Electrocutati in piscina.Diferentialul functioneaza fara priza de pamant.[citeste descriere]

แชร์
ฝัง
  • เผยแพร่เมื่อ 25 มิ.ย. 2024
  • Electrocutati in piscina.Diferentialul functioneaza fara priza de pamant.ASTA NU INSEAMNA CA NU TREBUIE SA FACEM PRIZA DE PAMANT,PENTRU CA ESTE OBLIGATORIE, DAR EXISTA LOCURI [EXEMPLE : APARTAMENTE VECHI SAU CASE CARE AU DOAR DOUA CONDUCTOARE DE LA FURNIZOR SI DE LA TABLOU IN CAMP PLEACA DOAR DOUA CONDUCTOARE ] CARE NU AU ASA CEVA SI NICI NU SE POATE FACE PRIZA DE PAMANT FARA ACORDUL TUTUROR LOCATARILOR SI FARA SCHIMBAREA TOTALA A COLOANELOR DE PE CASA SCARII.
    CEI CARE STAU LA CURTE NU AU NICI O SCUZA SA NU ISI FACA MAI ALES CA IN 2024 AVEM SISTEMUL DE ELECTROZI BP SI DECI PUTEM FACE PRIZA DE PAMANT FOARTE USOR.
    IN SITUATIILE EXPUSE MAI SUS,UNDE NU AVEM PRIZA DE PAMANT,PUNEM ,FARA COMPROMISURI SI FARA URMA DE INDOIALA,RCBO PE TOATE CIRCUITELE,NU EXISTA ALTA SOLUTIE.
    NU INCERCATI ASTA ACASA.
    Atentie:interventia la instalatia electrica se face de catre personal calificat.
    Filmele de pe acest canal nu sunt tutoriale asa ca va rog sa nu va bagati manute in instalatia electrica.Filmuletele de pe acest canal sunt necesare celor care vor sa invete electrica,celor care vor sa vada cum se aplica teoria din scoala direct pe teren.Le putem considera adjuvante pentru cei care invata electrica in momentul de fata ,dar in nici un caz nu reprezinta tutoriale pentru ca electrica nu se face in regim DIY.
    Alătură-te acestui canal pentru a primi acces la beneficii:
    / @proiectediversediy
    AFDD ieftin
    elektrosystem.ro/KZS-AFDD-3M2...
    elektrosystem.ro/KZS-AFDD-3M2...
    elektrosystem.ro/brida-de-cup...
    elektrosystem.ro/cabluri-cond...
    Pentru Cartea Inginerie Electrica ,Tabele,Standarde,Formule
    elektrosystem.ro/
    elektrosystem.ro/Carti_pentru...
    Ne gasiti pe TikTok la
    tiktok.com/@proiectediversediy
    Grupul Nostru de Facebook
    / electricieniromania
    Email:
    Proiectediversediy@gmail.com
    Sustine canalul si activitatile noastre umanitare cu un abonament de 3.99 ron pe luna.
    Foloseste butonul e Join sau Alatura-te.
    / @proiectediversediy
    Membrii platitori ai canalului beneficiaza de discount la diversi furnizori.
    Pentru constultanta aveti 2 optiuni la butonul de JOIN.Atentie consultanta se plateste doar odata,adica doar un abonament lunar.
    shop.electro-instalatii.eu/
    DE UNDE POT COMANDA disjunctoare CURBA B si DIFERENTIALE TIP A B B+ si F ?
    Inafara de ETI aveti mai jos inca 2 surse.Livrarea se face din stoc in max 48 de ore .
    comenzi@electro-instalatii.eu
    shop.electro-instalatii.eu/ pentru toata tara.
    sau pentru Bucuresti
    mirela.electricteam@gmail.com
    etd-group.ro/
    Aici gasit HAGER, ABB, Doepke, Legrand, Kaiser,Eltropa,Phoenix Contact,Wago,Eltako,Siemens,Finder,Ideal,Egutek,Jung,Gira,Cell Pack, etc
    Protectii AFDD
    Pentru Electrician Non Stop Bucuresti
    interventii-electrice-bucures...
    Electrician Autorizat Ilfov
    Sigurante curba B
    p+n - www.materialeelectrice.ro/faz...
    1p - www.materialeelectrice.ro/mon...
    2P- www.materialeelectrice.ro/bip...
    3P- www.materialeelectrice.ro/tri... ?share=61391
    4P - www.materialeelectrice.ro/tet...
    Diferentiale bipolare - www.materialeelectrice.ro/bip...
    Diferentiale tetra www.materialeelectrice.ro/tet...

ความคิดเห็น • 270

  • @Wardrunaas
    @Wardrunaas 8 วันที่ผ่านมา

    Foarte frumos explicat, mulțumim!

  • @shumy-wi2nx
    @shumy-wi2nx 17 วันที่ผ่านมา +9

    27,5 Ohm pe priza de impamantare pe Belgia, legal. Binenteles, cu Diferential 30 mA, mai des curba C, mai rar B. Cu explicatiile astea mereu detaliate, zici ca esti ca tata in persoana, si el, d-zeu sa-l ierte, la fel le explica clientilor, detaliat ca sa priceapa, (si el tot electrician, dar si electronist era). De la el am invatat meserie de electrica, cu mult inainte de a face scoala de electricieni in Ro. La 10 ani modificam lampi duble fluorescente sa se aprinda separat fiecare tub cu comutator pe perete. El le aducea, eu le modificam si el le revindea la altii. Apoi reparam televizoare atestat de el mereu cand eram mic, apoi singur in timp. Sau bobinari de rotoare, statoare, rasnite de cafea, frigidere, masini de spalat, etc. Si ma mandresc ca cunosc meseria asta frumoasa si banoasa si de viitor. Felicitari, chiar daca ai dusmani care nu te aproba, tu mergi mai departe si arata-le!! Am adus din Belgia la casa noua din Slanic, toata din lemn, pe care am inceput-o anul trecut, iar in prezent e la rosu cum se spune, cabluri de net, de KNX, de electric, originale belgiene, era un electrician pe acolo si cand i le-am aratat cu ce vreau sa fac instalatia electrica, si tarusi si platbanda si diverse a zis:"ce-s astea frate, avioane? pai noi nici n-am vazut pana acum DEHN descarcator de tensiune rosu, ce ai tu aici aduse de afara", dar la inceput de discutie zice: "ce-ti trebuie tie Cat 8.2 pentru internet sau CEBEC 5 x 25mm" cupru plin si litat pentru tronson de alimentare general, ca noi iti aducem maxim 16mm" aluminium", pai ce faci, treci peste noi??" Da' care-i treaba lui nene, eu imi alimentez casa si cu 5 x 150mm" daca vreau de la BMPT, chiar daca el imi aduce la nas 10mm". Poate eu vreau strunguri si hale cu freze si raboteze sa fac in viitor, nu? Vreau sa tina. Iar cablurile au maxim 5 culori, respectiv maro/negru/gri/bleu/verde-galben. Nu inshpe culori ca-n tablourile electrice din Ro. Sa vezi hate ce-mi iau acum de la unii :)))))))

    • @Proiectediversediy
      @Proiectediversediy  17 วันที่ผ่านมา +2

      Amintiri omule.
      La 7 ani ma jucam cu releele termice de la lift.

    • @Proiectediversediy
      @Proiectediversediy  17 วันที่ผ่านมา +2

      Nu iti iei hate pentru ca ai dreptate.

    • @SebastianAcsinte-ck2xd
      @SebastianAcsinte-ck2xd 9 วันที่ผ่านมา

      nu iti iei hate boss si eu tot asa am fost de la 6 ani ma luat tata pe santier iar acum la 15 ani fac niste instalatii pe care nici unul la 30 de ani .

