Dear sir. Please can you make a complete video of wiring of this panel?All incoming and outgoing connections of panel including float switch,booster pumps,pressure switch and internal wiring of panel
Thank u soo much for uploading this very useful information. Sir kabhi kabhi emergency mein koi fault rectify nahi hotha hai. Specially jab hum night duty pe hothey hai. Uss time night mein agar pump ko temporary start kaise karein?? Please aysi koi information bhi share kare. Please reply me. Thank you.
Sorry bhai late reply ke liye 🙏 Agar emergency me pump ko manual on karna hai to har panel ko hand pe chala sakte hai selector switch se waise ye bataye ki aap transfer pump ki baat kar rahe hai ya booster pump ki ?
1# Waise booster pump haito pressure switch se out honewala power direct pump ke contector ke coil volt par desakte hai . 2# aur transfer pump ko auto me chalana hai to roof tank ka float switch ka outhone wala phase wire ko contector me de saktehai istarike. Se pump ko temporary automatic kar sakte hai koi doubt hai pooch sakte ho 😊
sir isi panel ke control wiring aur power wiring pe ek video banaiye aur one by one explain karye jitne bhi saman isme use huwa hai unsab k baare me digram ke jariye please sir
Thanks for this video... I have one question..why latching Relay stuck on middle ON OFF Direction. When I reset it's work after one or two days and again it's stuck same.how to solve this problem?
Sir, mera swimming pool ka filter pump hand mode me chalta hai lekin auto mode me nahi chalata hai. Aur Mai auto mode me chalana chahata hu. To mujhe Kya karma hoga? Please reply karma bhai g
Sir ji kal mere sath ek ajeeb waqya pes ay Auto cut hone k baad pressure automatic release ho jata hai koi istemaal bhi nahi ho raha phir chalu hota hai release krta hai iska kya mtlb prblm kya ho sakti hai Blender problm ya kuch aur please suggest me
Pressure tank ki hawa check kare aur Pump ke output line me NRV (non return valve) hotey hai uska kaam hai jab pump pressure banakar cut hota hai tab nrv pressure hold karta hai . Nrv bhi chek kare. Ji thank for watching my video
requirements k hisab se panels design kiye jate hai ismey basic cheez contactor kacoil volt aapko float switch pressure switch aur selector switch in sab se by pass karke guzarna hai
Sir aapka pressure tank hold nahi kar raha isliye pump jaldi jaldi command le raha hai pressure switch se ... Pressure tank ka bladder change kijiye ya full tank
Booster pump ka 3 pump 1y1 nhi chal raha hai latching relay new reples karne k baad v nhi kamand nhi le raha matlab change nhi kar raha hi latching relay please help me sir please please please
Bhaijaan laching relay ke A1 aur A2 par coil volt check kar jab pump cutoff hokar on hoga tab uski coil ko vilt nahi mil pa raha hai isliye vo changeover nahi ho raha
bhai motor dono auto par chalti ha switch on off b krwata ha but pani ka istemal b ni ha age to 2.5 bar par se ha set point par jata ha of ho kr phir foran pressur down ho jata or phir se on ho jata ha yhai process hota rehta ha pressure hold ni hota jub k pani b istemal ni ho rha or jub auto par off hota ha motor revesre chalti ha kya problm ho skti ha
pressure tank mey hawa check kijiye tank k top mey ek valve hota hai cycle waltube ki tarah waha sey pani aa raha hai tou blador fat gaya tank badal dijiye. ya blador
bhaijaan pressure ko hold karne ka kaam NRV ka hota hai kharab hone par pressure pump k input line sey wapas chala jata hai NRV change kar dijiye. dono pumps ka
Agar aap contector use kar rahe ho to uske coil volt ko float switch se pass karte hue le jayen . Aur direct use kar rahe ho to pump ke line ya nutral ko float switch se pass katwate hue le jayen . Lekin agar apka pump 2 amp se zyada hai to float switch direct use na kare
@@skelectricalguru6363 or sir agar possible hai to 2 motor auto me kaise wiring karte hai.or..matlab sab usme ho..indicator sector switch..puch button...
