BATTERY EQUALIZATION COMPLETE DETAILS | WHY WHEN & HOW TO EQUALIZE | COOLING FAN RUNNING ALL TIME
ฝัง
- เผยแพร่เมื่อ 17 ก.ย. 2024
- This video is on how to equlize battries Complete details of equlization process, why when and how to equlize battery , why Inverter hang during equlization process, and also why cooling fan running all time. Battery equlization is necessary for long backup and for long life.
...............................................................,.........,
Follow my Facebook Page Talagang Online
/ talagang.onlline
-----------------------------------------------------------------------------------------------------..
inverex aerox 2.2 kw settings | inverex 3.2 kw settings | Complete 36 settings of INVEREX AEROX
• inverex aerox 2.2 kw s...
COMPLETE DETAILS OF SOLAR SYSTEM | COST & TYPES | WHICH SOLAR SYSTEM RUN HOW MANY APPLIANCES PART 1
• COMPLETE DETAILS OF SO...
COMPLETE DETAILS OF SOLAR SYSTEM | COST & TYPES | WHICH SOLAR SYSTEM RUN HOW MANY APPLIANCES PART 2
• COMPLETE DETAILS OF SO...
BENEFITS OF WITH BATTERY SYSTEM | INVERTER GIVES MAXIMUM SAVING WITH OR WITHOUT BATTERY SYS
• BENEFITS OF WITH BATTE...
INVERTER GENRAL FAULTS AND THERE SOLUTIONS PART 2(a) | LESS PV POWER SHOWING | BACKUP NOT ENOUGH
• INVERTER GENRAL FAULTS...
DERATING OF INVERTORS | WHY INVERTOR NOT GIVE COMPLETE WATTS | DERATING CAUSE INVERTER FIRE
• DERATING OF INVERTORS ...
HAIER UPS A.C DEVICE | HAIER UPS DEVICE INSTALLATION | COMPLETE REVIEW | CONNECTION OF UPS DEVICE
• HAIER UPS A.C DEVICE |...
WHY SOLAR PANELS BURN OR LEAVE HOT SPOT | HOW TO PREVENT FIRE HAZARD FROM PANELS
• WHY SOLAR PANELS BURN ...
MANUFACTURING PROBLEM IN INVERTOR | MANUFACTURING FAULT IN INVEREX AEROX 2.2 | BOTH POLE POSITIVE
• MANUFACTURING PROBLEM ...
BEST INVERTOR SETTINGS FOR BATTERIES | WHY BATTERIES CHARGING 24 HOURS | BEST SAVING FROM INVERTORS
• BEST INVERTOR SETTINGS...
2.2 SOLAR SYS HOW MUCH EFFECT YOUR ELECTRIC BILL???
• INVEREX AEROX 2.2 SOLA... .
HOW TO INSTALL INVEREX 2.2 AS A UPS (without solar)
• HOW TO INSTALL INVEREX...
Using of relay between wapda and invertor, complete details ,price etc
• Using of relay between...
-------------------------------------------------------------------
Copyright Disclaimer under Section 107 of the copyright act 1976, allowance is made for fair use for purposes such as criticism, comment, news reporting, scholarship, and research. Fair use is a use permitted by copyright statute that might otherwise be infringing. Non-profit, educational or personal use tips the balance in favour of fair use.
------------------------------------
Subscribe my Channel
Like, Comments and Share the Video
Jazak Allah. You are a real gem. 100% genuine information.
Sir thanks for comments,
ماشاءاللہ بہت خوب مقبول اللہ تعالیٰ آپ کو کامیاب کرے آمین
Baht achy bahi gan
کافی انتظار کے بعد آخر battery equalization
پر آپ کی ویڈیو آہی گئی. شکریہ
Sir Jazak Allah apke support k lye
Very very informative video.keep it up👍
mashallah good upload very interesting video stay connected 👍 like
بالکل یہ ھی مسئلہ میرا انورٹر کر رھا تھا میں انوریکس سروس سنٹر کے کئی چکر لگائے مگر حل نہ ھوا تنگ آکر میں نے انوریکس ویرون5۔2 کو اتار کر سارا سسٹم کو ایک ایم پی پی کے ذریعے انہیں بیٹریوں پر ڈی سی لوڈ پر منتقل کر کے سکون کا سانس لیاجوکہ نا صرف کم خرچ ھےبلکہ واپڈا ،مہنگے مہنگے انورٹر ، پینلز اور بیٹریاں خرید کر ے سے جان چھوٹ جائیگی۔میں آپکا شکر گزار ھوں کہ آپکی ویڈیو نے اھم ٹیکنیکل معلومات فراہم کیں۔
Bahut Khoob sir
good information, thanks .
