Card par pressure test & due date ka option hota hai agar extinguisher new hai to manufacturing date ko pressure test manenge agar old hai to government guideline ke anusar test karwayenge
Sir wet chemical extinguisher( stored pressure) mai nozzle k side se leakage ( bund bund tapak ra hai ) sir kya reason ho sakta hai plz help And sir app new video upload nhi karay
Sir koi bhi extinguisher ka operating lever operate karne k baad bhi discharge Nahi hua to us condition me kya Karna chahiye jabki usme pressure healthy hai
Sir pls ye bataen ki.. Kise pta chalta hai ki pressure bhara hai aur hum punchh kare hain to gas bhar aane lagti hai Ander kya hota jo hme pressure dikhata hai aur jise hi pin punchh karte hai to powder nikalne lagta hai
CO2 गैस काट्रीज को हम चेक करते हैं उसका सील होना चाहिए और उसको तौल कर चेक करते हैं कि उसके अंदर गैस है या नहीं उसका खाली वजन और भरा हुआ वेट का उस कट्रीज के ऊपर अंकित रहता है
SIR. JI आपका बताने का तरीका अच्छा है
Thanks
Great knowledgeable information sir 🙏🙏❤❤
Awesome..... bohot sahi aor aasan tareeke se samzhaya sir jee...
Thanks
Very nice sir app ko dil se dhanyawaad jaankari ke liye.
Sir
Very good and very important knowledge
Thanks 😊
Sir your teaching method is very good to all of us to try to understsnd
Apne bahut achha explain kiya...
Hydrotest* hai ...
Thanks
Sir aap bahut acha explain krte ho 👌
thanks please share my video
Best sir
Kya him ABC type ko electrical fire me use kar sakte hai..
Good information
Sir kya sare slender me 15 kg pressure hota h ya sab me alag alag hota h
Waah sir kya samjhaya hai aapne.....
Sir kindly tell me about that the ABC fire extinguisher also come with pre install CO2 cartridge.
Sir agar pressure green pe ho.. to humara pressure kitna hoga.....? Exactly...???
Aap bhaut achcga btate ho sir
Thanks
Sir 35 kg/cm2 se HPT karege. kitna der tak pressure lagana padta h.
Nice sir good knowledge. I like.
You are great sir
Hydrolic/ hydrostatic test / burst test sir ye 5 year m hoty h ya 6 ya 3 agl agl extinguisher k lia alg alg haty h ky
co2 टाइप का हाइड्रोलिक टेस्टिंग 5 साल पर होती है और सभी type का हाइड्रोलिक टेस्टिंग 3 साल पर होता है
Sir kya ye ek bar me hi pura empty ho jata hai kya ......
Sir new Fraser ke liya kay kay sikhna jaruri hai ple comment sir
Thnku sir for explain in detail
Sir Kya isme co2 bhi daal sakte hai.
Thanks sir for explain in details.
Very nice sir
Sir why only mono ammonium phosphate used for ABC type FE.. not other powder??
Super 👌👌👌👌
Nicely explained 👌
goods is job.
Thanks
ABC agnishamak yantra ko use karte samay Kitna Samay lagta hai khali hone per 1 minut ya 2 minut
Sir ji sbhi fire extinguisher khali ka weight or full weight wali video
Can we use same powder in refiling. Which we get from cylinder
What's Metal used to made it container
i thought stainless steel
Sir can you please explain why MAP is better than DCP. Thank you very much.
If ABC type fire extinguisher is over pressured 28 bar, then can we reduce pressure to normal
Thank you sir 😊
Welcome
Welcome
Thanks sir
Sodium bicarbonate ka bhi use hota hai Kay sir DCP fire extinguisher me.plz bataye
haaa bhai dcp me sodium bicarbonate aur potassium sulphate/chloride chemical hota h aur agar ja Abc type likha hoga usme mono ammonium phosphate hoga
Mono anonium phosphate DCP type mein hi hota h
Sir Abc extinguishers me kitna % powder hota h.
Nice sir .🎉Fire extinguisher refilling period as per which norm?
Thanks 😊
मुंह में जायेगा तो क्या होगा
Sir video mai inka IS code with NFPA and hr Chemical ka code btao
Body ka NFPA code btao
Body kitnai pressure pr bnatai h
Nice sir
Sir extigusher mai kitna powder or kitne nitrogen gas hoti hai.
As per capacity
Awesome👏✊👍 sir g
thanks
5 Kg ABC empty & gross weight kitna hota hai sir ji please bata dena
Sir
Aap bhi pura pressure me hai lagta hai
Lag raha hai jaise padha rahe hai school me😁😁😁
Sir mere pass har saal passing k bagarne 750 rs le jaate h . M kya karu
Sir आप का बताने का तरीका बताने का तरीका बहोत अच्छा गला।
Please give me mo number. Mujhe aap se class leni h
Sir hydraulic test m water oil ya gas kis ka use hoty h
एयर प्रेशर 2 मिनट पर डाल के रखा जाता है
Sir mai aap se fire fighting ki alg se classes lena chahta hu
So please help me
Email amansahota1920@gmail.com
Nice Video
Thanks
Sir co2 type . Foom type ka bare thuda batana o nahi na
Sir is fire extinguisherka jo card hota hey uspe hydraulic test kab Karna hey ye likha hota hey ya hydraulic test kab Kiya hey ye likha hota hey?
