  • @paullyons4624
    @paullyons4624 4 ปีที่แล้ว +201

    C1 for that door

  • @daanwilmer
    @daanwilmer 4 ปีที่แล้ว +168

    Given your pricing, this is how I imagine the checklist for a £100 (inc. V.A.T.) EICR would look like:
    [ ] Radio works when plugged into socket
    [ ] Wires are connected inside the distribution board
    [ ] House is not currently on fire due to a short circuit (pass if on fire due to non-electrical causes)

    • @Fishbait075
      @Fishbait075 4 ปีที่แล้ว +35

      You'd even get out of the Car/Van?
      [ ] Property is located where address states.
      [ ] Property is a building.
      [ ] Property is not currently on fire.

    • @efixx
      @efixx 4 ปีที่แล้ว +4

      Brilliant!

    • @paulsims8461
      @paulsims8461 4 ปีที่แล้ว

      No

  • @videomaster8580
    @videomaster8580 3 ปีที่แล้ว +35

    5:31 "If Mrs Jones falls down the stairs and snaps her neck, thats a C2" Strangely enough C2 is one of the Vertebrae in the neck! poor old Mrs Jones.

    • @markrainford1219
      @markrainford1219 3 ปีที่แล้ว +1

      I'll give you a thumbs up for that.

    • @weptbody7613
      @weptbody7613 2 ปีที่แล้ว

      Laughed out loud to that mate. 😂

  • @markhorton8578
    @markhorton8578 3 ปีที่แล้ว +3

    I liked the door drop being left in. So many of these professional videos edit out all the real life stuff.

  • @AlfsMoon
    @AlfsMoon 4 ปีที่แล้ว +4

    Love this video . As an apprentice I found this really useful. Hope your head is ok after that nasty bump.

  • @stevehenke678
    @stevehenke678 4 ปีที่แล้ว +8

    I'd say the rcd is C3. Yeah you could argue there's a safety concern, but it's not an electrical issue. Old Fanny falling down the stairs cause the lights went off sucks, but she wasn't electrocuted.

  • @THEELECTRICSIDEOFTHINGS
    @THEELECTRICSIDEOFTHINGS 4 ปีที่แล้ว +14

    I find it fascinating the electrical difference between country have a great day and be safe 😊🇨🇦

  • @stefanmeier6763
    @stefanmeier6763 4 ปีที่แล้ว +95

    Pricing (Nuremberg, Germany):
    I only do such inspections on an hourly basis. So i would estimate around 6 Hours for that kind of building, 85€/hour + 27.50€ (Tester) + 22€ (Car - if within the town)
    So:
    510,00€(Labour)
    + 27,50 (Equipment)
    + 22,00€ (Car)
    =559,50€
    + 16% VAT (89,52€)
    = 659,02€
    I know, there are guys that do it for less than 200€, but if you pay peanuts, you'll get monkeys...

    • @shaunsparky5354
      @shaunsparky5354 4 ปีที่แล้ว +5

      Perhaps yours is a more suitable way of pricing....Unfortunately, being competitive (Commercially Viable) is a whole other argument!
      Actually, I like your model!!

    • @RubenKelevra
      @RubenKelevra 4 ปีที่แล้ว +1

      Sounds pretty reasonable if you ask me, greetings from NRW :)

    • @kittsdiy
      @kittsdiy 4 ปีที่แล้ว +4

      Ok i move to Germany ..if i ask that rate in Belgium .. i don't have any custumers anymore .. the rate you ask is for a mid level IT guy in Belgium ..

    • @Jack-hu7cb
      @Jack-hu7cb 4 ปีที่แล้ว +2

      I think people think the expensive contractors are ripping them off. It’s hard to find a balance between paying the least you can but still getting a good job done.

    • @Marco-mg9tv
      @Marco-mg9tv 4 ปีที่แล้ว +5

      Yah right so you basically charge 1000 uros a day fair play mate. Bullshit right there

  • @sprax112
    @sprax112 4 ปีที่แล้ว

    I have never in the history of having a TH-cam channel liked a video with in the first two seconds, you poor bastard haha! All the best bud!

