PAG LAGAY NG PVC PIPE PARA SA CR ELECTRICAL AT WATER LINE PAVILION VIGAN PROJECT VIDEO#29

แชร์
ฝัง
  • เผยแพร่เมื่อ 25 ก.ค. 2020
  • #Sewerline#Waterline#Pavilion#Rowhouse

ความคิดเห็น • 248

  • @paulinoiigaspar2536
    @paulinoiigaspar2536 3 ปีที่แล้ว +2

    More contents po explaining the details and why you need things to be done this way, vey helpful po specially for students like me. Mas magaling ka pa magturo sa teacher namin boss, looking forward po.

  • @pejarckskilledwtv1081
    @pejarckskilledwtv1081 3 ปีที่แล้ว +1

    Galing u boss mag xplain talagang may mapu2lot na kaalaman sa chanel u. God bless boss dhl hnd u naging maramot sa iyong kaalaman.. shout out boss. Watching from KSA.

  • @alvillagracia0328
    @alvillagracia0328 3 ปีที่แล้ว

    Galing nyu tlg sir safety lahat ang trbho malinis. Watching fr.italy🤩

  • @daniloymasa8335
    @daniloymasa8335 3 ปีที่แล้ว

    GREAT THANKS SIR...ANG GALING MO....GO ON...GO ON...WE ARE LEARNING...

  • @andrespelimer6852
    @andrespelimer6852 3 ปีที่แล้ว

    Ma idea talaga Ang pinoy.. thanks sa video na ito watching from NZ

  • @reinbalagtas8412
    @reinbalagtas8412 3 ปีที่แล้ว +1

    Nakakatuwa po mga video nio dami natututunan!😎

  • @ginalynbadiola6609
    @ginalynbadiola6609 3 ปีที่แล้ว

    Galing! 😊❤️

  • @domejuan6097
    @domejuan6097 3 ปีที่แล้ว

    Ambilis Noy! This week mabubuhusan na yan at maihahanda na rin yun bubong nya...Sarap nyo maging contractor. Kita agad pinaghirapan..More video upload Noy.

  • @prudenciotomagan8752
    @prudenciotomagan8752 3 ปีที่แล้ว

    good job kabayan.mabilis ang trabaho.

  • @daidiazad4784
    @daidiazad4784 3 ปีที่แล้ว

    Nice one kabayan,malinis magtrabaho gusto ko yan.

    • @daidiazad4784
      @daidiazad4784 3 ปีที่แล้ว

      Inaabangan ko tlg ang nxt upload ng videos mo 👍 😁thumbs up

  • @giettoencompany8168
    @giettoencompany8168 3 ปีที่แล้ว

    Ayos kabayan..sa wakas may bago

  • @TeddyBear-tx5ox
    @TeddyBear-tx5ox 3 ปีที่แล้ว

    Good job bro...

  • @conradoramos7562
    @conradoramos7562 3 ปีที่แล้ว

    Kabayan pa shout out naman dyan, from Ramos family in Illinois, always watching your vlog.

  • @jeffersonllm9090
    @jeffersonllm9090 3 ปีที่แล้ว

    salamat dami ko natutunan. :)

  • @braveheartvlog153
    @braveheartvlog153 2 ปีที่แล้ว

    Thank you sa tutorial videos mo sir!

  • @arttadeos6026
    @arttadeos6026 3 ปีที่แล้ว

    good job!

  • @melchorgaling2670
    @melchorgaling2670 3 ปีที่แล้ว

    Tnx for the tip and idea

  • @ericambaking7565
    @ericambaking7565 3 ปีที่แล้ว

    galing naman salamat sa idea

  • @noorrojas2006
    @noorrojas2006 3 ปีที่แล้ว

    Good information point by point we are watching ur video and cost of materials or tools u r using and equipment.

