PAANO MAG INSTALL NG AIRCON OUTLET./TUTORIAL.

แชร์
ฝัง
  • เผยแพร่เมื่อ 20 มี.ค. 2022
  • PAANO MAG INSTALL NG AIRCON OUTLET./TUTORIAL.
    / saydetv
    how to install aircon outlet,aircon outlet,paano mag install ng aircon outlet?,paano mag install ng aircon,paano mag install ng aircon?,paano mag install ng panel board,aircon outlet installation,paano magkabit ng outlet sa aircon,pano install aircon outlet,paano magcompute at maglagay ng aircon outlet,paano mag wire ng aircon,one gang aircon outlet,how to install 1 gang aircon outlet,how to install aircon,how to install outlet from aircon

ความคิดเห็น • 192

  • @Mosurael143
    @Mosurael143 ปีที่แล้ว +2

    Thank you sir

    • @SAYDETV
      @SAYDETV  ปีที่แล้ว

      Welcome po salamat.

  • @mellivebrown28
    @mellivebrown28 ปีที่แล้ว +2

    Ang galing idol! Thank you for sharing! Subscription done!

    • @SAYDETV
      @SAYDETV  ปีที่แล้ว +1

      Thank you for watching sir, god bless.

    • @mellivebrown28
      @mellivebrown28 ปีที่แล้ว

      @@SAYDETV You're welcome my friend! Stay connected!🙏❤

  • @Niotoan793
    @Niotoan793 5 หลายเดือนก่อน

    Salamat po idol

    • @SAYDETV
      @SAYDETV  5 หลายเดือนก่อน

      You're welcome thank you ❤️

  • @bycutgunthe6327
    @bycutgunthe6327 หลายเดือนก่อน

    Nice👍

  • @jayson9974
    @jayson9974 2 หลายเดือนก่อน +2

    Boss question po. Napansin ko kasi ung Copper Tube Pipe ng split type carrier aircon ko sa labas is super dumi na. Ayun pala kinakapitan ng dumi kasi madalas basa at mejo nag yeyelo. Concern lang po ako, may bad effect po ba yon sa aircon ko? If meron po ano po ung possible ma damage sa aircon ko if ganon. Thank you boss in advance

  • @marilynsanchez2655
    @marilynsanchez2655 ปีที่แล้ว

    Boss nalilito aq sa demonstration mo..dapat ang live sign sa breaker don ilagay ang hot wire mo ang neutral nmn sa right side..hinde pwd mag ka baliktad

    • @SAYDETV
      @SAYDETV  ปีที่แล้ว

      Hindi ko po magets ang tanong mo sir, pwede po magkabaliktad ang neutral at live.

    • @jaydenustares785
      @jaydenustares785 ปีที่แล้ว

      Oo nga haha...

  • @jpmanhuaupdateTV
    @jpmanhuaupdateTV หลายเดือนก่อน

    Boss pwde ba mgkconnect Ng supply sa existing wall outlet?

  • @YourLocalCuboidShape
    @YourLocalCuboidShape ปีที่แล้ว

    Galing po... May tanong lang po ako, wala kasing saksakan ng aircon sa kwarto ko po at ang breaker ay nasa first floor pa. Ang sabi sa akin ng electrician mag tap daw sila sa isang outlet. Ok lang po ba yun? .75 lang naman ang aircon

    • @SAYDETV
      @SAYDETV  ปีที่แล้ว

      Pwede naman po yan kaya lang maaapektuhan yong ibang gamit o appliances nyo na connected dyan sa pagkukuhaan nyo na outlet kung mag automatic on and off ang aircon mo. Dapat po may sariling breaker ang aircon.. salamat po.

  • @jmjz3488
    @jmjz3488 ปีที่แล้ว

    Swabe. 👊👊. Boss pwede ba mga 2 meters ang gap ng CB at outlet?, bali 2 meter wire from CB to outlet. Mostly kasi nakita ko nasa tabi lang yung CB at outlet. Thanks po

    • @SAYDETV
      @SAYDETV  ปีที่แล้ว

      Pwede po kahit ilang meters depende sa gusto mo at sa location ng breaker at outlet.

  • @realisticph5233
    @realisticph5233 9 หลายเดือนก่อน

    Boss good day,ask ko lang oks lang ba na 15A ang cb ko para sa 1HP AC?at yung distance ng aircon ko to main CB e aabutin ng 8meters.oks lang ba na ang mahaba wire from separate breaker papunta dun sa mismong aircon?tap ko sa main

    • @SAYDETV
      @SAYDETV  9 หลายเดือนก่อน

      Ok lang yan kung yan lang ang available mo na breaker kaya naman yan, piro mas maganda kung 20A.

  • @colostomyfriends6673
    @colostomyfriends6673 7 หลายเดือนก่อน +1

    Boss SAYDE TV, Pacensya na sa tanong, nung inistall mo ang wiring ng circuit breaker at ang saksakan, paano ang safety dahil diba live wire at paano mo naiwasan hindi makuryente, Pacensya na sa tanong ako po ay 19 year old po nag aaral paano ikabit ang safety breaker

    • @SAYDETV
      @SAYDETV  7 หลายเดือนก่อน

      Para safe pag gumagawa tayo mas maigi ns e off natin ang main breaker ng pagkukuhaan natin ng supply, at kung mag tapp naman tayo ng live kailangan naka safety gloves tayo at don lang tayo hahawak sa insulator ng wire iwasan natin mahawakan yong wire na wala ng balot, at kung wala nman tayo gloves iwasan lang natin na mahawakan ang live wire don lang tayo humawak sa insulator.