  • @chrisdorrell1977
    @chrisdorrell1977 3 ปีที่แล้ว +2

    Not only informative but comedy aswell!! Liking the channel 👌

  • @EruElectrics
    @EruElectrics 4 ปีที่แล้ว +22

    A minimum of £200+VAT for an EICR in London I think is a bit cheap. To be honest I'd expect someone like you to have much better prices. Maybe that's why you end up working 12 hours, 6 days/week.
    I charge a minimum of £215+VAT at North Kent, losing more that I win but I didn't start my own business to work around the clock for stupid prices.

    • @kevinwhite2380
      @kevinwhite2380 4 ปีที่แล้ว +2

      I agree. I'm in Hertfordshire & may quote up to £300+ for some installation!! Depends on age, complexity, access, upgrades, etc...

  • @graemetaylor8933
    @graemetaylor8933 3 ปีที่แล้ว +1

    1st one of your videos I've seen, brilliant - informative & damm funny, pricing very interesting, too many people wanting us to do an EICR for under £100, all they want is the paperwork with our name on it

  • @TYLERCONSTRUCTION
    @TYLERCONSTRUCTION 4 ปีที่แล้ว

    Eicrs are a absolute bummer. Keep up the good work tom 👍👍👍❤️❤️

  • @Graeme566
    @Graeme566 4 ปีที่แล้ว +25

    Tom: how I do EICR testing
    Door: Lol, hello

  • @hasibazad7320
    @hasibazad7320 3 ปีที่แล้ว

    The first video that I liked in your entire videos because in this vide you actually tackled on showing stuff and doing stuff and elaborate things instead of talking off the topic . As usual you do lol , if you continue like this video you find another fan 👍

  • @johnyearsley7970
    @johnyearsley7970 4 ปีที่แล้ว +1

    Absolutely brilliant, you should be on stage thought you were so funny and the lid falling on you head I laughed so much. John

  • @richardemery9911
    @richardemery9911 2 ปีที่แล้ว +4

    Good to see your charging sensible rates for a comprehensive test and inspect.. those companies out there charging £85 - £100 plus the vat for testing upto 10 circuits are seriously undermining the Quality Sparkies out there.. I recently re tested a 2 bed flat which had an EICR done. Satisfactory report issued . I found 3 C1s without even trying and 5 C2s. The worst being 2 junction boxes in the loft space with no lids on. A 32 amp cooker circuit still in use but spliced into with a connector block to also run a 7.5 KW shower no RCD insight. After giving the landlord the bad news. He said that the so called test engineer was only there for 45 mins and didn’t even look in the loft space. Luckily he hadn’t paid the bill for that test.

  • @114hours
    @114hours 3 ปีที่แล้ว +3

    My stomachs in agony and I’m fucking crying with laughter at that end bit. The whole timing of that clusterfuck is amazing 🤣🤣🤣🤣

  • @matt92h
    @matt92h 4 ปีที่แล้ว +29

    I wonder if those closet lights turn off when you shut the door.

  • @lonewolfgeoff
    @lonewolfgeoff 4 ปีที่แล้ว

    good vid! hope your heads better tom!

  • @Dornacgove
    @Dornacgove 4 ปีที่แล้ว +45

    Who's saying I watched the door fall several times in slow mo and laughed like a crazy person? Because I definitely didn't!

  • @ryanhamdy9244
    @ryanhamdy9244 3 ปีที่แล้ว +15

    Hi Tom, love watching your videos especially this one, my pricing is pretty much the same as yours mate, I charge £18.50 per circuit and £60.00 for the report. I was debating with myself as to whether I should lower my rates due to all other companies coming in at £100 or less but I’m glad you have spoken about this and I have decided fuck it! if anything my rates should be going up. Any how keep up the good work mate and you never know our paths may cross as you work in the same areas as me. 👍

  • @metproltd
    @metproltd 4 ปีที่แล้ว +2

    Great video - hope your head's okay!