  • @bisayangmaharlikanstv9749
    @bisayangmaharlikanstv9749 3 ปีที่แล้ว

    good job bro

  • @angelineromanbautista7743
    @angelineromanbautista7743 3 ปีที่แล้ว

    grabi nakakalito... sana maintindihan ko pag nakapasa na din ako sa licensure exam😇😇

  • @akosialas3575
    @akosialas3575 3 ปีที่แล้ว

    Maraming salamat po sa mga idea

  • @mrcasful
    @mrcasful 3 ปีที่แล้ว

    Tipid talaha ang pagkakagawa pag ganyang mga dikit dikit n bahay, ni walang footing ang poste

    • @LONBICOOLTV
      @LONBICOOLTV  3 ปีที่แล้ว

      May footing yan kabayan 80x80 tas ang kapal 25 ang lalim nasa 1mtr n nasa ibang mga video k may mga number po ung upload k sa ngaun video#40 n ung vigan project k tingnan mo nlng sa plylist

  • @katrivia
    @katrivia 3 ปีที่แล้ว

    Galing nman una palang iniistila yun pipe line s start ng construction

    • @LONBICOOLTV
      @LONBICOOLTV  3 ปีที่แล้ว

      Oo bro una po ung mga pipe sa ilalim lahat ng slab ssD po

    • @chanrobspierre5840
      @chanrobspierre5840 3 ปีที่แล้ว +1

      kapag slab foundation una po tlga mga tubo. .lahat nasa flooring

    • @LONBICOOLTV
      @LONBICOOLTV  3 ปีที่แล้ว

      Vhong Marchan Oo kabayan una po talaga mga tubo naka baon po sa slab

  • @joshuabalancar7037
    @joshuabalancar7037 3 ปีที่แล้ว

    pashout out sir from ZC

  • @idolkotto
    @idolkotto 3 ปีที่แล้ว +2

    AUTO LIKE

  • @jhanjacob1569
    @jhanjacob1569 3 ปีที่แล้ว

    Manoy pulido ang patrabaho mo so nice mabuhay ka, GOD BLESS

  • @henrichbasalo4117
    @henrichbasalo4117 3 ปีที่แล้ว +2

    wala bang storm drainage na malapit, para doon na discharges ng floor drain, kitchen sink, storm water, lavatory. Para ang ma received lang ng septic tank na discharge is blackwater (discharges from water closet). itoy recommendation lamang. thank you.

    • @LONBICOOLTV
      @LONBICOOLTV  3 ปีที่แล้ว

      Iba po ang tubo ng storm water ang kasama lng po sa sewer line ung sa flr drain at lavatry. At kit sink ang septic namin dyan 3 chamber at may outlet cya.

    • @henrichbasalo4117
      @henrichbasalo4117 3 ปีที่แล้ว

      @@LONBICOOLTV From reliable source: *Where large amount of water waste is coming from shower bath (ang fixture nito is floor drain), laundry and others, it is not advisable to permit entry of these waters into the septic tank. Likewise, all downspout collecting water collecting from the roof, should not be allowed to terminate into the septic tank. Rainwater should be conveyed to the storm (storm drain)- pasado ka dito kasi separate ang linya ng rainwater.

    • @henrichbasalo4117
      @henrichbasalo4117 3 ปีที่แล้ว

      @@LONBICOOLTV * Isa rin sa main reason kung bakit ayaw itapon ang discharges from kitchen sink, floor drain, lavatory...The bacteria will cease to exist in the presence of antiseptics or disinfectants. And to discharge large amount or volume of waste and water containing disinfectants, oil and grease into septic tank will affect and disturb the bacterial activities.

  • @crisantodalapo7776
    @crisantodalapo7776 3 ปีที่แล้ว

    Idol pa shout out
    Crisanto Dalapo

  • @litzryanmatcam3088
    @litzryanmatcam3088 3 ปีที่แล้ว

    Naglaing ka la unay kabayan bilibak kanyam... Nabayag ka ditan kabayan baka makatarus kan iti ilocano..kanayon kayo agannad..more power kabayan!

  • @hermievillaluz4321
    @hermievillaluz4321 3 ปีที่แล้ว

    Safety first sa mga Tao mo.. kailangan nka safety shoes and hard hat...