  • @cedrickfabila5235
    @cedrickfabila5235 ปีที่แล้ว

    Sir tanong lang pwede po ba mag top ng extension para sa isang ilaw at isang electrifan sa breaker ng 0.6hp aircon? na 30amp.

    • @SAYDETV
      @SAYDETV  ปีที่แล้ว +1

      Pwede piro kukurap ang ilaw pagnag automatic ON and OFf ang Aircon.

  • @jackofalltrades7786
    @jackofalltrades7786 ปีที่แล้ว

    Lods ano ba maganda gamitin sa aircon magnetic switch o yang cercuit breaker?

    • @SAYDETV
      @SAYDETV  ปีที่แล้ว

      Circuit breaker po matibay basta match lng sa capacity. Ang magnetic kasi laging naka on ang coil.

  • @kennethdomingo8758
    @kennethdomingo8758 2 หลายเดือนก่อน

    Bos pano po kumuha ng power nakaset napo power nalang po dko po alam san kukuha

  • @jhanpauloferrer9518
    @jhanpauloferrer9518 2 ปีที่แล้ว

    Dapat sinasama nyo ung service entrance ipakita nyo kung paano kinakabit para malaman ng karamihan

    • @SAYDETV
      @SAYDETV  2 ปีที่แล้ว

      Miron po tayo video ng sinassbi nyo po maari nyo po panuorin.

  • @Jedesire_JDR
    @Jedesire_JDR ปีที่แล้ว

    Sir pwde gumamit ng wire color black lagyan ko lang ng marking na green..

    • @SAYDETV
      @SAYDETV  ปีที่แล้ว

      Pwede po yan importante may ground lagyan mo nalang ng level para malaman na ground yan.

  • @micheal5880
    @micheal5880 4 หลายเดือนก่อน +1

    Boss pag walang equipment grounding, gagana parin ba? Bali line and neutral gamitin

    • @SAYDETV
      @SAYDETV  3 หลายเดือนก่อน

      Oo gagana parin yan piro mas maganda lagyan ng ground para sa safety ng aircon at sa gumagamit din pag wala kasi ground wire kung minsa may ground ang body ng aircon pag hinawakan mo

  • @christophermarispalsy6000
    @christophermarispalsy6000 ปีที่แล้ว

    Sir pwede ba mag connect ng extention outlet sa breaker para sabay isaksak ang aircon at cctv?

    • @SAYDETV
      @SAYDETV  ปีที่แล้ว

      Pwede piro ihiwalay mo yong sa aircon kasi nag pagnag-automatic on and off ang aircon kukurap ang cctv mo.

  • @vhencatalino8209
    @vhencatalino8209 10 หลายเดือนก่อน

    Boss,saan galing ang grounding equepment mo sa braeker..

    • @SAYDETV
      @SAYDETV  9 หลายเดือนก่อน

      Galing yan sa lupa o earth ground

  • @naldsiro291
    @naldsiro291 ปีที่แล้ว

    idol pag ang linya sa bahay ay line to line, san ikakabit pag neutral?san ikakabit ang live?or pwede kahit saan na ilagay kase line to line naman ang connection?

    • @SAYDETV
      @SAYDETV  ปีที่แล้ว

      Kung line to line connection po tapos ganyang breaker ang gamit surface type yong dalawang live sa circuit breaker ilalagay ang neutral pwede naka hung lang direct ka lang mag-connect tapos ang grounding para sa equipment ay sa metal case mo na e conect

    • @SAYDETV
      @SAYDETV  ปีที่แล้ว

      Kung line to line connection po tapos ganyang breaker ang gamit surface type yong dalawang live sa circuit breaker ilalagay ang neutral pwede naka hung lang direct ka lang mag-connect tapos ang grounding para sa equipment ay sa metal case mo na e conect.

  • @joeedisonsagon6245
    @joeedisonsagon6245 ปีที่แล้ว

    Gud am sir pareho lng ba sila ng freezer nang wiring t.y

    • @SAYDETV
      @SAYDETV  ปีที่แล้ว

      Oo pariho lang 20A or 30A gamitin mo na breaker.

  • @jhomarleonardo6421
    @jhomarleonardo6421 ปีที่แล้ว

    boss ok lng ba na un sa aircon e kumuha sya ng power supply sa outlet na may ksmang nkasaksak na ref kahit nka 60amper aq sa main breaker?

    • @SAYDETV
      @SAYDETV  ปีที่แล้ว

      Ok lang kasi 60A naman ang main breaker mo piro wag ka dyan mag-connect sa mismong outlet doon ka magtapp sa main na 60A.

  • @DenShuntaro
    @DenShuntaro หลายเดือนก่อน

    boss kaylangan po breaker

  • @marielgabriel3268
    @marielgabriel3268 2 หลายเดือนก่อน

    Sir pede po magtanong..iinstall po kc ac namin na 1hp..may outlet na po sya sa kwarto..ang breaker nya po nasa 1stfloor nakalagay sa panel board 30amp po sya pero kasama po lahat ng outlet sa 2ndfloor sa breaker nayan bale may 5outlet sa 2ndfloor pero hindi nmn po lahat ginagamit..1 aircooler lang po sa kabilang kwarto..ok lang po ba yun oh need pa po bukuran ng breaker c ac?