  • @neilbridgeman7768
    @neilbridgeman7768 4 ปีที่แล้ว

    Excellent coding video. Objective and looking at actual risk using severity and likelihood. 👏👏

  • @Rose.Of.Hizaki
    @Rose.Of.Hizaki 4 ปีที่แล้ว +11

    Tom: "Good Afternoon..."
    Door: *_"let me introduce myself"_*

  • @paulwilson3759
    @paulwilson3759 3 ปีที่แล้ว +4

    Hey Tom, just stumbled across you (big Clive recommendation), love your thoughts on EICR pricing, I shall be adopting it too (Hampshire based so might have to shave 10% off). I"ve re-watched from 18.01about 20 times........ and for that alone I'm subscribing. Keep it up!

  • @Redcricket65
    @Redcricket65 4 ปีที่แล้ว +20

    8 hours ealier... That hatch knocked the r out of the word too 🤣🤣❤️

    • @dast_uk
      @dast_uk 4 ปีที่แล้ว

      First thing i spotted haha

  • @chiefpilot5383
    @chiefpilot5383 3 ปีที่แล้ว

    You are the Gordon Ramsey of Sparks! Great video just made me realise I need to up my prices!!! Thanks Tom
    Regards
    Gareth

  • @peterg.8245
    @peterg.8245 4 ปีที่แล้ว +1

    I love how any object can be turned into a cutting insult by putting proper before it.

  • @waynebennett8640
    @waynebennett8640 4 ปีที่แล้ว +2

    Doing my 2391-52 next month, thanks for the heads up with the codebreakers book. I will not be signing any installations for £100. Having a laugh, what's the point! I agree with your way of pricing or it's just not worth doing 👍. Great video Nagy

  • @twowheel_enthusiast5925
    @twowheel_enthusiast5925 4 ปีที่แล้ว +1

    With regard to your pricing it only seems expensive due to the individuals willing to do an EICR for £100 then proceeding to do 6 in a day. Im a Glasgow company and for a new domestic property we have not tested before its £30 per circuit, for that you are getting an incredibly in depth inspection. Inspections thereafter we reduce to £25 per circuit as we know the installation has been brought up to standard and testing is much more efficient.
    Alot of the reasoning behind people thinking £300+ expensive is that they do not understand what a proper EICR is, that also goes for the Electricians carrying them out.
    Its almost a box ticking exercise and it is something which needs to be addressed. The sheer amount of EICRs i have carried out, signed off by someone else not even 1 year prior and they fail after opening the first socket or light fitting.
    Keep up the good work and keep driving home the importance of a good electrician. Its great to see, I have many of the same traits as you with regard to doing things the absolute correct way every time and no hash bash shit 👌

  • @soundmangaz6833
    @soundmangaz6833 4 ปีที่แล้ว +48

    Little switch on the door frame that turns the lights on whenever the door is opened?

  • @killerkhan
    @killerkhan 3 ปีที่แล้ว +3

    Just started doing EICR's, It takes a longer than people would think. It's hard coding something as C2 or C1 because the landlord always argues it, then the estate agents get a bit annoyed. They never accept that they have get a new consumer unit. Also the estate agents bring us down to a ridiculously low price.

  • @zabizeyaee8002
    @zabizeyaee8002 3 ปีที่แล้ว

    You can use circuit finder or tracer kit or simply a toner to find a buried switch if there is any for those lights that are on all the time.

  • @shaunpridden5806
    @shaunpridden5806 4 ปีที่แล้ว

    We have set charges based on the size of the property. 1 Bed up to 5. Anything over that is done on a price per circuit. Sticking point there is we could get a 1 bed with 10+ circuits but then get a 3 bed with 3/4 circuits. Swings and roundabouts I suppose but I do like the way you price yours. Something to think about 👍

  • @anthonysykes542
    @anthonysykes542 2 ปีที่แล้ว

    You just earned a sub! Great intro and outro to the video lol

  • @callamtaylor387
    @callamtaylor387 4 ปีที่แล้ว +34

    Never a C2 just because of stairs, I thought we code things for electrical safety I.E potential of causing death or harm through electric shock? C2 potentially dangerous under fault conditions.