Floting switch ka connection contractor ke coil volt ko jo supply ja rahi hai usey floting switch se pass karte huwey dena hai . Mai uspar bhi video banaunga jald hi ke float switch kyse connect karte hai
Bhai uska selector switch me problem ho sakta hai. Second option laching relay bhi kabhi kabhi kaam nahi karta hoga ye dono cheezo ko badal kar dekh lijiye
Very helpful information.
Step by step troubleshooting bataya. Or fir usko kaise thik karna h. Vo bhi bataya.
Thx sir
Bhaiya Booster pump ka Penal Wearing pe video Aplood kigiye plzzzzz
I really badly want this video...Tha ks U so much..in this 5 min video ..you teach a lot about pump connection
Aapane bahut acche se samjhaya thank u so Mach
Bro superb information.
But agar ap ek pura video panel or oski wrining keh sath banaoge to it's very very helpful yaar.
We need more video on water pumps related...
Very helpful video thank you sir
Sir... booster pump ka control wiring ka v ak video bna do
Very thank you very much sir you solved my problem I am very thankful
sir aap bahot achhese samjhate hai nice video make more
Good information sir thanks you sir
Dear sir.
Please can you make a complete video of wiring of this panel?All incoming and outgoing connections of panel including float switch,booster pumps,pressure switch and internal wiring of panel
Superb bro👌🏻
Great video brother
Buster pump ka full warinind and practical video bno
Good information sir 👍👍👍 thankyou
Very good my friend you bast master ❤️👍
Sumpump ka video banaye bhother
Expect great video from you again,. Thanks
Good job Bhai good information
Good work brother 👍
Very nice bro tnx infor
Very nice bro
Thank u soo much for uploading this very useful information.
Sir kabhi kabhi emergency mein koi fault rectify nahi hotha hai.
Specially jab hum night duty pe hothey hai.
Uss time night mein agar pump ko temporary start kaise karein??
Please aysi koi information bhi share kare.
Please reply me.
Thank you.
Sir please reply tho kariye.
Sorry bhai late reply ke liye 🙏
Agar emergency me pump ko manual on karna hai to har panel ko hand pe chala sakte hai selector switch se waise ye bataye ki aap transfer pump ki baat kar rahe hai ya booster pump ki ?
1# Waise booster pump haito pressure switch se out honewala power direct pump ke contector ke coil volt par desakte hai .
2# aur transfer pump ko auto me chalana hai to roof tank ka float switch ka outhone wala phase wire ko contector me de saktehai istarike. Se pump ko temporary automatic kar sakte hai koi doubt hai pooch sakte ho 😊
Brother, my pump is not automatic, if you tell me what I can do, I will be benefited, thank you
11kw booster pump kelea kitha litter ka pressure tank chahiye
Super bro. Good explain
Sir latching really ke bare me ek baar praktikal batahiye sir karab hai ya sahi hai
zaroor bhai mai uspar video jald banunga
thanks for watching 👍
Very nice video ... 👌👍
Or video bnao or information chiye booster pump ki panel wiring bnao sir
Use ful video.
Very informative 😍😍😍🙏
Hello sir our company booster pump not working in auto but working on hand please make this video
How to wire the booster pump wye delta connection pls.. give me a compilation diagram sir thanks so much for your respond it..
Great video
Thank you so much. For this video
Very good explain
Sir laching realy ka drowing kaise kiya jata kaise esko 2 moter opreat karte hai pkz drowing me samjana sir
Bro hamary booster pump ka pressure switch bar bar kharab ho jata hai matlab pump khale chalta rahta ha I.
Nice informative video
Sir mera pump trip hora hai baar baar
Mera bhi
Bai
float switch line me neutral reyekatho kaisaa tester me malum hoyakaa
Nutral hai to tester se kaam nahi hoga aap volt meter ya test lamp use karo
Sir aap transfer pump & booster pump ke panel ke connection full vedio banaye please sir
sir isi panel ke control wiring aur power wiring pe ek video banaiye aur one by one explain karye jitne bhi saman isme use huwa hai unsab k baare me
digram ke jariye please sir
Thanks for this video... I have one question..why latching Relay stuck on middle ON OFF Direction. When I reset it's work after one or two days and again it's stuck same.how to solve this problem?
