for calculate Fan CFM, buy CFM meter from market, it will exactly tell you the CFM of your fan. Start Fan, put CFM meter close to Fan Jaali and this CFM meter will tell you the CFM of Fan. You can also check each and every Fan CFM.
Assalam o alaikum doctor shb....Hmary shed semi control Hain in mein vents install nhi Hain hum ne hr 10ft k distance m 3 inch k pipe lagye Hain...in se hum kasy calculate krein ghy..qu k jb fan off hoty hain toh b to thori bht Air andr ati hai na
Adab Dr. Saab, I am Arindam chatterjee from India. I have an EC poultry farm 5642 sqf. Just before 3 days 962 bird died due to humidity problem at the age of 40 days approx 2.4 kg body weight. I have 4 exhaust fan ( 54 inch. ) but didn't have air inlet or minimum ventilation. What should i do? and how to control humidity problems in future so that can avoid this type of disaster. pl. Help me.
Kindly static pressure k related bteay ga, agr House ki height 9 ft aur width 46 ft ho tu static pressure in inches of water column kitna hona cheay aur kaisy calculate krty hn...
Generally 0.04 to 0.10 Static Pressure is good for Poultry House....in very tight house and with all fans it will be 0.15...The largest amount of air is moved at 0.00 inch static pressure. As static pressure increases, a fan must work harder and the amount of air moved decreases.
@SantoshKumar-sl8lv 1 second ago IF SHED SIZE 200 X 35 X 10 FOOT , FAN CAPACITY 18000 CFM , NUMBERS OF FAN=3.88 , CROSS SECTION 35 X 10 =350 X 500 FT/MINUTE /18000= 9.72 FAN , SIR THIS IS CORRECT OR NOT , PLZ GUIDE ME, NO. OF FANS ME ITNA DIFFERENCE KYU HAI - 3.88/9.72
@@PoultrywithDrKamran dusre wale formula me shed ke cross section se no. Of fans nikana hai 35 width x 10 height =350 sq foot 350 x 500 foot/minute(air speed)
In 200 Foot shed, desired velocity is 500 foot/minute? why? the thumb rule is to cross the air in one minute, hence required velocity will be 200 foot per minute and your answer will be equal
Dr Sab As usual excellent information Allah aap ko behtreen Sahed de Jazak Allah Khair
Jazak Allah 🌹 Ameen 👍
Behtreen Information 👍 Bht Shukriya 🌹
Jazak Allah
God infarmection dr sb
Shukriya Bhai
Most genius man u are 🎉🎉❤❤❤😊
Great Information 🤠
Jazak Allah
Dear sir very nice information 😊
Very informative video
Mashallah 🐓🐔💎💯🇵🇰💎 karachi
Jazak Allah 🌹
Dr I'm big fan of u
❤️❤️ 🙏
Use for poultry 411 aap best 80% saport
بہترین ویڈیو👌
Jazak Allah 🌹
Good
thanks alot
Jazak Allah 🌹
Jazak Allah
Amazing sir
Shukriya 🌹
Good sar je
for calculate Fan CFM, buy CFM meter from market, it will exactly tell you the CFM of your fan. Start Fan, put CFM meter close to Fan Jaali and this CFM meter will tell you the CFM of Fan. You can also check each and every Fan CFM.
Yes you are right..but here in Pakistan, such things are not easily accessible to everyone and every supervisor..Illaa MashAllah
Good information..sir
Very nice Dr Saab ❤️🥰
Shukriya ❤️
Dr sub good
Jazak Allah
Very Nice Video 👌
Shukriya ❤️
Assalam o alaikum doctor shb....Hmary shed semi control Hain in mein vents install nhi Hain hum ne hr 10ft k distance m 3 inch k pipe lagye Hain...in se hum kasy calculate krein ghy..qu k jb fan off hoty hain toh b to thori bht Air andr ati hai na
Nice bro
aslamoalaikum sir g
W Salam Bhai
Nice sis g nice❤❤❤
Level up 👏
👍👍
💝💝💝
❤️❤️
👍👍👍👍👍👍👍👍👍👍
👍👍
Cage me kitni cfm laini hai dr sb
In minimum or tunnel ventilation
Kindly guide kr dein
Whats App pe rabta kren main guide kr deta hon
Dr sardiyon mein jab 7 degree tak temperature chala jaaye tab ki ventilation formula kya hoga
It will be 0.5CFM per Kg
Sir ji din ko 35 36 hojata ha tmp us wqt kis cmp se ×dain total wazan ko is chart par to sirf 26to 30 tak ha
Us wqt ap per Kg CFM 2 ya 2.5 rakhen gay..baqi formula same rahe ga
@@PoultrywithDrKamran ok sir ji
Sir apne 3rd week ki calculation me w8 ko 2 se multiply kia ha iski samjh ni ai...