    • @nathansheargold5413
      @nathansheargold5413 4 ปีที่แล้ว

      Old firm i worked for would always c2 any non metal fuseboard under a stair case, even if it was dual rcd and they both worked fine. They said needs to be fire rated for staircase due to it being a fire escape, sometimes I was changing fuseboards that were less than a year old

    • @stuarnold7338
      @stuarnold7338 4 ปีที่แล้ว +1

      If you used a C2 because of only one RCD on a multilevel property you'd have to C2 on a split board in a property with only one lighting circuit.

    • @zjzozn
      @zjzozn 4 ปีที่แล้ว +2

      Open your mind and eyes 😳

    • @fumthings
      @fumthings 4 ปีที่แล้ว

      @@nathansheargold5413 genuine question, did they not have fire retardant plastics then?

    • @TheChipmunk2008
      @TheChipmunk2008 4 ปีที่แล้ว +1

      @@nathansheargold5413 That's why I'm self employed... crap like that makes me mad. I WILL argue the toss with a boss that he or she is WRONG

  • @davidb3537
    @davidb3537 4 ปีที่แล้ว +8

    Hi Tom,
    Great video, couldn't agree more with going by gut feeling, it comes with experience.
    I like that you sort of promoted the NAPIT code breaker book, it's about time that a decent guide was produced, it will help create some uniformity in EICR observations.
    I use mine to back up my observations to the client, they can't argue if its printed in black and white.

  • @Mark1024MAK
    @Mark1024MAK 3 ปีที่แล้ว +6

    On the lighting question, how does a BC or ES lamp holder ever pass this kind of inspection? No tools required to expose live conductors… Lamp easily removable by the user…

  • @DoktorKoch
    @DoktorKoch 3 ปีที่แล้ว

    Hi, excellent video!
    Quick question: I am having a periodical electrical checks done by my local council. I have some heavy furniture with lots of stuff covering some sockets which will be a pain in the proverbial to move around: Two of the sockets are switched off (and never used) and the other two sockets have extension cables running behind the furniture. Will I need to remove to furniture to access the sockets I use, or can you do a test just using the sockets on extension cables? Thanks

  • @jacekwojnarowski8597
    @jacekwojnarowski8597 4 ปีที่แล้ว

    😂😱sorry Tom looks like your gut feeling was spot on....big thumb up as you are honest and talk about £££ , this really helps break the Taboo

  • @TheYohtube
    @TheYohtube 4 ปีที่แล้ว

    Hey Tom great video as always...is that NICEIC Software your using an offline version or the normal online version.???

  • @leebutterworth7465
    @leebutterworth7465 4 ปีที่แล้ว +1

    Tom great video as usual, But why did you think it was safe to stick your pinky through the hole in the base of that upstream RCD when the main fuse was still in and no proof of safe isolation
    the upstairs dressing room with the lights on was it not switched on the door casing with a microswitch???

  • @michaelsands6738
    @michaelsands6738 3 ปีที่แล้ว

    The bump on the head 😂😂😂 I missed that the first time I watched and you cursing £100 EICR 😂😂😂

  • @sheargillsparkie9588
    @sheargillsparkie9588 4 ปีที่แล้ว +1

    Flipping heck, I felt that. I had the exact same thing happen to me during an eicr! Only the door was twice as thick. You suffer concussion as a result. Blooming painful.

  • @benevison7434
    @benevison7434 4 ปีที่แล้ว +3

    Fan isolators not required if a window installed. That’s in electricians house to building regulations. However manufacturer probably states isolator.

  • @masomadanish2961
    @masomadanish2961 3 ปีที่แล้ว +2

    Great video n honest guy..

  • @MH-bv9kk
    @MH-bv9kk 4 ปีที่แล้ว

    17:55 - How every Monday feels to me.
    Hope your tomorrow is better.

  • @nigel1964
    @nigel1964 4 ปีที่แล้ว +7

    And the lemon was holding the string attached to the wood which he pulled on and OUCH!!

  • @nicwhite1568
    @nicwhite1568 4 ปีที่แล้ว +2

    £30 per circuit, no extra for Db. C2 for downlight becomes dangerous when someone pulls it out the ceiling, C3 for dB not fire rated in domestic premises and a rental. Personally I would recommend dB with split or rcbo type.