    • @SAYDETV
      @SAYDETV  2 หลายเดือนก่อน

      Pwede lang yan kaya yan limang outlet lang, piro pagnag auto on/of ang aircon kukurap ang nasaksak na appliances lalo na tv, kaya mas maganda nakahiwalay ang aircon kasi malakas yan. 20A para sa 1hp aircon

  • @kite449
    @kite449 2 ปีที่แล้ว

    Pano po pag nasa 1st floor yung main breaker? Tas sa 2nd floor po ilalagay yung AC?

    • @SAYDETV
      @SAYDETV  2 ปีที่แล้ว

      Maglagay ka lang ng wire pataas papunta 2nd floor tapos sa line side ka ng main breaker mo mag connect ng wire doon sa 1st floor tapos sa taas ka maglagay ng safety breaker sa tabi ng Aircon mo.

  • @leonezacallos9362
    @leonezacallos9362 ปีที่แล้ว +1

    sir submeter gamit pwede po ba submeter to 20amp supply outlet and lights the connect po namin sa 15amp na breaker for aircon ? ir ok lng 2 20 amp nkatop sa submeter

    • @SAYDETV
      @SAYDETV  ปีที่แล้ว

      Ok lng po, 20A sa outlet 15A sa ilaw

    • @SAYDETV
      @SAYDETV  ปีที่แล้ว

      Sa aircon 20A din gamitin mo para sa kanya lang, sa 20A #12 ang wire, sa 15A #14.

  • @ricardopastranajr4010
    @ricardopastranajr4010 2 วันที่ผ่านมา

    pwede po ba isang 30amper na breaker sa dalawang 1hp power na aircon #12 thhn na wire gagamitin

    • @SAYDETV
      @SAYDETV  วันที่ผ่านมา

      Pwede po 👍🏿piro mas maganda 20A tig isa sila

  • @jmexchannel3441
    @jmexchannel3441 10 หลายเดือนก่อน

    kht na tatlo un paa ng saksakan ser kong wala rin nkalagay na earth ground sa bahay. di rin magamit.
    tanong; kong walang earth ground sa bahay. pwd ba lagyan nlng ng wire un mismo body ng aircon at ililibing sa lupa un wire kasama ground rod?

    • @SAYDETV
      @SAYDETV  10 หลายเดือนก่อน +1

      Ganon po ang gagawin kapag walang ground sa mga outlet 👍🏿.

    • @jmexchannel3441
      @jmexchannel3441 10 หลายเดือนก่อน

      @@SAYDETV tnx ser

  • @julyparin4432
    @julyparin4432 ปีที่แล้ว +3

    Sir tanong lang I DIY ko lang Ang wiring Ng ACU ko. Ano ba talaga Ang gagamitin amperes Ng single breaker for ACU? Kasi may naoanood Ako 15amp. Ang ginamit nyang single breaker. At wire size nya is #12. Ang Sa iyo nman 20amp. Ang ginamit mong single breaker. Ano ba talaga Ang safe? Itong wiring ko pala Ang power source ko is kakabit lang Ako Sa existing line. Pki sagot lang. Thanks

    • @SAYDETV
      @SAYDETV  ปีที่แล้ว

      Sabi po ng Philippine Electrical Code (PEC) ang standard breaker at wire ng outlet ay 20A breaker at #12, sa lighting nman ay 15A breaker at #14 na wire. Ang sa aircon nman dahil gagamit ka outlet syempre gagamitin mo ay 20A breaker at #12 na wire, piro yan ay kung ang aircon mo ay 1.5hp pababa, kung 1.5hp nman pataad 30A na breaker at #10 na wire ang gamitin mo, at saka wag ka kumuha ng supply sa outlet dapat sa main breaker, piro kung yang kakabitan mo na outlet ay #12 at mataas nman ang main breaker mo ay dyan kana kumuha piro dapat walang nakaconnect na iba yang aircon mo lang.

    • @julyparin4432
      @julyparin4432 ปีที่แล้ว

      @@SAYDETV maraming salamat.God bless

  • @michaelsamonte9476
    @michaelsamonte9476 ปีที่แล้ว

    sir may polarity ba pag line to neutral yung wire sa outlet? magtatap kasi ako ng breaker para sa aircon..thanks

    • @SAYDETV
      @SAYDETV  ปีที่แล้ว

      Walang polarity yan pwede yan magkabaliktad wag lng magkadikit.

    • @michaelsamonte9476
      @michaelsamonte9476 ปีที่แล้ว

      @@SAYDETV sir may kuryente pa ba khit pinatay ko na sa main circuit breaker?

    • @SAYDETV
      @SAYDETV  ปีที่แล้ว

      @@michaelsamonte9476 wala na yan power pag pinatay mo ang breaker

    • @SAYDETV
      @SAYDETV  ปีที่แล้ว

      @@michaelsamonte9476 wala na yan power pag pinatay mo ang breaker

  • @bebetv8342
    @bebetv8342 11 หลายเดือนก่อน

    Boss paano pag walang grounding tas Yung wire 3.5 ganyan Kasi Yung outlet Ng ref namin okay lang ba yun

    • @SAYDETV
      @SAYDETV  11 หลายเดือนก่อน

      Ok lng nman kahit walang groundings piro pag may ground na ang ref mo pag hinahawakan mo lagyan mo ma ng ground wire, maglagay ka ng wire galing body ng ref mo tapos ibaon mo sa lupa, mawawala na ang ground nyan.

