Siemens TIA Portal & Factory IO (On Delay TON Timer)

แชร์
ฝัง
  • เผยแพร่เมื่อ 23 ธ.ค. 2024

ความคิดเห็น • 17

  • @PeteVree
    @PeteVree  2 ปีที่แล้ว

    Here is a link to purchase Factory IO. (Note: this is an affiliate link for my channel)
    factoryio.com/url-action?ref=petervree
    Full Siemens TIA Portal PLC Programming Course available here: petevree.thinkific.com/courses/siemens-tia-portal-plc-programming
    Playlist Link for further videos: th-cam.com/play/PLyL0ResmI4Q2Rz5wtTKWhKhFMLnWU1n6Q.html

  • @Otani007
    @Otani007 2 ปีที่แล้ว +1

    thanks for the video , but this video should be added in the 1200 playlist so anyone who watches the playlist can follow the sequence of the project

    • @PeteVree
      @PeteVree  2 ปีที่แล้ว +1

      It should be there already, video #14 in the playlist. th-cam.com/play/PLyL0ResmI4Q3HIWvnMM18XpXkFMsS9Bcj.html

  • @tharunthomas6645
    @tharunthomas6645 6 ปีที่แล้ว

    At 12:05 when you hit the "start pb" why doesn't right hand side of the PLC logic for the "start pb" turn green for the first rung?

    • @PeteVree
      @PeteVree  6 ปีที่แล้ว

      It does for a brief instant, but it doesn't register on the screen as I momentarily pressed the button.

  • @brondeelb
    @brondeelb 7 ปีที่แล้ว

    your video's are great, your explanation makes it easy for me
    i'm just starting with PLC

  • @vinothparker7425
    @vinothparker7425 5 ปีที่แล้ว +1

    hello sir.. I have a small doubt.. why you are not using NC switch for stop push button ??? actually that stop push button is NC type only nah.. then why are you using NO contact in ladder logic programming ??

    • @PeteVree
      @PeteVree  5 ปีที่แล้ว +2

      don't confuse the NO and NC in the plc program and the physical wiring of the switch. The stop is physically wired as a NC switch, which means that at rest, voltage is being applied to the input terminal. The NO contact in Siemens is also called examine if closed in Allen Bradley. It looks for voltage applied to the input terminal or a 1 in the memory. Therefore we have to use the NO contact for both the Stop PB and the Start PB.

    • @vinothparker7425
      @vinothparker7425 5 ปีที่แล้ว

      @@PeteVree thank you for your kind replay sir.. now i understand the concept..

  • @mohanedalfaroq5277
    @mohanedalfaroq5277 6 ปีที่แล้ว +1

    That was awesom

  • @framos9991
    @framos9991 2 ปีที่แล้ว

    Thanks!

  • @alabenachour8943
    @alabenachour8943 5 ปีที่แล้ว

    when i need more piece ??? What do I do to get it

    • @PeteVree
      @PeteVree  5 ปีที่แล้ว

      Piece of what?

  • @juanantonioblazquezcanamer657
    @juanantonioblazquezcanamer657 5 ปีที่แล้ว

    Really usefull and clear. Thanks!

  • @alabenachour8943
    @alabenachour8943 5 ปีที่แล้ว

    Piece of machine ?? Example des vannes, des tubes...

    • @PeteVree
      @PeteVree  5 ปีที่แล้ว

      Within the software Factory IO, you can pick and choose various conveyors, actuators, sensors, etc. th-cam.com/play/PLyL0ResmI4Q38NVKLzouUJdNMu7bA2mH5.html
      The software is available for a 30 day trial factoryio.com/download-factory-io/

  • @ventjemazzel8822
    @ventjemazzel8822 6 ปีที่แล้ว +1

    Great video Pete; Thank you very much for sharing your knowledge with us.