Capillary Tube Data Chart for R-22, R-410A, R32
ฝัง
- เผยแพร่เมื่อ 29 พ.ค. 2024
- HVAC TH-cam Channel in English Language:
/ @ayanmechanical
My official Facebook Page “Engr Farman Khan”
profile.php?...
WhatsApp Group “HVAC with Engr Farman
chat.whatsapp.com/BWNFh3gD2n3...
My Whatsapp : +92 3059126576
#capillarytubesize
#ThermostaticExpansionValve
#CapillaryTube
Some Important video Links....
Capillary Tube Data Chart for R-22, R-410A, R32
• Capillary Tube Data Ch...
How Refrigerator works || Refrigeration Principles Practical
• How Heat Transfer in R...
Different Capillary Tubes Vs TXV valve || Effects of capillary Tube size increasing or decreasing
• Capillary Tubes Vs TXV...
R600a Vs R134a Electrical Power Consumption
• R600a Vs R134a Electri...
Leak Detection Device for Freon Refrigerants || Leakage Tracing Easily
• Leak Detection Device ...
Refrigerant recovery information || How to recover Refrigerant 134a from refrigerator.
• Refrigerant recovery i...
Capillary tube,
capillary tube refrigeration,
expansion valve how it works
capillary tube size calculation,
expansion valve adjustment
capillary tube experiment,
expansion valve replacement
capillary tube size chart,
expansion valve setting,
capillary tube pressure,
expansion valve repair,
capillary tube change,
expansion valve in chiller,
capillary tube expansion valve,
expansion valve vs capillary tube,
expansion valve not working,
capillary tube in ac system,
capillary tube length formula,
capillary tube vs expansion valve,
capillary tube replacement,
Capillary tube,
Capillary Tube Vs Thermostatic Expansion Valve,
Capillary Tube Vs TXV,
Different capillary tube effects,
capillary tube size,
how to size capillary tube,
how capillary tube effects,
electronic expansion valve replacement,
FK mech official,
Refrigeration and Air Conditioning,
Refrigeration and Air Conditioning course,
Hvac related course,
Engineer Farman Khan,
basics of refrigeration,
FK mech official,
Thanks - วิทยาศาสตร์และเทคโนโลยี
you is an efficcient teacher, engineer,guide and adviser of HVAC system ❤
Thanks Dear brother for your valuable comments ❤️
Very beautiful knowledge
Thanks Dear brother for your valuable comments ❤️
Sar g dar zabbardast video da
Shukarya Bhai ❤️
Good job
Thanks
Nice Sir 👌👍
Thanks Dear brother ❤️
Mashallah sir g
Thanks brother
Nice video sir 👍 hamain intazar h apki agli video ka jaldi upload kariyy ga ShukriA
Thanks Dear brother for your valuable comments ❤️
Good 👍
Thanks
Nice sir
Thanks
Very nice information for Refrigeration system. Thank you
You are welcome Dear Sir ❤️
Assalam alaikum good information sir fully 4 world bath aapke video dek raha hoon india se ❤ tamilnadu
Shukarya brother ❤️
@@FKmechofficial duwa me yaad rakna for palestin ke liye
@@mmmyyyy2 zaror Insha Allah
Tamil ah bro
@@ashokarjuna2234 yes bro
Mashallah and beautiful video
Thanks Dear Sir ❤️
very informative video..
Thanks Dear Sir ❤️
Sukriya
You are welcome Dear
Bhaijan 5 ton ka 3 phace ac hai outdoor me jo capliry use hote hai use zeya Gaye ka use kar sakte hai
Agar capillary tube internally clean hain, to use kr sakte hain
Thank u
You are welcome
Sir gass kitni psi charge krni chaiye 1 ton 1.5 aur 2 ton and 3 ton ac mehn
Brother, all details next video me gas charging ki
❤❤❤❤
❣️❣️
What if we use 0.80 Capillary 24 Inch Qty 2 For 4 ton Unit
Ya you can keep the 080 capillary but you should keep in mind the type of refrigerant
Assalam o alaikum sir ap ki video bhut achi ha sir Kuch acs ma do capillaries Hoti han aur Kuch ma sirf aik. Is ki Kiya waja Hoti ha aur Kiya aik ki jaga do hona sa koi khas farq parta ha? Aur 0.75 ton ka ac ma Jo window ha us ma Kiya capillary lage gi
Thanks Dear brother for your valuable comments ❤️,
2 capillary tube lagane se compressor pr overall load kam ho jata hai, leken ye bare units me zyada faida mand hota hai jaha compressor pr load zyada hota hai.
0.75 TR AC me 039 ki capillary tube lagani chahye
Bhai aluminium condenser me copper condenser two roo me capillary change karna padta hai kya video banaye na
Ok Dear noted your point. Thanks 👍
If i change alluminium condenser to copper condenser capillary should change?