  • @casperpagharion3277
    @casperpagharion3277 3 ปีที่แล้ว

    Monolithic style pang row na design Mabilis economical

  • @ricaroramos4732
    @ricaroramos4732 3 ปีที่แล้ว +1

    Sir idol guma gawa ba kayo ng small project like 2 storey 6x8 mtrs sa daet cams
    Watching u in middle east,

    • @LONBICOOLTV
      @LONBICOOLTV  3 ปีที่แล้ว

      Pabalik n po kc ako mg tarlac kabayan pero may mga kakilala po ako cntrctor d2 sa bicol. Kung gsto mo po pm k sa fb page ko lonbicool tv

  • @nerpz83
    @nerpz83 3 ปีที่แล้ว

    Pag nangailangan ka additional electrical contractor mo kabayan, try us.salamat

  • @cherileenbautista1774
    @cherileenbautista1774 3 ปีที่แล้ว

    🙋👏👏👏

  • @marvinblogs6747
    @marvinblogs6747 3 ปีที่แล้ว

    Stock bond pala lahat boss matibay tlaga yan parang buhos

  • @PHERN71
    @PHERN71 3 ปีที่แล้ว

    Shout out sa mga bicolano carpenter...

  • @topperbizzare564
    @topperbizzare564 3 ปีที่แล้ว

    *LONBICOOL TV* very nice and execelt video 💕💕💕💕💕💕💕💕💕💕💕💕💕 I LOVE THIS

  • @conradeulalio3494
    @conradeulalio3494 3 ปีที่แล้ว

    idol,my lote ako sa polomolok,south cotabato along highway my sukat na L=40m x W=13m kaso malayo mindanao

  • @gregeoriollagas3247
    @gregeoriollagas3247 3 ปีที่แล้ว

    Male ang instalasyon mo wala kang trap arm sa water closet at floor drain. Hindi pwedeng ang level ng main sewer line mo ay pareho sa mga branches.

  • @marvinblogs6747
    @marvinblogs6747 3 ปีที่แล้ว

    Pa req. Lay out nylon string at pag lagay ng pormas

  • @nonibaris6060
    @nonibaris6060 3 ปีที่แล้ว

    I just have one question, that floor drain between the lavatory and water closet how will you maintain the water seal from not drying out specially in PI where it’s hot and humid, is it necessary to install that, you don’t want sewer gases to back up. Tnx

  • @mervinlim8028
    @mervinlim8028 3 ปีที่แล้ว +1

    Sir.. 300mm lang po ang angat ng firewall in-between each unit? di po ba dapat ay 400mm base on code?

  • @LorenzoGrimaldo-tv7rk
    @LorenzoGrimaldo-tv7rk ปีที่แล้ว

    Good day po sir bakit po magkasama ang linya ng pvc papuntang septic tank mapuno agad yan sa dami ng unit dapat hiwalay ang galing sa lavatory at iba pa pwde conek sa cb salamat sa tutoral gdbls.

  • @mikoomikoo7416
    @mikoomikoo7416 3 ปีที่แล้ว

    Boss paturo naman kung paano kayo mag estimate ng materials at labor

  • @andrespelimer6852
    @andrespelimer6852 3 ปีที่แล้ว

    Magaling Boss..medyo malaking project yan at malaking budget magkano kaya Ang budget niyan boss isang unit finished na

  • @noorrojas2006
    @noorrojas2006 3 ปีที่แล้ว

    Parang kulang ng vapor barrier sa flooring before steel laying & slab concreting at termite protection spraying please explain lang thanks.

    • @LONBICOOLTV
      @LONBICOOLTV  3 ปีที่แล้ว

      Ung sa vapor barrier hind n po pinalagyan ng may ari kabayan

  • @bebotepuknot2631
    @bebotepuknot2631 3 ปีที่แล้ว

    yang NELTEX pvc cement wala pang pangpahid na kasama sa takip. ung U.S brand meron.

  • @KUYACharDyTunayto
    @KUYACharDyTunayto 3 ปีที่แล้ว

    Medyo Malapit na Matapos idol..

  • @isabellapostiglione2899
    @isabellapostiglione2899 3 ปีที่แล้ว

    Sir kapag natapos mo ivevedio mo sir gusto kung makita ang kayarian

  • @ramerojarabe6276
    @ramerojarabe6276 2 ปีที่แล้ว

    Sir, hinde po ba mag back flow sa floor drain pag sabay-sabay gamitin ung water closet?

  • @lifeispain7256
    @lifeispain7256 3 ปีที่แล้ว

    Ganyan gamit nmn d2 sa Qatar bakit Kaya wla sa atin yn kabayan

  • @sayuriordiz8356
    @sayuriordiz8356 2 ปีที่แล้ว

    Sir new viewer po ako paano gumawa ng rodelita panganto ng poste salamat po

  • @noelparreno9996
    @noelparreno9996 2 ปีที่แล้ว

    tanong kabayan, bakit ipinapatong sa rebar ng slab ang electrical pipe? puede din ba yan sa ilalalim ng rebar?