  • @doctorelectric470
    @doctorelectric470 4 ปีที่แล้ว +8

    For a regular domestic property I charge £300, I win about half of them but it will take me a full day to test a property fully

    • @andytap560
      @andytap560 3 ปีที่แล้ว +1

      Completely agree i always book a half day minimum or full day

  • @theeamesfamily5791
    @theeamesfamily5791 4 ปีที่แล้ว

    Great video mate 👍👍

  • @davey6024
    @davey6024 4 ปีที่แล้ว

    Exactly same tool set for me including the Larry apart from i use long nose not snips for removing cables out of tight boards for testing.

  • @shamyyy1
    @shamyyy1 4 ปีที่แล้ว

    Makes it so much more hilarious that you were calling him a lemon and a spanner before it fell on your head 😂😂

    • @stuarnold7338
      @stuarnold7338 4 ปีที่แล้ว

      He was listening and used his voodoo magic on Tom.

  • @TheChipmunk2008
    @TheChipmunk2008 4 ปีที่แล้ว +12

    The codebreakers book is wrong on a few things
    Example, Front end RCD is fine, regardless of safety ... if 'potential to cause danger' is a C2, every house in the UK would get a C2. Lampholders can give one a belt...
    We tend to do lots of C3's and only C2 or C1 things that are likely to be causing problems ELECTRICALLY. Someone falling down the stairs isn't an electrical issue and has no place in an EICR
    Linked main switch is a C3 fo sho.
    Not sure the downlight would be a C1 for me... I'd call it a C2. I'd say inner core is 'the copper'
    not the insulation.
    And the coding of non fire rated downlights with a room above is one example of where the book is heinously WRONG. Not required unless it's a separate fire compartment, so no code at all.
    And all my disagreements above notwithstanding, we've been called to look at EICR 'unsatisfactory' results by landlords... and have ALWAYS agreed with the original inspector. We've downgraded a couple of C1's to C2's, but that's still the same ultimate result

    • @asherrose4114
      @asherrose4114 3 ปีที่แล้ว +1

      Is it still worth buying tho?

  • @chirsrussell2468
    @chirsrussell2468 4 ปีที่แล้ว

    In the walk in could you not fit a door switch or is there one fitted after the unstitched fused spur ?!

  • @georgejexter
    @georgejexter 4 ปีที่แล้ว

    Tom what software do you use to edit your videos ??

  • @teamsjonline
    @teamsjonline 3 ปีที่แล้ว +3

    Cor, and I thought I had a bad day trying to find a fault on a ring, least I didn't have a door fall on me!

  • @throttlebottle5906
    @throttlebottle5906 4 ปีที่แล้ว

    the start and clunk on head.. yep, we've all done it and we all still do, I still bounce head off things on the regular, breaking glasses/spectacles often.

  • @ndelockedout
    @ndelockedout 3 ปีที่แล้ว

    Hi Tom
    I’ve been out of electrical work for a few years due to working on the dark side (gas) and plumbing
    I’m now being asked by the landlords I work for to do eicr’s
    It makes sense that I do both as I’m there already to do the gas etc.
    My other half’s cousin has recommended the nap it code breakers book so I have one on the way..
    Good to know your take on pricing as I wouldn’t have had a clue.
    Basically do you have a pricing guide for other stuffed ? or do the guys on here refer to anything that is a rough guide to fair/reasonable pricing?

  • @ghostfox3560
    @ghostfox3560 4 ปีที่แล้ว

    Home Medical Equipment. Like oxygen condensers and other devices would upgrade a c3 to a c2 or a c1 with that board?

  • @creativejamieplays7185
    @creativejamieplays7185 4 ปีที่แล้ว

    Cupboard door is a C-10. (And that's a minus not a hyphen). Improvement recommendation: Hydraulic thingy you get on a boot.

  • @markobrien7802
    @markobrien7802 4 ปีที่แล้ว +2

    F**k of a thing to happen when you are not expecting it. Hope you are ok!!
    On the EICR... We have them in Ireland too but we have a set list of questions to answer. You also have space for test readings etc. I'll send a copy of one to you if you are interested in taking a look to compare!

