Brother ji, bahut hi achhe se samjaya aap ne, bahut hi achhi jankari diye hai aap ne, brother aapka Dil se dhanyawadh karte hai aur aapki video ko like bi karte hai, assi hi knowledgeable video banate raho, hum bi like, share, comment karte rahenge, thanks
Your videos is very descriptive and you are a perfect teacher too. I have a questions relating this video. Q. What specifications should I need to make a step-down transformer 230v ac to 130v ac of 1.5 kw/ampere? e.g. * core and bobbin size, * wire gauge and turns for both primary and secondary windings. * Any others things which I forgot to mention here.
Primary me 20% jyada current carrying capacity yani 20% jyada cross section wala wire lena hoga losses ko compensate karne ke liye. Iss power ke transformer ki efficiency 80% maan ke design karenge.
Great Way to Explanation Shukriya but i have some questions, Kya Alu aur Copper wire dono me Amp aur Volt same niklega? Kya U type core ke liye calculation same rahega?
Sir maine ek 2000 watt ka 48v to 220v se calculation kiya to primary windings 57 turns and secondary 280 turns aaya but wire dia 8mm aa raha hai, joki impractical lag raha, kya ye capacity ka transformer ban sakta hai ?
Nice sir but table ka bhi screen shot de sir v 750mili ampier 9volt ka kaise banaye please bade transformer ka to sab ne bataya par chote ka kisi ne nahi bataya
@@LUCKYELECTRONICSLAB inverter t/f me primary me 0 140 220 260v or secondry me 12 0 12 hota hai. Q:- 0 & 140v 0v 220v 0v 260v Tino condition me se kisi me bhi AC supply dene par sevondry me 12 0 12 hi milta hai kya ? Currents diffrent hota hai kya ?
Nice explanation!! Thanks !! I have a 600va APC ups rated at 360Watts, how can I increase the watts !? Do we need to rewind the transformer!!?? If I can increase how far we can increase the watts like up to 400w or 450w or 500w !?? Could you please help 🙏🙏
Isko khud kuchh nahi aata , ye tum ko kia samjhae ga, iss se ye poochho ye4.44 kia hay , ye10 ×8 kia hay , aur ye kia hain kore saize ke number kahan se le aaya ,totak watt 300 , jiun farz kar liya, wire gage nikalney ka tariqa bhi iss ne ghalat bataya hay .
@@LUCKYELECTRONICSLAB tum abi bachchay ho, jitni tmhari umr hay uss se ziada mera tajruba hay. Tumhain to may abhi parakh leta hun, aik transformer banana hay jiss ki secondary may:- 24--0--24 volts 4.5 A + 4.5 A current Single winding 13.5 v. 700 mA current 3.7 volt 100 mA current Ab calculate kar ke batain:-- 1. Secondary ka total load kitney watt huwa. 2.primary per kiney watt load hoga. 3.primary me 220 v per kitney A current khrch hoga. 4.primary winding ke liye kitney swg ka wire lage ga. 5.secondary ki tino windings ke liye kiss kiss number ke swg wires ka istemaal hoga. Iss transformer ke liye kiss size ki core chahiye hogi, core ka size inches ya centi meter me bataiye. Core number nahi chalay ga , core number anariyon ka kaam hay. Agar aap ye transformer desine kar lain tao me aap ko man jaunga.na kar pa ain to mujh se maaloom kar lijiyey ga.