  • @mirelghe.7387
    @mirelghe.7387 17 วันที่ผ่านมา +9

    De sigur este foarte, bine sa fie pus diferențial,dar citi înțeleg că acel diferențial le salvează viața,majoritatea se uita că este scump ,dar prețul vieții nu îl ia în calcul. Foarte bine explicat și demonstrat ,multă sănătate.

    • @electronvasile7498
      @electronvasile7498 17 วันที่ผ่านมา +1

      Nu prea inteleg ei electricienii ce face acel diferentila ,ce pretentii mai avem l;a clienti?

    • @Proiectediversediy
      @Proiectediversediy  17 วันที่ผ่านมา +8

      O sa fac multe video pe tema asta pana intelege toata lumea.

    • @ionutdumitru1387
      @ionutdumitru1387 14 วันที่ผ่านมา

      @@Proiectediversediy din pacate pentru multe persoane va fi prea tarziu

  • @gabi-remustupu2291
    @gabi-remustupu2291 9 วันที่ผ่านมา +1

    Eu locuiesc la țară, sincer să-ți spun când le explic de protecția diferențială că trebuie bre omule acolo in tablou! Îmi spun că e scumpă!😂 Mai întâlnesc tip Ac, mulțumim pt film ❤

    • @Proiectediversediy
      @Proiectediversediy  9 วันที่ผ่านมา +1

      Daca atat isi pretuiesc ei viata ce le poti cere?

  • @kasandra5266
    @kasandra5266 17 วันที่ผ่านมา +6

    Imi place aranjamentul pe care l-ai facut pe placa aceea de lemn.
    Si explicatiile sunt sublime.Bravo
    Keep up de good work.

  • @drdannegoita
    @drdannegoita 16 วันที่ผ่านมา +1

    De abia aștept alea 2 coli A4. 👍👍👍👍👍

  • @ionstan6486
    @ionstan6486 14 วันที่ผ่านมา

    Mulțumim pt acest video foarte clar!

  • @valipustiu3144
    @valipustiu3144 13 วันที่ผ่านมา

    Nu am mai întrat de mult pe canal, ai rămas același, bravo și mulțumim pentru efortul depus!

  • @electronvasile7498
    @electronvasile7498 17 วันที่ผ่านมา +5

    Foarte bune explicatiile ca sa stii toata lumea ca fara diferentila e nasoala treaba.

  • @cristianmihai1086
    @cristianmihai1086 17 วันที่ผ่านมา +1

    Tot respectul dle Stefan !!! Va multumesc !!!

  • @bunsoft2
    @bunsoft2 17 วันที่ผ่านมา +2

    Mersi pentru video. Conținut util.

    • @Proiectediversediy
      @Proiectediversediy  17 วันที่ผ่านมา +2

      Eu multumesc pentru ca te uiti la mine.

  • @oas5215
    @oas5215 17 วันที่ผ่านมา +1

    explicatie foarte buna.
    va multumesc domnule Stefan.

  • @afctin
    @afctin 17 วันที่ผ่านมา +2

    Buna seara, Multumesc mult pentru filmuleti si informatii, Cu stima, Antonio❤

  • @Flyonwaterslow
    @Flyonwaterslow 17 วันที่ผ่านมา +1

    Foarte educativ, felicitari!

    • @Proiectediversediy
      @Proiectediversediy  17 วันที่ผ่านมา

      Multumesc pentru ca te uiti la mine.Apreciez.

  • @rauliove5948
    @rauliove5948 16 วันที่ผ่านมา +1

    Dumnezeu să te binecuvînteze , să-ți de-a pe măsura inimi tale .Mulțumim frumos pt sfaturi,etc🥰🥰🥰

    • @Proiectediversediy
      @Proiectediversediy  16 วันที่ผ่านมา +1

      😍😍😍😍😍😍😍😍😍😍😍😍😍😍😍😍😍😍😍😍😍😍😍😍😘😘😘😘😘😘😘😘😘😘😘😘😘😘😘😘😘😘😘😘😘😘😘😘😘😘😘😘

  • @angelica1337
    @angelica1337 17 วันที่ผ่านมา +1

    Bravo pentru video,super explicatia.
    Parere personala:mult mai important diferentialul decat priza de pamant.

  • @Razvan_Udrea
    @Razvan_Udrea 17 วันที่ผ่านมา +1

    Multumim de video!

  • @liviuprecup4447
    @liviuprecup4447 16 วันที่ผ่านมา +1

    Mulțumim. Sănătate.....

  • @dumitrustanca3293
    @dumitrustanca3293 16 วันที่ผ่านมา +1

    Corect .Felicitari .

  • @constantinciudin6003
    @constantinciudin6003 17 วันที่ผ่านมา +2

    Mulțumesc pentru demo,apreciez dedicarea pentru meserie in scopul imbunatatirii sigurantei in exploatare a instalațiilor electrice ! Este foarte pacat ca inca in secol 21 zugravii efecueaza instalatii electrice !👍

    • @Proiectediversediy
      @Proiectediversediy  17 วันที่ผ่านมา +1

      Multumesc pentru aprecieri.
      Zugravii nu ar trebui lasati sa faca instalatii.Sau daca fac la sfarsit sa nu li se dea la clienti drumul la curent.

  • @ovidiu1978
    @ovidiu1978 17 วันที่ผ่านมา +1

    Super ok. Mulțumim!

  • @cristianciumas3217
    @cristianciumas3217 16 วันที่ผ่านมา +1

    Foarte bine demonstrat, despre necesitatea montării diferențialelor! Chiar dacă se revine asupra acestui aspect, rămâne esențial și prioritar pentru viața omului! Respect!

    • @Proiectediversediy
      @Proiectediversediy  16 วันที่ผ่านมา +1

      Incercam sa sensibilizam electricienii dar si clientii ,sa ii facem sa constientizeze ca nu e ok fara ca sa nu mai zic ca e ilegal.

    • @cristianciumas3217
      @cristianciumas3217 16 วันที่ผ่านมา +1

      @@Proiectediversediy Chiar dacă e o muncă de convingere imensă, continuați pe aceeași linie, deoarece meseriașii tineri au altă mentalitate și până la urmă toți vor înțelege importanța acestor dispozitive. Asta ține de educație și de bun simț până la urmă! Spor la treabă!

    • @Proiectediversediy
      @Proiectediversediy  16 วันที่ผ่านมา +1

      Speram.

  • @DjGrooverGSMstudio
    @DjGrooverGSMstudio 16 วันที่ผ่านมา +1

    FOARTE FRUMOS! BRAVO! NICI EU NU ȘTIAM PANA ACUM 6 LUNI CA PE SE PUNE LA LUMINĂ.

    • @Proiectediversediy
      @Proiectediversediy  16 วันที่ผ่านมา +1

      E uite ca ai aflat.

    • @pacopaco1307
      @pacopaco1307 14 วันที่ผ่านมา

      Salut! Ce înseamnă PE la lumină? Mulțumesc!

  • @catalin62
    @catalin62 16 วันที่ผ่านมา +1

    "Nu incercati asta acasa" :) De acord, moral, legal. Dar eu i-as lasa pe cei care spun ca n-ai nevoie de diferential ca 'vrea sa-ti fure banii" sa testeze fara RCD.

    • @Proiectediversediy
      @Proiectediversediy  16 วันที่ผ่านมา

      A mai scris cineva acelasi comentariu ca al tau.Adica crezi ca selectia naturala ne-ar ajuta?

  • @remusbudea855
    @remusbudea855 17 วันที่ผ่านมา +1

    Multumim Stefan pentru toate informatiile,nu asculta hate-urile,esti cel mai profi electrician!!! Felicitari,stima si respect!!!

    • @Proiectediversediy
      @Proiectediversediy  17 วันที่ผ่านมา +1

      Multumesc pentru aprecieri dar mai am mult pana la profi,invatam non-stop.
      Mersi.