  • @johnlennorbodoso8211
    @johnlennorbodoso8211 ปีที่แล้ว

    Boss tnung ko lng pnu kung mgkron ng leak ung clw mo nkakain sa flooring✌️✌️😁

  • @bebotepuknot2631
    @bebotepuknot2631 3 ปีที่แล้ว

    sabi ng engineer poste muna bago wall. para tama ang sukat ng poste.

  • @ericcsonluy6320
    @ericcsonluy6320 3 ปีที่แล้ว +1

    Nag soil treatment na po ba kayo? Dapat nag back fill din muna ng gravel G1 at may vapor barrier before naglagay ng mga bakal at PVC.

    • @LONBICOOLTV
      @LONBICOOLTV  3 ปีที่แล้ว +1

      Hind n po kabayan pinalagyan ng mayari ng vapor barrier. Cnabi kuna yan sa mga nauna k video Dipende po kc sa nag papagawa soil treatment bago buhosan kabayan

    • @ericcsonluy6320
      @ericcsonluy6320 3 ปีที่แล้ว +1

      @@LONBICOOLTV Okay po. Ngayon ko palang napanuod videos niyo. Tnx.

    • @LONBICOOLTV
      @LONBICOOLTV  3 ปีที่แล้ว

      Ericcson Luy salamat din po kabayan

  • @rommelcoronado8208
    @rommelcoronado8208 3 ปีที่แล้ว

    1

  • @diannetorralba5415
    @diannetorralba5415 2 ปีที่แล้ว

    Sir gaano po kalalim yung hukay for sewerline embedment?

  • @angelolj5951
    @angelolj5951 2 ปีที่แล้ว

    San yun abang ng vent pra s wc.

  • @eugenedenamarca9117
    @eugenedenamarca9117 2 ปีที่แล้ว

    Sir sa 3:20 ano po ba yung inaapply nyo po sa magkabilang dulo ng pvc before ikabit yung isang pvc?

  • @ginaloulabenia2115
    @ginaloulabenia2115 3 ปีที่แล้ว

    Kuya eng., sau ako mgppgawa ng bhay..hehe

  • @ladylynreyes7520
    @ladylynreyes7520 3 ปีที่แล้ว

    Kelan tapos mo dyan kabayan? Kumukuha ka ba ng proj sa bulacan? Pa shout out nman kabayan🤗.

    • @LONBICOOLTV
      @LONBICOOLTV  3 ปีที่แล้ว

      Oo kabayan kumukuha po ako sa bulacan kaso po may mga kasunod n po ako gagawin pagkatapos k po ng vigan salamat po

  • @marvinarmstrong
    @marvinarmstrong 2 ปีที่แล้ว

    Sir yung kitchen sink po ba pwede isama sa linya papuntang septic tank? Ty.

  • @gabrieleducalane8541
    @gabrieleducalane8541 3 ปีที่แล้ว

    Pued pla yon sir..lhat NG takbo NG tubig sa poso negro lhat..d Kya mapuno agd septic tank?

    • @LONBICOOLTV
      @LONBICOOLTV  3 ปีที่แล้ว +1

      Pwd po kabayan. Ang septic namin 3 chamber at may outlet po.

  • @nieljasareno9007
    @nieljasareno9007 3 ปีที่แล้ว

    Boss baka pwede mag apply architect. Hehe

  • @tem9235
    @tem9235 3 ปีที่แล้ว

    sir ilang cm po yong pagbend nong pvc?

  • @kimjanjanelnas4232
    @kimjanjanelnas4232 3 ปีที่แล้ว

    Anu po tawag jan sa parang blower para bumaluktot ang pvc..at magkano po kaya ganyan

  • @ronskietvkatsuper
    @ronskietvkatsuper 3 ปีที่แล้ว

    kabayan edi napuno po agad yung poso negro niyan hindi po b mkkaapekto yun?

  • @ramerojarabe6276
    @ramerojarabe6276 2 ปีที่แล้ว

    Gud day, sir, tanong lng po. Dapat po ba naka slope din ung pipe ng water closet at floor drain papuntang sewer line or nka level lng sya?