आपका सिखाने वाला है दिल्ली बाजार श्री श्याम जी ध्यान बनाकर डायग्राम दिखा रहे ऐमेझान जैसा नुक्लियर डर लगता केजरीवाल की पहचान चिल्लर भाव खाती हो मतलब शनी
सही से नहीं बताया आपने एंपियर के बारे में तो डिस्कशन किया ही नहीं व्हाट किसे पता होगा पहले से , हमको ट्रांसफर बनाना होता है तो हमको volt पता होता है घर का और करंट हमें जो चाहिए वो हम ले सकते हैं तो इससे watt निकाल सकते हैं और आपने जिस तरह से बताया उसमें क्या करंट फिर 1 एंपियर ही मिलेगा आपने 1.36 एंपियर करंट निकाला था। volt ओर amp चाहिए होता है हमें तो पहले । मुझे 220 वोल्ट से 12 वोल्ट का ट्रांसफार्मर चाहिए तो watt पहले से कैसे डिसाइड कर लूंगा पहले करंट डिसाइड करूंगा ना उसके बाद ही watt निकलेगा पहले से पहले से कैसे निकाल लूंगा । 220 से 12 का ट्रांसफार्मर तो चाहिए पर हमें current कितना amp चाहिए इस पर डिपेंड करेगा watt मुझे 12v और 5 एंपियर का करंट चाहिए तो बताओ कितने गेज का वायर लगेगा और कितने वाट का ट्रांसफॉर्मर होगा तो सही से समझ आएगा । दूसरा आपने बताया 4 no कोर के लिए 1.5×2.5= 3.75 मतलब 4 के लगभग और वहीं 6no के लिए 1.75×2 = 3.5 ये तो 6 के लगभग नहीं है फिर, और turn par volt TPV mujhe ye bhi sahi se samjh nahi aaya TPV यानी 1 turn में जितने वोल्ट यानी चार नंबर कोर के लिए 2 TPV है तो 12 वाल्ट चाहिए तो 24 टर्न और AC 220 के लिए 440 टर्न हो जाते हे तो आपने 100 कैसे लिखे । मुझे तो ऐसे समझ में नहीं आया, सही से बताइए आपको एक तरफ एक 220 या फिर 170 जो भी लेते एक ट्रांसफार्मर के बारे में बताना था खाली सही से ,4 एक साथ अलग अलग वाल्ट वाले ट्रांसफर के बारे में नहीं बताना चाहिए था । मुझे तो यह समझ में नहीं आ रहा कि टर्न किस हिसाब से लगाए हैं फिर , यदी tpv से टर्न निकलते हे तो उस हिसाब से तो टर्न हे ही नहीं , 12 वाल्ट जिधर हे उधर सही है बस बाकि तो मुझे समझ में नहीं आया । बताओ तो पूरा क्लियर क्लियर सही से बताया करो ना ताकि लोगों के क्वेश्चन ही ना आए बड़े बड़े
Brother ji, bahut hi achhe se samjaya aap ne, bahut hi achhi jankari diye hai aap ne, brother aapka Dil se dhanyawadh karte hai aur aapki video ko like bi karte hai, assi hi knowledgeable video banate raho, hum bi like, share, comment karte rahenge, thanks
Brother main ne buhat see videos dekhi hain lekin.apki video sab zyada achi lgi.yeh star ap ke liye.****************♥🤗♥🤗♥🤗♥🤗🌹
Best video on Explanation for transformer designing have seen ever.Thanks a lot..
Bahut badiya samjha rahe hai AAP sir very good sir
Thank you sirji nice video mostly usefull knowledge
भाईसाहब...आपने बहुत अच्छी तरह से समझाया है।...धन्यवाद। लेकिन ऐक दफे विडियो देखने से काम नही चलने वाला। आप का बहुत-बहुत आभार मानते है।...✒Ⓜ.
Very very nice. Thanks for detail explaination
A notable classroom tutorial. Thks to Master & chnl.
Very nice good video .brother❤
Good very good brother.👍🏻
Thank you sir for this information 🥰🥰
Big thumbs up👍🏻👍🏻fot the content of this video
This information will help me very much
Super. Thanks bhai ji
धन्यवाद भाई साहब अंदाज धान की पावर पर बताया जायेगा श्रद्धा
💓👉Very nice video 😊
Your videos is very descriptive and you are a perfect teacher too. I have a questions relating this video.
Q. What specifications should I need to make a step-down transformer 230v ac to 130v ac of 1.5 kw/ampere?
e.g. * core and bobbin size,
* wire gauge and turns for both primary and secondary windings.
* Any others things which I forgot to mention here.