Very informative sir g
Best description. 🎉
🌹🌹🌹ماشاءاللہ🌹🌹🌹
Mashallah sir g good
سر 1.2 کلو واٹ پر بھی ویڈیو بنائیں مکمل سینٹگ کی
Ok sir
Thankyou very much..detail review good job...i hv a buy 3.2 aerox inverex inverter but it doesn't charge on generator.i need to charge it on generator twice a month for 3 to 4 hours due to loadshedding but it doesnot connect with generator.i also enhance generator 50hz and above power but not fruitful..kindly make a detail video on it and guide the solution
Ok sir i will check and confirm
@@solar-wala-bhai2903 thanks i will wait
Go to setting 16 & select CSO.
Thn start charging from generator it will start charging in 10mts
I m also facing the same issue, it doesn't charge from 5kva Generator 😔
Ma'sha'Allah.
Very good sir
Best info
جزاک اللہ زبردست ویڈیو سر ! جناب میرا سوال یہ کہ اگر گرد یعنی واپڈا سے بیٹری کو کم ایمپیر سے چارج کرواییں تو بجلی کے یونٹ زیادہ استعمال ہونگیں۔ اب میر ا تجربہ کچھ یوں ہوا کہ کچھ دن بیٹری 20 ایمپیر پہ چارج ہویی تو یونٹ کم تھے جیسے 10 پہ کیا تو اگلے 9 دن میں پچھلے 12 دن کی کثر نکل گیی
Sir ok hum b iss issue ko dekhtey hn
Bohat Khob Bilal Bhai, Apka Kehna Yehi Hai Na Ke Equalisation Usi Sorat Active Hogi Jb Batteries Puri Tarha Charged Hongi Yani Bulk Charging Kebad Floating Charging Pr Achuki Hon Chahey Ham Usi Waqat Equalisation Start Karna Chahen Ya 30-35 Days Ka Period Pre Define Kiya Huwa Ho Chahey Grid input Active Ho Ya Grid Breaker Off Kiya Huwa Ho. Aisa He Hai?
Sir bilkul exactly aisa he h
Sir ap ko Allah khush rakhe
Mismatched solar par bhi video banaye eg: 330w 150w
Ok sir i will try
Very nice video. Thank you bhai.
Firvi kuch sawal hai ......
1. 150AH c10 x2 batteries ke liye , equalization voltage or amp kitna hona chahiye ? Or kitni der tak chalu rakhna chahiye ? Kyuki mere pas jo PCU hai, usme equalization mode nahi hai, mujhe ye alag se karna parega. Please, help by replying.
Good
Battry equalization ko hone k liye kitna time dena ha setting me se. Default settings me 60 set ha. Isko kum zyada bhi krne ki option ha.to kya isko itne pe e rehne dein. Masla ye ha k 60 minut me batteries kafi garam ni ho jaengi?
sir equalization hidden hogi? jb battery 29.2v ja chuki hogi . esy hi ha? mane sara proses kiya ha. battery 29.3v pr ja chuki ha. pv se 18A arhy hain. kya equalization ho rhi hogi
Sir exactly, Eq show hota h srf
@@solar-wala-bhai2903
shukria sir
kindly.setting set krwa den
inverex veryon premium 2.5kw + 3 pannel 575 canadian hain
tx 2500 2 Phoenix hian
charging 20A Soler aur 10A utality
float 27v
bulk 29.2v
cutt off 21v
sir set ka maza nhi arha. battery jb 23.5v pr ati ha to low battery ka alarm ata ha. battery k main point se pani charging k waqt baher nikalta ha..jb k full tight hain.
bulk 28v rkhen to battery backup km deti ha. kindly.zra setting share kr den
Sir equalization eik mataba karne ke baad dubara khud b khud hogti rahegee ya 30 din ke baad phir manual tarique se inverter ko equalize karna parega. Pl. Issue guide lines Thanks.