  • @ninomalayas1868
    @ninomalayas1868 3 ปีที่แล้ว

    Anong gmit nyo po sa spacer sa slab?

  • @chadcamara8083
    @chadcamara8083 3 ปีที่แล้ว

    Boss pa explain din po yung type of layout nyo ng CHB .. Stock bond po tawag dyan db ?? Paki explain lang po para sa mga hindi nakakaalam .. 👍🏼

    • @LONBICOOLTV
      @LONBICOOLTV  3 ปีที่แล้ว

      May mga video po ako dyan kabayan sa stackbond paki chk nlng po sa mga video ko

    • @chadcamara8083
      @chadcamara8083 3 ปีที่แล้ว

      @@LONBICOOLTV salamat boss sa feedback .. 👍🏼👍🏼

  • @bebotepuknot2631
    @bebotepuknot2631 3 ปีที่แล้ว

    bakit ba parehas yung color ng pvc ng electrical and sewer?

  • @robertpastrana6406
    @robertpastrana6406 3 ปีที่แล้ว +1

    Kabayan Noy, di na ba pinipressure test ang water line, bago buhusan ng semento? Nakita ko nakatupi lang ang bawat dulo ng blue pipe. Ganda ang bilis ng paggawa mo. Salamat po.

    • @leomarguzman6250
      @leomarguzman6250 3 ปีที่แล้ว

      Bugok ei waterline ksma s buhos bubu lng gumgawa nyan pno kng nbasag ung waterline s buhos o my tgas pno p rerepair kng nkbaon n s buhos bubu amp

    • @kenshin3120
      @kenshin3120 3 ปีที่แล้ว

      Leomar guzman sino bah nag sabi nah hindi pwede naka enbed ang waterline? Kung nag leak yan palagay natin pwede naman yan e revice... Maka bulok ka wala ka rin alam.. Wala ka cguro alam dahil ang mga project pang gilid lang ng bahay... Try mo ng mga rise up building para dika mapahiya..

  • @kuyanonoy1639
    @kuyanonoy1639 3 ปีที่แล้ว

    Boss pwede b mag apply,my bakante pb jan

  • @felipedomingojr9990
    @felipedomingojr9990 3 ปีที่แล้ว +1

    Kabayan anu po minimum at maximum na kapal ng adhessive at drypack kapag ngtiles ng flooring?

    • @LONBICOOLTV
      @LONBICOOLTV  3 ปีที่แล้ว

      Manipis lng po .5 pababa ang adhessive

    • @felipedomingojr9990
      @felipedomingojr9990 3 ปีที่แล้ว

      Maraming salamat kabayan.. Pashoutout nmn po davao de oro bgo plang po ako sa construction at gusto ko po tlaga mtutunan lahat sa construction..

  • @marlonedralin4452
    @marlonedralin4452 3 ปีที่แล้ว

    Good day kabayan. bakit iisalang bagsakan ng tubig. diretso ba lahat sa deposito. thanks

    • @LONBICOOLTV
      @LONBICOOLTV  3 ปีที่แล้ว

      Oo kabayan diretso po sa septic lahat yan

  • @joetigsACFTENGR
    @joetigsACFTENGR 3 ปีที่แล้ว

    Kabayan ung paglatag ng electrical tube sa flooring dba dpat nklagay yn sa ilalim ng mga bakal para d maapakan during pagbbuhos

    • @LONBICOOLTV
      @LONBICOOLTV  3 ปีที่แล้ว

      Pwd naman po yan ibabaw ilalim. Kahit naman po nasa ilalim yan kng talagang aapakan maaapakan po yan dahil ang bakal natin dyan 40cm pagitan. Mas dilikado nga po pag sa ilalim dahl kahit bakal lng apakan mo pag malapit sa tubo pwd ma pitpit ang tubo. Pro ung gamit namin n pvc dyan makapal kahit apakan hind cya matutupi.

  • @bossanghell3565
    @bossanghell3565 ปีที่แล้ว

    Kada unit po ba dapat may air vent

  • @edwardsanandres4441
    @edwardsanandres4441 3 ปีที่แล้ว +1

    Good day, boss ask ko mag Kano yung price ng water line tester bili mo? Thanks

  • @mikaykaytv332
    @mikaykaytv332 3 ปีที่แล้ว

    Kabayan baket pantay pantay yung hollowblock sa pag gawa ng pader?