  • @asdreww
    @asdreww 4 ปีที่แล้ว

    is an EICR what you need if you have an extension with wiring that was never registered with building controls, just to check it's safe?

  • @calumclark1719
    @calumclark1719 4 ปีที่แล้ว +4

    That cupboard lights I came across something similar. On a periodic inspection i put it down as a c2 but strongly advised it to be changed which they agreed too.
    I charge my hourly rate and it takes as long as it takes for the testing 🤷‍♂️
    As for the client that you dont want to go back always trust your gut i completely agree

  • @DWAIN61
    @DWAIN61 3 ปีที่แล้ว

    In domestic propertys I don't think it is requied to have a local switch for a fan, possibly a shower as well as the circuit breaker provides that function.

  • @marktaylor7288
    @marktaylor7288 3 ปีที่แล้ว

    C2 for the spots, not immediate danger as you would have to pull the fitting down to get access for live parts

  • @Namirred
    @Namirred 4 ปีที่แล้ว

    Is the cupboard door classed as c1 or c2? Hope you are ok.

  • @paulmerchant9015
    @paulmerchant9015 4 ปีที่แล้ว +28

    If front end RCD trips with correct times then C3 and if not then a C2.

    • @RubenKelevra
      @RubenKelevra 4 ปีที่แล้ว +2

      No it's not. It shuts off the lights in the staircase, that's an issue when there's a fire. You have either battery backup on the lights per floor or you have to isolate the lights from the rest of the fuseboard.

    • @anoniemous2136
      @anoniemous2136 4 ปีที่แล้ว +2

      I would agree with Paul, I don't think that the argument about it shutting off the lights is enough because from my experience the power goes out more than an rcd trips and even if it trips then it's only possible that there will be no light (I'm assuming that there are windows in the house). Also on top of that the likelihood of someone tripping down the stairs in their own home even when it's dark is low. Now because we are talking about things with really low chance of happening are we going to consider other rare occurrences like the rcd failing closed.
      About the fire comment Ruben, I'm not sure what its like where you are but here the fire brigade shuts the power off from the street and what's to say that the fire won't damage the lighting circuits first?
      I think because of how unlikely it is that the rcd will trip this situation will generally be a C3, however one should take into consideration other factors like the age/health of the residents and the condition of the rest of the house and if there is an elevated risk of the rcd tripping and causing injuries in that specific building then classify it as a C2.

    • @tobysherring1369
      @tobysherring1369 4 ปีที่แล้ว +7

      You could argue about lights on stairs as a danger for thousands of older properties. But even with split RCD board, the light on the stairs could go off (blown lamp, circuit fault, nuisance trip, another circuit on same RCD is faulty). Even an RCBO could trip and leave you in the dark. The safety clause is about electrical wiring, not any possible imaginable scenario. A tenant could take off a faceplate and stick their hand in, but we're not going to code every faceplate as a C2.

    • @tonywainwright30
      @tonywainwright30 3 ปีที่แล้ว

      @@tobysherring1369 Exactly!

    • @jimmylovescake6813
      @jimmylovescake6813 3 ปีที่แล้ว +1

      @@RubenKelevra how many domestic properties have battery backups in lights, beyond communal?

  • @g.williamswilliams8442
    @g.williamswilliams8442 3 ปีที่แล้ว

    Good video mate.
    I'm surprised that you didn't raise the MET , the earthing clamp on the incoming cable sheath ?
    Thoughts please.

  • @lukebeaney4327
    @lukebeaney4327 4 ปีที่แล้ว +1

    I like your videos and drop in every so often for a watch and the ending to this video was brilliant Lol
    Mugging the Lemon off then boom! You got fully Karma'd right on the swede 😆😆😆😆

  • @rogerbean393
    @rogerbean393 4 ปีที่แล้ว

    So appreciate it’s a short video but what percentage do you check on each circuits ?
    At £20 a circuit what do you get ? Or are you just doing a visual at this point as you have said you don’t need your tester ,a bit of a surprise !

  • @harrymcough5545
    @harrymcough5545 4 ปีที่แล้ว +1

    I actually LOLed when he called that guy a lemon lol. That's seems like good pricing tbf .my mate charges 140 for a small place.

