LIGAÇÃO ELETRICA AR ELECTROLUX INVERTER R32

แชร์
ฝัง
  • เผยแพร่เมื่อ 20 ม.ค. 2025

ความคิดเห็น • 51

  • @polonortecursos8378
    @polonortecursos8378  10 หลายเดือนก่อน +2

    ✅VEJA NOSSOS CURSOS NOS SITES ABAIXO!
    ✔CURSO DE REFRIGERAÇÃO DOMÉSTICA (GELADEIRA E FREEZER)👉go.hotmart.com/O25907570H
    ✔CURSO DE AR CONDICONADO SPLIT (CONVENCIONAL E INVERTER)👉go.hotmart.com/O47369867R
    ✔CURSO DE MÁQUINA DE LAVAR👉go.hotmart.com/R70942902O
    ✔CURSO DE MICRO-ONDAS👉go.hotmart.com/S72826106T
    ✔ CURSO DE LAVA E SECA 👉 go.hotmart.com/N78709309H
    ✔CURSO DE AR CONDICONADO SPLIT (CONVENCIONAL E INVERTER)👉go.hotmart.com/O47369867R
    ✔CURSO DE EXPOSITORES (CERVEJEIROS, BALCÕES, ILHAS DE CONGELADOS, CONTROLADORES ELETRÔNICOS)👉go.hotmart.com/S60598485N
    ✔ CURSO DE REPAROS EM PLACA DE LAVADORAS ELECTROLUX DO PROFESSOR DOGLAS👉 go.hotmart.com/P71638236X
    ✔CURSO DE REPARO EM PLACA DE LAVADORAS BRASTEMP/CONSUL DO PROFESSOR DOGLAS👉go.hotmart.com/O71638249E

  • @Ksksksoekekjejwkwkwkw
    @Ksksksoekekjejwkwkwkw 5 หลายเดือนก่อน +3

    Eu agradeço muito amigo o único vídeo que ensina perfeitamente ja ganhou um escrito kkkk obrigado de verdade

  • @rafaelpinheiro4626
    @rafaelpinheiro4626 10 หลายเดือนก่อน

    Obrigado, professor Leandro por compartilhar suas experiências conosco.

  • @cleonesinstalacoesecursode3107
    @cleonesinstalacoesecursode3107 28 วันที่ผ่านมา

    Vi o manual de um aqui ele da as duas opções tanto na unidade evaporadora como na condensadora.

  • @AdrianoDonizete
    @AdrianoDonizete 2 หลายเดือนก่อน +1

    Muito bom parabéns 👏 tamos juntos abraços 🙏

  • @eleodororodriguez3796
    @eleodororodriguez3796 6 หลายเดือนก่อน +1

    Muito obrigado pela informação parceiro, um abraço desde Benjamin Constant - Amazonas.

  • @luiz1paulo2almeida3
    @luiz1paulo2almeida3 5 หลายเดือนก่อน

    Excelente aula, dá pra qualquer um ver e evitar erros.

  • @paulocesarwanzeler
    @paulocesarwanzeler 10 หลายเดือนก่อน

    Muito obrigado! Excelente explicação 👍🤝

  • @danielfarias3854
    @danielfarias3854 5 หลายเดือนก่อน

    Muito agradecido, deu certo aqui ajudou muito esse seu vídeo amigo

  • @annasantannafilho623
    @annasantannafilho623 3 หลายเดือนก่อน

    Muito boa a explicação 👏🏿👏🏿👏🏿👏🏿

  • @saveiroevolusom4396
    @saveiroevolusom4396 หลายเดือนก่อน

    Muito bom esse video o parabens 👏

  • @fabiogabrielliantonio7437
    @fabiogabrielliantonio7437 10 หลายเดือนก่อน

    Ótimo conteúdo!!

  • @rogeriolima7186
    @rogeriolima7186 9 หลายเดือนก่อน

    Obrigado por compartilhar seu conhecimento!

  • @alexandresr3845
    @alexandresr3845 หลายเดือนก่อน

    Boa 🤝🤝

  • @danielbritovieira5784
    @danielbritovieira5784 8 หลายเดือนก่อน

    Boa noite muito obrigado por ter espricado.Eu gostaria de saber como que eu faço pra fazer esse curso.

  • @edersanches3729
    @edersanches3729 8 หลายเดือนก่อน +1

    Da modelo anterior é azul marrom preto, construção da placa igual, não sei o ipm dessai se é resistente, parece que o dissipador sao muito pequeno pra trabalhar em conjunto com ponte retíficadora e ipm

  • @isaacfigueiredo9012
    @isaacfigueiredo9012 11 หลายเดือนก่อน +1

    Sempre liguei 1 neltro 2 fase 3 sinal

  • @jrrefrigeracaoarcondiciona9345
    @jrrefrigeracaoarcondiciona9345 6 หลายเดือนก่อน

    Boa tarde eu tenho uma dessa que foi alimentado o ponto 220 volts na condensadora no Borne 1e3 funcionando e agora o ventilador da condensadora não liga mas

  • @alexnascimento9795
    @alexnascimento9795 8 หลายเดือนก่อน

    Top dica🎉

  • @alexotero8498
    @alexotero8498 5 หลายเดือนก่อน

    Show 🎉

  • @ConvênioSecultConvênioSecult-P
    @ConvênioSecultConvênioSecult-P 3 หลายเดือนก่อน

    muito bom

  • @MARLONCOSTA27
    @MARLONCOSTA27 3 หลายเดือนก่อน

    o fio de comunicão na chave de teste ele mostra 127v, ou não mostra nada, ou voltagem menor?

