I Have replaced 470K Resistor instead of 230K still the same E2 Error code shown. Replacing Bridge rectifier and both IN7004 diodes. I have change 5mfd Capacitor also and The Problem is same as beginning. Plz guide me to solve this error code
@@dhimanvidyutworks Thank You for your reply. I had measure voltages as Ac input voltage is 224V. DC 290v on Bridge rectifier, voltage after both diode is 196v. 146v after 270k resistor, 2.8v after 820K resistor. And 0.9v on pin no.2 of MCU by 10K resistor and 4v on pin no.9 of MCU after 100K resistor. MCU is D1913CNT used. Still shows E2 Code, plz help
Thanks for the Good efforts
Bahut badiya sir ji
Thanks its working.
Super
A1 bro
Th brother
Bina sensar ke bartan sens kese Kiya hume bhi bataiye sir
I Have replaced 470K Resistor instead of 230K still the same E2 Error code shown. Replacing Bridge rectifier and both IN7004 diodes. I have change 5mfd Capacitor also and The Problem is same as beginning. Plz guide me to solve this error code
check output voltage in micro controller ic 2--3 volt
@@dhimanvidyutworks Thank You for your reply. I had measure voltages as Ac input voltage is 224V. DC 290v on Bridge rectifier, voltage after both diode is 196v. 146v after 270k resistor, 2.8v after 820K resistor. And 0.9v on pin no.2 of MCU by 10K resistor and 4v on pin no.9 of MCU after 100K resistor. MCU is D1913CNT used. Still shows E2 Code, plz help
How to contact you? I want to repair my e2 error in pigeon induction
Sir mere pass ek induction hai us me E2 error aa rha aur 1minute k bad off ho jata hai fir button on kare fir chalta hai E2 error pr video bano please
Sensor badal kr dekho
Agar Bo trangister change na Karke aur 2 point barha deta to kya work nahin karta dhanyvad.
Bajaj Majesty
Ye rong video ye sir
Super