  • @callummcivor1094
    @callummcivor1094 4 ปีที่แล้ว +14

    Hope you are okay after that

  • @michaelviney3737
    @michaelviney3737 3 ปีที่แล้ว

    Very interesting to get your approach to doing EICR. There is a balance to be reached on how items are inspected but in all cases it is to do with electrical safety only. Ie all your C2 vs C3 examples can only be C3. Falling downstairs etc is not relevant. Safety wise nothing wrong with a board of breakers and external RCD in it’s day and it is still not electrically unsafe today. But then what do I know? I completed my 5 year apprenticeship with the electricity board 60 years ago!! I think your pricing is about right ….4 hrs to do it properly

  • @7chappers
    @7chappers 4 ปีที่แล้ว +2

    Sorry man. Have to say I did watch the end about 6 times 😂 hope you’re good

  • @PJB71
    @PJB71 4 ปีที่แล้ว +12

    C3 upfront rcd, C2 downlighters connections as they are not accessible, installed within the ceiling, C3 for non fire rated downlighters. Unless it was actually a fire rated ceiling. Napit code breakers does have errors, ie, cables in wall without rcd protection C2 is an error. I looked at an recent EICR on saturday completed by another electrician with his quotation for remedial’s. (The client wanted alternative quotes). The remedial’s were in excess of £1k, after reading the report & visiting the property, no remedial’s were required, the client is not happy. You can yourself into deep water if your not sure what your doing or just giving your personal thoughts on an EICR. The majority of the time you have to use your common sense & engineering judgement. We would all love to replace that old 3036 board. We can all make recommendations, but they are purely that recommendations. Pricing, if you want to do an EICR for silly low price & not inspect & test the property properly if something happens it will come back to bite the spark who signed that report. You cannot sample everything, but samples should be completed, if there are loose connections (C2), sort them out later.👍🏼

    • @Adit209
      @Adit209 4 ปีที่แล้ว

      Spot on mate, I’m in agreement with everything you have said, regarding the downlights and regarding other sparks remedial work lists. I’ve had one recently C2 for 6mm main bonding, C2 for plastic DB, C2 for no RCD (even though it’s a first floor flat) the list goes on. We should all know these aren’t C2s but some sparks are either ignorant or simply trying to rip people off.

    • @AdrianColes
      @AdrianColes 3 ปีที่แล้ว +2

      Don’t the downlights become accessible when you have to change a bulb??

  • @davewright22
    @davewright22 4 ปีที่แล้ว +2

    Your pricing is very accurate

  • @pulseelectrical595
    @pulseelectrical595 4 ปีที่แล้ว +6

    Hello Tom! Pulse boys here! North London based.
    Our Charges:
    £70per board.
    £25per circuit.
    +Parking
    +Vat
    Possibly do a small discount if board has more than 10 circuits.

    • @rogerbean393
      @rogerbean393 3 ปีที่แล้ว

      What percentage do you check of the install.
      Hopefully you take a meter unlike Naggy !

  • @phillgaming
    @phillgaming 4 ปีที่แล้ว

    Hey tom got a question for you mate. What got you into doing self employing just wondering.

  • @jmohammad3762
    @jmohammad3762 4 ปีที่แล้ว +2

    Like you pricing Tom. Unfortunately I don't have clients like yourself my clients cry and whinge for £150 saying I'm too expensive. And I do them according to guidance note 3 no short cuts. Wish you best of luck if your getting that sort of money.

  • @bobbobby5724
    @bobbobby5724 4 ปีที่แล้ว

    Love love you videos Tom

  • @abrael333
    @abrael333 4 ปีที่แล้ว

    does the customers certificate have these codes on it.... how do they know what the problems are? if its codified..

  • @fiveminuteman
    @fiveminuteman 4 ปีที่แล้ว

    What year did the EICR test come in?

  • @daveaustin53
    @daveaustin53 4 ปีที่แล้ว +3

    If there’s ever a danger from lights failing (customer responsible for risk assessment), then surely the remedy is an emergency-type fitting. The cause of the power failure - RCD, MCB, power cut etc. - is besides the point.