  • @christiandavegonzales7366
    @christiandavegonzales7366 5 หลายเดือนก่อน

    Bosss sana mareplyan nyo ako ok lang ba na kukuha ng 220volts na supply sa junction box para sa circuit breaker ng aircon o direct kO na dapat sa main breaker iisa lang breaker nmin sa bahay e main 30 amp

    • @user-fz8ww4tr4h
      @user-fz8ww4tr4h 3 หลายเดือนก่อน +1

      Mas ok kung hiwalay breaker ni aircon sa mga Convenience outlet at lightings boss

    • @SAYDETV
      @SAYDETV  3 หลายเดือนก่อน

      Mag lagay ka na lang ng isang breaker para sa aircon para nakahiwalay doon ka mag-connect ng supply sa service entrance sa may dugtong, pwede mag tapp don sa junction box piro not advisable pagnag auto on/off kasi ang aircon kukurap ang ilaw at appliances na naka open halimbawa tv.

  • @user-hh6xx4ds4l
    @user-hh6xx4ds4l หลายเดือนก่อน

    Bakit ung live mo hindi Naka tapat ⚡ lightning na symbo

  • @albertempang
    @albertempang 3 หลายเดือนก่อน

    sir, pwde ko ba erekta yung ground wire galing don sa socket papunta sa lupa na may pako don ko ibaon

    • @SAYDETV
      @SAYDETV  3 หลายเดือนก่อน

      Wag pangit tinggnan, sa body ka ng aircon mag-connect ng ground wire tapos sa lupao ibaon

    • @dominicmanubay8875
      @dominicmanubay8875 หลายเดือนก่อน

      ​@@SAYDETV boss pano po pag walang ground? nasa 3rd floor po kasi kami pano po magkaka ground?

  • @aljonabenir4420
    @aljonabenir4420 7 หลายเดือนก่อน

    Boss tanong lang pwedi bang ipagsabay outlet ng aircon at tv sa isang circuit breaker

    • @SAYDETV
      @SAYDETV  7 หลายเดือนก่อน

      Hindi pwede kukurap ang tv pag nag automatic on and off ang Aircon

  • @samdelacerna7518
    @samdelacerna7518 2 ปีที่แล้ว

    Bos saan po naka top yong breaker mo sa galing po ba yan sa panel

    • @SAYDETV
      @SAYDETV  2 ปีที่แล้ว +1

      Galing panel sa line side ng main breaker mo para hindi maapektuhan ang ilaw at outlet pagnag automatic off and on ang aircon kung sa load side mo e-coconnect ana wire.

  • @joey4329
    @joey4329 ปีที่แล้ว +1

    lodi saan galing ung isang wire na green na papasok ng breaker

    • @SAYDETV
      @SAYDETV  ปีที่แล้ว

      Ground po yan direct yan nabaon sa lupa or earth ground, pariho lang yan sila sa neutral connected rin sa earth ground.

  • @nori2598
    @nori2598 ปีที่แล้ว

    Sir totoo po bang hndi dapat kinakabit ang outlet ng aircon sa mismong tabi ng aircon? Dpat daw medyo may distansya. Kc nkakaapekto dw un sa performance ng aircon.

    • @SAYDETV
      @SAYDETV  ปีที่แล้ว +1

      Hindi yan tutuo walang epekto yan sa per4mance ng Air con, nilalagay ang breaker 1 foot beside sa aircon para madali walang sagabal sa pag install at sa pagrepair kung ito ay masisora.

    • @nori2598
      @nori2598 ปีที่แล้ว

      @@SAYDETV sabi na nga ba e parang walang namang kinalaman un. Electrician pa nman ang nagsabi nun. Ok sir madami pong salamat.

  • @carlmasstown1074
    @carlmasstown1074 ปีที่แล้ว +1

    Boss ask lang, may required ba na distance ang Circuit Breaker sa magiging load nya?
    Madalas kasi na nakikita ko ay malapit lng ang CB sa aircon. Paano kung ang CB ay nasa ground floor and nasa 3rd floor ang Aircon? Or nasa same floor pero around 5-8meter ang layo ng Breaker sa AC? Pwede ba yun?

    • @SAYDETV
      @SAYDETV  ปีที่แล้ว

      1 foot po ang circuit breaker behind aircon unit, yon ay kung nasa baba lng ang aircon mo piro kung nasa mataas na level ang pag install ng circuit breaker ay eye sight lng ang taas para hindi mahirap ayusin kung may trouble, karamihan sa nagpapalagay ng aircon ay nasa tabi lng ang circuit breaker ang purpose nila para madali lng ang pag off para daw tipid sa kuryente at saka required din na dapat nakahiwalay ang circuit breaker ng aircon. Thanks po.

    • @carlmasstown1074
      @carlmasstown1074 ปีที่แล้ว

      @@SAYDETV mayroon kasi akong box/panel ng mga Circuit Breaker e may mga empty slot pa naman. Plan ko sana na doon ko ilagay ang 20amp para sa aircon ko na .75hp, para wire na lang ang pagapangin sa loob ng house papunta sa solo outlet ng aircon. Possible ba iyon or may ma break akong rule sir?
      Nasa 5meters ang magiging length ng AWG#12 wire ko simula CB papuntang load.

    • @SAYDETV
      @SAYDETV  ปีที่แล้ว

      @@carlmasstown1074 ok na po yan dahil panel box ang gamit mo at may nakaabang pra sa aircon, yan talaga ang tama nasa panel box lahat ang breaker kailangan sa aircon lng ang 20A na yan sakto lng yan sa .75hp na aircon, yong iba na naglalagay ng breaker sa tabi ng aitcon kagustuhan lng nla yan.

