Very well explained. bro
Hi can I ask what is the outlet you used to connect the Hi link mini isolator to the water pump?
Great video! By the way, what modules did you use to connect arduino to SSR? Thank you!
1/5/10pcs LM2596 DC to DC Buck Converter 3.0-40V to 1.5-35V Power Supply Step Down Module
s.click.aliexpress.com/e/_De9k5ZT
one 1 channel relay module DC 5V 9V 12V 24V high and low level trigger relay control with optocoupler red
s.click.aliexpress.com/e/_DlQBD93
AC-DC Power Module Mini Isolation Switch Power Supply Module 220v to 12V/5V
s.click.aliexpress.com/e/_Dejcv9F
s.click.aliexpress.com/e/_DnKTkCN
A Relay module was not used in this circuit . We direct drive from Arduino Nano.
Hi I did everything right but when I plug the water pump the arduino doesnt have power
What to do if current consumption of relau is higher than 40mA?
Arduino can't drive relay .You must use driver circuit that can supply current over 40mA.
Hi, can you tell me how to make a module for 3 phase 3kvar capacitor switching with timers to on and off at given time?
Are you making the Power Factor Correction circuit?.Please tell my about your project.
@@MrProjectTSE Hi, yes my project is based on pf correction, but to a specific 3 phase ac load. I'm currently stuck at this project. Basically I have a 5hp 3 phase submersible motor, which pf is lagging. As I have only one motor load, 1 three phase capacitor(2kvar or 3 kvar) is sufficient. Now I want this capacitor to be operated after a min once the motor complete its flc when turned on anytime. Like a delay switch of 1 min to a capacitor makes sense, but can't able to progress in this project, any help from you is greatly helpful. Hoping a reply soon with a solution for my problem.
Thanks and regards 😊.
@@MrProjectTSE and forgot to say, I only have 3 phase supply r,y,b from the transformer with no neutral.
what wire did you use to connect the ssr and Hi link mini isolator to the ac? did u plug it in into the convenience outlet?
Great! by the way do the the Mini isolator connected to the AC paired with the excess wires on the Motor and relay?
I have to apologize,
the relay was used for another project, but I didn't remove it
The relay that you saw, I didn't use it
the connection of the Hi link mini isolator was both AC connected to the AC source of the motor?
Usually, Hilink will isolate the AC from the DC side, You can use the same AC supply as the motor.
However, to be sure you should check the isolation of the power supply. @@johnreyespano8346
what is the material called in inserting the pin of Hi link isolator that attached with the wire?
Can you give me the schematic diagram for this sir? Thank you
I post a picture diagram at the community: www.youtube.com/@MrProjectTSE/community
Amazing, how about the collapsing emf from the motor sir, would it not be harmful with the ssr? Did you put some back emf protection in the ckt? Thank you so much..