Sir automatically hoti rahey ge, lekn kuch inverter ke khud b krni parti h
اگر آپ کی ایروکس 3.2 کی سیٹنگ کی کوئی ویڈیو ھے تو برائے مہربانی بتائیں
Mere pass solor max 3.2 r 4 series ka inverter instal he aur phoenix tx 1600 tubler battery's he 10 din qabal instal kya he iski equalization kitne din bad huni chaye aur konse no ki setting ko kiss par selection karni he app buht achi tarh samjhty he sir plz gide kejy
Sir 1 month k bad kr lien equalization kerien,
30 no per enable kerien EEN, OR PHR 36 NO PER ACTIVE KERIEN BAKI ISS TOPIC KE VIDEO KA LINK B BHEJ DETA HON
th-cam.com/video/Xg7R-hQxv4I/w-d-xo.html
@@solar-wala-bhai2903 every month equalisation krna . ?
G bilkul sir
Assalamualaikum
Sir mene abhi inverex veyron 3.2kw ka inverter install kia 18.01.2022 pe
Fan aik har waqat chalta hai without load bhi
Batteries Full pe chalta hai
Iss se pehlay vmiii 3.2 kw ka fan khud ba khud jub load nae hota tho off hota ta.
Kindly reply kareein .
Thanks
Sir its normal in these models
Ser ye fan chalne ka ziyada masla siraf inverex main hai max power tesla main ye bettery full ke bad band ho jate hain aur kam load per b band rehte hain
Thanks for sharing
Please answer
Equalization mein load chalega aur load Mein Koi Fark To Nahin aaega
Ni sir koi farq ni parta , equalization hoti he tb h jb ap ke battries Complete charge hon
Mere bhai equallization kab tak ki jatee hay eik ghante keliey ya poory din ke liey umeed karta hoon k sahi guide line bataiage shukriya. With Regards shaikh usman.
Sir 1 ghanta enough h , 30 din k bad ke jaye to bhtr h, agr batteries porani hn to 20 days k bad
Solarmax sg1212 ke settings ke vedio hy?
Sorry sir
Salamoalikom Bahi inverx inverter 3.2 kw par 2hp submersible pump chalasakty hi ya nahi
Sir chalna to chahey, experiment ker lien ,
Assalamu alakaum sir mere pass fronus 6kw inverter hai is ke sath tubular battry lagai hai.is pr battry equalisation enable nahe hota
Sir please contact on WhatsApp 03216557487
Sir max power sg1212 k fan forever chalty rehty hai... Wapda chal raha ho ya battry charge b ho fan kbhi b bnd nhi hoty
Any solution plz
Agr load inverter k through chal raha ho to fan chalien gey
Sir kya load direct Wapda Sai chal Sakta hai 1.2 kw inverext Mai ?
G bypass hobk chalta h
Sir may equilization ke 30 day select Karo or 30 day say phaly inverter ko manual off kero Tu keya phir start say din shoro honge ya continue din chaly gay
Inverex 1.2 kilowatt inverter gravity Kyon Nahin banata battery ki
Sir AP na kha hai ka dry bettey ki equalization ni hoti Mera pas battery cell hai us pa e9 ka error a raha hai Mai is ki equalization kesa kro
Sir E9 warning, uss ke equalization ke zarorat ni h
Sir agr aerox 1.2 k sath me 600 watt (150x4) ki panels lagaon ya me sirf 150 watt ki 3 panels lagaon to is sy me apni 100 ya 200 amp ki battery ki Equalization kr skta hun?
Regards
G ho jaye ge
@@solar-wala-bhai2903 thanks dear brother
Salam sir mere pass inverax 1.2 Invertor he us me fault 03 aa raha he or buzzer continues on he pls guide me
Sir yeh fault battery k high voltage ka h , ap ney battery kon se use ke h , or agr aik sey zyada lagai hn to kesey lagai hn, or may be Apka inverter over charging kr raha h , agr over charging ka problem h to phr apko service center jana parey ga , but pehley battey ke specifications bata dien
@@solar-wala-bhai2903
Sir mery sath bi yh same issue aya hy Veyron 1.2 new model py.
