Sir. When you select the type of fault, you randomly draw the line on the circle? What actually the meaning of drawing the line amd where to start the line?
Dear Sir thanks for explaining, but I have one thing about Z-offset you did Divide by 2 but do not need it because the Z-offset is coming from d'/2 . i wait your reply.
Hi, I am try for this principal make advanced model for generation 6,3 kV, 36MVA, Xd=1.4 and I get result R1=0,5645, X1=-0,62377, R2=1,08384, X2=-1,14311. And I try testing but It doesn't work. Did I good calculation this resistance?
Voltech Eco Tower, No. 2/429, Mount Poonamallee Rd, Ayyappanthangal, Chennai, Tamil Nadu 600056, India Phone: +91 44 4397 8000 V Equal IR T&C Service No.4, 2nd floor, 1st Avenue, Akshaya Colony, Mogappair, Chennai - 600050. Mobile :+91- 7397331813 / 7397331814
Most of my doubts can be clarified from your videos
thank you and most welcome
Very well explanation Anna. Thanks for make the video.
You are welcome 😊
Nice Content bro, , very well explanation, , thanks you 🙏
thank you bro
Nice .please give a detailed ...explanantion of on testing of distance protection
i will try to make
Thanks for your VDO presentation.
welcome
Great sir...
thank you
Very good. Thanks 🙏🙏
Most welcome 😊
Sir pls make video on ,motor thermal over load protection in detailed explain the weighting factor and how to read thermal overload curves .
sooon i will make
Sir.
When you select the type of fault, you randomly draw the line on the circle? What actually the meaning of drawing the line amd where to start the line?
to check the boundary protection
i would like a explain, how to test it, with my siemens Relay 7UM85 Siprotec 5--- i dont know hoy to found offsets...
later i will make video regarding this than you.
Dear Sir
thanks for explaining, but I have one thing about Z-offset you did Divide by 2 but do not need it because the Z-offset is coming from d'/2 .
i wait your reply.
i am not taking from d'/2 so i use this formula
Hi, I am try for this principal make advanced model for generation 6,3 kV, 36MVA, Xd=1.4 and I get result R1=0,5645, X1=-0,62377, R2=1,08384, X2=-1,14311. And I try testing but It doesn't work.
Did I good calculation this resistance?
Hi sir
Which software you are using for graphical representation?
only PPT
🙄👌
THANK YOU
Sir I want to learn relay. Basic and all types relay training center please send me location are name of institute
Voltech Eco Tower, No. 2/429, Mount Poonamallee Rd, Ayyappanthangal, Chennai, Tamil Nadu 600056, India
Phone: +91 44 4397 8000
V Equal IR T&C Service
No.4, 2nd floor,
1st Avenue, Akshaya Colony,
Mogappair,
Chennai - 600050.
Mobile :+91- 7397331813 / 7397331814
Why do you divide X offset by 2? It do not give any sense.
offset value to plot impedance starting point. from center it have equal both end