@@PEARLENGINEERING1 thanku for rply sir maine maicanic bulaya thaa usne bola star contactor kharab h 4500 price bola h ...stater puri working condition m thaa bas 1 saal tak chalaya nhi
Sir kabhi agar start push button on Karo to chalu hota he lekin dubara band karke chalu Karo to nahi hota he Khali control ke upar on off hota he lekin motor start nahi ho rahi he to Kya karna chahiye
सर जी मेरा मोटर स्टार में स्टार्ट हो जाने के बाद में जैसे ही डेल्टा में जाता है ट्रिप हो जाती है तीन-चार बार ट्रिप हो जाने के बाद में स्टार्ट किए तो स्टार्ट होता है इसमें क्या फॉल्ट है सर
That was an extremely informative video, thanks Brother!!
Verry nice sir ❤️
Very excellent understanding
Thank u sir ... Grt knowledge abt starter
Nice explainationb bhai tnx
Very nice 👍👍
Sir aapne अच्छा विडिओ बनाया हैं. Very nice sir 👌
👌👌👌 very informative
Very good.
Awesome brother
Hi sir
Sir 10hp ka motor hai to overload relay me kitne amp par set karenge please
Depend on motor full load current,, approximately 17 amp
Thank you sir .
Sir dol ka bhi video bano
क्या हम स्टार,और डेल्टा कॉन्टैक्टर को by पास करके डायरेक्ट main contactor में चला सकते हैं,चलाने से क्या प्राब्लम होगा
Ha chala sakte hai,, jyada bari motor 10 hp se jyada ko pahle slow speed me chalate hai fir full speed pe..
Excellent
CHAKKI KA MOTOR KA STARTER ON KRNE PR MOTOR KI SPEED DHEERE DHEERE SLOW HONE LGTI H KYA H RESON 10 HP KI MOTOR H
Check load (ampere) of motor
Also check output voltage ..
Ho skata ho jam lag raha ho chakki me..
Problm solve ho gai
Werry gud sir maja agya
Sir star delta contactor on ho raha hai but main contactor on nahi ho raha hai how to rectify this fault
Must video
nice video❤️
Sir please make vedio of star delta control wiring .
Ye video deko
th-cam.com/video/9oXQfebCYyM/w-d-xo.html
Thanku sir ,
Very good sir
Very nice
Nice sir
If trips after sometime what to check
Sir Delta mai jaise hi on hota hai trip kr jata hai kya problem ho skta hai
Overload relay trip karta hai..ya only contactor band hota hai..
@@PEARLENGINEERING1 Contactor band ho jata hai
Check star nc also timer no
Sir power jate hi Delta lag jati hai or koi cotactor on nahi ho raha hai. Please help me.
Hello sir nice video mere stater m star nahi chal rha time 10sec baad direct delta chal raha hai kya dikkat ho skti h??
Check timer nc..or star coil
@@PEARLENGINEERING1 thanku for rply sir maine maicanic bulaya thaa usne bola star contactor kharab h 4500 price bola h ...stater puri working condition m thaa bas 1 saal tak chalaya nhi
@@PEARLENGINEERING1 40 ampere 3 phase 415 volt
@@ARUNKUMAR-nl2nb ha..wo jayada din nai chalane se moisture aa jata hai..waise contactor ka price jyda bol raha hai..
@@PEARLENGINEERING1 timer m kya chk kare sir??
Sir jo aap star Delta bataaya hai sir husme floot swich kaise connection karte hai batahiye sir
Start push button ke bad float switch ka nc series me le lo..motor band karne ke lie..high level
Delta light blinking why... Not starting moter but when open the board and manually press both start and delta soket , moter starts... Why
Dnt understand, tell me which contactor is not operating star,delta or main..
@@PEARLENGINEERING1 star
@@bunnysingh2321 check timer nc point also delta nc point
thanks bhai
Delta manual starter se smoke nikalta hai bai jab motor on krte hai
Dekho koi loose contacts ho raha hoga..ya kuch short ho raha hoga..
Sir mera man chalu hota ster chalu nehi hota kiya problem please thora bataye
Star chalu nai ho raha hai ,,to sabse pahle delta ka nc point check karo,,aur uske alawa timer ka nc v check karo..
Sir star mai moter chal raha hai lekin jab delta main ata hai to moter band ho raha hai kya kare plese salutations batao
Motor connection hata ke delta contactor ka output voltage dekho
Main contactor me 220volt coil kaise connect kare
A1 aur A2 ,220v coil ka supply hai
सर हाम को ऐक बत सिकाए मोटर स्टार से डेल्टा मा जातै बन्द हुजाता क्यू
Star ka nc ka problem hoga,ya timer ka no ka ,delta ka contactor lagta hai ya nai pahle ye dekho.