Jb earth ki wire remove ki phr thek ho gya
Aoa dear mane mera Aerox inverter 3.2 hai sath 185A ki 2 bettry lgayi hain 2 weeks pehle or sath ma 435w k Canadian 6 pannal lgaye hain ab problem ye hai k ma jab bhi uspar load dalta hon to wo sath ma bohat zayada bettry power leta hai pannal 1000w se zayada nahi de rahe 2nd jo bettry backup hai wo bas 3 se 4 ghnte hai 400w load par so mjhe kisi ne bettry equalisation ka kaha to mane jese ap ne btaya wo kiya hai aaj rat ko par ab smjh nahi aa raha k equalisation hogi kab or mjhe pta kese chale ga k hogyi? Please help with quotations
Sir i think your problem is discussed in WhatsApp
Assalamu Alaikum mere pass 2.2 ka setup hai inverter battery Khud cutoff nahin karta breaker se karni padati hai
Breaker sey kesey cutoff krtey hn sir?
Agar aik battery ka volt 11 hay awr dosry ka 12 volts hay
Kya equalization say dono ki volts barabar hajaye ge ?
Very confused about this.
Sir nitrox 6k2 hybrid VS fronus matrix 6kw vs onyx dual pv 9000.
Konsa best hy in me se?
12v-150ah 2 year used
kitny volt rkhen Equl k liye ?
or kitna Duration rkhen ?
please Help
AoA: Phoenix 110 AH ki 4 batteries lagayee hui hain 48v karnay ke liye... Battery ke sath jo manual aaya hay usmay Bulk voltage 58.4 likha hay aur Floating voltage 54 hay... To ab ismay equalization voltage kya rakhain? Kindly rehnumayi kardain. JazakAllah
Sir by default b rakhien to thek h
@@solar-wala-bhai2903 : JazakAllah aapke reply ka.
But Inverter mai By Default Equalization 58.4 hee set hua wa hay aur Battery ke sath jo manual aaya hay usmay Bulk voltage 58.4 likha hay...
Inverter Fronus 6 KW hay
Sir ok , i. On installation, free ho k bat kerta hon
@@solar-wala-bhai2903 JazakAllah
Mairai pas ziewnic 1.5 inverter hai is Mai equlize ki setting nahi to kistra Mai apni batery ko equalize karo please giide
Cell bank jis me 104 cell series me lage ha lakin masla ye araha ha k 4 days bad charger equalizer mode me chala gata ha
Ye kya isshu ho sakta pa...
Plz rehnumai kare
Sir cell kon sey hn or charger kon sa h ?
Asalam Sir
Meray pas nitrox 5 kw hai os me battery equalization kaisey krna hai
Bhai mere pass fronus 3.2 kw inverter hai Bettery full nai hotien 27 tak tu jatien hain per full nai hotien pehle 2.5 kw pe bettery 28.5 tak jatien thien konsi setting karun bettery full charge ho
Mere inverter ke fan chalte hi nai hen inverter 60 degree ka temperature show kar Raha hota ha
Sir new batteries ko equalization karna chahye ya nahe.
After 3 months sir
Salaam.
Ma Nay Bhi Veyron 1.2Kwa install Krwaya Ha Jo Keh Filhaal Solar panel K Baghair Sirf Wapda Say Chalaraha Hun.Problem Ye Ha K Battery full Honay K Bawajood Bhi Fan 24 Hours Chalata Rahta Ha.Kindly Agr Solution Bata Dain To Mashkoor Rahunga
Bhai agr me 400watt ka 1 solar panel lon aur 150watt k 2 solar panels lon to Kya me inko aerox 1.2 me use kr skta hun? Neez me connection kesy kron ga?
Regards
Sir kr saktey hn but itney achey results ni milien gey, 150 watts ko series mn kr k 400 k sath parallel kr dien
@@solar-wala-bhai2903 sir Kia in solar panels se me Haier ups enabled ac din ko free use kr skta hun(aerox 1.2) k sath.?
Regards
G sir bilkul chala saktey hn
@@solar-wala-bhai2903 thanks sir.Allah apko khush rakhy Ameen.
Regards
Aameen, jazak Allah
Sir mere pass ags sp 250 he 150 ke 6 plate he 3 ke series he suddenly ye fault ho gaya he
Sir panels 2 + 2 + 2 hn ya 3 + 3 hn, ?
Bhai ap ki to Osaka ki batteries thi?? On ko kiya hova?
Sir merey pas falcon h , osaka kisi or k ghr installation ke hoge wo apney dekhi hoge
Dear Bhai. Mere pas Suoer 40amp charger he aur 100 amp Phoenix battery he.battery ka dosra saal he.pehly battery full hony pe charger auto cut ho k current stop krta tha magr ab 2 mah se battery charge to hoti he blky boht heat up ho jati he lekin charger se cut off ni hoti...Kia ye waja to ni he k charger 14 volt pe la kr isy cut off krta tha lekin ab battery 14 volt pe ni full ho Rahi aur heat up b isy lye ho Rahi he aur cut off b ni ho Rahi?? Ap is bary me Kia kehty Han?