  • @bogdanchelmu6797
    @bogdanchelmu6797 12 วันที่ผ่านมา +1

    Mare om.

  • @sitonya1482
    @sitonya1482 17 วันที่ผ่านมา +1

    Foarte bune explicatiile si completarile de la video trecut.

  • @ioanhas-so9ux
    @ioanhas-so9ux 17 วันที่ผ่านมา +1

    Bravo Foarte bine punctat

  • @ghezuroiuenel7654
    @ghezuroiuenel7654 17 วันที่ผ่านมา +2

    Bravo pentru experiment si pentru explicatii.Diferentialele fac diferenta.
    Trebuie si priza de pamant dar fara diferential e tot un rahat.

    • @Proiectediversediy
      @Proiectediversediy  17 วันที่ผ่านมา +3

      Ambele sunt obligatorii si foarte importante.

  • @culnai
    @culnai 16 วันที่ผ่านมา +1

    Multumim!

  • @gheorghenarita2248
    @gheorghenarita2248 16 วันที่ผ่านมา

    Bine de știut!

  • @ghitza85
    @ghitza85 16 วันที่ผ่านมา +1

    Până să dau de tine nici nu știam ce e ăla diferențial, aveam fuzibile cu liță, până am aflat din clipurile tale că nu e ok și am cumpărat fuzibile nu le-am reparat, a venit Enel-ul a scos contorul la poartă și in loc de fuzibile a pus și pe lumină și pe priză c25, nu am fost acasă din păcate, am cumpărat eu
    B16 și B10 și am înlocuit c25, după un timp am adăugat un diferențial pe general, am învățat ceva de la tine, folosesc și pini la lițat am dat 50 de lei pe un set de la lidl cu clește cu tot, nu sunt electrician dar sunt mai în siguranță mulțumită ție, mulțumesc Stefan

    • @Proiectediversediy
      @Proiectediversediy  16 วันที่ผ่านมา +2

      Ma bucur ca ai pus diferential ,sa il si testezi lunar te rog.

  • @nicolaetomoiaga8098
    @nicolaetomoiaga8098 17 วันที่ผ่านมา +1

    Domnule Ștefan. Te felicit pentru faptul că ai dovedit în practică ceva ce nu mulți electricieni sau specialiști în domeniu știu: un diferențial NU are nevoie de împământare pentru a funcționa în cazul scurgerii la pământ a unui curent rezidual MAI MARE de 30 mA. Ceea ce, atât Ion, Petre, Gheorghe cât și Vasile trebuie să înțeleagă este că, se face legătura la împământare a carcasei metalice a mașinii de spălat vase, a celei de haine, a betonerei, a unui cuptor cu microunde etc. fiindcă în cazul unui defect de izolație a fazei (fazelor) care alimentează acel aparat, fie va decupla diferențialul, se va topi siguranța, sau va decupla siguranța automată de pe respectivul circuit. Și prin inimuța oimului nu se va scurge niciodată curent electric. Teoria ca teoria, însă praftica -bătu-ar vina să o bată, pe mulți îi omoară.
    Recomand cu toată căldura și responsabilitatea TUTUROR celor care au aparat electric de tip fierăstrău pentru tăierea gardului viu (verde) din grădină, pe cablul prelungitor de alimentare al aparatului să monteze un diferențial SPECIAL care se montează direct pe cablu și acesta va decupla la un curent rezidual de 10 mA. În acest fel omul va putea să lucreze în siguranță deplină chiar dacă este o găgăuță proastă care ajunge să taie cablul electric în timpul tăierii gardului viu. Un astfel de diferențial poate să fie cumpărat pe internet de către cei interesați. Costă în jur de 10-15 Euroi.
    Domnule Ștefan, am dirijat și eu electronii prin sârme timp de vreo 50 de anișori și nu îmi este rușine să întreb și pe alți colegi de breaslă de ceva ce pe mine mă arde năpraznic la buza interesului: știți cumva dacă există în lumea asta largă și nătângă ceva în genul diferențialului montat la tablourile electrice de curent alternativ (mono sau tri) dar care, ATENȚIE, să poată să fie montat cu succes pe ieșirea monofazată sau pe cea trifazată de la un INVERTOR ?!?! Pericolul major pentru om este atunci când, în mod accidental, el ar ajunge să atingă în acelaș timp ambele ieșiri ale invertorului în cazul în care ieșirea este de 230 V AC. În acest fel corpul uman se transformă într-un simplu consumator electric. Mulțumesc anticipat. Numai bine.

    • @Proiectediversediy
      @Proiectediversediy  16 วันที่ผ่านมา +2

      Multumesc pentru comentariu.
      Si ordinul ANRE legat de PV-uri si I-7 ne spune sa punem RCD de 100mA pe partea de AC a fiecarui invertor.

    • @Lu-channist
      @Lu-channist 13 วันที่ผ่านมา

      Urmariti acest video-clip. Are toate explicatiile necesare pentru montarea tablourilor electrice care se utilizeaza la un sistem fotovoltaic. th-cam.com/video/ssUjhJ6JLFk/w-d-xo.html

  • @dracometaldetectors7091
    @dracometaldetectors7091 17 วันที่ผ่านมา +1

    Bravo! Sa te auda cat mai multi!

  • @fokozuynen2048
    @fokozuynen2048 17 วันที่ผ่านมา +3

    Man am facut scoala de electrotehnica dar din cauza ca nu am continuat sa si profesez la ora actuala decat sa fac la cineva vreo lucrare si apoi sa sa fie buleala din cauza ca am uitat ceva mai bine nu fac. Apoi daca ar fi sa fac nicidecum nu as face ca vezi domne nu isi permite omu si zic stai sa ii fac fara diferential sa fie mai ieftin sau sa am eu lucrare ca i'am cerut mai ieftin. Video asta mi-a placut intru cat lucrez ca Instalator Sanitare :) si lucrez la subsoluri, precum toate subsolurile am mereu discutii cu colegii despre protectia noastra daca ne cade plita de ppr sau altceva pe jos . Fiind umed sau chiar multa apa daca o sa ne bufneasca rasu, si uite ca e mai bine sa avem cutia noastra de protectie dupa ce ne conectam la un tablou de pe vremea lui Ceausescu unde nu exista decat sigurante ceramice si impamantare.

    • @corona1372
      @corona1372 17 วันที่ผ่านมา +1

      Daca ai tablou sau prelungitor cu tine cu diferential ai tot respetul meu.

    • @Proiectediversediy
      @Proiectediversediy  17 วันที่ผ่านมา +1

      Omule trebuie sa iti protejezi pielea ca nu stii la ce pericol te expui pe teren mai ales ca voi munciti cu apa.
      Respect.
      @fokozuynen2048

    • @Proiectediversediy
      @Proiectediversediy  17 วันที่ผ่านมา +1

      @@corona1372 Corect.Mare respect.

  • @KsSwordKing
    @KsSwordKing 17 วันที่ผ่านมา +2

    Faina treaba pe intelesul tuturor. Mai ales cum zici tu si cum nu au multi impamantare daca rcd-ul e scump apai ce dreq sa mai zicem de rcbo . Ca aia nu inteleg oamenii ai rccb varianta eftin esti salvat ai rcbo pe fiecare si mai bine apai daca mai ai si impamantare esti pe.abonament premium 😅. Hai sa fi sanatos Stefane te-am pupat.

    • @Proiectediversediy
      @Proiectediversediy  17 วันที่ผ่านมา

      Indiferent cu e sa aiba RCD pe toata instalatia si PE bineinteles.