    • @SAYDETV
      @SAYDETV  ปีที่แล้ว

      @@carlmasstown1074 sakto lng din #12 na wire dyan.

    • @albertcalbang3886
      @albertcalbang3886 11 หลายเดือนก่อน

      Bos kahit mag baliktad Ang line 1 at line 2 ok lang ba supply

  • @JoniEscal-jl5jl
    @JoniEscal-jl5jl 10 หลายเดือนก่อน

    Sir pwede ba wala ng ground ang outlet ng aircon,salamat po

    • @SAYDETV
      @SAYDETV  10 หลายเดือนก่อน

      Pwede po

  • @jovelynsurbano6561
    @jovelynsurbano6561 ปีที่แล้ว

    Sir paano malalaman na kailangan 20ampers yong gamitin na CB at OUTLET? pano ba malalaman ang capacity ?

    • @SAYDETV
      @SAYDETV  ปีที่แล้ว

      Sa breaker at outlet nakalagay gyan kung ilang ampers ang capacity nya, halimbawa 30A. Lahat ng electrical material at machine may nalagay yan na specification,

  • @lucky-hs4zh
    @lucky-hs4zh 2 ปีที่แล้ว

    sir gnto kasi my saksakan na kami lagyan ko sana breaker pano ko po malalaman yung live qt neutral doon sa my saksakan? normal saksakan lang po ito eh. salamat po new subscriber

    • @lucky-hs4zh
      @lucky-hs4zh 2 ปีที่แล้ว

      san din nkakabit yung green sir

    • @SAYDETV
      @SAYDETV  2 ปีที่แล้ว +1

      Gumamit ka ng screw test light ang live may iilaw yan 220V ang neutral hindi iilaw 0 V, pwe mo tingnan itong link kung paano magtest ng live at neutral.th-cam.com/video/RNZBKy8tFnE/w-d-xo.html

    • @SAYDETV
      @SAYDETV  2 ปีที่แล้ว

      Naka connect sa ground, pra yan sa equipment grounding.

    • @KimRubionvlog
      @KimRubionvlog ปีที่แล้ว

      Thanks sir..pwede poba aq gagawa ng breaker pero..plug lang yon gagamitin ko sasaksak kolang sa oulet malayo kc ang main breaker sa amin pwede kaya yon direct ko nlang saksak

  • @rowelignacio-g5i
    @rowelignacio-g5i 13 วันที่ผ่านมา

    Yung lineside sir ground nuetral at live sa panelboard naka connection yung nuetral at live tapos yung ground sa ground rud naka conect

    • @SAYDETV
      @SAYDETV  12 วันที่ผ่านมา

      Tama sir

    • @rowelignacio-g5i
      @rowelignacio-g5i 12 วันที่ผ่านมา

      ​@@SAYDETVLahat ba nang ground magkkasama lahat sa panel board?

    • @rowelignacio-g5i
      @rowelignacio-g5i 12 วันที่ผ่านมา

      @@SAYDETV may Tanong po Ako may Sarili pobang cb yung ref at washing machine

  • @godygarro6783
    @godygarro6783 2 ปีที่แล้ว +1

    Boss pede po ba ilagay yung live wire sa bandang kanan ng CB pagkaalam ko po kasi sa kanan po ang neutral at kaliwa po ang live

    • @SAYDETV
      @SAYDETV  2 ปีที่แล้ว

      Pwede po kahit saan nman yan ilagay ok lang.

  • @johnanthonyduron7966
    @johnanthonyduron7966 6 หลายเดือนก่อน

    sir may tanong lang po...paano po kong ang wire na galing sa breaker ay dalawa lang..paano ikabit salamat..

    • @SAYDETV
      @SAYDETV  6 หลายเดือนก่อน

      Ang grounding na wire e-connect mo sa body ng aircon sa bandang likod may screw bolt dyan na may sign na ground or kahit saan na bolt dyan mo e-connect ang ground wire tapos ibaon mo na lang sa lupa maglagay ka ng kahit steel bar lang doon mo econnect ang wire.

  • @lowellauguis1519
    @lowellauguis1519 ปีที่แล้ว +1

    boos ok lang po ba na wala na yang ground, kasi dito sa province namin wala na kasing ground dito Live lang at neutral. paki sagot naman po

    • @SAYDETV
      @SAYDETV  ปีที่แล้ว

      Ok lang po wag na lagyan ng grounding, live lng at neutral.

    • @lowellauguis1519
      @lowellauguis1519 ปีที่แล้ว

      @@SAYDETV salamat boss

  • @antonyula
    @antonyula ปีที่แล้ว +1

    Sir O.8 Hp na aircon ok lang ba na 15 amps na circuit breaker?

    • @SAYDETV
      @SAYDETV  ปีที่แล้ว

      Kung yan lng ang available mo pwede na yan, 👍🏿

  • @user-rj4re5rk8y
    @user-rj4re5rk8y 8 หลายเดือนก่อน

    sir okay lang ba magkabaligtad ang neutral at live wire?

    • @SAYDETV
      @SAYDETV  8 หลายเดือนก่อน

      Oo ok lang yang wag lang magkadikit.

  • @paksdiymechanic8525
    @paksdiymechanic8525 6 หลายเดือนก่อน +1

    Pwede pi ba mag palit ang live at neutral??