Regards
Sir agr heat ho rai h to definitely over charging ho rai h ,ap 13.5 pey charge ker k dekhien ,
@@solar-wala-bhai2903 sir ye Suoer company ka charger he aur is me voltage set krny ka option ni he blky sirf ampere km ya zyada krny ka button he.
@@solar-wala-bhai2903 sir ye Suoer company ka charger he aur is me voltage set krny ka option ni he blky sirf ampere km ya zyada krny ka button he.
Ok phr battries ko check kra lien jo battries expert hotey hn
@@solar-wala-bhai2903 ok sir .so kind of you
Bahi bahi Mere inverter k fan wapda pe b band nahi hote mtlb band hi nahi hote kabi b aik chlta hi rhta ha.
Means batry full hone pe bypass mode pe unhn band ho jana chahiye donu ko lkn aik chlta hi rhta ha.
2ndly plates nahi laggi huien. Aik month k 300 units kha gya ha self consumption pe.
Sir bypass k doran b load is sey ho k jata h iss lye load wala fan chalta h , baki bhtr h k ap panels use kerien , kion k charging 600 + tk leta h phr normally b 200 + watts leta h charging k lye iss lye faida tb he hoga jb ap panels use kerien gey
@@solar-wala-bhai2903 thank you so much. Such a great person with reliable info and alway be there for help and info.
Always welcome sir
ایف 13 کا فولٹ ارہا ہے کیوں انفنکس 2.2 جو اپ دکھا رہے تھے اس کے اوپر ایف 13 کا فالٹ اتا ہے وجہ بتائیے گا
Sir need repair
Bulk option nai ha
10 hr Discharge test k bad charger auto pa equalizer mode pa on howa ta..
Sorry i just saw your comments,
Kitny time tak equalization on rakhy jab khud kry
bhi ya to ap nay two relay lagahi hain in bta dain
Sir is ko kitny ghnaty Equalization kry plz.. Replag
1 hour is enough
Battery equalization setting mein battery equalization time out likha aata hai
Yeh kahan tak set karna chahie aur kitna hona ya rakhna chahie
Usko default per he rakhien
@@solar-wala-bhai2903 Mera inverx 3.2kwh Inverter 120 min hi show karta hai automatically
Bhai mere pas Fronus 1.5kv ka inverter hai, Pehlay 0w load py fans band ho jatay thy after charging completely but pechlay kuch dino se band nai ho rhe 0w load py bhi sardiyan hain is ke bawajood! Fans ki awaz bht hai raat ko bht shor hota hai isla so nai sakty! Koi acha hal bta dein, sari settings default py hain kuch change nai kiya sivay flooded battery ke option ke!
Ye bhi bta dein ke kya iske fans change kerwa lene chahiye mujhy to some silent fans ta ke shor kam ho, dusray ups inverters se tau bht hi zyada shor hai iska
Equalisation automatic setting pe hosakti ha?
No sir
@@solar-wala-bhai2903 sir inverter ma jo setting hoti ha k kitni din bad equalisation ho. Phir wo kis liye hota ha
Sir its set to equalize battries every month, but if battries need immediate equalization then Active 36 no settings
Equ volts 245v
Flute 233 v
Please share details of system
Is system k sayh relayyyyy keo lgi hoi ha?
Sir its not necessary , but if you want to know about this then this video will help you 👇👇👇👇👇
th-cam.com/video/xgJZThmEvDY/w-d-xo.html
Bahi mre ups ka aik fan to chalta rhta ha. Theek ha kia ye
Sir normal h garmion mn
Sir mere pass aerox 3.2 he magar charging stop Nahi karta battery 27 par full ho jati he magar pir bi charging stop Nahi hota ao charge Ka signal blank karta rehta he jis se battery heat up ho jati he solution bata de sir
battery full charge karnay kai baad bhi agar fan chalta rahay toh kia yai normal hai?