  • @mariangradila6976
    @mariangradila6976 17 วันที่ผ่านมา +1

    Felicitări

  • @baciu6272
    @baciu6272 17 วันที่ผ่านมา +2

    Hai cu algoritmul 😂😂😂😂😂😂😂😂😂😂😂😂😂😂😂😂 acuma fara misto dar video asta si cel din urma trebuie vazut de catre toti posesorii de tablouri electrice si de creier ,bineinteles.
    Multumim pentru lamuriri,este foarte important sa stim ce face priza de pamant si ce face impamantarea.

    • @DozatorulCornelius-rt6yy
      @DozatorulCornelius-rt6yy 17 วันที่ผ่านมา

      👍👍👍👍👍👍👍👍

    • @Proiectediversediy
      @Proiectediversediy  17 วันที่ผ่านมา +3

      Algoritmul lui youtube e setat pe manele ,incultura si taraturi cu botox in buze sau ce cacat le mai baga in buzele alea de rata.

  • @corinairimia5218
    @corinairimia5218 17 วันที่ผ่านมา +1

    Te salut si te felicit mult respect

  • @RileyVenus
    @RileyVenus 17 วันที่ผ่านมา +1

    Bravo Stefan! Cei ce au ochi sa vada si urechi sa auda vor intelege ce zici. Ar trebui sa fi rasplatit pentru informatiile acestea pe care le oferi dupa ore de studiu, dar ce sa zic...multe aprecieri pentru rabdarea de a explica si ca incerci sa schimbi lucrurile in mai bine. Impreuna cu alti electricieni care studiaza se va aduce mai mult awareness asupra acestui subiect

    • @corona1372
      @corona1372 17 วันที่ผ่านมา +2

      Pai inafara de hate si injuraturi nu prea stie romanul ce sa faca.

    • @Proiectediversediy
      @Proiectediversediy  17 วันที่ผ่านมา +1

      @RileyVenus Asta e si scopul sa facem cat mai bine si cat mai safe.

  • @SlowBearIndustries
    @SlowBearIndustries 17 วันที่ผ่านมา +1

    O sa ajunga la multi beneficiari acest video

  • @gonedoneggonedoneg9863
    @gonedoneggonedoneg9863 17 วันที่ผ่านมา +1

    😮 mulțumesc frumos pt timpul acordat și efort depus pt noi.....acenarii sunt milioane ca fara viagra sa ramai cu 🥕 in sus

  • @DjGrooverGSMstudio
    @DjGrooverGSMstudio 16 วันที่ผ่านมา +2

    SIGURANȚĂ SIGURANȚĂ SIGURANȚĂ SIGURANȚĂ SIGURANȚĂ SIGURANȚĂ / LASĂ SAFE ÎN PACE!!!

  • @alexandrublaga8487
    @alexandrublaga8487 16 วันที่ผ่านมา +1

    Un video foarte explicativ. Bravo tie pentru rabdarea de care dai dovada. Te-as ruga sa-mi explici de ce nu functioneaza diferentialele puse in cascada. Ai promis intr-un video ca explici. Multumesc anticipat.

    • @Proiectediversediy
      @Proiectediversediy  16 วันที่ผ่านมา +1

      Man functioneaza ,nu a zis nimeni canu functioneaza dar se suprapun unul peste altele si nu este ok,pierdem selectivitatea.Daca pierdem selectivitata putem pierde circuite care pot fi vitale si pe care nu trebuie sa le oprin din cauza unui defect care a aparut in aval print-un alt diferential.

    • @alexandrublaga8487
      @alexandrublaga8487 16 วันที่ผ่านมา +2

      @@Proiectediversediy Ok am inteles acum. Te-am intrebat pt ca eu am pus un Rcbo eti cel de un singur modul la 10miliamperi si cand mi s-a ars pompa din fantana sarea doar el fara sa afecteze RCCB de pe general. Asta la un tablou trifazic, unde Rcbo-ul alimenta o pompa de piscina si ocazional o pompa submersibila. Iti multumesc pt raspuns.

    • @alexandrublaga8487
      @alexandrublaga8487 16 วันที่ผ่านมา +1

      Rcbo-ul sarea pt curentul diferential, se oprea parghia la mijloc, dupa ce am scos pompa, am vazut ca crapase carcasa si probabil intra apa in ea.

    • @Proiectediversediy
      @Proiectediversediy  16 วันที่ผ่านมา +1

      Exact,cand sare rcd sa stii ca e o problema mare acolo.

    • @alexandrublaga8487
      @alexandrublaga8487 16 วันที่ผ่านมา

      @@Proiectediversediy Multumesc, mare domn. O zi faina!

  • @adriansavescu7321
    @adriansavescu7321 17 วันที่ผ่านมา +2

    👍

  • @FlorinUrzica
    @FlorinUrzica 17 วันที่ผ่านมา

    👍👍👍

  • @viorelcostache2569
    @viorelcostache2569 17 วันที่ผ่านมา +1

    A-i perfectă dreptate

    • @DozatorulCornelius-rt6yy
      @DozatorulCornelius-rt6yy 17 วันที่ผ่านมา

      Degeaba are daca "meseriasi" folosesc inca doar 2 conductori ca asa au invatat ei la stana.

    • @Proiectediversediy
      @Proiectediversediy  17 วันที่ผ่านมา

      👍

    • @Proiectediversediy
      @Proiectediversediy  17 วันที่ผ่านมา

      @@DozatorulCornelius-rt6yy La stana e curent?

  • @lumealuibanciu5022
    @lumealuibanciu5022 17 วันที่ผ่านมา +1

    Foarte bune explicatiile si multumesc pentru ele.O sa arat aceste doua video la colegi poate mai baga si ei ceva la cap.
    Am niste colegi care monteaza piscine si jacuzii si nici nu am curaj sa ma uit in acele tablouri.

    • @Proiectediversediy
      @Proiectediversediy  17 วันที่ผ่านมา +1

      E jale pe piscine si jacuzii.Ce gasim pe teren te iei cu mainile de cap.

  • @Rosumariuscostel91
    @Rosumariuscostel91 16 วันที่ผ่านมา

    Foarte bine explicat dar din păcate mulți suferă de dorelistică acută inclusiv clienții. Ca si concluzie improvizațiile=contract cu Sfântul Petru

  • @ioancovaci9794
    @ioancovaci9794 17 วันที่ผ่านมา +4

    Salut Ștefan chiar te rog sa faci acest videoclip de la BMPT până la tabloul general. Multumesc.

    • @Proiectediversediy
      @Proiectediversediy  17 วันที่ผ่านมา +2

      O sa il fac.De la BMPT la tabloul general si ce trebuie sa confina acest tablou general.

    • @paulgeorgiancaliap9828
      @paulgeorgiancaliap9828 16 วันที่ผ่านมา

      Salutare MAESTRE...ABIA AȘTEPTAM ACEST TUTORIAL...Până atunci... Multă sănătate și succes in continuare 👍 👍 👍 🙏 🙏 ​@@Proiectediversediy

  • @georgecalin2854
    @georgecalin2854 16 วันที่ผ่านมา

    Bună seara. Urmăresc de mult timp canalul, multumesc pentru informatii. Prof. Nana ce mai face?

    • @Proiectediversediy
      @Proiectediversediy  16 วันที่ผ่านมา +1

      Multumesc pentru ca te uiti la mine.
      Nana era prin Germania cand am vorbit ultima data.

  • @immarius92
    @immarius92 17 วันที่ผ่านมา +1

    ⚡⚡⚡👏👏👏

  • @shift5903
    @shift5903 16 วันที่ผ่านมา +1

    Salutare,
    Curand o sa termin facultatea de inginerie electrica si desi am invatat o gramada de lucruri , unele benefice , altele de umplutura .. sincer pe partea practica scartai sa zic asa, dar videoclipurile tale ma ajute sa inteleg anumite aspecte si sa fac legatura.
    imi place foarte mult profesionalismul de care dai dovada si cum explici totul. So, thank you .
    Daca ai avea ceva sfaturi pentru un tanar ca mine care urmeaza sa intre in acest domeniu si nu vine la bord cu experienta as fi tare recunoscator .
    Cheers!