    • @SAYDETV
      @SAYDETV  6 หลายเดือนก่อน

      Pwede wag lang magsalubong.

  • @marjunio3307
    @marjunio3307 ปีที่แล้ว

    Sir ask lang paano if magkabaliktad Po Ang neutral at live .. ok lang Po b Yun

    • @SAYDETV
      @SAYDETV  ปีที่แล้ว

      Ok lng sa live at neutral magkabaliktad kasi sa breaker nakaconnect ang neutral wag lng ang live at ground wire kasi sa body nakaconnect ang ground

    • @SAYDETV
      @SAYDETV  ปีที่แล้ว

      Ok lng sa live at neutral magkabaliktad kasi sa breaker nakaconnect ang neutral wag lng ang live at ground wire kasi sa body nakaconnect ang ground

  • @kikstv207
    @kikstv207 ปีที่แล้ว

    Okay lang ba kahit walang ground?

    • @SAYDETV
      @SAYDETV  ปีที่แล้ว

      Ok lang po Kahit walang grounding piro mas maganda po kung lalagyan mo ng ground kahit . maglagay ka lang ng wire galing body chasing tapos ibaon mo sa lupa ang dulo ng wire.

  • @gumabonsharmainej.7787
    @gumabonsharmainej.7787 2 ปีที่แล้ว

    Hello po. Paano po pag yung breaker meron na outlet tpos mg seperate sub meter lng kmi sa kwarto namin pwde ba yung wire dun ilagay sa main na breaker sa ibaba?

    • @SAYDETV
      @SAYDETV  2 ปีที่แล้ว

      Ok lang po yong breaker na may outlet na, tapos sa itaas ng main breaker mo e-connect ang breaker para sa Aircon kasi kung sa baba ng main breaker maapektuhan ang ilaw at appliances mo pag nag automatic off and on ang Aircon, hihina ang ilaw at power ng appliances mo.

  • @noelmundo5577
    @noelmundo5577 4 หลายเดือนก่อน +1

    20 amp lng CB sir? Ilang hp ba ACU?..

    • @SAYDETV
      @SAYDETV  3 หลายเดือนก่อน

      1hp lang sa 20A na breaker.

  • @LorenzoPond-ue8vj
    @LorenzoPond-ue8vj ปีที่แล้ว

    Sir, saan po ba ako kukuha ng source para sa breaker ng akong split type. Puno na panel board namin eh.

    • @SAYDETV
      @SAYDETV  ปีที่แล้ว

      Direct ka kumuha ng supply sa service entrance doon malapit sa service cup bago pumasok sa panel board mo lagyan mo na lang ng 30A na breaker, ganyan ang eksaktong wiring para sa supply ng Aircon.

    • @LorenzoPond-ue8vj
      @LorenzoPond-ue8vj ปีที่แล้ว

      @@SAYDETV para po sana sa tatlong kwarto isa isa ang aircon bawat room 1hp each. ano diskarte pag ganyan

    • @SAYDETV
      @SAYDETV  ปีที่แล้ว

      @@LorenzoPond-ue8vj tatlong 1hp sa tatlong kwarto? Maglagay ka ng tatlong breaker na 20A kada aircon sa tatlong kwarto tapos don ka kumuha ng supply sa service entrance direct mo i-connect sa isang breaker tapos i-jumper mo nlng papunta sa pangalawang breaker Hanggang sa pangatlo #6 gamitin mo na wire galing service entrance papunta sa unang breaker #8 ang jumper sa pangalawa at #10 sa pangatlo.

    • @LorenzoPond-ue8vj
      @LorenzoPond-ue8vj ปีที่แล้ว +1

      @@SAYDETV salamat boss! Gets ko na. Salamat2.

  • @pinoyrc8502
    @pinoyrc8502 ปีที่แล้ว

    Sir kapag walang breaker ang aircon po malakas po ba komain ng kurinte?

    • @SAYDETV
      @SAYDETV  ปีที่แล้ว

      Pariho lng, maka save ka lng kunti kung may breaker kasi yong ibang Aircon may standby power.

    • @SAYDETV
      @SAYDETV  ปีที่แล้ว

      Pariho lng, maka save ka lng kunti kung may breaker kasi yong ibang Aircon may standby power.

  • @user-ux2jz7kj6h
    @user-ux2jz7kj6h 9 หลายเดือนก่อน

    pwede po bang maka hingi ng list sa materiales na gagamitin ?

    • @SAYDETV
      @SAYDETV  9 หลายเดือนก่อน

      Kung 1hp ang aircon mo 20A na breaker, #12 or 3.5mm2 na wire, tapos special outlet yong may ground na tatlo ang butas.

  • @alexbajao9870
    @alexbajao9870 2 ปีที่แล้ว

    Pano po pag..3 Aircon po ..3 breacker din po ba tag Isa Isa Sila?

    • @SAYDETV
      @SAYDETV  2 ปีที่แล้ว +2

      Yes po kung 3 aircon 3 circuit breaker din tig iisa sila, tapos sa line side po ng main circuit breaker e-connect ang wire kasi kung sa load side po maapektuhan po yong ilaw kukurap po yan pati narin po mga appliances.

