Capillary Tube Data Chart for R-22, R-410A, R32
ฝัง
- เผยแพร่เมื่อ 27 พ.ย. 2024
- HVAC TH-cam Channel in English Language:
/ @ayanmechanical
My official Facebook Page “Engr Farman Khan”
www.facebook.c...
WhatsApp Group “HVAC with Engr Farman
chat.whatsapp....
My Whatsapp : +92 3059126576
#capillarytubesize
#ThermostaticExpansionValve
#CapillaryTube
Some Important video Links....
Capillary Tube Data Chart for R-22, R-410A, R32
• Capillary Tube Data Ch...
How Refrigerator works || Refrigeration Principles Practical
• How Heat Transfer in R...
Different Capillary Tubes Vs TXV valve || Effects of capillary Tube size increasing or decreasing
• Capillary Tubes Vs TXV...
R600a Vs R134a Electrical Power Consumption
• R600a Vs R134a Electri...
Leak Detection Device for Freon Refrigerants || Leakage Tracing Easily
• Leak Detection Device ...
Refrigerant recovery information || How to recover Refrigerant 134a from refrigerator.
• Refrigerant recovery i...
Capillary tube,
capillary tube refrigeration,
expansion valve how it works
capillary tube size calculation,
expansion valve adjustment
capillary tube experiment,
expansion valve replacement
capillary tube size chart,
expansion valve setting,
capillary tube pressure,
expansion valve repair,
capillary tube change,
expansion valve in chiller,
capillary tube expansion valve,
expansion valve vs capillary tube,
expansion valve not working,
capillary tube in ac system,
capillary tube length formula,
capillary tube vs expansion valve,
capillary tube replacement,
Capillary tube,
Capillary Tube Vs Thermostatic Expansion Valve,
Capillary Tube Vs TXV,
Different capillary tube effects,
capillary tube size,
how to size capillary tube,
how capillary tube effects,
electronic expansion valve replacement,
FK mech official,
Refrigeration and Air Conditioning,
Refrigeration and Air Conditioning course,
Hvac related course,
Engineer Farman Khan,
basics of refrigeration,
FK mech official,
Thanks
you is an efficcient teacher, engineer,guide and adviser of HVAC system ❤
Thanks Dear brother for your valuable comments ❤️
Nice video sir 👍 hamain intazar h apki agli video ka jaldi upload kariyy ga ShukriA
Thanks Dear brother for your valuable comments ❤️
Good job
Thanks
Sar g dar zabbardast video da
Shukarya Bhai ❤️
Very nice information for Refrigeration system. Thank you
You are welcome Dear Sir ❤️
Very beautiful knowledge
Thanks Dear brother for your valuable comments ❤️
Mashallah sir g
Thanks brother
Nice Sir 👌👍
Thanks Dear brother ❤️
Assalam alaikum good information sir fully 4 world bath aapke video dek raha hoon india se ❤ tamilnadu
Shukarya brother ❤️
@@FKmechofficial duwa me yaad rakna for palestin ke liye
@@mmmyyyy2 zaror Insha Allah
Tamil ah bro
@@ashokarjuna2234 yes bro
Mashallah and beautiful video
Thanks Dear Sir ❤️
Thankyou. Most important i trust you.
You are welcome Dear ❤️
Bhaijan 5 ton ka 3 phace ac hai outdoor me jo capliry use hote hai use zeya Gaye ka use kar sakte hai
Agar capillary tube internally clean hain, to use kr sakte hain
very informative video..
Thanks Dear Sir ❤️
Sir gass kitni psi charge krni chaiye 1 ton 1.5 aur 2 ton and 3 ton ac mehn
Brother, all details next video me gas charging ki
Good 👍
Thanks
Sir lloyd ka ac 1.5 tun non invartor 410 gas me he caplary kitna n lagegi or kitni inch
065" ki awr 2 ft 8 inches
Sir ek a.c dc invertaer se non inverter me convert kiya ha R410 me tha ab maine 32 no ka compressor lgga fiya ha comprssor har 2 din bad thimble jla deta ba plz kuch btaiye
Apne gas zyada charge ki hogi jis se compressor overload ho ke thimble kharab kar raha hai...
