What is a Digital Valve Controller?

แชร์
ฝัง
  • เผยแพร่เมื่อ 22 ธ.ค. 2024

ความคิดเห็น • 27

  • @josemanuelalogoadjomo7863
    @josemanuelalogoadjomo7863 8 หลายเดือนก่อน +1

    wonderful video, just wondering whether there is a complete course on positioners offered by EMERSON and if there's
    who can I apply to??

  • @kokinkokecruz4476
    @kokinkokecruz4476 5 ปีที่แล้ว +2

    You are so good explaining

  • @shashankgamanagatti965
    @shashankgamanagatti965 ปีที่แล้ว

    It's a great enhancement of IoT connectivity to valve sector 👏.

  • @maurosotelo5509
    @maurosotelo5509 5 หลายเดือนก่อน

    Hola señor como esta? La verdad que es una excelnte explicacion!! Disculpe la molestia hay algun curso para hacer de valvulas posicionadores me podria dar infornacion xfavor entre a la pagina donde dise curso pero no me deja entrar

  • @Practical.instrumentation
    @Practical.instrumentation 11 หลายเดือนก่อน

    I'm facing issue with this type of positioner
    After calibration out put from positioner is not stable
    Valve begin hunting
    No solution is available

  • @joseluisjarana
    @joseluisjarana 3 ปีที่แล้ว

    Tengo un problema a la hora de autocalibrar que en los porcentajes no son estables,oscila el posicionador.La alimentación correcta y todo correcto,como lo corrijo.

  • @mohammadsalah5482
    @mohammadsalah5482 2 ปีที่แล้ว

    Please make video of relay I/P

  • @85giby
    @85giby 5 ปีที่แล้ว

    One of our dvc6200 f in LOcal override mode..how can I change to Cascade mode?

    • @FisherControlValve
      @FisherControlValve  5 ปีที่แล้ว

      Hello, Please reach out to your Emerson sales contact on this topic. If you need help finding them please use: www.emerson.com/en-us/contact-us

  • @145236ish
    @145236ish 4 ปีที่แล้ว

    Hello,
    Can you please explain, if a Double Type relay will work with a single acting actuator. Are there any settings?

    • @FisherControlValve
      @FisherControlValve  4 ปีที่แล้ว +2

      Relay A may be used with both Double Acting and Single Acting DVC6200 digital valve controllers. When using relay A as single acting there is an adjustment wheel in the relay that must be set by using a screwdriver. Rotate the wheel adjustment in the upward direction or negative adjustment indicated by the sticker on the front of the relay until the adjustment stops. This will set the Relay up to only operate using output A from the device. More information can be found in the DVC6200 instruction manual www.emerson.com/documents/automation/instruction-manual-fieldvue-dvc6200-hw2-digital-valve-controller-en-123052.pdf

  • @syedaslam2856
    @syedaslam2856 6 ปีที่แล้ว

    hi would some one clear my doubt as this DVC is a two wire controller how does the feed back of valve position to DCS and input from DCS works

    • @ramavelbala1
      @ramavelbala1 6 ปีที่แล้ว +1

      Feedback of the valve position to DCS is through communication protocol used. Either HART or Fieldbus communication. One is 2 way superimposed 4-20mA signal and latter is 2 way digital signal .

  • @shaguftasayyed8019
    @shaguftasayyed8019 4 ปีที่แล้ว

    Asl
    How one pair wire work analog output and analog output
    Question is if I am in junction box measure mA of valve if dcs send 8 mA and feedback is 12 mA what my Multimeter will show in JB
    I am confused how one pair wire work both AO and AI

    • @MilitantPrepping
      @MilitantPrepping 4 ปีที่แล้ว

      I believe your Multimeter will show the 8mA signal from DCS, you will need something like a 475 to see both input and feedback

    • @MilitantPrepping
      @MilitantPrepping 4 ปีที่แล้ว

      Hart is able to transmit input and feedback signal at the same time using slightly differing sine waves, it's also able to send ditigal hart signal along with analog signal at the same time over a single pair. Bell 202 + Analog signal

  • @randomfellow6245
    @randomfellow6245 3 ปีที่แล้ว

    does a DVC adjust pressure output to cover for actuator springs that are too stiff? for instance a 2" 10-30 that is only getting 1.5" 10-30, will the DVC ensure it puts 40lbs to the actuator to get that extra 1/2" of travel?

    • @FisherControlValve
      @FisherControlValve  3 ปีที่แล้ว

      The DVC will continue to adjust output pressure until one of the following takes place:
      - Travel measured by feedback matches the desired set point
      - Maximum supply pressure is reached or
      - Zero output pressure is reached
      So it will compensate, but that will be limited by supply. However, if you find yourself tempted to continue to up the supply pressure we'd suggest reaching out to your local Emerson sales office to troubleshoot the root cause.

  • @kokinkokecruz4476
    @kokinkokecruz4476 5 ปีที่แล้ว

    Excellent

  • @brunomoralesflorentino9681
    @brunomoralesflorentino9681 2 ปีที่แล้ว +1

    Este posicionador si se daña la bobina tienes que cambiar todo el posicionador contrario al 0osionador análogo

  • @israrullah4779
    @israrullah4779 4 ปีที่แล้ว

    Sir how to join your class room, please assist, i am very much fond to seek sir plz any whatsapp or other link that i may avail

    • @FisherControlValve
      @FisherControlValve  4 ปีที่แล้ว

      Hello Israr, Please visit www.emerson.com/en-us/automation/services-consulting/educational-services to help find training in your area.

  • @shunty8254
    @shunty8254 6 ปีที่แล้ว

    Dear sir pls all video translate in Hindi..

  • @belaybekele2625
    @belaybekele2625 2 ปีที่แล้ว

    wow amanjing

  • @akramzmin4721
    @akramzmin4721 6 ปีที่แล้ว

    Pls translate in hindi

    • @hfcarwash
      @hfcarwash 2 ปีที่แล้ว

      Hdufisncipsjhdksjdjhjsjd