    • @pointscenes432
      @pointscenes432 5 หลายเดือนก่อน +1

      Pwede po ba isang linya lng ang apat na aircon master,at kanya kanyang outlet nmn sla. at isang CB lng,ano recommend mo master na ampere na circuit breaker at wire para sa apat na aircon na isahang linya lng sla, ksi ang pagkakaalam ko sa isang aircon ay isang 20A n cb, paano nmn kung apat at isang linya lng sla,anong wire size at Ampere ang gagamitin na? ... Tanong ko lng master, Gagamitin lng po ksi sa program nila,at tatangalin nmn pagkatapos ng program na po... Pakisagot po master?

    • @DeeyonRouche-cz6kn
      @DeeyonRouche-cz6kn 3 หลายเดือนก่อน

      sir di pwede yung ganon from lineside kung sakali 3 or more na ac dapat may cb or nema3r bawat isa . d pwede parallel sir .

  • @enriqueacupan2979
    @enriqueacupan2979 ปีที่แล้ว

    idol ask ko lang po kc turo po sken line to line bakit po line to newtral po kc sabi po mag kukulang daw po yunh supply kc line to newtral ay mababa line 220 v at newtral ov at line to line 110 to 110 means 220 v ano po taga tama nalilito po ako sa tulad ko na baguhan at fresh gradute lang po sana po mapansin ninyo message ko

    • @SAYDETV
      @SAYDETV  ปีที่แล้ว

      Ang power supply po natin ay dalawang klase line to line at line to neutral, pariho lng yan sila 220V walang mababa dyan. sa line to line may 3phase na supply 110V, 220V,380V,480V pataas depende sa transformer na gamit, baka yon ang ibig sabihin ng nagturo sa inyo.

    • @enriqueacupan2979
      @enriqueacupan2979 ปีที่แล้ว

      @@SAYDETV salamat po

  • @noel9143
    @noel9143 3 หลายเดือนก่อน

    Boss 30 Amp. Sa 75 na acu. Pwede ba ton?

    • @SAYDETV
      @SAYDETV  3 หลายเดือนก่อน

      Ang 30A ay para yan sa 1.5hp na acu.

  • @thebestu1672
    @thebestu1672 ปีที่แล้ว +1

    Gusto ko malaman saan at paano mag tap mg wire

    • @SAYDETV
      @SAYDETV  ปีที่แล้ว

      Kung para sa aircon ang i-tatapp mo sa line side ng main breaker ka magtapp at kung paano i-connect mo lng sa dalawang wire line at neutral, piro kung hindi ka electrician ay dilikado po yan, mas mainam na ipagawa mo na lang.

  • @morrisrino5995
    @morrisrino5995 ปีที่แล้ว

    Bos Tnung lng po .di po ba blidtad ung live Chka neutral.. Ninyo

    • @SAYDETV
      @SAYDETV  ปีที่แล้ว

      Pwede po yan sir magkabaliktad neutral at live.

  • @jomarietugade3991
    @jomarietugade3991 ปีที่แล้ว

    Ano po ba ang 3.5 de dose ba o d10

    • @SAYDETV
      @SAYDETV  ปีที่แล้ว

      #12 po ang 3.5, #10 nman ang 5.5

  • @ronalddelco1971
    @ronalddelco1971 ปีที่แล้ว

    Line to neutral ba yan boss?

    • @SAYDETV
      @SAYDETV  ปีที่แล้ว

      Oo line to neutral po yan.

  • @raivendc732
    @raivendc732 10 หลายเดือนก่อน +1

    Sir ung kulay green san nakalagy po yan

    • @SAYDETV
      @SAYDETV  10 หลายเดือนก่อน

      Ground yan connected yan sa neutral, pwede rin i direct mo yan sa lupa ibaon sa ground bar

  • @yesha7457
    @yesha7457 ปีที่แล้ว

    Boss nakukulohan ako ng demontration mo diba ang aircon outletmayron mga sign diba sa likod ng aircon Mayron L o N ipaliwanag mo nga idol nalilito ako sayo

    • @SAYDETV
      @SAYDETV  ปีที่แล้ว

      Ang L live 220V ang N neutral 0V, ang ground para sa body ng aircon grounding yan na nakaconnect sa lupa,

  • @denvervicente4704
    @denvervicente4704 2 หลายเดือนก่อน

    Sir, .75hp aircon, 900 watts, okayy lang ba isaksak sa 2.0 mm na wire? Rekta sa outlet. Salamat sa mga sasagot.

    • @SAYDETV
      @SAYDETV  2 หลายเดือนก่อน

      Pwede yan sir, yong wire ng .75hp maliit lang wire nyan kumpara sa 2.0mm

    • @dominicmanubay8875
      @dominicmanubay8875 หลายเดือนก่อน

      ​@@SAYDETVtalaga po yung .6hp na ac pwede direct sa outlet nalang?

  • @cag88x
    @cag88x 5 หลายเดือนก่อน

    boss link nyo po how to convert 220v to 110 v

    • @SAYDETV
      @SAYDETV  3 หลายเดือนก่อน

      Wala pa ako video nyan, pwede ka gumamit ng step down transformer input 220V output 110V, pwede rin kung ang supply mo ay line to line 220V ang isang linya nyan ay 110V dyan mag-connect tapos tapp ka sa neutral wire para magkaroon la ng 110V na supply.

  • @FrancisDonozo-oo1ni
    @FrancisDonozo-oo1ni ปีที่แล้ว +1

    Tanong ko lang pwde ba Hinde ko na lagyan ng ground Ang air con ko

    • @SAYDETV
      @SAYDETV  ปีที่แล้ว

      Pwede nman po piro mas maganda may ground.