Sir , 1 ton lg split smart inverter, r 410-a mein kitne no. & Kitni length ki capillary lagegi,plz reply
059 ya 065 awr Length ...
059 ki 28ft ~30 ft
065 ki 32ft ya 33ft
Sir simple split(non inverter) AC mai R 32 compressor n R 32 gas dal sakty hay?
Yes Dear charge kr sakte hai, agar unit ki piping design R32 ke unit ki tarah ho to
If i change alluminium condenser to copper condenser capillary should change?
No, if you will resize new coil of copper as compared to old aluminium coil,
Then no need to change the capillary tube
Sukriya
You are welcome Dear
The data says about R22 1.5 ton is using single capillary or double capillary? I want to use in copeland CR22K6M reciprocating compressor for 1.5 ton AC.
1.5 TR kelie me ne capillary tube ke data chart me already mention hai,
Double capillary tube ka abhi tk me data chart nhi banaya hai wo next kisi video me zaror banawonga Insha Allah
Sar g cone mashine ma expention valve ki jaga captube istamal kar saktay hay
No Dear, Cone ice cream machine me only TXV hi teek hota hai
Nice sir
Thanks Dear
Sir ye data windo aur split ac dono me use kar sakte hai
Dear bro, ye only split AC kelie hain
Thanks
Ustad G kisi ac main capillary single kisi main double lagi aur kisi kis toh buhat he ziyada lagi hoti hai 4 capillary phir bech main distributor phir 3 capillaries phir kuchh pipe type distributor aur agy phir capillary ye kiya scene hota hai ustad
Yes Dear ye sub details next videos me zaror
Ye data window ac ke liye kam karega sir ,reciprocating or rotary dono compreser ke liye kam karega ye data
Yes Dear of course
@@FKmechofficial thanks sir for reply
Bhai aluminium condenser me copper condenser two roo me capillary change karna padta hai kya video banaye na
Ok Dear noted your point. Thanks 👍
Sir lg ka ac hai non inverter kitne no ki capillary kalegi plz reply me
Kitne TR ka hai ?
Awr konsi gas me hai ?
What if we use 0.80 Capillary 24 Inch Qty 2 For 4 ton Unit
Ya you can keep the 080 capillary but you should keep in mind the type of refrigerant
R22 ke liye signal capillary Kitna use kare kon SA window AC ke liye
Sir ap ki videos bhut achi Hoti han acha ya bataiye ga ka agar aik ton ka window unit ha aur do capillaries lagti han tou phir Kitna lambayi ki lagen gi dono
Two capillary tubes ka pressure drop 60 to 80 psi adjust karen
Sir haier ka ac 1.5 ton inverter R410a refregent mai hai kindly capliery size to bata daiy shukria.
070 capillary tube length 32 inches
10 ton me kitna capillary tube sizs kitna hoga
Assalam walekum window AC split AC ka chart alag alag banaa dijiye thanks.
Carrier 1.5 ton ka hei model hei 42kkl-018 hei temperature nahin aa raha hei or shayad Compressor (1900kb) trip maar raha hei 1/2 -1 ghantei Baad, pahlei original 18" single lagi huee thee capillary no. nahin pata. Ubb kaisei kaamyaab kerein or grill temperature bhi 10-12 mill sakei...
Please batayein poora with length + no. /Diameter of capillary...
Assalam o alaikum sir ap ki video bhut achi ha sir Kuch acs ma do capillaries Hoti han aur Kuch ma sirf aik. Is ki Kiya waja Hoti ha aur Kiya aik ki jaga do hona sa koi khas farq parta ha? Aur 0.75 ton ka ac ma Jo window ha us ma Kiya capillary lage gi
Thanks Dear brother for your valuable comments ❤️,
2 capillary tube lagane se compressor pr overall load kam ho jata hai, leken ye bare units me zyada faida mand hota hai jaha compressor pr load zyada hota hai.