Due to faulty Laching relay it's happening
Super sir
Very good
Ye panel manually operate bhi ho raha he? Ya only auto
Yes
Thanks thanks thanks
Sir, mera swimming pool ka filter pump hand mode me chalta hai lekin auto mode me nahi chalata hai. Aur Mai auto mode me chalana chahata hu. To mujhe Kya karma hoga? Please reply karma bhai g
Very nice
Sir Esme ek aur relay hota hai sesa ka us ke bar me batay
Sir ji kal mere sath ek ajeeb waqya pes ay
Auto cut hone k baad pressure automatic release ho jata hai koi istemaal bhi nahi ho raha phir chalu hota hai release krta hai iska kya mtlb prblm kya ho sakti hai
Blender problm ya kuch aur please suggest me
Pressure tank ki hawa check kare aur Pump ke output line me NRV (non return valve) hotey hai uska kaam hai jab pump pressure banakar cut hota hai tab nrv pressure hold karta hai .
Nrv bhi chek kare.
Ji thank for watching my video
Thanks ☺️☺️☺️
Good
And drawings also need explain.
Sir,
Please,
Shall you make internal penal control diagram practically
Sir panel kai tarike ke bante hai requerment ke hisab se 😊
SAR is painal Ka daigaram banake samjhaiye Puri wairing please
Sir same penal h
Par pressure switc kam krta h h
Pr pupm bnd ni hota h
Pressure switch nikaal kar saaf karo
Laching relay ka wiring kaise karte hi
Dhaneyvadapaerikesancatarolkebaremebataiy🙏🙏🙏
Bhai transfer pump ke bare mein batao transfer pump chal Nahin raha
Bhai auto pe on krne ke bad 1 ya 2 mintis me band ho jati h moter kya problam hoga
Bhai Mera pas do pupm lagay ha or wo low level day rahy ha nahe wo hand par chlta ha nahe ato par sir plz kuch batao me bhot par shan ho
Thanks thanks
Hi... Sir without latching relay how can be make a change over for booster pump
There is many options glass relay one of them
@@skelectricalguru6363 do you have any video for that
Dono indicator pump trip dekha rahy hain kioun
Sir booster pump ka curcuit diagram bataye
requirements k hisab se panels design kiye jate hai ismey basic cheez contactor kacoil volt aapko float switch pressure switch aur selector switch in sab se by pass karke guzarna hai
Sir booster pump 1bar se niche jane ke bad start ho raha h
Kya fault ho sakta h?
Pressure switch open karke clean karo fir bhi same problems ho to P.Switch replace kar do
Nice video
Salam bhai
Walykum Assalam
Sir yah panel ka full wiring diagram wala video banaye please
Thanks bro
You are welcome bro
Sir mera buster pump dono motor on off on off continue pickup kar RHA hai kya fault ho sakta hai sir
Sir ji aapka pump set me agar pressure tank hai to uska blader fat chuka hai aisi halat me pressure tank change karna hoga
Pressure tank pressure hold karta hai tank bladder fat jane se pressure hold nahi hoga jiski wajah se pump jaldi jaldi on/off hoga
Sar mera pump on off on of hota paresar nahi bana raha h motor nahi Cal rahi h
Ok aap pic send karo complete panel aur pump set ki
Sir mera ek problem hai menul me motar chalta hai auto me karta hoon to moter nahi chalta hai plz kia problam hai
Float sw,, pressure sw,, laching relay ,, aur selector sw ka auto wala link ye sari cheezo ko one by one check kar ley
Sir mera 1 problem hey Auto me chalatahu to alternet 3,4 second me change hote raheta hey kya problem hey plz bata digiye...
Sir aapka pressure tank hold nahi kar raha isliye pump jaldi jaldi command le raha hai pressure switch se ...