Core no 7B 2.5 × 3"
TPV - 1, primary turn 230 and wire gage 17 no swg , secondary turn 130 and wire gage 15 no swg
@@LUCKYELECTRONICSLAB Thank you very much for your prompt response. Can I operate a 110v microwave oven on it?
@@damodarkoirala6131 same configuration ka hoga to kr sakte ho
You can calculate with these formulas for any input to any out puts
thanks for all details. 👍
Super 👌👌👌👌
बहुत अच्छा धन्यवाद सर
good video
Ye hota he full formula thanks
Very good sir.❤
Primary me 20% jyada current carrying capacity yani 20% jyada cross section wala wire lena hoga losses ko compensate karne ke liye. Iss power ke transformer ki efficiency 80% maan ke design karenge.
Very good
Good tutorial video.
V good sir
Thanks so much dear friends
Great Way to Explanation Shukriya but i have some questions,
Kya Alu aur Copper wire dono me Amp aur Volt same niklega?
Kya U type core ke liye calculation same rahega?
Alu aur copper me volt to same niklega but current me diff hoga
1000 waat 12v ek ups transformer banaye ?
Very nice. Thanks.
Sir 1.2 amp
Or 15 amp ke liye konsa wire gauge use hoga please btaye
Amp chart nahi hai google search kro sab hai
I have 15 inch bobin 5 x3 and needs 1000 watt transformer. Input primary is 115 volt. Required 25 volt 40 ampere. what number of wire it needs?
Primary 16 swg 57 turn
Secondary 10 swg 12 turn
Inverter ke liye kya double tar kam me lega kya sir ye bataye
Ha double lagega
Sir maine ek 2000 watt ka 48v to 220v se calculation kiya to primary windings 57 turns and secondary 280 turns aaya but wire dia 8mm aa raha hai, joki impractical lag raha, kya ye capacity ka transformer ban sakta hai ?
Ha ban sakta hai single tar nahi mil rha to double ya tripal ya 4 tar parallel lapet ke ban sakta hai core area bas thik hona chahiye
Thanks for u sir ji
Nice video
nice video ,sir i have confusionb ,when you are using 0-12 volt single winding wire guage will also change
Yes
टन॔ निकाल ना समझगये लेकिन वायर गरज निकालना नहिसमज पाये
Bhaiya 300watt ke liye kitne inch ka core lagega?
Nice sir but table ka bhi screen shot de sir v 750mili ampier 9volt ka kaise banaye please bade transformer ka to sab ne bataya par chote ka kisi ne nahi bataya
Chhote trans hand se bnana bahut muskil hai
nice
Sir aapne 300 watt bataya hai .yeh o/p aur i/p volt aur amp ka sum hai kya
O/P ka watt hota hai aur input ka bhi 300 watt 220 volt pe lega 300 watt 12 -0-12 pe bna ke dega
Bhai 200 watt k liy core no or wire gauge bta dijiye
16 amp ka lagega
Core or wire swg bta dijiye acche se
@@TheShaan7 kal bhej dunga apna email bhej do ya watsup no
sk0105287@gmail.com
Bhai 5000w ka transformar ke bareme samjaye or input volt 12 he to amp Kitana dena palega video banye
5000 watt ka inverter transformer bana hai
Very good video
We're to buy bobin and core?
Local market
my required specification is 12 to 13.5 volt and 25 to 40 amH (ampare hour) power source. how to build this. please guide
Bhai mere Ampare hour ka taaluq battery se hota hay transformer se nahi. Aap tao ye batain ke kitnay Ampare ka transformar banana hay.
Or videos banaoo sir plz plz🙏🙏🙏
Sir efficiency aapne nahi bataya , kya hota hai
85 percent
I wish to wind this transformer in copper winding please help me
Sir mera specifications are 15v:220v 2000w-2050w and ampere 85amp step up transformer solar inverter kit ko lagane ke liye hona.please help me sir
Winding karne ko difficult ho raha hai
Sir 12 no wire 15 ampere hi leti hai
लंबा गणित युटिब एकादशी का कारण ऐक नबर है क्या लगे लिस्ट बाहर निकल होल आते है
Swg chat amp ka hisab say kaha mill sakta hai
Uska book ya abb bhi hai net se bhi mil jayega
Sir 3no core se bana sakte hai kya
Ha bobin badha lagega
Is Data same for aluminium and copper wire?