0.75 TR AC me 039 ki capillary tube lagani chahye
Ice plant ke bare mein jankari Den sar aur expansion valve aur sabhi chijen bataen kya kya lagta hai
Ok Dear soon insha'Allah
Sir problem hai ke almunium conder ko nekal ke coper 3.8 pipe single roa ka dala hai 1.5 ton spilt me abb ise unit me cepllery kon c or kitni ho gi? Please reply me urgently??????????❤❤❤❤
Dear aluminium ki jaga agar copper change karna ho, to iska proper calculation hota hai. But any way copper Ka km length aluminium ki zyada length ka kaam karta hai
CR42K TF5, 3TON, r22 CAPILLARY size kitna hona chaihe
70" 24inch 2 pic
80" 16 inch 1 pic
Thank u
You are welcome
3 ton gree ac. R22 capliery size kitni hoge.
090" awr Length 30 inches
Hai sir how r u sir
Sir one dought sir ple slove me
Single door 190ltr samsung fridge
Filter heat and witch problems sir
No condenser heat rejection problem
@@FKmechofficial slove method pls sir
1.5 ton 5100 cooling capacity wale ac kitne Ampere load leta hai full capacity par ?
Depends on Different companies selection have different values of current.
1.5ton non inverter ac aluminium condenser change to 3/8"copper condenser please capaliary data bataye
WhatsApp me
+92 3059126576
sir r22 gas 2.5 ton ac capillary size kitna
2.5 TR me taqreeban 080 capillary 26 inch tk teek hai
@@FKmechofficialthank you sir
@@FKmechofficialsir ager 3tr aur 4 tr,and 5 tr ke size bi batado R 22 aur 410 ke 🎉
R410a ke riplish me R32a dal sakte he ji
Yes, but technically teek nhi hai
Mashallah Mohammad Nadeem Beylim Jodhpur Rajasthan India
Shukarya Bhai ❤️
❤❤❤❤
❣️❣️
Sir mere pass deep fridge he R404a gas ka aor ushme Evaporator he aor ushka Compressor 05 hp he to mereko -20 c karna he Temperature to kitaneki Capillary rakhu
Brother litres me ya cubic ft me iski capacity Kiya hai ?
Sir thanks for Reply.
@Compressor detail-18.0 LRA
@Refigerant-R404a-170gr
@Capacity-610Lt
@Current-4.12A-0.59kw
@Rezistans/Heating Element-300W
@sistembasinci/systempressue-min180kpa-max1800Kpa
Ap 039" ki capillary tube laga Lo. 9ft ki
Thanks sir
@@FKmechofficial sir 0.39 ki jaga pe 0.40 Usekar shak te he 0.39 ki Market may nahi mailti Either to kitani ft lagavu
How many pieces capillary not mention in video sir.
Ya many pieces of capillary tube calculations is little bit more complicated, I will make another video Insha Allah
15 minutes k baad discharge per ice aajati hai evaporate sy start hoti hai kindly rahnumaie farmaey shukria
Gas km issue,
Coils dust issue,
Indoor fan speed issue,
sir we have cake display chiller single phase R404 Refrigerent, I set the set point 2 °c but temperature not reaching the set point value sir what I do sir pls help me . I checked the back pressure 40 psi I flushed the indoor and condensor unit but no temperature coming sir only show 7 °c
Can you show your unit details on my WhatsApp, I want to see pics of your system to guess it's design and construction.