  • @EDEN77BSBDF
    @EDEN77BSBDF 9 หลายเดือนก่อน

    Amigao..minha electrolux dfi80 tem um aviso vermelho de um desenho de temperatura no painel..o que sera isso ?

  • @cladasmaquinas
    @cladasmaquinas 8 หลายเดือนก่อน

    Eu tenho um Eletrolux pi18r

  • @johnathanmoraes2681
    @johnathanmoraes2681 6 หลายเดือนก่อน +1

    Fiz a interligação pela condensadora de 18k mesmo porque esse tipo de equipamento não vem com cabo de plug para tomada sendo assim a alimentação é pela condensadora.

  • @MatheusAlves-c1i
    @MatheusAlves-c1i 4 หลายเดือนก่อน

    Qual é a tubulação?

  • @mariaenedinadasilvaqueiros5775
    @mariaenedinadasilvaqueiros5775 11 หลายเดือนก่อน

    Show muito bom

  • @carlosjosebraz6679
    @carlosjosebraz6679 9 หลายเดือนก่อน +1

    A Electrolux deveria fazer um vídeo explicativo igual a esse. Ou detalhar melhor o diagrama elétrico que ela colocou no manual. Quem não está acostumado a olhar o manual, está sujeito a errar.

    • @31161533
      @31161533 5 หลายเดือนก่อน

      Vdd

  • @arumatanmoda
    @arumatanmoda 10 หลายเดือนก่อน

    Quanto tempo demora pra fazer o curso ?

    • @polonortecursos8378
      @polonortecursos8378  10 หลายเดือนก่อน

      Clique no link abaixo para acessar nosso site e ver informações sobre o curso. Em caso de dúvidas lá tem um botão para chamar no whatsapp
      www.polonortecurso.com.br/ar-condicionado

  • @joycesimoes6612
    @joycesimoes6612 4 หลายเดือนก่อน

    Com qual amperagem ela trabalha de 12 mil btus .
    Instalei uma que está dizendo no diagrama que ela trabalha com 7,5
    Mas ela só está dando 4,1.
    Está correto ?

    • @cristinapaiva6725
      @cristinapaiva6725 2 หลายเดือนก่อน

      Ela nao pode passar de 7,5

    • @carlosbatista7585
      @carlosbatista7585 หลายเดือนก่อน

      Pode ser falta de fluido refrigerante

  • @anaklin2478
    @anaklin2478 6 หลายเดือนก่อน

    Fomos fazer a instalação de uma máquina eletrolux 12.000 e ela nao estava esquentando, após medição com manometro ela deu 350 psi, retiramos o gás ela caiu para 200 porém parou totalmente, o que pode ser ?

    • @ailtonlira8303
      @ailtonlira8303 6 หลายเดือนก่อน

      Verifica se sucção deve n esta sugando e pelo q vc falou apenas expandio por isso essa pressao

  • @musicml8576
    @musicml8576 หลายเดือนก่อน

    Pelo que vi o mínimo de tubulação é 2 metros?

    • @carlosbatista7585
      @carlosbatista7585 หลายเดือนก่อน

      Sim, a única marca que exige 3 metros e o Samsung, o Consul o mínimo de tubulação é 1 metro, tudo isso seguindo o manual

  • @edersanches3729
    @edersanches3729 8 หลายเดือนก่อน

    ipm lm393 l6e da anterior

  • @Davyanjo
    @Davyanjo 8 หลายเดือนก่อน +1

    Resumindo:
    N1(Fase) + 3(Fase)
    2(comunicação)
    Terra conectar na carcaça

  • @marciolopes1352
    @marciolopes1352 9 หลายเดือนก่อน

    Ligo o 3 como sinal,mas pelo q vi no vídeo e incorreto ne isso ?

  • @MatheusAlves-c1i
    @MatheusAlves-c1i 4 หลายเดือนก่อน

    Galera a tubulação dessa maquina é qual ???? 1/4 e mais o que?

  • @passroazul2010
    @passroazul2010 3 หลายเดือนก่อน

    A Eletrolux deixou a desejar, primeiro que a grande maioria das máquinas a borneira 3 é sinal, segundo, no manual tem um esquema elétrico que mostra uma suposta torneira de alimentação que não existe, daí você tem que ligar alimentação na mesma borneira de comunicação

  • @stradacorsa
    @stradacorsa 5 หลายเดือนก่อน

    no começo vc diz que está ligação esta errada, so pra dar mais confusão

  • @suzanagomes4641
    @suzanagomes4641 5 หลายเดือนก่อน +2

    Porque a Electrolux não usou o (L) de referência, não indico esse ar, parece um robô pra desmontar

  • @joaosidnei7045
    @joaosidnei7045 10 หลายเดือนก่อน +3

    É o pior lançamento de ar condicionado da Electrolux não indico para ninguém não tem espaço para fazer as conexões dos cabos

  • @glenio140
    @glenio140 7 หลายเดือนก่อน

    Eu comprei o curso de.geladeiras! Não é bom não! Deixa muito a desejar.

  • @paulomoraes4979
    @paulomoraes4979 10 หลายเดือนก่อน

    Responde o WhatsApp por favor...

  • @TheNetofilmes
    @TheNetofilmes 6 หลายเดือนก่อน

    Pelo visto essa maquina é pessima.
    Alem de fazer essa armadilha para os técnicos.
    Nao recomendo eletrolux nem para inimigo kkkk