Pressure tank ka bladder change kijiye ya full tank
To selected shoes kharab hai ya kuchh aur problem hai
Booster pump ka 3 pump 1y1 nhi chal raha hai latching relay new reples karne k baad v nhi kamand nhi le raha matlab change nhi kar raha hi latching relay please help me sir please please please
Bhaijaan laching relay ke A1 aur A2 par coil volt check kar jab pump cutoff hokar on hoga tab uski coil ko vilt nahi mil pa raha hai isliye vo changeover nahi ho raha
Sir Kaise check karte hai Lachting really ho ek baar bata hi ye practical
Float switch up /dn karke check kar sakte hai dono pump auto mode me hona chahiye
Sir aap bataya nahi latching realy karab hai ya nahi hai ho ek baar batahiye
Sir,2motor se 1motor automatic on off hotaye dosra motor automatic hamesha chalthye off nehye horye kaye problem hey please bolihye sir
Jo motor regular chal raha hai Uske selector switch mey ya coil volt ki wiring me problem ho sakta hai proper check kijiye
Sendme control wiring drawings
Selected shoes ko kaise sahi Kiya jaaye kaise pata chalega ki kharab hai sahi hai yah per lagata hun chalta hai motor ke band ho jata hai
Kya iski full wiring bta sakte hai plz
Please drawing ke sath wiring samjaho
Prssur jeyada hone pe keya kare
Pressure switch se water pressure ko adjust karna hai
Sir pump manual me chalta h. Auto me kyo nahi chalta
Bhai painal ki wiring kaise karte hai batao
Transfer pum k baare m batayee sir please please please sir
bhai motor dono auto par chalti ha switch on off b krwata ha but pani ka istemal b ni ha age to 2.5 bar par se ha set point par jata ha of ho kr phir foran pressur down ho jata or phir se on ho jata ha yhai process hota rehta ha pressure hold ni hota jub k pani b istemal ni ho rha or jub auto par off hota ha motor revesre chalti ha kya problm ho skti ha
pressure tank mey hawa check kijiye tank k top mey ek valve hota hai cycle waltube ki tarah waha sey pani aa raha hai tou blador fat gaya tank badal dijiye. ya blador
bhaijaan pressure ko hold karne ka kaam NRV ka hota hai kharab hone par pressure pump k input line sey wapas chala jata hai
NRV change kar dijiye. dono pumps ka
Ak panel me arlm sound aa rah hai kyu
Panel drawings required,can provide me sir...
its depends on requirements bro
Please show me flow switch connection in booster pump
Agar aap contector use kar rahe ho to uske coil volt ko float switch se pass karte hue le jayen .
Aur direct use kar rahe ho to pump ke line ya nutral ko float switch se pass katwate hue le jayen .
Lekin agar apka pump 2 amp se zyada hai to float switch direct use na kare
Sir latching rely ka connection bta do plz.kaise karte hai
Thanks for reply i will make video for laching relay connection
@@skelectricalguru6363 or sir agar possible hai to 2 motor auto me kaise wiring karte hai.or..matlab sab usme ho..indicator sector switch..puch button...
Nice
Sir Mera irrigation pump LP Trip ho Raha hai kya issue hoga
pump ka load check kijiye single phase motor hai tou capacitor change kijiye
Floating switch ka connection kaise krte h panel me
Floting switch ka connection contractor ke coil volt ko jo supply ja rahi hai usey floting switch se pass karte huwey dena hai .
Mai uspar bhi video banaunga jald hi ke float switch kyse connect karte hai
Give more video
Need full diagram of control panel
SIR PUMP AUTO PEE ON NAHI HO RAHA PLZ ANYONE HELP ME
HP 10 HP transfer pump sometime auto not working sometime am hand hand 10 second after working auto please please in inform the problem thank you
Bhai uska selector switch me problem ho sakta hai. Second option laching relay bhi kabhi kabhi kaam nahi karta hoga ye dono cheezo ko badal kar dekh lijiye
I want to ask somthing