C2000 delta vfd me chitting ke bare me batayen jaise ke keypad me speed jo setting hai barabar hai Lekin motter speed up down hota hai kaha se cheda jata hai
आपके डेल्टा me ड्राइव पर cd3 त्रुटि कोड W-चरण वर्तमान दोष को इंगित करता है। इसका मतलब है कि ड्राइव, ड्राइव से जुड़े मोटर के W चरण के माध्यम से प्रवाहित होने वाली धारा में असामान्यता का पता लगा रही है। शक्ति को चक्रित करें. मल्टीमीटर का उपयोग करके ड्राइव आईजीबीटी की जाँच करें
O0-05 Software Version Settings Read only M00-07 Parameter Protection Password Input Settings O-65535 Display O~4 (the times of password attempts) A Pr.00-07 and Pr.00-08 are used to prevent the personal miss-operation. A This parameter allows user to enter their password (which is set in Pr.00-08) to unlock the parameter protection and to make changes to the parameter. A When the user have forgotten the password, clear the setting by input 9999 and press ENTER key, then input 9999 again and press Enter within 10 seconds. After decoding, all the settings will return to factory setting. Settings O-65535 A All parameters will be read as O when the password is setting, except Pr. 00-08. M90-08 Parameter Protection Password Setting Factory Setting: Read only Factory Setting: 0 A To set a password to protect your parameter settings. In the first time, password can be set directly. After setting, the value of 00-08 will become 1, which means password protection is activated. When the password is set, if any parameter setting needs to be changed, be sure to enter correct password in 00-07, and then the password will be inactivated temporarily with 00-08 changing to 0. At this time, parameters setting can be changed. After setting, re-power the motor drive, and password will be activated again. Password Decode Flow Chart Password Setting 00-08 0: No password protection / password is entered correctly (Pr00-07) 1: Password has been set A To cancel the password protection, after entering correct password in 00-07, 00-08 also needs to be set as 0 again to inactive password protection permanently. If not, password protection will be active after motor drive re-power. £A The keypad copy function will work normally only when the password protection is inactivated temporarily or permanently, and password set in 00-08 will not be copied to keypad. So when copying parameters from keypad to motor drive, the password need to be set manually again in the motor drive to active password protection. Displays 01 after correct password is entered to Pr.00-08 Password Forgotten 00-07 Enter 9999 and press ENTER, then enter 9999 again within 10 se conds and press ENTER. Then all parameters will reset to factory settings. Factory Setting: 0 00-07 Password Incorrect 3 chances of password input: Incorrect password 1: displays "01" Incorrect password 2: displays "02" Incorrect password 3: "Pcode"(blin king) Keypad will be locked after 3 wrong attempted passwords. To re-activate the keypad, please reboot the drive and input the correct password.
Etna details video abhi tak koi NAHI banaya.thanks sir ❤❤
Delta vfd waring digramm setting all details very useful video sir thank God 🙏
You are welcome
Very good information about electrical vfd information and informative video. Thanks sir❤❤
Most welcome
Nice video very informative videos all details thanks 🙏🙏
Most welcome 😊
Useful electrical vfd related video thanks you
Welcome
Useful video and informative information 👍 ❤❤
Very useful
Thanks a lot
Video nice sir
Nice video very helpful from Himachal Pradesh
Thanks and welcome
Ap bot achy sy samjhty ho
Nice video sir
Thanks
Very useful video sir ❤. Full details 👍 👌
So nice of you
Awesome video 👏
Thanks for the visit
Bhut badhiya
Very nice
Thanks
Nice sir
Thanks and welcome
Nice video
Thanks
Super easy
Yes 😊
❤❤❤❤❤
Mtech make
Expret vt 240s model vfd ka bhi full explained karke dikhaye please
Kk bahut jald hi apko details video milega ok ji
Thanks for joining my ruchi electrical team
Full video dekhiye please. Full details hai trip realy ka bhi hai.731 run. 732 trip ka prameter h
Bohat informative but sound speed bohat fast samjny mn problem hy
Ok next time. Hum acha try karunga ji.
Thanks for watching and joining my ruchi electrical team
C2000 delta vfd me chitting ke bare me batayen jaise ke keypad me speed jo setting hai barabar hai Lekin motter speed up down hota hai kaha se cheda jata hai
Voltage dropping
Sir pid me reverse signal ..matlub 0 per high 10 per low.. ka vedio banao
Yes -o hz per full speed aur _10hz per low speed
@@Ruchielectrical 0 voltage per high
10 v per low
Dc
Sir cp2000 driver ka motor farved and reverse setting kay se karthy thoda batava
Pura video dekho
Details bataye hai
Is vfd me Trip really ka programming kaise kare
Full details video dekhiye please. Sab kuch hai esame.trip realy ka bhi.