    • @LONBICOOLTV
      @LONBICOOLTV  3 ปีที่แล้ว

      Stackbond po yan kabayan

  • @genarchdesign
    @genarchdesign 3 ปีที่แล้ว

    Kabayan mababaw lang yung wall footing sa pavilion?

    • @LONBICOOLTV
      @LONBICOOLTV  3 ปีที่แล้ว +1

      Nasa 1mtr po 80cm galing sa natural ground kasama tambak nasa 1mtr ung ung footing po yun ung walfooting 40cm lng

  • @otse3329
    @otse3329 2 ปีที่แล้ว

    Gaano kalayo distansya ng firewall to firewall bos? Gaano kahaba ang c-purlins n walang tukod sa ilalim?

    • @LONBICOOLTV
      @LONBICOOLTV  2 ปีที่แล้ว +1

      3.5mtrs po kabayan

  • @francistordiy223
    @francistordiy223 3 ปีที่แล้ว

    Sir idol may ideal budget po ba kayo kayo for 4x6 na lote 2 storey + roof top?
    Thank you god bless.

    • @LONBICOOLTV
      @LONBICOOLTV  3 ปีที่แล้ว +1

      16to18k po kabayan per sqm

    • @francistordiy223
      @francistordiy223 3 ปีที่แล้ว

      @@LONBICOOLTV Maraming salamat po sa reply 💖
      Isa na kasi sa pinag iipunan ko ang pagpapaayos ng bahay 😊
      God bless po.

  • @filecategory6596
    @filecategory6596 2 ปีที่แล้ว +1

    Sir kaya ba ng 20cm ang paglalagyan namin ng water closet at p trap para sa lababo? 20 cm na lang kasi ang natitirang distance kasi may beam ba na ilalim. Baka daw mag butas na sa beam matrabaho na masyado. Nalipat kasi ang lababo at cr. Hini natuloy ang elevation

    • @LONBICOOLTV
      @LONBICOOLTV  2 ปีที่แล้ว +1

      30cm po standard galing n po yan sa wall tiles pag 20cm po hind tatapat ang butas ng water closet cnsya n kabayan l8 reply

    • @filecategory6596
      @filecategory6596 2 ปีที่แล้ว

      @@LONBICOOLTV sir ang ibig ko pong sabihin ay yung gap pataas. Iniiwasan kasi naming mabangga ang grade beam. Balemay elevation na 200 + slab na 100 galing sa beam(pahabol ng client yung elevation from grade beam) kaya ang available lang na pwedeng daanan po ng pipe na 4" ay 200mm. 8 meters po ang byahe nya papuntang sanitary at may kaunting liko. Pa advice naman po sir. Maraming salamat po sa mga naibabahagi nyo

  • @pipongnebo5316
    @pipongnebo5316 3 ปีที่แล้ว

    Kabayan, pwede bang kasama na ang wire pag naglagay ng conduit para wala nang cable pulling?

    • @LONBICOOLTV
      @LONBICOOLTV  3 ปีที่แล้ว

      Dapat po hind muna kasabay ang wire kabayan lalo n kng pvc naman kung flexible pwd mo po muna lagyn ng tire wire

    • @pipongnebo5316
      @pipongnebo5316 3 ปีที่แล้ว +1

      Salamat kabayan.

  • @anabellanicanor7093
    @anabellanicanor7093 3 ปีที่แล้ว

    Diba dapat naka hiwalay ang tubo ng toilet sa floordrain para hindi mapuno yung poso negro

    • @LONBICOOLTV
      @LONBICOOLTV  3 ปีที่แล้ว

      Hind po mapupuno ang septic tank nyan kabayan may outlet po yan

    • @bladimieralarcon5122
      @bladimieralarcon5122 3 ปีที่แล้ว

      San po papunta outlet ng septictank boss?

  • @springmostacio7875
    @springmostacio7875 3 ปีที่แล้ว +1

    ibang style nio sa oag asinta neh? straight lang cla hindi alternate ang mga hallowblocks...

