Jazak Allah bohat detail say ap nay bat ki meray pas inverex kayahee modle hay 24 volts may is may aik problem a rahee hay k sbu aur sol first ki option may k solar of honay k bad bhe jab light chali jati hay to wo battery ko 23 volts tak drain karnay k bad wapda say charging start karta hay ye fault hay iska ya setting ka masla hay isay kaisay therk kia jaue
Ye fault nahi hai Bhai , jis tarah ap ne setting ki howi hai us main aise hi hota hai, is setting main battery apne low value tak drain hone k bad hi charging dobara wapda pe start hoti hai.
Mera khyal hy k 24 volt k leay apko settings double karni hogi. Kion k jin videos mein 12 aur 24 volt dono settings btai hain wo double kar rhy thay setting ko. Yan 11.5 k bajay 23 volt
12 no. ki setting 11.5volts and 13 no. ki setting 13 volts rakhna ups kalye buhut behtar ha. in dono settings main 1.5volts ka difference hone ki waja se baar baar wapda aur solar ki switching nahi hogi.
Bhai ik help chahye, please guide kr den.. Meri 1st setting sbu par ha or 16 no oso par ha.. Lakin rat ko jab battries khatam hoti hen to wapda battries ko charge krna shuru kr deta ha.. Iska kya hal ha k wapda battries charge na kry
Phr simple solution ye ha k ap UPS ka Charging plug ya switch ko Socket main laga rehne dy lekin uska button OFF rakha karein raat ko. is tarah wapda ki supply ups ko nahi mile gi, lekin plug switch k zarye common neutral milti rahe gi load ko.
Sbu setting main Ghar ka load 1st priority par solar pe chalta ha. 2nd jab solar output kam ho tu Battery aur solar aik sath load ko chalati ha,3rd yani last main utility pe ghar ka load chalta ha jab Battery k voltage low level warning pe pohonch jaye ya phr battery k voltage 12 number setting pe pohonch jayein.
Sub pucha h unu n sub m solar first chaly ga agr load ziada hai to sath utility le ga battery end m agr utility na ho tb ya solar na ho to ups bn jae ga
Ap OSO aur CSO dono kar sakte ha. Lekin Only OSO karne par sirf aur sirf solar panels battery ko charge kare gy. Jab k CSO yani solar first ki sorat main din main battery solar panels par aur raat ko wapda pe charge hogi.
agar only solar nahi ha tu ap CSO yani solar first ki option ko select kar lain, taka pehle batteries ki charging solar panels pe ho, aur jab solar nahi hoga tu wapda charge kare gi.
hello sir kindly setting no. 12 aur 13 ka bata dain. ma ne only SOLAR choose kiya hai setting no. 1 ma,, ma chata hon k jaise hi solar katam ho battery b ziada use na ho aur current wapda pe ah jaye aur phir subah ko solar on ho tu os pe load chala jaye..... so ma setting no. 12 13 kaise set karon?
Bhai 12 no. ki setting ap 12Volt kar lein, jese hi solar output kam hogi tu battery k 12Volt hone par wapda aa jaye gi ,jis ki waja se battery kam use hogi aur jald charge ho jaye gi.
Salam mery pas b yehi inverter ha kya men is men 300 k 2 panal laga sakta hu agr laga sakta hu to un ko paralal men lagana chahiy ya series men kindly confrm kr den
آداب ۔ میں پاور میکس کا 5 کلوواٹ کا سسٹم لگایا ہے اور اس کے ساتھ 545 واٹ کی چھ پلیٹ سولر لگائی ہیں۔ اس پر میرا پرانا اے سی نہیں لگتا۔ کیا اس کے لیے مجھے انورٹر اے سی لینا ضروری ہے۔
السلام علیکم بھائی جان کیا حال ہیں بھائی جان میرے پاس پرائی میکس کمپنی کا پی وی 4000 انورٹر ہے85 5واٹ کی چار سولر پینل پہ میں نے اس کو انسٹال کیا ہے بیٹری چارجنگ کی سیٹنگ میں نے اونلی سولر پہ کی ہوئی ہے لیکن پھر بھی رات کے ٹائم جب یہ بائی پاس پہ کام کر رہا ہوتا ہے تو ڈیڑھ ایمپیئر کرنٹ استعمال کرتا ہے یو پی ایس اؤٹ پٹ لوڈ اگر کٹ اف کر دیں پھر بھی ایک ایمپیئر کرنٹ استعمال ہو رہا ہوتا ہے اور بیٹری چارج نہیں ہو رہی ہوتی یہ ایک ایمپیئر کرنٹ کہاں استعمال ہو رہا ہے اس کی وجہ بتا دیں مہربانی ہوگی
بہت جناب ۔۔ بہت اچھا سمجھایا ۔
آپ استاد ہو ۔۔۔۔۔۔ جزاک اللہ
جزاک الله خیرا
یہ اب تک کی بیسٹ ویڈیو ہے جو سیٹنگز کے حوالے سے موجود ہے
JazakAllah,, Bundle of thanks
ماشاءاللہ آپ کے لیے دعا گو ہیں کہ اللّٰہ پاک آ پ کو صحت تندرستی عطا فرمائے آمین ہمشہ خوش مسکراتے رہے اور دوسروں کی مدد کرتے رہیں جزائے خیر
Masha Allah zabardast aise information kisi channel par nahi mili.
