inverter daikin PCB repairing / inverter daikin PCB ripair
ฝัง
- เผยแพร่เมื่อ 5 ต.ค. 2024
- inverter daikin PCB repairing / inverter daikin PCB ripair
daikin inverter pcb repair
daikin inverter pcb repairing
indoor inverter pcb repair
indoor inverter pcb repairing
pcb repair
pcb repairing
inverter pcb repair
inverter pcb repairing
outdoor inverter PCB repair
outdoor inverter pcb repairing
kaise ac cylinder blast ho gaya
ye dekho kaise ac cylinder phat gaya
ac cylinder se savadhan rahiye dosto
Daikin inverter AC PCB repair
Mitsubishi AC indoor PCB repair
Toshiba Inverter AC PCB repair
inverter PCB repair
cassette ac pcb repair
Daikin inverter AC Pcb price
Samsung Window AC PCB repair
Daikin AC Remote repair
Daikin inverter AC outdoor PCB connection
Daikin PCB board replacement
Mitsubishi AC error code light blinking
Daikin inverter AC indoor unit not working
S.k Electronic's work
Qphix appliance repair
Electric Locha
ANM TECHNICAL
Haseeb Electronics
Dilip vare
TRUE DIY
Multitech lnstitute OF Advance Technologies
Fully4world
ABC Mobile Institute of Technology
Rajkumar Kushwaha
HVAC Work
Skill Development
ASR Service center
Babar Electronics HVACR
AR PCB
Forever Tech
Total power solution
Safarnama
RAC world
A2Z construction
Electric work center
SidTalk
#gnactech #repair #ac
Good job
Ab night me chalta hai perfect, morning me chalu band hota hai compressor
Indoor pcb change kiya tha 7 months pehle, but dusra model inverter ka hai
Superb troubleshooting..
Is the other capacitor for the outdoor fan..or is there any other capacitor for the fan..??
Bcoz i have a fan not starting or after push start ,runs slow..
Ur advice is requested!!
Fan capacitor replace
@@gnactech its inverter Panasonic model,, so its on pcb board capacitor..!!
That why i asked if it was the other large capacitor next to the one u replaced..
Easy to find on the PCB..??
@@kurien737 RB-166-48 (D) at the start of the video is the Black Box Rectangle shaped, Outdoor Fan capacitor. 2uF 450 VAC. Panasonic AC Inverter outdoor has the same one but check other videos also.
Daikin ductable AC hot and cold 10 minut chalta hai bad mein band Ho Jata h
Accha jii
Shop kha h
bhai kpnsi company ka pcb sasta pdta h gr khrab hua ?
Inverter PCB and non inverter PCB
Board nikale bina kese check karte he?
Bord ko nikale bina aap ko erro dekhna hoga.। Agar U2, ERROR hoga tou pcb me capacitor kharab hota hai.।
Aur dushra tarika.। Tong tester se capacitor wale bhag ko chek kijiye.।। Capacitor point me rakh kar.।। 20mfd&15mfd hona chahiye
@@gnactech ye bada capacitor lagane se koi issue nahi hoga na ? mere board pe capacitor value 8uF aa r ahi he . compressor 30sec chak k off hota he.
Cap. 20 mfd change ker ne ke baad bhi same Problem aata hai ,
Vo pcb problem nai he jab 20 mfd 6mfd se jyada Kam ho jata he tab compressor bhi damage ho jata confirm Kiya hu me dusre ac me laga ke
Sir mera inverter daikin 1 ton 5 star ac me morning me 5 min compressor chalta hai, phir bhand ho jata, phir 5 min ke baaf phir se restart hota hai compressor, bit night me perfectly full time chalta hai compressor chalta hai, reason kya ho sakta hai?
20 mfd capacitor cheng karo
Contact number??