @Pagkahi
      @Pagkahi 3 ปีที่แล้ว +1

      @@kamastertvlhonsantelices hindi po sya nverter . Ano kya dpat gwin dito pag punu lagi namamaty after 30 minutes aandar nanaman tpos patay nanaman ulit.

    • @kamastertvlhonsantelices
      @kamastertvlhonsantelices 3 ปีที่แล้ว

      Kapag sobra sa capacity ng unit..overloaded po tawag jan..ibig sabihin nag rereact agad ung OLP dahil nagsa suffer ng sobrang load ang compressor kaya namamatay

    • @Pagkahi
      @Pagkahi 3 ปีที่แล้ว

      @@kamastertvlhonsantelices so kung ganun normal lang po namamaty siya? 2x to 3x namamatay tas ung matigas na ice lumalambot po. 30 pieces na ice lng po kaya niya e 7 layer po itong freezer namin. Normal po ba un? Bago lng kac namin to nabili.

    • @Pagkahi
      @Pagkahi 3 ปีที่แล้ว +1

      @@kamastertvlhonsantelices kac po malaki itong freezer namin ung uf110 ss fujidenzo po. Pero pag lampas na sa 30 kahit ice candy di na niya kaya. Matatawag bang overload un?

  • @rudypineda8086
    @rudypineda8086 ปีที่แล้ว +1

    Sir pwede p home service sau nwla n ung lmig ng ref k ska basa ung tubo ng compressor

  • @noelitobueno4513
    @noelitobueno4513 2 ปีที่แล้ว +1

    Master anu po tamang reading sa C-S, C-,R at S-R para masabi na ok pa ang compressor?

  • @wilsonviloria7435
    @wilsonviloria7435 3 ปีที่แล้ว +1

    gud pm boss good video
    ask q lng boss kng bkit nagtritrip un overload relay q. ano po kaya dahilan. sna matulongan m aq tnx in advance

    • @kamastertvlhonsantelices
      @kamastertvlhonsantelices 3 ปีที่แล้ว +2

      Aircon
      High amps.
      Overcharge
      Madumi evap at cond
      Ref:
      High amps
      Overcharge

    • @technicalprovlogs6249
      @technicalprovlogs6249 2 ปีที่แล้ว +1

      @@kamastertvlhonsantelices assalam alaykum sadik, kef halak, ask ko lang meron ako d2 ginagawa LG ref, ok nmn lamig nya, nkkpagpayelo lang ng kunti, kc natirik ung compressor, bale naabot ng 8 amp cya.. then cut na over load,. compressor na kya? nde kc ako bihasa sa ref.. shukran kater..!

    • @kamastertvlhonsantelices
      @kamastertvlhonsantelices 2 ปีที่แล้ว +1

      Inverter po ba yan sir

    • @technicalprovlogs6249
      @technicalprovlogs6249 2 ปีที่แล้ว +1

      @@kamastertvlhonsantelices conventional compressor lang cya

    • @kamastertvlhonsantelices
      @kamastertvlhonsantelices 2 ปีที่แล้ว

      Check nio po ung
      Overload protector
      Relay
      Thermostat
      At compressor windings

  • @albertrubian2971
    @albertrubian2971 2 ปีที่แล้ว +1

    Master ano po kya problema ng air cooler ng compressor nmin nagtitrip po kc lgi breaker at nklgay s indicator (overload) ano po mga posible parts n my problema

  • @bryllejackmatutinao3206
    @bryllejackmatutinao3206 2 ปีที่แล้ว +1

    boss..yung ref namin na panasonic non inverter umaandar at lumalamig panaman ..pero after 5mins umaalog ung ref parang sumasayaw pagkatapos ay namamatay at ayaw ng umandar..kailangan pa palamigin ung compressor para umandar ulit per ganun parin mangyayari. sobrang alog tas namamatay..187volts lang ang output sa bhay nmin...patulong lods

  • @michaelmendoza7839
    @michaelmendoza7839 3 ปีที่แล้ว +1

    Master,tanong ko lng ok nmn yun compresor,ok din ang relay,ok din ang overload protector,ok din yun thermostart nia,pero ayaw lumamig ng ref namin?sana masagot mo master!

  • @lanskyrojo537
    @lanskyrojo537 3 ปีที่แล้ว +1

    Hello ka master gusto ko sana i check up ang side by side na ref namin kc nawawala din ang lamig ng ref. Pero ang freezer ok naman. D2 po kami nakatira sa bacolod city negros occidental. Meron po ba kayo partner d2 sa lugar namin? Salamat po.

    • @kamastertvlhonsantelices
      @kamastertvlhonsantelices 3 ปีที่แล้ว

      Wala po problema..kaso napakalayo nio po..

    • @lanskyrojo537
      @lanskyrojo537 3 ปีที่แล้ว +1

      @@kamastertvlhonsantelices master meron po kayo dito partner sa probinsya namin na pwede naming puntahan?

    • @kamastertvlhonsantelices
      @kamastertvlhonsantelices 3 ปีที่แล้ว

      Wala po sir.

  • @ivyisidro2915
    @ivyisidro2915 ปีที่แล้ว +1

    Sir master pag po ba sira ang relay andar parin aba ang compressor

  • @marbelcuran2241
    @marbelcuran2241 2 ปีที่แล้ว

    Hello po ano po kaya prob ng ref nmin ,pinalitan ko na ng relay at overload protector ayaw padin po gumana andar lng ca ng 30 second tigil nanaman po xa

  • @abayseatrip6217
    @abayseatrip6217 2 ปีที่แล้ว +1

    Ka Master paano kaya ito ayaw na umandar ang compressor ng freezer.