    • @Proiectediversediy
      @Proiectediversediy  16 วันที่ผ่านมา +1

      De unde esti?

    • @shift5903
      @shift5903 16 วันที่ผ่านมา

      @@Proiectediversediy Ploiesti- prahova

    • @Proiectediversediy
      @Proiectediversediy  16 วันที่ผ่านมา +1

      Sfatul meu?
      Vorbeste cu baietii de la
      www.youtube.com/@electricteamro
      si roaga-i sa te lase sa mergi cu ei pe teren si o sa inveti cate ceva.Intre scoala si teren e mare diferenta.
      Eventual lasa-mi un numar de telefon pe mail si ne auzim.

    • @shift5903
      @shift5903 15 วันที่ผ่านมา

      @@Proiectediversediy Mulțumesc pentru sfat! O să iau legătura cu băieții de la Electric Team.
      Intre timp ti-am trimis si un email cu nr de telefon .

  • @cristipopa6855
    @cristipopa6855 15 วันที่ผ่านมา

    Salut Stefan, vreau sa- ți multumesc pentru toate informatiile oferite si totodata sa recunosc ca mi-ai deschis ochii cu privire la afdd ( vina mea ca nu am citit atent fisa ) ca sunt atat combinate cu mcb cat si cu rcbo.
    Nu am luat seama si am luat in loc de un afdd + rcbo un afdd cu disjunctor .Acum o sa pun un RCCB in fata.
    Multumesc inca odata , acum am citit atent si fisa tehnica.
    Norocosi sunt baietii care lucreaza la tine , au de la cine invata.
    Mi-ar placa sa te am de maestru !

  • @claudiuminciu
    @claudiuminciu 17 วันที่ผ่านมา +1

    Corect 300%

  • @ion.23
    @ion.23 13 วันที่ผ่านมา

    Domnul Stefan te rog recomanda.mi pt o instalație facuta prin podul casei....ce doze si cablu pot trage direct pe grinzile de lemn. Mulțumesc

  • @vasileoana3826
    @vasileoana3826 17 วันที่ผ่านมา +1

    Salutare tuturor! Stefan, cred ca un clampmetru pentru curenti de scurgere pus pe coductorul cu care simulai punerea la pamant ne-ar fi arătat de ce nu decupla diferentialul cand atingeai betonul. Multumesc din suflet pentru toate lucrurile pe care le faci din pasiune pentru aceasta meserie frumoasa!

    • @ghezuroiuenel7654
      @ghezuroiuenel7654 17 วันที่ผ่านมา

      Nu zici rau dar nu stiu cine il tinea.

    • @Proiectediversediy
      @Proiectediversediy  17 วันที่ผ่านมา +1

      Colegul de jos a zis bine :cine il tinea?🤣🤣🤣🤣🤣🤣
      Sa stii ca am avut un clampmetru cu surub pentru stativ si abea acum am aflat la ce era bun.

  • @chicabomb5933
    @chicabomb5933 7 วันที่ผ่านมา +1

    Salutare! tocmai acum lucrez la un sistem diy de incalzire al apei pentru piscina (panouri solare facute din teava pvc). acum lucrez la partea electronica (pompa+ sensori de temperatura introdusi in panouri pentru monitorizarea temperaturii). Eu folosesc o pompa pe 12v alimentata de o sursa de tensiune in comutatie. intrebarea mea este daca exista riscul de electrocutare in piscina avand in vedere ca toata electronica e amplasata intr-un container waterproof si tot ce iese din el sunt cablurile de la senzori + cablul pompei si, evident, cablul de alimentare al sursei.

    • @Proiectediversediy
      @Proiectediversediy  7 วันที่ผ่านมา

      La 12 volti nu ar fi problema dar chiama un electrician totusi.

  • @pacopaco1307
    @pacopaco1307 14 วันที่ผ่านมา

    Te rog spune ce înseamnă toate prescurtările la care faci referire! De exemplu ce este PE la lumină? Mulțumesc!

  • @mares9755
    @mares9755 16 วันที่ผ่านมา +1

    Lăsând gluma la o parte sper sa înțeleagă mulți ce înseamnă asta

  • @---gn7gw
    @---gn7gw 16 วันที่ผ่านมา +2

    Intrebare de 1000 de puncte. Dacă eu as fi in piscină si firele alimentate cad in piscină, mai decuplează diferentialul? Eu cred că nu, poate mă înșel.

    • @Proiectediversediy
      @Proiectediversediy  16 วันที่ผ่านมา +2

      Daca piscina este din plastic ,adica izolata fata de pamant,si care doar faza si nulul te pajesti elegant.
      Daca cade si PE ul in piscina,adica cablu cu 3 conductori si ai diferential scapi.Daca nu ai diferential e nasol.

  • @ciucudaniel9420
    @ciucudaniel9420 15 วันที่ผ่านมา

    Salutare.. cât costa un tablou idem cu cel din video?

  • @mares9755
    @mares9755 16 วันที่ผ่านมา

    Vai ce piscina mică 😢😢😢😢

  • @drdannegoita
    @drdannegoita 16 วันที่ผ่านมา

    Am dat deja Forward la 3 persoane și mai urmează încă vreo 300. 😀

  • @richardleon3230
    @richardleon3230 17 วันที่ผ่านมา +1

    Ăsta este mai precis de ce sa întâmplat, cine îi pune să modifice instalația electrică fără să se gândească la consecințe, ăstea de la distribuție pot monta și la tabloul de distribuției pe care îl are orce client odată cu contoarul electric ,se poate monta hilar o priză de pământ în apropiere,lângă peretele casei.

    • @Proiectediversediy
      @Proiectediversediy  17 วันที่ผ่านมา

      Astia de la distributie fac prize pentru a nu fura lumea curent.

  • @constantincanciuc7863
    @constantincanciuc7863 12 วันที่ผ่านมา +1

    Greșit!, că dacă cade e cacofonie! ;)

    • @constantincanciuc7863
      @constantincanciuc7863 12 วันที่ผ่านมา +1

      Btw, mulțumesc pentru educație!

    • @constantincanciuc7863
      @constantincanciuc7863 12 วันที่ผ่านมา

      Mi-aduc aminte un prieten foarte drag, cu trei copii și-al patrulea pe drum, și era ceva de lucru la o clădire veche, fără împământare, iar singurele siguranțe erau niște fuzibile.
      ..
      Era ceva provizoriu de făcut până să vină instalatorul, că rămăsesem fără curent la etaj.. și-l văd urcându-se la tabloul vechi antic și de demult, cum trăgea de cele trei faze din alea vechi de aluminiu... Mi-am cerut scuze ulterior, dar l-am speriat zdravăn: am urlat la el să nu pună mână fără să întrerupem înainte...
      ..
      Atât de curajoși sunt unii români! O spun ca unul curentat de multe ori! :)
      ..
      Dacă ar fi, ca cum s-ar spune, dac-ar veni vorba să se discute așa ceva, mi-aș dori să primesc ceva la givăuey: i-aș duce prietenului meu un afdd cu diferențial, cred că de 40. ;) Cred c-am să-i duc și fără.
      ..
      Sunt un inginer proiectant, proiectez și electrice, deși nu-s autorizat. Fiecare proiect al meu trece pe sub incă patru ochi și două ștampile.
      ..
      Nu-i mare lucru, da-i mare lucru, să pricepi că, deși scorul instalațiilor in deviz e cumva neglijabil, socotind investiția per ansamblu, totuși, zgârcirea la 100.. 200 lei poate face diferența dintre a fi sau a nu mai fi.

    • @Proiectediversediy
      @Proiectediversediy  12 วันที่ผ่านมา

      Cu placere.