No, if you will resize new coil of copper as compared to old aluminium coil,
Then no need to change the capillary tube
Sar g cone mashine ma expention valve ki jaga captube istamal kar saktay hay
No Dear, Cone ice cream machine me only TXV hi teek hota hai
Sir , 1 ton lg split smart inverter, r 410-a mein kitne no. & Kitni length ki capillary lagegi,plz reply
059 ya 065 awr Length ...
059 ki 28ft ~30 ft
065 ki 32ft ya 33ft
How many pieces capillary not mention in video sir.
Ya many pieces of capillary tube calculations is little bit more complicated, I will make another video Insha Allah
Sir ye data windo aur split ac dono me use kar sakte hai
Dear bro, ye only split AC kelie hain
Mashallah Mohammad Nadeem Beylim Jodhpur Rajasthan India
Shukarya Bhai ❤️
Sir problem hai ke almunium conder ko nekal ke coper 3.8 pipe single roa ka dala hai 1.5 ton spilt me abb ise unit me cepllery kon c or kitni ho gi? Please reply me urgently??????????❤❤❤❤
Dear aluminium ki jaga agar copper change karna ho, to iska proper calculation hota hai. But any way copper Ka km length aluminium ki zyada length ka kaam karta hai
Thanks
Ustad G kisi ac main capillary single kisi main double lagi aur kisi kis toh buhat he ziyada lagi hoti hai 4 capillary phir bech main distributor phir 3 capillaries phir kuchh pipe type distributor aur agy phir capillary ye kiya scene hota hai ustad
Yes Dear ye sub details next videos me zaror
15 minutes k baad discharge per ice aajati hai evaporate sy start hoti hai kindly rahnumaie farmaey shukria
Gas km issue,
Coils dust issue,
Indoor fan speed issue,
1.5 ton 5100 cooling capacity wale ac kitne Ampere load leta hai full capacity par ?
Depends on Different companies selection have different values of current.
sir we have cake display chiller single phase R404 Refrigerent, I set the set point 2 °c but temperature not reaching the set point value sir what I do sir pls help me . I checked the back pressure 40 psi I flushed the indoor and condensor unit but no temperature coming sir only show 7 °c
Can you show your unit details on my WhatsApp, I want to see pics of your system to guess it's design and construction.
WA +92 3059126576
Sir haier ka ac 1.5 ton inverter R410a refregent mai hai kindly capliery size to bata daiy shukria.
070 capillary tube length 32 inches
10 ton me kitna capillary tube sizs kitna hoga
Sir Maine 35 number ki jagah 36 number ki cappelry lagai hai but compressor trip kr raha hai
Konse unit me awr konsa refrigerant hai,
Required temp kiya hai ?
Tora details se batawo bhai
R32 gas hai
Voltas 1.5 ton window AC hai
@@AP-zt3xs ap mujhe unit ki capacity and size batawo, awr required temp kiya hai apka ?
Sir r32 evaporator temperature condenser temperature hor r410 ka
Agar ambient temp: 40⁰C ho,
R410A cond T: 52⁰C,
R410A Evap: +2 ⁰C
R32 Cond T: 48⁰C
R32 Evap T : -3⁰C
R22 sir kya temperature compressor pressure depend karta hai kya nhi
Sir mere pass deep fridge he R404a gas ka aor ushme Evaporator he aor ushka Compressor 05 hp he to mereko -20 c karna he Temperature to kitaneki Capillary rakhu
Brother litres me ya cubic ft me iski capacity Kiya hai ?
Sir thanks for Reply.
@Compressor detail-18.0 LRA
@Refigerant-R404a-170gr
@Capacity-610Lt
@Current-4.12A-0.59kw
@Rezistans/Heating Element-300W
@sistembasinci/systempressue-min180kpa-max1800Kpa
Ap 039" ki capillary tube laga Lo. 9ft ki
Thanks sir
@@FKmechofficial sir 0.39 ki jaga pe 0.40 Usekar shak te he 0.39 ki Market may nahi mailti Either to kitani ft lagavu
I ton ka split ac hai
No Dear
Sir hammne bi ac technician banana hai aap kaha se hai
Brother me Taxila se hon
@@FKmechofficial sir muje ac technician banana hai tu muje Karachi me koi behtar edara batao jaha se course kar Sako plz
@@Muhammad_171 TEVTA institute se karlo HVAC ka course
@@FKmechofficial HVAC ka nai split ac or fridge ka
@@FKmechofficial ye free Insetute hai ya fees kiya proses hai kitny month ka hai
Inverter AC mai bhi yahi teta rahega sir
Yes of course, both inverter and non inverter
Single piece ya two piece me
Single piece Dear
Laga kar chek karna aur mujhe comments me batana fir me lagaunga 😢
Ok
Nice sir
Thanks Dear