Yes
Total cost kitne paregi???
Kitne watt ka tx
200 watt
@@shuvodipchatterjee9162 500 ke lagbhag
nice bto
Namskar sir
Mere pas 3 no. Core 1.75 inch h. Mujhe us se 24-0-24 5amp transformer banana h. Please uske liye data or wire no. Bataye.
Ok ak do din lagega
1.262×1.75 ke liye primary turn 782 wire swg 27 no
Secondary 81 turn 24 volt 18 no wire
TPV 3.40 v
Sir mere pas ek transformer h 3.2cm × 5.2 cm hai bobbine size iska core number kya hoga bataye sir
12 012 v, 3amp type ke bare me kuch bataiye
500 ampier welding machine ka Transformer bataiye sar three phase
Sir three phase transformer calculation formula bataye
सर amp swg चार्ट बताइये,,,
Mail kro send kar dunga
👏👏👏❤️❤️
300 /12=25 amp secondary current......but swg12 wire max. current capacity is 13.5amp...as per chart...
12 no swg wire 24.68 amp deta hai ji
@@LUCKYELECTRONICSLAB inverter t/f me primary me 0 140 220 260v or secondry me 12 0 12 hota hai.
Q:- 0 & 140v
0v 220v
0v 260v
Tino condition me se kisi me bhi AC supply dene par sevondry me 12 0 12 hi milta hai kya ?
Currents diffrent hota hai kya ?
@@abhishekkumar-mm6bt 220 me 12, 0, 12 aur 260 me 10, 0, 10 aur 140 me 14,0,14
Thank jee
Transformer ka amp, turns, swg, pura detail me bataiye
Pura video dhyan se dekhiye jo samajh na aye puchhiye
Need more videos
According to chart 25 amp is 8 wire swg
Nice explanation!! Thanks !! I have a 600va APC ups rated at 360Watts, how can I increase the watts !? Do we need to rewind the transformer!!?? If I can increase how far we can increase the watts like up to 400w or 450w or 500w !?? Could you please help 🙏🙏
Rewind krna hoga mote wire se
@@LUCKYELECTRONICSLAB thanks ! For what target watts I can rewind so that the ups handle the extra power and current
Very nice explaination. Thanks
थैंक यू सर
Praymari1000watt secondori40v incoming 230 v outgoing 40v per Vidov bnai e
Ok banega
Bobin size nehi Batye
Kitne watt ka chahiye
Thanks so please
sir
12 0 12 = 24volt hota ha
12 sa divide Q kiya sir
Inverter transformer hai isliye 12 se hoga normal transformer hota to 24 se hota
Isko khud kuchh nahi aata , ye tum ko kia samjhae ga, iss se ye poochho ye4.44 kia hay , ye10 ×8 kia hay , aur ye kia hain kore saize ke number kahan se le aaya ,totak watt 300 , jiun farz kar liya, wire gage nikalney ka tariqa bhi iss ne ghalat bataya hay .
@@hashmatkhan6371 jo core kisko kehte hai nahi janta jo ye dimansion kisme rehta hai ye nahi janta wo hame galat kehta hai pehle study kro fir bolna
@@LUCKYELECTRONICSLAB tum abi bachchay ho, jitni tmhari umr hay uss se ziada mera tajruba hay. Tumhain to may abhi parakh leta hun, aik transformer banana hay jiss ki secondary may:-
24--0--24 volts 4.5 A + 4.5 A current
Single winding 13.5 v. 700 mA current
3.7 volt 100 mA current
Ab calculate kar ke batain:--
1. Secondary ka total load kitney watt huwa.
2.primary per kiney watt load hoga.
3.primary me 220 v per kitney A current khrch hoga.
4.primary winding ke liye kitney swg ka wire lage ga.