Thanks a lot
Very well done bht zabardust
Thank you so much 😊
Bht acha samjhaya
Aur tesla ke screen indication be samjaien jaisay ap ne inverex ka bataya tha
boht zbardast or aala video bnai hai ap ne ❤❤❤❤
Thanks brother
❤ Allah apko ajar dain
Ameen
You are best one on TH-cam
Best Explanation❤
Thanks a lot 😊
وعلیکم السلام
جزاكَ اللّٰه
Ameen.
Behtreen,simple r complete information.
bohat achi video ha. bohat se video mily gi youtube. par achi video kisi ne nahi bani. aik chez ki samj a rahi ha. ❤❤❤
Bundle of thanks
It is the best video I have ever watched about the setting of inverter, trillions of thanks buddy, can you make one video about wiring of change over?
Video posted about wiring of change over
Very good work
Bundle of thanks
YOU ARE THE BEST ONE
Thanks for appreciating..
MaSha Allah ❤
السلام علیکم
Wa Alikum Aslam
Very informative video thanks
Very good
Thanks
Best video❤
Very nice
Thanks
Good joob
Gre8 yaar thanks
Zabar10
JazakAllah
Jazahklah❤❤❤❤❤❤
Allah bless you
Ameen,. JazakAllah
Jazak Allah bohat detail say ap nay bat ki meray pas inverex kayahee modle hay 24 volts may is may aik problem a rahee hay k sbu aur sol first ki option may k solar of honay k bad bhe jab light chali jati hay to wo battery ko 23 volts tak drain karnay k bad wapda say charging start karta hay ye fault hay iska ya setting ka masla hay isay kaisay therk kia jaue
Ye fault nahi hai Bhai , jis tarah ap ne setting ki howi hai us main aise hi hota hai, is setting main battery apne low value tak drain hone k bad hi charging dobara wapda pe start hoti hai.
Ap SOL first k sath CSO setting kar lein, is setting se battery Sham ko jab solar panels chale jaye gy tu charging wapda pe jald shift ho jay..
Good job Bhai ❤
Bhai jan 24 volt k bary mein b bol dety aap
Mera khyal hy k 24 volt k leay apko settings double karni hogi.
Kion k jin videos mein 12 aur 24 volt dono settings btai hain wo double kar rhy thay setting ko.
Yan 11.5 k bajay 23 volt
❤❤❤❤❤❤❤
bohat achi video bani ha ap ne😊
Kindly do video on fronus 2000pv inverter settings.
Ye setting Sako inverter k lye b hai k nhe
thora buhut farq hota ha, lekin maximum parameters yehi hote ha..
@@A1electrictech and Sako inverter Kaisa hai laina chahiyai k nhe
Nice, Respected sir, Thanks
12 or 13 number setting ka lia volts kitna rkhna chaye?
12 no. ki setting 11.5volts and 13 no. ki setting 13 volts rakhna ups kalye buhut behtar ha. in dono settings main 1.5volts ka difference hone ki waja se baar baar wapda aur solar ki switching nahi hogi.
Mera ups man start e 22 volt hta 12 number setting man aur 13 number setting man 24 volt sa?
Bhai ap ne two batteries yani 24volts ka sysytem lagaya howa ha,islye unki ye settings default pe hoti ha,
jabka maine apko 12volts k lihaz btaya tha
Shukria
Agar 150v la 4 plate lagy ho to charging volt Kitna pa rakhna chye 20 30 40 ya 50
Bhai ik help chahye, please guide kr den..
Meri 1st setting sbu par ha or 16 no oso par ha..
Lakin rat ko jab battries khatam hoti hen to wapda battries ko charge krna shuru kr deta ha..
Iska kya hal ha k wapda battries charge na kry
Phr simple solution ye ha k ap UPS ka Charging plug ya switch ko Socket main laga rehne dy lekin uska button OFF rakha karein raat ko. is tarah wapda ki supply ups ko nahi mile gi, lekin plug switch k zarye common neutral milti rahe gi load ko.
@@A1electrictech bhai bht bht shukria
Welcome Brother
Goood
Bhai is ups par ktny fan or light chl skti hain...or performance ksi ha ha inverter ki....kindly tell..