اسلام علیکم بھائی
میرے گھر میں انوریکس 2.2 انورٹر لگا ہے
میں نے 280 واٹ کے 2 پینل اور 180 واٹ کے 2 پینل لگائے ہیں
180 والے دونوں پینل سیریز میں کر کے 280 والی پیرلل میں لگائے ہیں
میرے پاس 2.2 سے پہلے ns کمپنی کا 1.2 انورٹر لگا تھا اور پینل یہی تھے
مسلہ یہ ہے کہ 1.2 سے جو پاور آتی تھی وہ 24 وولٹ اور 27 ایمپیر تھی
اور اب 2.2 سے جو پاور آ رہی ہے وہ 400 واٹ سے زیادہ نہیں آتی
حالانکہ پینل وہی ہیں اور کنکشن بھی ویسے ہی رکھے ہیں
اس مسلہ کا کوئی حل بتائیں
نوازش ہو گی
السلام علیکم بھائی صاحب ورون.1.2. کلو واٹ کے فین ہر وقت چلتے رہتے ہیں لوڈ اف ہو یا ان ہو چاہے واپڈا بھی ان نہ کی ہو یعنی کہ ان پٹ اؤٹ پٹ کچھ بھی نہ ہو بس ویسے ہی یہ چلتے رہتے ہیں اور صبح تک بیٹری ڈرین کر دیتے ہیں اس کا کیا حل ہے اور انورٹر کو سٹینڈ بائی پہ کیسے کرتے ہیں
Sir yeh problem h in inverter mn, standby srf relay sey ho sakta h
Mera wapda pay bhi fan hota hain. 200watt pay bhi
Yes fan ka issue h, but barey inverter mn fan fully automatic hotey hn, matlb slow or noiseless hotey hn
Maine Fronus 3.2kw liya hain. Fan ki waja se abhi main as a UPS use kar rahi hoon. Solar panel vesay bhi nahi lagaya.
Sir, fan continuously running even after complete charging. and on bypass mode
What to do?
Sir after 7 pm check kerien without load or without charging, but floating charging agr ho ge tb b fan chaley ga ,jb k uss time battrey indicator full show ho raha hota h
These process possible with 1.2kw inverter ?
G sir you can
@@solar-wala-bhai2903 which is better aerox 1.2kw vs Maxpower sg1212
Sir Aerox is best but i suggest you to buy 2.2 as only 5000 Rs difference between both of these ,
@@solar-wala-bhai2903 2.2 single battery sported hy ?
No sir , double battries supported , iss year ap 2.2 with battries or 2 panels 330 k use kerien , iss pey itna he kharcha hoga jitna 1.2 pey hota h , next year 3 panels or laga lejye ga
Sir meei battery RT ko backup NH de rahi plz help me
Sir battery equalization kerien backup normal ho jaye ga
@@solar-wala-bhai2903 sir kyse mujy NH ATA
th-cam.com/video/Xg7R-hQxv4I/w-d-xo.html
Watch this
@@solar-wala-bhai2903 okk bro pr ek masla Hy mera off grid Hy
*cell bank
104 cell
1600ah
Charger equalizer mode setting 90 days
Plz plz plz
Sir please contact on WhatsApp
Sir 3..3 ke series he
Sir 2 + 2 + 2 ke series ker k dekhien , or agr possible ho to setting ke video merey WhatsApp no 03216557487 per bhejien
jub equlisi compte hojaye to k se pata chalega
Battery equalisation kab on or off karni chahiye
Bro F13 ka fault kiaaa h book mn b nh
Sir when this fault came ?
@@solar-wala-bhai2903 DC voltage Range 102 hai Inverter ki 0r Men 119 DC Volt in kar rhaaa thaa tab ye fault aaa rha tha shukria ap k jald jwab ka
Sir sorry, but ap poch letey k late reply kion kia to bhtr tha bjaye tanz k , mn heat stroke ke waja sey 3 din hospital tha or aj kuch bhtr hua to reply kr raha hon sab ko
@@solar-wala-bhai2903 tanz nh hai apko laga.
Allah Apko Shifaaa den Tandrusti Den
Jazak Allah
Janab apse contact kese kya jae?
SALUTE
Aur mere pass Upar 1600 what hai
G panels enough hn ap k pas
Sardion may fan bohok kam chalta hay
G bilkul, temp kam hota h , but jin logon ney inverter andar kisi room wagera mn lagaya ho to un k fan sardi mn b chaltey hn
Good
Sir
1.2 kilowatt inverter battery ki gravity ko complete Kyon nahin karta
Reply