  • @ionutmuresan7236
    @ionutmuresan7236 17 วันที่ผ่านมา +1

    Da...asa e cum zici..dar daca suntem in apa in acelasi moment....corpul coduce curent...

    • @Proiectediversediy
      @Proiectediversediy  17 วันที่ผ่านมา

      Adica?Pai daca nu conducea curent nu te curentai.

    • @cristicristian976
      @cristicristian976 17 วันที่ผ่านมา +1

      Și sare diferențialul
      Exact cum conduce cablul din clip

  • @juperrr
    @juperrr 17 วันที่ผ่านมา +1

    Ar fi indicat un video cat mai simplist, schitat (acele 2 pagini A4 de care ziceai), stiu ca ai mai facut in trecut, dar o scurta actualizare nu ar strica.

  • @ionutdumitru1387
    @ionutdumitru1387 14 วันที่ผ่านมา

    Salutare ștefan am montat la cineva un boiler oferit de o altă persoană pe motiv că și-a luat unul mai mare după montaj si alimentare a început distracția am verificat cu un aparat de măsură si avea 80V pe carcasă si pe dus robineti .
    Am tăiat cablul de alimentare sa fiu sigur că nu va folosi acel boiler .

  • @al3xspeed
    @al3xspeed 17 วันที่ผ่านมา +1

    Salut! eu am pus doua RCBO pe doua circuite dedicate
    unu de 16ah.30mA pt o masina de spalat si o pompa submersibila si celalat RCBO de 16ah.10Ma pt boiler. Nu am impamantare momentan ca este o casa veche dar am in plan. Este OK ce am pus? Multumesc

    • @Proiectediversediy
      @Proiectediversediy  16 วันที่ผ่านมา +2

      Da este ok.

    • @vestale4
      @vestale4 16 วันที่ผ่านมา

      Si pe restul circuitelor mai ai ceva? Faza lor nu te poate prinde si trimite in lumea celor drepti?
      m = mili si M = Mega

  • @MB2014D
    @MB2014D 17 วันที่ผ่านมา +1

    Salut Nea Stefan , De ce spui sa nu incerce acasa lasa sa incerce in locul tau ii incurajam , fara incurajare si sfaturi nimeni numai are de lucru . Cu toti am fost mici la inceput , problema e ca multi raman marunti.
    Numai asa toate industriile merg mai departe si prea vestitu Daniel o sa fie bucuros nu ca nar fi .😁
    Ai uitat prostul nui prost pana ce nui dai curaj.
    Mult succes iti doresc multa sanatate.
    By the way, I love the crickets sound😂 incerc sa ma obisnuiesc cu ideea floricele, underground, ajuta mult greierii sunetul lor calmeaza sa stai nemiscat😂

    • @corona1372
      @corona1372 17 วันที่ผ่านมา +1

      😂😂😂😂😂😂😂😂😂😂😂😂😂😂😂😂😂😂😂😂😂😂😂😂😂😂

    • @Proiectediversediy
      @Proiectediversediy  17 วันที่ผ่านมา +1

      Corect ce zici dar nu e bine sa ii incurajam ca unii chiar nu se gandesc de doua ori.

  • @mares9755
    @mares9755 16 วันที่ผ่านมา +1

    Depinde cata bere e în corp😂😂😂😂😂

  • @usrn
    @usrn 16 วันที่ผ่านมา +1

    La o mansarda din lemn ce protecție se pune in tablou? AFDD?

    • @Proiectediversediy
      @Proiectediversediy  16 วันที่ผ่านมา +1

      AFDD obligatoriu.
      elektrosystem.ro/KZS-AFDD-3M2p-A-B10-0.03-ETI?search=afdd

    • @Proiectediversediy
      @Proiectediversediy  16 วันที่ผ่านมา

      elektrosystem.ro/KZS-AFDD-3M2p-A-B16-0.03-ETI?search=afdd

  • @nicupurcaroiu1297
    @nicupurcaroiu1297 17 วันที่ผ่านมา +1

    Când am văzut primul tău filmuleț cu piscina divina m am gândit ca trebuia sa l faci pe asta, sau ceva de genul, e mult mai aproape de realitatea care din nefericire s a produs. Ștefane de asta te urmăresc, pentru prezentarea unei probleme altfel, fără limbajul de lemn a altor confrati!?

    • @ghezuroiuenel7654
      @ghezuroiuenel7654 17 วันที่ผ่านมา

      La care confrati te fereri ?Doar curiozitate.Am o banuiala si nu te contrazic dar tot sunt curios ☢☢☢☢☢☢☢☢☢☢

    • @Proiectediversediy
      @Proiectediversediy  17 วันที่ผ่านมา

      Multumesc.La ce limbaj de lemn te referi?

    • @Proiectediversediy
      @Proiectediversediy  17 วันที่ผ่านมา

      @@ghezuroiuenel7654 Si eu .

    • @nicupurcaroiu1297
      @nicupurcaroiu1297 17 วันที่ผ่านมา

      .. Chelaru de exemplu și nu vrau sa dezvolt.

  • @MB2014D
    @MB2014D 17 วันที่ผ่านมา +1

    Au crezut , ca are si hidromasaj 😁 de asta multi nu presteaza atentie sau ii e frica ca ii scartie bugetul

  • @DozatorulCornelius-rt6yy
    @DozatorulCornelius-rt6yy 17 วันที่ผ่านมา +1

    Tu si cu Lucian (Electric Life) explicati cel mai bine.Restul zici ca sunt certati cu limba romana.

  • @vasilepintea6657
    @vasilepintea6657 15 วันที่ผ่านมา

    Care e diferența între RCBO și RCCB?

    • @cristipopa6855
      @cristipopa6855 15 วันที่ผ่านมา

      RCCB-dispozitiv de protectie la curent diferential, Nu are protectie la scurtcircuit si supracurent.
      Se pune pe general iar dupa el se pun MCB-urile pentru circuite.
      RCBO-dispozitiv de protectie la scurtcircuit , supracurent cat si curent diferential, se pune pe circuitele dedicate .
      Adica contine si RCCB si MCB.

  • @simonalexandrubuza1854
    @simonalexandrubuza1854 12 วันที่ผ่านมา +1

    La ce pret se ajunge cu toate componentele de pe panou?

  • @electricus24
    @electricus24 16 วันที่ผ่านมา

    Ai rapsuns efectiv la toate comentariile. Asta arata cat de mult iti pasa sa fie bine si sa inteleaga cat mai mulți. Din pacate, nu il inveti tu pe ala care face de 30 de ani. M-am certat eu cu un idiot (ca nu ii poti spune altfel) care imi spunea ca "ce donne, doferentialu' sare dupa nu stiu cat timp, pana atunci te prăjești. Nunai vrajeli sa ia banii la fraieri". Mda...gandire de "electrician" in 2024 😭😭😭
    Oricum, ai tot respectul meu pe viață!!! Nu renunța!!!

  • @misterc3835
    @misterc3835 16 วันที่ผ่านมา +1

    Unde se poate consulta normativul? Ma intereseaza sa aflu ce ar trebui sa contina un tablou de apartament conform normativului (astfel incat sa fi in siguranta maxima).
    Asta ca sa nu imi puna electricianul ce stie el, si sa pot verifica si eu.