Card par pressure test & due date ka option hota hai agar extinguisher new hai to manufacturing date ko pressure test manenge agar old hai to government guideline ke anusar test karwayenge
Working pressure kitna hota hai sir
Jai Hind. Sir
THANK YOU SIR 👌
Hydrolictest kita ne minit tak kiya jata hai
2 minutes
@@FIRESAFETYPATHSHALA 2.5 minute as per IS: 2190:2010
Sir what is ammonium phosphate
Sir discharge tube ki lambai kitni hoti hai
As per capacity of fire extinguisher
Sir book mil jayegi kya fire operator ki book
Thanks sir...
Discharge pressure kitna hota h
Thanks sir ji aapka
Thanks
Sir wet chemical extinguisher( stored pressure) mai nozzle k side se leakage ( bund bund tapak ra hai ) sir kya reason ho sakta hai plz help
And sir app new video upload nhi karay
manual valve ya fir automatic solenoid valve me kuchh fas gaya hoga jiske Karan ruk nahi raha please send pictures
FIRE SAFETY TECHNICAL GURU sir extinguisher mai solenaid valve kase ho sakta hh
Sir batae or kya kr sakty hai
extinguisher ka temperature check kar lo kitchen ke under hi temperature ke karan kabhi kabhi ho sakata hai
FIRE SAFETY TECHNICAL GURU thankew sir
Sir eseko kitne durese charge karna hoga?
As per India standard
Sir koi bhi extinguisher ka operating lever operate karne k baad bhi discharge Nahi hua to us condition me kya Karna chahiye jabki usme pressure healthy hai
Change it
Discharge time kya hai sir?
full bhra hua cylinder kitne Der me khtm ho jayega...??? kitne time lgega Pura khali hone me..? sir please btaye
फायर एक्सटिंग्विशर के कैपेसिटी के ऊपर डिपेंड करता है
Discharge time kitna hai,
Discharge of throw kitna hai
Battery Fire ma use karsakta?
Please brief me
Bhai iska duscharge time minimum 8 sec hoga
Throw 2 mitre hoga
Sir powder discharge kitni distance tak Hoga...???.
Up to 3 miter
Sir ham aaka fire ka class karana chahate hai online
Sir pls ye bataen ki.. Kise pta chalta hai ki pressure bhara hai aur hum punchh kare hain to gas bhar aane lagti hai
Ander kya hota jo hme pressure dikhata hai aur jise hi pin punchh karte hai to powder nikalne lagta hai
CO2 गैस काट्रीज को हम चेक करते हैं उसका सील होना चाहिए और उसको तौल कर चेक करते हैं कि उसके अंदर गैस है या नहीं उसका खाली वजन और भरा हुआ वेट का उस कट्रीज के ऊपर अंकित रहता है
kitne time chalega sir ye ABC
Kitna bharte hai sir powder
Wheight gross weight nhi bataya aapne kitna hota hai
Job kaha karteho sr
❤❤
Abc fire extinguisher ka weight kitana hota he
Hello
Sir ji powder me kiya kiya he
🙏🙏🙏
कहा पर पढ़ा रहे हो जी
Sir iska refill charge kitna aata hai 4kg ka
Nitrogen Gas Kitna Bhara rehta hai? Kitna pressure per?
15 bar
Sir
ABC extinguisher के पाउडर में क्या मिलाया जाता है
What is fire rating
Pressure gauge kitna h
Total kitne type he sir powder
ABC व DCP extinguisher में क्या अंतर है
Agar by chance Kisi Ne lagwaya hai aur 3 Sal per refill karvaya Nahin Usne To kya koi jurmana pad sakta hai
Sir 1 video FM 200 or ansul kichen suppression system par bana do thanks
दोस्त जरूर बनाऊंगा क्योंकि जहां काम कर रहा हूं वहां वह सिस्टम नहीं लगा हुआ है इसलिए मैं समझ नहीं पा रहा हूं कि कैसे बनाऊं
Nove1230 me video banaiye
Novec1230
ABC ka ISI No kya Hai Sir
Iski refill ka Kitna Paisa padta hai
Sab fire cylinder ka rifling, hydrolik test, pressure kg to sab yhi hoga
हाइड्रोलिक टेस्टिंग ऑथराइज वेंडर के पास होता है जिसका वह सर्टिफिकेट देता है
Sir ji Dcp election me bhi use hota Hai na aap nhi bataye,
SirKg/ cm2 mtlb ? Sir refilling to 1 year m krne ko bolte hh q ki map m clotting ho jattti h ?
किलोग्राम पर सेंटीमीटर स्क्वायर
Mobile se aawaj aa raha h
Sir ABC type fire extinguisher ko punch karne pr kitne bar pressure se powder riliging hota hai..
Sir.thx You
Sir. App ka no. Chaiye
Background noise bhoot jyada h