Wah sir
Sir kabhi agar start push button on Karo to chalu hota he lekin dubara band karke chalu Karo to nahi hota he Khali control ke upar on off hota he lekin motor start nahi ho rahi he to Kya karna chahiye
Dubara of karke on karne pe..contactor on ho raha hai ya nai..aur kaun sa contactor on ho raha hai aur kaun nai..ye batao
Hlo sir
Mera stater mai main and star on ho rahe hai. But Delta on nahi hon ra hai sir
Please help me sir
Check timer NO output,and also check star no connection
Bhaii Mera c&s anmol starter autoswitch work nhi kr rha..
Please meri help krdo.. mujhse call pr baat krloo
Call me 7600382705
Wow nyc knowledge
Puch button on krte hi Motar on nai hota kuj der bad hota kya problm a
Motor star me on nai ho raha hai...
@@PEARLENGINEERING1 star delta connetar on hota
@@patandhrp825 pahle star aur main contactor on hoga
Fir delta aur main contactor on hoga
Relay ko kitne me set krenge
Jitna motor ka full load amps hai uska 125%
Sir wo 3phage sumursable pump
सर जी मेरा मोटर स्टार में स्टार्ट हो जाने के बाद में जैसे ही डेल्टा में जाता है ट्रिप हो जाती है तीन-चार बार ट्रिप हो जाने के बाद में स्टार्ट किए तो स्टार्ट होता है इसमें क्या फॉल्ट है सर
Agar relay trip ho raha hai to..check motor ampere, aur agar motor ampere thik hai to relay ki ampere setting badha do thora..
Mera bhi same problem hai sar motor chalu hone ke Khushi can khudibandh rahata hai aur kuchh nahin hota fir se chalu karta hun fir se chalu hota ha
Star to delta not working....where might be the issue
Star nc point,timer no point check
Sir Ek sath man and ster chalu nehi hota ster contecter hold nehi hota
Control wiring check karo
Sir ji start karte hi 3 no block ek sath on ho raha he
3 no block matalb 3 no contactor ek sath on ho raha hai,,to fir timer ka no nc ho raha hai..pahle hi..
ACB ka fholt ho jaye to ACB ko kaise chalu kare
Vi panel all prablam batao
Mare panel se start par chalta hai or delta par nahi chalta 200 amp leta hai or slow chalta hai
Contact me on watsapp 7600382705
स्टार में मोटर चालू हो रही है लेकिन डेल्टा में जाने के बाद चालू नहीं हो रही है please solve
Delta ka contactor on ho raha hai ya nai,agr ho raha hai to check 3 phase power output from delta,
Mera bhi same problem hai motor chalne ki Khushi can't ward khud band Ho jaati hai kya Karen please bataiye
Jo ON indication ke liye wire lete hai wal shot ho sakta hsi hai
Ye mere sath huaa tha
sir starter on ho jata hai per band nahin hota hai
Check stop push button nc element.
Hamara started ma delta nahi banta ha
Check timer no,and star contactor nc
Sar same problem hai chalu nahin ho
Detail me batao
Press switch supply not coming problem
Check overload relay nc ..and also check control mcb,and also check if any external limit switch or sensor or interlocking
बाहर जो पैनल से बाहर मोटर के पास एन ओ एन सी डब्बी
👌
Hello sir mera bar bar reset karna parta ha 1ghant me motar band ho ja raha ha
Overload Relay trip ho raha hai to..check load on motor..ho sakta hai..1 ghnate me load bahut badh jata hoga..ya motor overheat ho raha hoga..
Bhai delta on hote ye noice kiska hora hai itna zyada
May be delta contactor ka hoga
@@PEARLENGINEERING1 then there should not presense noice in contactor it is also considered as a fault .
If there are dust in contactor..it may creat sound,,clean it,check input output voltage..if that is ok.. contactor is good
वहां पर सप्लाई ना जाए तो क्या करें
Uske lie..overload relay check karo kahi wo trip to nai ho gaya hai,nai to control mcb ya fuse jo v laga hai usko dekho,kahi wo to trip nai hua hai..
Sir please explain wiring as per diagram
Watch these videos
th-cam.com/video/J0Re3-fBWDc/w-d-xo.html
th-cam.com/video/bILIAWucU3E/w-d-xo.html
जो अपना पुश बटन है
Star me chlta he delta me jata nhi
Check timer NO output,usme se phase bahar aa raha hai ya nai,aur iske alawa star ka nc point v check karo..ye dono sahi hone chaiye..
Delta hote,hi folt karna
Star ka nc aur timer ka no check karo,ya motor ka ampere check karo.sayad relay trip ho raha ho
Aapka namber chahiy sir😊
.
apka number chaahiye sir
Sir aap ka number send kar sakte
Very good
Very nice 👍👍👍
Thanks sir