    • @Proiectediversediy
      @Proiectediversediy  16 วันที่ผ่านมา

      th-cam.com/video/arYoxX3ZKHM/w-d-xo.html

    • @Proiectediversediy
      @Proiectediversediy  16 วันที่ผ่านมา

      elektrosystem.ro/Carti_pentru_Electricieni

  • @gabrielmosu4679
    @gabrielmosu4679 16 วันที่ผ่านมา

    te salut Stefan,datorita tie m am hotarat sa pornesc pe acest drum si nu ma opresc pana nu scrie 2A B pe mine,poti sa mi spui cum te ai autorizat si tu si cum a fost toata lupta asta de a lucra corect si legal?
    apropo,astept cu nerabdare videoul promis cu etapele realizari instalatiei de la retea la aparat final

    • @Proiectediversediy
      @Proiectediversediy  16 วันที่ผ่านมา +1

      Nu ai ce sa faci cu 2A/2B daca nu ai o firma atestata pentru ca nu doar autorizarea iti trebuie ci trebuie sa si facture.Deci mai ai nevoie de un electrician autorizat ca sa atestezi firma.
      Facem.

  • @cristianst85
    @cristianst85 17 วันที่ผ่านมา +1

    Bună seara! Cum vă pot contacta în legătură cu o lucrare? Mulțumesc.

    • @Proiectediversediy
      @Proiectediversediy  17 วันที่ผ่านมา

      Proiectediversediy@gmail.com

    • @cristianst85
      @cristianst85 14 วันที่ผ่านมา

      ​@@Proiectediversediy- v-am trimis email.

  • @ionutmaria9173
    @ionutmaria9173 17 วันที่ผ่านมา +1

    Suntem un popor de "las ca merge si asa" iar oamenii care isi fac treaba cum trebuie sunt vazuti ca anormali. Nu stiu cum se face dar in afara toti isi fac treaba si respecta regulile fara sa faca prea multa gargara.

    • @Proiectediversediy
      @Proiectediversediy  17 วันที่ผ่านมา +1

      Afara exista cultura muncii si exista si controale ca fara ele ar face si aia de capul lor.
      Si da cei care fac normalitate sunt vazuti nebuni.Noi suntem tara care pune sarma in loc de colier.

  • @mp4338
    @mp4338 17 วันที่ผ่านมา +1

    Dar ce facem cu tensiunea monofazata balansata, faza/nul, doua gauri egale in diametru, poti roti steckerul in priza, la aparatele mai vechi faza venea pe masa acestuia si te curentai bine mersi, etc?. Au aparut si prize monofazate fara impamintare si de putere mai mica, adica curent mai mic dar balansate.

    • @ghezuroiuenel7654
      @ghezuroiuenel7654 17 วันที่ผ่านมา +1

      In romania nu este permis decat priza schuko,fara pe nu ai de ce sa le instalezi decat daca nu il duce capul p[e electrician.

    • @Proiectediversediy
      @Proiectediversediy  17 วันที่ผ่านมา

      Prizele fara PE sunt de mult dar nu mai sunt permise.

    • @Proiectediversediy
      @Proiectediversediy  17 วันที่ผ่านมา

      @@ghezuroiuenel7654 Multumesc de completare.

  • @TrAxElectronicBrain
    @TrAxElectronicBrain 17 วันที่ผ่านมา +1

    Pai mai Stefane, ie scumpe diferentialele astea. Unde poti pune sarma e pacat sa pui diferential 😅🤣🤣🤣

    • @Proiectediversediy
      @Proiectediversediy  17 วันที่ผ่านมา +1

      Corect 🤣🤣🤣🤣
      Sa stapanesti sanatos noua achizitie.
      E frumos rau osciloscopul man,imi place rau.
      Uite ca mi-am facut si eu achizitie noua pentru banc un multimetru.
      www.arc.ro/seria-dm858-multimetru-digital-de-laborator
      Cand mai strang ceva vreau un osciloscop de la Keysight dar e vreo 4000 euro.Raman la rigol ul meu CRT inca.

    • @TrAxElectronicBrain
      @TrAxElectronicBrain 17 วันที่ผ่านมา +1

      @@Proiectediversediy Mulțam mult. Da și eu am ajuns sa cred ca uneori este mai bine un multimetru de birou, buna achiziție. Legat de osciloscop sincer nu am nevoie de el la cât de performant este, dar nu am avut cum sa refuz oferta, era păcat sa îl las pe mâna altuia :))). Dacă nu am avut jucării când eram mic îmi iau acum, o viata avem :D

  • @raul16nyc
    @raul16nyc 17 วันที่ผ่านมา +1

    ABB F202 A este ok?

    • @Proiectediversediy
      @Proiectediversediy  16 วันที่ผ่านมา

      E bun dar pentru doua circuite.Baga de 63 sau 80A.

    • @raul16nyc
      @raul16nyc 16 วันที่ผ่านมา

      @@Proiectediversediy Am momentat de 25 A montat intr-un tablou si mai am inca unul tot de 25 A pt alt tablou.Nu inteleg la ce te referi pt "doua circuite".

    • @raul16nyc
      @raul16nyc 16 วันที่ผ่านมา

      @@Proiectediversediy Am montat unul de 25A intr-un tablou cu mai multe circuite si vreau sa mai fac un tablou cu inca unul de 25 A.De ce ar fi ok pt tablou numai cu 2 circuite?

    • @Proiectediversediy
      @Proiectediversediy  16 วันที่ผ่านมา

      Adica poti pune dupa un 25 maxim un b10 si un b16,adica doua circuite.Vrei mai multe pune de 63 sau 80 nu de 25.
      25 a tine el ca si contacti.Daca tu pui 2 mcb de 16 dupa el nu cumva 16 cu 16 incarcati la maxim fac mai mult ca 25?

    • @Proiectediversediy
      @Proiectediversediy  16 วันที่ผ่านมา +1

      Depinde si ce simultaneitate ai.

  • @iuliansarpe91
    @iuliansarpe91 17 วันที่ผ่านมา

    Te salut!

  • @stefanStefan-el8ix
    @stefanStefan-el8ix 17 วันที่ผ่านมา

    Bro, pune măna pe fază de după diferențial, arată în clip asta ca să ne convingi că salvează vieți. Daca mai stai cu picioarele în apă sau desculț e și mai bine... Te bagi?

    • @Proiectediversediy
      @Proiectediversediy  17 วันที่ผ่านมา +2

      Eu nu trebuie sa iti demostrez nimic.
      Sa nu iti pui asa ceva acasa ca nu e pentru tine.

    • @electricus24
      @electricus24 16 วันที่ผ่านมา

      ​​@@ProiectediversediyUnii sunt atât de proști încât nu ai ce sa le ceri... E vorba de o rezistenta și de un timp de declanșare. De ce ai pune tu mana să riști (deși sunt șanse superi mari sa nu se întâmple nimic, dar evident că nu ești idiot), când poți demonstra asta perfect cu o rezistenta, calculată frumos, se mai testează și cu testere profesionale și îți arată acolo tot...lasa-i pe lumea lor pe astia, dar din păcate ăștia omoară oameni cu lucrările lor de cacao.

    • @stefanStefan-el8ix
      @stefanStefan-el8ix 16 วันที่ผ่านมา

      @@Proiectediversediy Eu am simțit "energia" până a dat afară diferențialul de 30mA. Și asta în conditii de mediu uscat. Nici nu vreau să mă gândesc cum era să fi fost desculț sau în apă... sau mâna stangă/picior drept.

  • @gabymacovey
    @gabymacovey 15 วันที่ผ่านมา

    Concluzia este sa nu te bagi in piscina cu uscatorul de par alimentat la priza fara diferential in tabloul electric general ! Glumeam desigur ! 😅

  • @viorelcostache2569
    @viorelcostache2569 17 วันที่ผ่านมา +2

    Clientul Nu înțelege ,important pt. EL E Pretul😢

    • @corona1372
      @corona1372 17 วันที่ผ่านมา

      Foarte corect dar ala e un client prost si inconstient.

    • @ghezuroiuenel7654
      @ghezuroiuenel7654 17 วันที่ผ่านมา +1

      Sau intelege dar prea tarziu.

    • @Proiectediversediy
      @Proiectediversediy  17 วันที่ผ่านมา

      @viorelcostache2569 corect de parca pretul ar fi important.