731 run
732 trip
Prameter h ok
Sir hamare pass sem yahi vfd problem le hai ki 3 feas voltage nahi aa rha ha to kya karna padega
Kuch display me error aata hai kya .mujhe bataw please
Error code bataw mujhe .
Aur cable termination check kijiye
Output cable nikal ke voltage check kijiye
Apne settings me input voltage kitna setting kiya hai.
Aur moter voltage pura details mujhe bataw please
C2000 ka video chahiye
th-cam.com/video/Wv-uBk4wNhg/w-d-xo.htmlsi=E3jxOUdpXEZLeaU5
C2000 ka details video hai please full watch
Frequency increases and decreases push button se karne ke bad stop 0.00 frequency kaise ho ga
Minimum frequency o.oo set kijiye sahi ho jayega. Phir bhi problem ho to aap vfd reset karke dubara se set kijiye sahi ho jayega. Ok
Sir Sara parameters set karne k baad bhi Motor Over load pe trip nahi ho rahi he , kahi pe parameters disable ka option to nahi he na??
Yes enable kar dijiye sahi ho jayega.
Thanks for watching and joining my ruchi electrical team
Sir Cd3 (Ics sensor Error) Fout Aa raha he kese sol kare
आपके डेल्टा me ड्राइव पर cd3 त्रुटि कोड W-चरण वर्तमान दोष को इंगित करता है। इसका मतलब है कि ड्राइव, ड्राइव से जुड़े मोटर के W चरण के माध्यम से प्रवाहित होने वाली धारा में असामान्यता का पता लगा रही है।
शक्ति को चक्रित करें.
मल्टीमीटर का उपयोग करके ड्राइव आईजीबीटी की जाँच करें
Hame moter ko speed jyada karna hai drive se kaise kare help
Vfd settings me maximum hz set karo 50hz.
Ya moter rpm moter ka name plate me dekh ke usaka full rpm dalo
Moter full speed ho jayega ok
C2000 VFD ka Lock 🔒 hai batayen
Prameter
00.07
00.08
Default password
9999
CP2000VFD Lock torana ka settings batayen
O0-05 Software Version
Settings Read only
M00-07 Parameter Protection Password Input
Settings O-65535
Display O~4 (the times of password attempts)
A Pr.00-07 and Pr.00-08 are used to prevent the personal miss-operation.
A This parameter allows user to enter their password (which is set in Pr.00-08) to unlock the
parameter protection and to make changes to the parameter.
A When the user have forgotten the password, clear the setting by input 9999 and press ENTER
key, then input 9999 again and press Enter within 10 seconds. After decoding, all the settings will
return to factory setting.
Settings O-65535
A All parameters will be read as O when the password is setting, except Pr. 00-08.
M90-08 Parameter Protection Password Setting
Factory Setting:
Read only
Factory Setting: 0
A To set a password to protect your parameter settings. In the first time, password can be set
directly. After setting, the value of 00-08 will become 1, which means password protection is
activated. When the password is set, if any parameter setting needs to be changed, be sure to
enter correct password in 00-07, and then the password will be inactivated temporarily with
00-08 changing to 0. At this time, parameters setting can be changed. After setting, re-power the
motor drive, and password will be activated again.
Password Decode Flow Chart
Password Setting
00-08
0: No password protection / password is entered correctly (Pr00-07)
1: Password has been set
A To cancel the password protection, after entering correct password in 00-07, 00-08 also needs to
be set as 0 again to inactive password protection permanently. If not, password protection will be
active after motor drive re-power.
£A The keypad copy function will work normally only when the password protection is inactivated
temporarily or permanently, and password set in 00-08 will not be copied to keypad. So when
copying parameters from keypad to motor drive, the password need to be set manually again in
the motor drive to active password protection.
Displays 01 after
correct password is
entered to Pr.00-08
Password Forgotten
00-07
Enter 9999 and press ENTER,
then enter 9999 again within 10
se conds and press ENTER.
Then all parameters will reset
to factory settings.
Factory Setting: 0
00-07
Password Incorrect
3 chances of password input:
Incorrect password 1: displays "01"
Incorrect password 2: displays "02"
Incorrect password 3: "Pcode"(blin king)
Keypad will be locked after 3 wrong attempted
passwords. To re-activate the keypad, please
reboot the drive and input the correct
password.
Sir f1. f2. f3. f4 Esaka setting kaha se hota hai
Apne pura video dekha
Samajh me aaya nahi apko.
Pura video dekho kuch bhi problem ho mujhe bataw aap ok
Full details video very useful 👌 and informative video ❤❤
Thank you so much 🙂
Nice video
Thanks
Very useful
Glad you think so!
1
❤❤❤