Bhai, is ups pe 6 roof Fans aur 6 LED lamps easily chal sakte hai,, aur performance bhi kamal hai
good
Thanks
Plz batie 4 plate 150 ka hy to charging 40 50 amr pa rakha chye ya kitna
Bhai 50Amp setting best ha 4 solar plates kalye.
Maximum Charging Current= Solar charging current+ utility charging current
Mere pass bp same ups ha pochna yep ha ka is ups ka sath kitne watt ki solar plate laga sakte hain plz zaror btana.
750w 5+5 wala inverex ka ups ha.
Bhai ap 12volts main koi bhi solar plate laga sakte ha..aj kal 150w,180w aur 220w main 12volts ki solar plates mil jati ha..
12 number setting ideal kon c ha jis main 70% tk batteries use hon phir wapda pr shift ho ? 27v total charge ha default 23v ha 12 number setting main.
Sir agr ups par load kam ho to kia ham is output load kam kar sakty hia taky bty jaldi discharge na ho jaye
Jee bilkul.You are right 👍
SUB setting main solar key sath utility bhi chal raha hota hey
Sbu setting main Ghar ka load 1st priority par solar pe chalta ha. 2nd jab solar output kam ho tu Battery aur solar aik sath load ko chalati ha,3rd yani last main utility pe ghar ka load chalta ha jab Battery k voltage low level warning pe pohonch jaye ya phr battery k voltage 12 number setting pe pohonch jayein.
Sub pucha h unu n sub m solar first chaly ga agr load ziada hai to sath utility le ga battery end m agr utility na ho tb ya solar na ho to ups bn jae ga
Novatek invertor ka b btaye kisi din
Bhai Apollo mppt inverter 1.2 ki full and good settings ki video please upload Karen
Maxpower 7000 duo ki setting ki video banaye.
In Sha Allah
3.5kw system mai battary cutoff ktny pa rakna hoga...2 Battary hai
2 batteries kalye low Battery cut off voltage ap minimum 21v aur maximum 24v rakh sakte ha.
Salam bhai agr mn battery ki option ko sirf solar pe rakhta hu k wo sirf solar se charge ho to kia uska koi nuksan hoskta
Wa Alikum Aslam, bhai solar UPS main solar panels kalye controller laga hota ha, jo Battery ki charging ko control karta ha,Islye koi issue nahi.
@@A1electrictech mn only OSO kr skta hu ap yhi keh rhy hn ??
Mera inverter homage 1kwa 1214 model lga hua h
Ap OSO aur CSO dono kar sakte ha. Lekin Only OSO karne par sirf aur sirf solar panels battery ko charge kare gy.
Jab k CSO yani solar first ki sorat main din main battery solar panels par aur raat ko wapda pe charge hogi.
@@A1electrictech
Pls card ky bare me batahe gy
❤
Mry invertr m onlu SOL hy e ni,
Omega 2022 850 wat, kindly guide,
agar only solar nahi ha tu ap CSO yani solar first ki option ko select kar lain, taka pehle batteries ki charging solar panels pe ho, aur jab solar nahi hoga tu wapda charge kare gi.
❤❤❤❤❤
hello sir kindly setting no. 12 aur 13 ka bata dain. ma ne only SOLAR choose kiya hai setting no. 1 ma,, ma chata hon k jaise hi solar katam ho battery b ziada use na ho aur current wapda pe ah jaye aur phir subah ko solar on ho tu os pe load chala jaye..... so ma setting no. 12 13 kaise set karon?
Bhai 12 no. ki setting ap 12Volt kar lein, jese hi solar output kam hogi tu battery k 12Volt hone par wapda aa jaye gi ,jis ki waja se battery kam use hogi aur jald charge ho jaye gi.
Jab k 13 no. ki setting ap 13.5 volts rehne dy, jese hi solar output subha ana shoro hogi tu load solar par shift ho jaye ga 13.5volts par.
Agr raat ko soty hue hum 16 no. Ki setting only solar krle ta k din ma solar se charge ho aur subha uthty he cso krdem tou kesa rahega??
Crown invertor 3kv ki bahtreen setting 2 battery 200 persetting batha deian
agar system 24v ho to 12 aur 13 no. setting konsi rakhe
इसमे कैसे पता चलेगा कि पैनल आज कितना यूनिट बनाया l लोड पर कितना ampear लोड ले रहा है l बैट्री कितना बचा हुआ है l
sir sunlife inverter ki setying bta dein
Brother ager hum aik he time py wapda aor solar dono sy battery ko charge krna chahy tu konsi setting karni hongi
Bhai us kalye mppt hybrid ups lena pare ga. Us main ye option hoti hai.
Aslamualikum..bhai 2 no setting mein agr maximum defult current rkhy tu khoi problem tu ni oh gy . Mry pass 3 180 ky pannal hain...
