ความคิดเห็น • 14

  • @scorpion_21_96
    @scorpion_21_96 4 หลายเดือนก่อน

    Так по русски на английском )
    Спасибо за видео

  • @resuls.9332
    @resuls.9332 ปีที่แล้ว +1

    Very nice explanation ! Thank you . Please keep poste the such videos. Can you share the source of the 60 minutes video which you are explaining system via it.

  • @sauravghosh7064
    @sauravghosh7064 4 ปีที่แล้ว +2

    worked on balclor
    metering pump was plastic wilden pump
    got stuck mostly ,has to be open and piston has to be freed
    system setting for fresh water ballasting was not good,alams went haywire when operating in river or lake

  • @jensonfernando1165
    @jensonfernando1165 3 ปีที่แล้ว +1

    NICE explanation thank you sir realy help ful

  • @funniestvideos8435
    @funniestvideos8435 3 ปีที่แล้ว +1

    Good day sir..I ask some questions in BWTS. what is the cooling water high temp shout down point?how many degrees? And also what is the GDS feedback value shout down point.? How many percent? Thank you for your reply..

    • @Adventure-Story
      @Adventure-Story  3 ปีที่แล้ว +1

      Hello I have not worked with this system and I don’t have any information about it!

    • @junan6889
      @junan6889 3 ปีที่แล้ว +1

      cooling water high temp points are 43 degrees alarm , 45 degrees shout down ...
      cooling water means ... Using fresh water for Cool down PRU(Power rectifier) ...
      and ... GDS Feed back value are... 25%(LeL) Alarm, 50%(LEL) Shout down..

  • @aveeksarkhel3237
    @aveeksarkhel3237 3 ปีที่แล้ว

    There is nothing to remove sediments in this system. Creates problem for use in river ports.

  • @sunnyk7153
    @sunnyk7153 3 ปีที่แล้ว

    How to run it in emergency mode? If GDS sensor not working? Can you explain the steps for operating in emergency mode?

    • @Adventure-Story
      @Adventure-Story  3 ปีที่แล้ว

      Hello really i don't know this kind of system how it operates in emergency mode.

  • @chantangelo.22
    @chantangelo.22 3 ปีที่แล้ว

    Do you have any idea Sir. Our Tro set Value is 5-10ppm ours keep dropping 5ppm below we are having a hard time maintaining it.
    Thanks

    • @Adventure-Story
      @Adventure-Story  3 ปีที่แล้ว

      Hello what kind of ballast system you have ?