    • @FrancisDonozo-oo1ni
      @FrancisDonozo-oo1ni ปีที่แล้ว

      @@SAYDETV ok salamat po sir,

    • @dominicmanubay8875
      @dominicmanubay8875 11 หลายเดือนก่อน

      ​@@SAYDETVsir ask po. saan ako kukuha ng supply ng CB kung wala kaming main breaker sa bahay. fuse box lang po kami. salamat

  • @ronaldomendez1349
    @ronaldomendez1349 8 หลายเดือนก่อน

    paano kong walang ground yong electrical ng bahay

    • @SAYDETV
      @SAYDETV  8 หลายเดือนก่อน +1

      Maglagay na lang ng ground wire sa body ng aircon e-connect tapos ibaon sa lupa lagyan ng ground rod o bakal.

    • @ronaldomendez1349
      @ronaldomendez1349 8 หลายเดือนก่อน

      @@SAYDETV Maraming salamat 👍

  • @Maryann-ne2te
    @Maryann-ne2te ปีที่แล้ว +1

    Ok lang po ba ang breaker n may kasama na outlet sir

    • @SAYDETV
      @SAYDETV  ปีที่แล้ว

      Ok lng po sir.

  • @ramilgaditano152
    @ramilgaditano152 10 หลายเดือนก่อน

    Sir pwede Po ba kahit Wala nang ground

    • @SAYDETV
      @SAYDETV  10 หลายเดือนก่อน

      Pwede,

  • @RalphNavarra
    @RalphNavarra ปีที่แล้ว

    Mag Kano po Ang magagastos Dyan sa pag kabit Ng breaker....salamat po

    • @SAYDETV
      @SAYDETV  ปีที่แล้ว

      Hindi po aabot ng 1k

  • @cailieramos4406
    @cailieramos4406 ปีที่แล้ว

    Sir kng magkapalit

    • @SAYDETV
      @SAYDETV  ปีที่แล้ว

      Ok lng magkapalit ang neutral at live.

  • @emelgonce9723
    @emelgonce9723 ปีที่แล้ว

    Sir tanong lang po, pwede po ba e.tap yung outlet ng refrigerator sa circuit breaker ng aircon

    • @SAYDETV
      @SAYDETV  ปีที่แล้ว

      Hindi pwede dapat may sariling breaker ang aircon at ref. At kung sakaling pagsabayin mo 40A na breaker ilagay mo.

    • @emelgonce9723
      @emelgonce9723 ปีที่แล้ว

      @@SAYDETV thank you Sir 😘 40A nalang ilagay ko para isang cb nlng

    • @jhomarleonardo6421
      @jhomarleonardo6421 ปีที่แล้ว

      ​@@SAYDETV boss pde ba isang breaker ang aircon and ref pero 60amper breaker?

    • @SAYDETV
      @SAYDETV  ปีที่แล้ว

      Pwede po kasi 60A naman ang breaker mo, kahit 50A pwede na, kahit nga 40A kung 1hp lng aircon mo.

  • @jcnas1166
    @jcnas1166 ปีที่แล้ว

    Hello po ask ko lang po. pwede ko po ba iplug ang aircon ko na .5hp sa 10amp na outlet. meron namn breaker na 30amp pero ang nailagay na outlet ay 10amp lang. Thanks po.

    • @SAYDETV
      @SAYDETV  ปีที่แล้ว

      Pwede po kaya yan ng 10A na outlet, mababa lang yan na .5hp.

    • @patriciacamilledelim2437
      @patriciacamilledelim2437 ปีที่แล้ว +1

      Hello kuya may breaker na po na nilagay para split type namin na 1hp. Pwde na po syang isaksak sa 20 amp na outlet?

    • @SAYDETV
      @SAYDETV  ปีที่แล้ว

      @@patriciacamilledelim2437 pwede na po,

  • @user-lx4zn9ee7y
    @user-lx4zn9ee7y 2 หลายเดือนก่อน

    Saan dapat kumuha ng linya ng kuryente?

    • @SAYDETV
      @SAYDETV  2 หลายเดือนก่อน +1

      Kung para sa aircon kuha ka sa service entrance

    • @rommeldeguzman2980
      @rommeldeguzman2980 2 หลายเดือนก่อน

      Pwede po b sa outlet din kumuha ng linya ng kuryente??

    • @user-lx4zn9ee7y
      @user-lx4zn9ee7y 2 หลายเดือนก่อน

      @@rommeldeguzman2980 yes. Yung sakin sa outlet din kumuha ng linya.

  • @sergeybz95
    @sergeybz95 ปีที่แล้ว

    Sir pwede po ba wala na yung ground o green na wire?

    • @SAYDETV
      @SAYDETV  ปีที่แล้ว

      Pwede po

  • @darlalfredsoriano1725
    @darlalfredsoriano1725 ปีที่แล้ว

    Boss tanong lng po
    Pano po kung line to graound gagawin ko ibig sabihin live wire lng ung nakalagy sa breaker tas ung neutral o line 2 ko diba po ilalagay siya sa body ng panel
    Pano po kung maglalagay po ako ng acu outlet diba po meron siya live,neutral tas g eh san ko po ilalagay ung neutral o L2 ko sa ground po ba o neutral ng outlet?

    • @SAYDETV
      @SAYDETV  ปีที่แล้ว

      Sa ground po ng outlet, tatlo ang butas ng out para yan sa live neutral at ground, sa likod po ng outlet miron yan naka-indicate na level o sign kung saan ilalagay ang wire