Ye calculation in case of winter ventilation no of side fan kalie ho gi ya front fan kalie.?.
Dono k liye
Bhaie Jan namaskar
Mai Nepal se hu
Humko aap se sallah maswara chahiye ki ec close house me
air inlet jaruri hai Kya? aur isse Kya Kitna phayda hai
Adab Dr. Saab, I am Arindam chatterjee from India. I have an EC poultry farm 5642 sqf. Just before 3 days 962 bird died due to humidity problem at the age of 40 days approx 2.4 kg body weight. I have 4 exhaust fan ( 54 inch. ) but didn't have air inlet or minimum ventilation. What should i do? and how to control humidity problems in future so that can avoid this type of disaster. pl. Help me.
Kindly static pressure k related bteay ga, agr House ki height 9 ft aur width 46 ft ho tu static pressure in inches of water column kitna hona cheay aur kaisy calculate krty hn...
Generally 0.04 to 0.10 Static Pressure is good for Poultry House....in very tight house and with all fans it will be 0.15...The largest amount of air is moved at 0.00 inch static pressure. As static pressure increases, a fan must work harder and the amount of air moved decreases.
Day time tepm 38 ho jata hy to pher kasay manage krayn
Answer will be in tomorrow's Video insha'Allah
minimum ventilation kia brooding area ka tamam vents use karain ga......?
According to the bird's requirement
How we check the cfm of fan how we know this fan
Check the company website and download the fan's manual
Mjy ye layer K lye chye cages me
Kya Bhai?
Asalamoalakum sir,Sir jo ventilation app bta rahay,us sy ammonia,Co2,CO increase to nahi hogii,kindly rehnomaii farma den,shukria.
W Salaam.. Increase kesay hogi brother?
I am not telling you to shut ur fans ...Watch closely brother
Shukriaa brother💚
WHEN OUTSIDE TEMPERATURE 45 DEGREE CELCIUS, HOW MUCH CFM REQUIRED FOR 1 KG BODY WEIGHT = FROM INDIA
5 CFM per Kg..I am making a short about your question, Sham ko channel pe dekh lena
Sir , when we open vents 2.5 inches.. then we have to on more fans => more cost..
1.5-2inches is it not okay?
No.. everything is according to the CFM required by the bird
SIR TRANSTIONAL MEANS
In between...din mn kuch, raat mn kuch
Sir India ke liye yahi formula hai
G
@SantoshKumar-sl8lv
1 second ago
IF SHED SIZE 200 X 35 X 10 FOOT , FAN CAPACITY 18000 CFM , NUMBERS OF FAN=3.88 ,
CROSS SECTION 35 X 10 =350 X 500 FT/MINUTE /18000= 9.72 FAN , SIR THIS IS CORRECT OR NOT , PLZ GUIDE ME,
NO. OF FANS ME ITNA DIFFERENCE KYU HAI - 3.88/9.72
Bhai ap ne first mn 200Length rakhi, 2nd mn 500..to difference to aye ga
@@PoultrywithDrKamran dusre wale formula me shed ke cross section se no. Of fans nikana hai
35 width x 10 height =350 sq foot
350 x 500 foot/minute(air speed)
@@PoultrywithDrKamran
No.of fans =cross section x desired velocity/Cfm of fan
500 foot/minute desired velocity hai sir
In 200 Foot shed, desired velocity is 500 foot/minute? why? the thumb rule is to cross the air in one minute, hence required velocity will be 200 foot per minute and your answer will be equal
1700 grm.28500 chik katny fan on ony chainy rat ko g
Ap ka no mil sakta hai sir
Number plz
Sir what'sapp nbr chahiye
0301-7111129
Hlo assalam O alikum sir WhatsApp number
Wa alaikum slam
03017111129
sir ap ka whatsapp number kia he please bta den
Thanks sir ❤😊