5.secondary ki tino windings ke liye kiss kiss number ke swg wires ka istemaal hoga. Iss transformer ke liye kiss size ki core chahiye hogi, core ka size inches ya centi meter me bataiye. Core number nahi chalay ga , core number anariyon ka kaam hay.
Agar aap ye transformer desine kar lain tao me aap ko man jaunga.na kar pa ain to mujh se maaloom kar lijiyey ga.
three phase transformer calculation formula
wair gej chart bhej dijiye
Very good night
Thanks so mach baby
आपका सिखाने वाला है दिल्ली बाजार श्री श्याम जी ध्यान बनाकर डायग्राम दिखा रहे ऐमेझान जैसा नुक्लियर डर लगता केजरीवाल की पहचान चिल्लर भाव खाती हो मतलब शनी
सही से नहीं बताया आपने एंपियर के बारे में तो डिस्कशन किया ही नहीं व्हाट किसे पता होगा पहले से , हमको ट्रांसफर बनाना होता है तो हमको volt पता होता है घर का और करंट हमें जो चाहिए वो हम ले सकते हैं तो इससे watt निकाल सकते हैं और आपने जिस तरह से बताया उसमें क्या करंट फिर 1 एंपियर ही मिलेगा आपने 1.36 एंपियर करंट निकाला था। volt ओर amp चाहिए होता है हमें तो पहले । मुझे 220 वोल्ट से 12 वोल्ट का ट्रांसफार्मर चाहिए तो watt पहले से कैसे डिसाइड कर लूंगा पहले करंट डिसाइड करूंगा ना उसके बाद ही watt निकलेगा पहले से पहले से कैसे निकाल लूंगा । 220 से 12 का ट्रांसफार्मर तो चाहिए पर हमें current कितना amp चाहिए इस पर डिपेंड करेगा watt मुझे 12v और 5 एंपियर का करंट चाहिए तो बताओ कितने गेज का वायर लगेगा और कितने वाट का ट्रांसफॉर्मर होगा तो सही से समझ आएगा । दूसरा आपने बताया 4 no कोर के लिए 1.5×2.5= 3.75 मतलब 4 के लगभग और वहीं 6no के लिए 1.75×2 = 3.5 ये तो 6 के लगभग नहीं है फिर, और turn par volt TPV mujhe ye bhi sahi se samjh nahi aaya TPV यानी 1 turn में जितने वोल्ट यानी चार नंबर कोर के लिए 2 TPV है तो 12 वाल्ट चाहिए तो 24 टर्न और AC 220 के लिए 440 टर्न हो जाते हे तो आपने 100 कैसे लिखे । मुझे तो ऐसे समझ में नहीं आया, सही से बताइए आपको एक तरफ एक 220 या फिर 170 जो भी लेते एक ट्रांसफार्मर के बारे में बताना था खाली सही से ,4 एक साथ अलग अलग वाल्ट वाले ट्रांसफर के बारे में नहीं बताना चाहिए था । मुझे तो यह समझ में नहीं आ रहा कि टर्न किस हिसाब से लगाए हैं फिर , यदी tpv से टर्न निकलते हे तो उस हिसाब से तो टर्न हे ही नहीं , 12 वाल्ट जिधर हे उधर सही है बस बाकि तो मुझे समझ में नहीं आया । बताओ तो पूरा क्लियर क्लियर सही से बताया करो ना ताकि लोगों के क्वेश्चन ही ना आए बड़े बड़े
नया समान लेने वाले कहा हो यह बात व्यवहार रूप रेखा वाले
मराठी किंवा हिंदी मध्ये भाषांतर करा
Sir mere ek transformer banana he to plz.to tumhare nombar send halp mee 🙏🙏📞
45 0 45 ka 8 A ka banane ke he
Mail se kam nahi chalega
@@LUCKYELECTRONICSLAB nombar send bro🙏📞
Bht short kia hy !!!!
Aap ka formula bahut galat hai 🙏
Ye practicle kiya hua formula hai chek krlo
check Kata hu ok sar
.
Thanks so mach baby