    • @tonyyoung3437
      @tonyyoung3437 4 ปีที่แล้ว

      TT earthing systems have RCD protection for all circuits !!!

  • @LordClunk
    @LordClunk 4 ปีที่แล้ว +4

    Did you try shutting the door to turn the lights off in that cupboard? I only ask as I once had a house where a cupboards lights would come on when the door opened.

    • @zjzozn
      @zjzozn 4 ปีที่แล้ว

      It’s a trap 😂

  • @allahdittababu4802
    @allahdittababu4802 4 ปีที่แล้ว +1

    Keep safe dude, just thought of your face going into an open live consumer unit ... Thank God your okay ... just one of those days man rest up 😑

  • @reeceyp1972
    @reeceyp1972 3 ปีที่แล้ว

    Hi, which wera set, do you use?? And how have they lasted? Cheers

  • @Marty7787
    @Marty7787 4 ปีที่แล้ว +1

    LMAO!! Great start to the video.

  • @mintsauce563
    @mintsauce563 4 ปีที่แล้ว +1

    Those cupboard lights not on a door frame switch?

  • @farring14
    @farring14 4 ปีที่แล้ว +1

    I’m afraid I did 😂 when door fell after calling the bloke a proper lemon. Fire rating of down lighters, there are a number of factors I’d consider but if it’s within the confines of a purpose flat it’s self then possible no need, if it’s a pre 85 conversion then possible yes. Down light wiring, I’d suggest c1 no tools needed to change the light bulb and potentially exposed to bare wire.

  • @user-xv6um9nr3z
    @user-xv6um9nr3z 3 ปีที่แล้ว

    Hey Thomas been subscribed for a while now. I've completed the pre apprenticeship course in electrical installation with a perfect record but can't even get a reply from contractors about jobs. Any suggestions to give me an advantage when sending off my cv? Based in Glasgow if that matters, cheers!

  • @AndyNichol
    @AndyNichol 3 ปีที่แล้ว +1

    That was the funniest ending i watched it about 5 times.

  • @shaunsparky5354
    @shaunsparky5354 4 ปีที่แล้ว +6

    Hey Tom, great to see how you approach an EICR.
    Just a point on the 'Linked Main Switch', are we not talking about switching of both L and N and not a 'Single Point' of Isolation? Totally different issue!
    Loving your honesty online. Hope you don't take offence to my comment .
    PEACE Bro ✌.

    • @rogerbean393
      @rogerbean393 4 ปีที่แล้ว

      Yeah clarify please.
      I assume the old Wylex had double pole main switch but the board below only had a RCD to cover the 2 circuits,so no main switch to isolate both live conductors.

    • @tomorichard
      @tomorichard 4 ปีที่แล้ว +3

      Roger Bean the rcd in the bottom board would most certainly also be double pole.

  • @sean1325
    @sean1325 2 ปีที่แล้ว +1

    Best ending to a video ever that yerno your reaction I'm crying hahahaha 🤣🤣🤣

  • @berenlea486
    @berenlea486 4 ปีที่แล้ว

    Are these prices in top of your hourly rate or is it a fixed price to do that job

  • @e5Group
    @e5Group 4 ปีที่แล้ว

    Loving this👍

  • @murtazahussain4054
    @murtazahussain4054 3 ปีที่แล้ว

    I got a EICR for £80. should each circuit be tested individually? because my electrician just had a print out of some numbers which he wrote down on the certificate. (this electrician also changed the consumer unit)

  • @cjmillsnun
    @cjmillsnun 4 ปีที่แล้ว +2

    Lack of discrimination on RCD protection as shown is C3. By risk of danger, they are referring to risk of shock.

    • @shorty57red
      @shorty57red 4 ปีที่แล้ว +1

      Just redone my 18th edition We must not use discrimination anymore we now have to use selectivity to be politically correct.

  • @kevinwhite2380
    @kevinwhite2380 4 ปีที่แล้ว

    Is that a Single Phase or Three Phase supply - I can't quite see?? Also, has the Neutral(?) (Centre or Right??) Got a removable or Fuse Link?? - Might require the supply to be upgraded ??