    • @LONBICOOLTV
      @LONBICOOLTV  3 ปีที่แล้ว

      Ok kabayan stackbond po yan

  • @bebotepuknot2631
    @bebotepuknot2631 3 ปีที่แล้ว

    maiilit yung size ng floor drain

  • @germanytarak6020
    @germanytarak6020 3 ปีที่แล้ว

    Idol anu b an tawag jan sa gamit nyo n pampalambot?at magkano kya yan

    • @LONBICOOLTV
      @LONBICOOLTV  3 ปีที่แล้ว

      Nasa video n po bakabayan

  • @brycastulo8844
    @brycastulo8844 3 ปีที่แล้ว +2

    Kabayan, pano po ninyo sinusoksok yung electrical wiring sa electrical lines?

    • @LONBICOOLTV
      @LONBICOOLTV  3 ปีที่แล้ว +3

      Una po alambre po muna tas saka po itatali sa dulo ng wire. Saka po hahatakin . Kc pag wire po agad mahirap makapasok sa tubo lalo n po kng malayo. N

    • @brycastulo8844
      @brycastulo8844 3 ปีที่แล้ว

      @@LONBICOOLTV sir yan po bang electrical lines na yan sir wala pa pong laman sa loob? bali papasukan na lng ng alambre pag magwa wiring na? salamat po

    • @LONBICOOLTV
      @LONBICOOLTV  3 ปีที่แล้ว +1

      Bryn Castulo oo kabayan wala po laman un tubo palng po yun

    • @brycastulo8844
      @brycastulo8844 3 ปีที่แล้ว +2

      @@LONBICOOLTV Salamat po kabayan, at pwede po ba parequest po ng video pag nag wa wiring na po kayo. hehe Nakasubaybay po kasi ako sa channel nyo para makadjust po kami sa actual construction. Maraming salamat po.

    • @LONBICOOLTV
      @LONBICOOLTV  3 ปีที่แล้ว +1

      Bryn Castulo ok po

  • @vickyescalona6393
    @vickyescalona6393 3 ปีที่แล้ว

    Sa apat na unit po Isa lang ba Ang siptic tank..gano po Ang sukat thanks sir

    • @LONBICOOLTV
      @LONBICOOLTV  3 ปีที่แล้ว

      Oo isa lng po kabayan 8 units po yan

  • @nammeneo
    @nammeneo 2 ปีที่แล้ว

    sir my cp nos po ba kayo?

  • @heavendelacruz770
    @heavendelacruz770 3 ปีที่แล้ว

    Prmn bkt po wala kuwarto po,si emer po ito slmt po prmn,

    • @LONBICOOLTV
      @LONBICOOLTV  3 ปีที่แล้ว +1

      May kwarto po yang pavilion isa po

  • @ejpambid1295
    @ejpambid1295 3 ปีที่แล้ว

    boss bakit may ventilation ung mga tubo kung may ptrap naman? ilan dapat ventilation sa isang layout bossing?

    • @LONBICOOLTV
      @LONBICOOLTV  3 ปีที่แล้ว +1

      Isa lng po ang vent dyan kabayan. Bawat water closet

  • @MasterPuding90
    @MasterPuding90 3 ปีที่แล้ว

    Boss pwede po ba kung ang electrical wiring ay sa kisame lahat idadaan salamat

    • @LONBICOOLTV
      @LONBICOOLTV  3 ปีที่แล้ว +1

      Pwd po kabayan kaso kung pati ung
      Mga saksakan or C/O sa kisame ren mas magastos po sa wire kc po sa taas mo idadaan tas ibaba mo ren po. Kaya po mas maganda sa flooring nlng ung mga outlet

  • @marvinblogs6747
    @marvinblogs6747 3 ปีที่แล้ว

    Pvc cement parin ba ung pandikit boss or wala na?

  • @demiebueno1717
    @demiebueno1717 3 ปีที่แล้ว

    saang parte ng vigan yang project mo sir

    • @LONBICOOLTV
      @LONBICOOLTV  3 ปีที่แล้ว +1

      Sa may bulala po kabayan

  • @rlvdesenyomultiskills
    @rlvdesenyomultiskills 3 ปีที่แล้ว

    Advisable ba sa atin sa pinas yung slab on grade 10cm? Salamat po sa sasagot.

  • @kringkringnalasa838
    @kringkringnalasa838 3 ปีที่แล้ว

    Shout out boss at pwede pa hug naren😊 salamat