    • @Proiectediversediy
      @Proiectediversediy  17 วันที่ผ่านมา

      @@ghezuroiuenel7654 Si asta e o varianta.

  • @SinnerDeveloper
    @SinnerDeveloper 13 วันที่ผ่านมา +1

    Vorbim de B-uri si-n magazine de profil chiar nu gasesti decat C-uri :))

    • @Proiectediversediy
      @Proiectediversediy  12 วันที่ผ่านมา +1

      Atentie mare la definitia magazinelor de profil pentru ca in acesta denumire nu intra nici hornbach,dedeman ,baduc si nici chiar consolight sau Chorus.

    • @SinnerDeveloper
      @SinnerDeveloper 12 วันที่ผ่านมา

      @@Proiectediversediy corect, mi-am dat seama dupa ce-am scris😅 Ce voiam sa zic e asa: m-am pus sa-i fac lu’ tata un mic panou in garaj pentru ca deja un Dorel i-a legat poarta, prizele, o anexa intr-o doza cu banda…m-am dus la cel mai “dotat” magazin din oras unde pauza B-uri ca deh. Nici magazinele nu te ajuta cand ai nevoie si uite asa din B-uri te trezesti tot cu C-uri.

  • @sorinromeo8186
    @sorinromeo8186 16 วันที่ผ่านมา +1

    Dar de ce in nocturna?

    • @Proiectediversediy
      @Proiectediversediy  16 วันที่ผ่านมา +1

      Pentru ca atunci m-am intors de la lucrare.

    • @Ceausescu_Nicolae
      @Ceausescu_Nicolae 14 วันที่ผ่านมา

      Eu zic ca pentru fundalul cu greierii.....😂😂😂😂 Daca era ziua,mai auzeai tu greieri?

  • @mares9755
    @mares9755 16 วันที่ผ่านมา

    Lucrare mare pe electrica rezidential vine dezvoltatorul nu pui pe la iluminat
    Ce fac majoritatea
    Nu pierd zeci de mii de euro pentru asta facem așa 😢😢😢😢😮

  • @corona1372
    @corona1372 17 วันที่ผ่านมา +1

    Deci ce am inteles eu:daca in cazul cu piscina cei trei aeavu diferentila nu se mai intampla tragedia.

    • @Proiectediversediy
      @Proiectediversediy  17 วันที่ผ่านมา

      Nu este 100% sigur dar avea sanse mari sa scape.

  • @sitonya1482
    @sitonya1482 17 วันที่ผ่านมา +1

    Era mai corect citeste descrierea ,zic.

  • @angelica1337
    @angelica1337 17 วันที่ผ่านมา +1

    Cred ca ma fac si eu membru ca am inteles ca se anunta premii calumea😜😜😜😜😜😜😜😜😜😜😜😜😜😜😜😜

  • @mares9755
    @mares9755 16 วันที่ผ่านมา

    Nu e bun pământul la popești 😂😂😂😂😂

  • @iliebacioiu9586
    @iliebacioiu9586 16 วันที่ผ่านมา +1

    Ce se întâmplă dacă bag mana în apa și sunt izolat fata de pământ? Mai sare diferențialul?

    • @Proiectediversediy
      @Proiectediversediy  16 วันที่ผ่านมา

      Nu mai sare dar sa nu ai faza si nulul in piscina in acelasi timp ca e nasol.

    • @iliebacioiu9586
      @iliebacioiu9586 16 วันที่ผ่านมา

      Bună ziua.Ptr.a încarcă o mașină electrica la casa ce infrastructura îmi trebuie,ce priza,ce grosime a cablului.Am trifazic.Va mulțumesc.

    • @Proiectediversediy
      @Proiectediversediy  16 วันที่ผ่านมา

      Intrebarea ta suna exact ca aia de la VACANTA MARE ,intrebare la concursul STII si Castigi :Pictor rus mort la 3 ani?
      Ce masina,cati KW,ce charger exista?Ce bransament avem,de cat?
      Nu se poate face o calculatie fara date si fara sa vezi locatia.

    • @iliebacioiu9586
      @iliebacioiu9586 16 วันที่ผ่านมา

      @@Proiectediversediy Putere instalata 11 kw.Cablu de la bmpt la tabloul din casa 5×10mp.

    • @iliebacioiu9586
      @iliebacioiu9586 16 วันที่ผ่านมา

      Masina nu o am .Intenționez sa o iau.Nu m-am hotărât de cât sa fie puterea ei.

  • @luk5827
    @luk5827 16 วันที่ผ่านมา +1

    Tot zici de tratarea Nul-ului . Dar daca la BMPT ai deja tratat Nul-ul , si ai 5 fire : L1 , L2 , L3 , N si PE iar casa ii la 20-30m de BMPT . Cum conectezi PE-ul de la BMPT cu PE-ul Natural al casei sa ai T-N-C-S ?
    Daca Nul-ul a fost tratat la BMPT , nu mai trebuie tratat inca odata la casa ! Ai un video cu subiectul asta ?

    • @Proiectediversediy
      @Proiectediversediy  16 วันที่ผ่านมา +1

      Daca la bmpt este deja tratat nului ori duci si tu PPL ul acolo si faci tratarea si mergi in casa pe 5x.Sau suni sa scoata diferentualu si sa puna MCB.Daca nu exista diferential mai poti trata odata nulul in primul tablou.

    • @luk5827
      @luk5827 16 วันที่ผ่านมา +1

      @@Proiectediversediy Este diferential de 300mA in BMPT . Si daca Electrica nu vrea sa scoata diferentialul si sa puna MCB ? Nu se poate racorda PE de la BMPT cu Pamantarea Naturala a casei ? Nu va fi un sistem TNCS ?

    • @Proiectediversediy
      @Proiectediversediy  16 วันที่ผ่านมา

      Daca nu vrea sa schimbe faci reclamatie la ANRE cum ca nu ai tratarea facuta pe o priza sub 4 ohm si sa vezi ce repede vin baietii si iti pun si AFDD daca doresti 😁.
      Se poate racorda platbanda ta la cea din BMPT dar trebuie sa te duci in casa cu 5x16 CUPRU minim sau 3x16.
      De precizat ca in momentul disparitiei diferentialului de 300 din BMPT trebuie sa iti pui tu unul in casa dupa separator.

    • @luk5827
      @luk5827 16 วันที่ผ่านมา

      @@Proiectediversediy Si daca platbanda de la casa se racordeaza la PE din BMPT tot cu o platbanda in loc de cablu de cupru de 16mm ? Asa e OK ? Electrica ii obligata sa schimbe diferentialul de 300mA din BMPT cu un MCB ? Unde scrie asta ? In I7 ? Sau in ce standard ?

    • @Proiectediversediy
      @Proiectediversediy  16 วันที่ผ่านมา

      Ei au voie sa faca BMPT si TT si TN ca asa e standardul de cacat.Tie iti trebuie TN-C-S in casa.Si daca tratarea e facut precar la o priza cu valoare sub 4 OHM si nu este locala atunci ANRE ii obliga sa scoata acel diferential.In toate cazurile au venit si au schimbat fara probleme si daca nu au vrut i-a obligat ANRE .Este dreptul tau sa ai in casa TN-C-S conform .
      Legat de partea cu UNDE SCRIE chiar m-am enervat un pic .Crezi le scot eu din stomac sau crezi ca stiu despre ce vorbesc?
      Cand intrebi unde scrie inseamna ca te-ai pisat pe romaneste pe parerea omului cu care vorbesti .

  • @apanoiu
    @apanoiu 17 วันที่ผ่านมา

    Se pune diferențial la stâlp? Ca de acolo pare sa fi venit cablul. Iar la ce improvizații erau acolo... Cam greu cu bugetul