Bhai tels 3 kVA ke setting batien tafsee se
وعلیکم السلام
Bhai please inverex Yukon 2 24volt ki details video banaen
Sir omega 2.4 kva pe fridge Chala Sakte hai ?
Salam mery pas b yehi inverter ha kya men is men 300 k 2 panal laga sakta hu agr laga sakta hu to un ko paralal men lagana chahiy ya series men kindly confrm kr den
Sir inverex 2.5 main agar main battery ko wapsa se bilkul bhi charge nahee karana chahta to kya settings ki jaye ?
1 number settings pe SBU per rkhen.
Aur youtub pe kafi videos hain wo bhi dekhin un mein detail hy jo ap pioch rhy hai
Kion k ye kafi samjhny wala topic hy
Mere area mai loadshading bhut hy app ki es setting se mujhe backup nea milta zayda
آپ کی ویڈیو سے کچھ پتہ چلا کہ کیا کرنا ہوتا ہے۔ شکریہ
Plz make video of Tesla 5kv infini inverter settings
salam sir please proline 3kw ki setting bta dian
Max inverter m b yae setting hoge 6 plates pa
Panel kitnay watt walay lagain gay aur parallel laganay hn ya series
Bhai 12volts wale solar panels lage gy, jo ke 150 watt se 220watts tak ate hai aj kal, aur tamam panels parallel main lage gy
Bhi jan main chatta hun ups wapda s khatam ho aur solar plate connect ho kia hum ac load chla saktey hy
Veyron 2 mein bluetooth connrctivity hoti hai bhai ?
wesy mazy ki batt ye hay k ye inverter solar par 150w tak load hi deta hay hun bachay ga kia
Bhai, maine is ups ke sath 5 solar panels tak use kiye hai, aur AC air cooler, washing machine aur Juicer machine tak chalai hai is pe.
Sir mainai oso he rakhi hai par jaisai he sham Hoti hai battrey full sai 30 percent pai q raih jati hai raaat ko kaya load hota batteries pai
Bhi crwon 6kv elego 4 battery 1800 hai is ki setting ka bata dain
Bahi agar alrdy controler laga ho to kiya soler ups k sath conroler lgane ki zarorar ni hogy
Bhai solar ups ke andar hi controller already laga hota hai, islye alag controller lagane ki zarorat nahi
2 300 wali plates ho to Kitne ampr?
SETTING NO 2 OR 11 MAIN KIA DIFFERANCE HY....PLZ EXPLAIN
Setting no. 02 Maximum solar charging current kalye ha, aur Setting no. 11 maximum utility yani Maximum wapda charging current kalye hoti ha.
Bhai ups direct wapa le rha ha solar ni wapda off kro to solar chlata ha homeage 1214scc model ha
Sir is vedio me app ne bulk charging aur floating charging ke bare me nahi bataya plz me bulk voltage kitna rako aur floating kitna rako????
hello sir
Sir hamare pas solar se battery charg NAHI hota Kya masla hai
Single battery ka liye?
Jee han
آداب ۔ میں پاور میکس کا 5 کلوواٹ کا سسٹم لگایا ہے اور اس کے ساتھ 545 واٹ کی چھ پلیٹ سولر لگائی ہیں۔
اس پر میرا پرانا اے سی نہیں لگتا۔ کیا اس کے لیے
مجھے انورٹر اے سی لینا ضروری ہے۔
Sir g as ma apne as kuch setup point q chore hi jesa ka 4 number wala wagerA
👍
Best of lock
My inverter showers no. 10 error with beeps when we on wapda.
Ap se rabita kaise Kia ja sakta hay
2 no setting explain q nhi krty
What is meant by fault F12
زبرداست
السلام علیکم بھائی جان کیا حال ہیں بھائی جان میرے پاس پرائی میکس کمپنی کا پی وی 4000 انورٹر ہے85 5واٹ کی چار سولر پینل پہ میں نے اس کو انسٹال کیا ہے بیٹری چارجنگ کی سیٹنگ میں نے اونلی سولر پہ کی ہوئی ہے لیکن پھر بھی رات کے ٹائم جب یہ بائی پاس پہ کام کر رہا ہوتا ہے تو ڈیڑھ ایمپیئر کرنٹ استعمال کرتا ہے یو پی ایس اؤٹ پٹ لوڈ اگر کٹ اف کر دیں پھر بھی ایک ایمپیئر کرنٹ استعمال ہو رہا ہوتا ہے اور بیٹری چارج نہیں ہو رہی ہوتی یہ ایک ایمپیئر کرنٹ کہاں استعمال ہو رہا ہے اس کی وجہ بتا دیں مہربانی ہوگی
bohat achi video ha
Buhut buhut shukriya