WA +92 3059126576
Window ac me kahi 2 ya 3 hota hai uska kya data hai
2 capillary tube or three capillary tube ka data different hota hai
Voltas1.5tr me 0.70*21" use hota hai
Good
Sir mere ko ek data puchna tha sab fell ho gaye usme R 32 ka compressor tha kisi ne uske ander R 22 ka compressor laga diya or vo new 2 compressor kharab kar chuka hai 2 ton ka ac h vo ab usme R22 ka compressor hai mai usme kitni capillary tube lagau or kitna size kitni lenth aap mujko bta sakte hai kya sir iska koi salutations hai ya fell hai . Aap ki badi meherbani hogi sir please
Brother agar unit design R32 kelie ho awr compressor 22 ka change ho Jaye, to isme capillary tube matching tora sa mushkil ho jata hai
Window 1.5 ton AC usme signal 4no capillary
Laga hai compressors Ka pumping Thora down hai
Usme Kitna no capillary lagaye signal 12 inch 4no laga hai
Sir ha Hvac ka kam karta 10 ton tak caplary tube chart chaye
10 TR kelie bahut jald banawonga Insha Allah
Sir pls 3,4,5, ton ka size batha ye
@@dinakarpune4927 Insha Allah soon
5 .5 ton 80" 18inch *3 pic
4 ton - 80" 20inch *2 pic
3ton- 80" 16inch 1 pic
@tusharroy1606 🙏🙏❤
Sir r32 evaporator temperature condenser temperature hor r410 ka
Agar ambient temp: 40⁰C ho,
R410A cond T: 52⁰C,
R410A Evap: +2 ⁰C
R32 Cond T: 48⁰C
R32 Evap T : -3⁰C
R22 sir kya temperature compressor pressure depend karta hai kya nhi
Sir Maine 35 number ki jagah 36 number ki cappelry lagai hai but compressor trip kr raha hai
Konse unit me awr konsa refrigerant hai,
Required temp kiya hai ?
Tora details se batawo bhai
R32 gas hai
Voltas 1.5 ton window AC hai
@@AP-zt3xs ap mujhe unit ki capacity and size batawo, awr required temp kiya hai apka ?
Refrigrent R134a
Ya
I ton ka split ac hai
No Dear
Sir hammne bi ac technician banana hai aap kaha se hai
Brother me Taxila se hon
@@FKmechofficial sir muje ac technician banana hai tu muje Karachi me koi behtar edara batao jaha se course kar Sako plz
@@Muhammad_171 TEVTA institute se karlo HVAC ka course
@@FKmechofficial HVAC ka nai split ac or fridge ka
@@FKmechofficial ye free Insetute hai ya fees kiya proses hai kitny month ka hai
Kiya R32 gass dangerous hai
@@amarmarwat2226 yes agar oxygen ke sath pressure ki halat me mix ho
@@FKmechofficial وہ کب کس وقت مکس ہوجاتا ہے ۔۔ایک ہفتہ پہلے میں نے لگایا ہے ۔۔ابھی تک کوئی مسلہ نہیں آیا ۔۔۔بعد تو نہیں آئے گا نا۔۔۔
@@amarmarwat2226 ye starting me hota jis waqt technician AC ko install karta hai,
Technician professional hona chahye, to pir wo mixing nhi hone deta hai
@@FKmechofficial میرا مطلب یہ ہے کہ میرا اے سی ایک ہفتہ چلا ہے اس میں ہوا تو مکس نہیں ہوئی ہوگی نا۔۔اب خطرہ تو نہیں ہے
@@amarmarwat2226 WhatsApp karo bhai, me samjhata hon
+92 3059126576
Janab chart mein kum se kum 1 column no. of length bhi lagayein / dikhayein, bahut confusion ho rahi hei. Koee fayda nahin ho raha aapki video dekh kerr PLEASE. poori jaankaari dein nahin toh Kyaa fayeda na he aapnei video mein kahin zikra kiya kitni lagayein 1 ya 2 length... 🤐😇🙄🤔🙁
Inverter AC mai bhi yahi teta rahega sir
Yes of course, both inverter and non inverter
For 5 tons
I will make video soon for 5 TR Insha Allah
Laga kar chek karna aur mujhe comments me batana fir me lagaunga 😢
Ok
Single piece ya two piece me
Single piece Dear
Nice sir
Thanks