Tie Beam ko yaha main Plinth Beam Bolna Bhul gaya hu. Iske lie maaf kijiyega. Baki ka Video ko Like aur Share kar ke apna pyar mujhpe jarur dikhaye. Thanks
Most important "HIGHLIGHT" or USP of this entire video..is the explanation behind 'why putting 2nos. 12mm dia in upper & 2 nos.10mm dia still in lower tie beam... EXCELLENT 👍👍👍 Rest 4 nos. 10mm dia can easily manage in upper plinth beam...thanks🙏
Very good presentation 👏 👌 👍 💐. Now tell me while erecting the barbed wire on the top, is the wall likely to get weaken or shorten the life span of the wall?
Sir mn apka bht purana subscriber hoon or mjjy bht kushii ho rii ha k ap wapiss active ho gaye hain apny channal pr.... Sir aik request ha mairii k aap koii aik project lay kr uskii dwg perhna or uska total estimate nikaln pooori video series dalain proffesional project kii...... Tnxx & love from islamabad 🇵🇰
As you mentioned thickness of PCC and Rcc to be 75 mm, Also share What should be the dimension of Platform (Horizontal and Vertical Dimension ) of Same
Sir, Thank you for your excellent explanation. You are really a fantastic Tuitor. But sir, You did not mention the width of the base column ( substructure )
Can we make same type of Boundary wall with 4 inch Brick wall thickness, Remain all we will keep same as you are suggesting?Asking regarding 🧱 Brick Thickness 4 Inch instead of 9 inch
Sirb thank you for plinth beam teaching . Accordingly you taught to use 12mm at top otherwise use all four rods 10mm apart frlom this rwo option , may we apply 12mm on all these four rods of plinth beam .
as ur fan, ur videos are too good, sir. 🙏🙏 I've a small doubt that, if we do trepizoidal footing r rectangular r square footing for a boundary wall column, it will go into the beside site, sir..? for this what we can do sir..?
Sir here brick work load will act on plinth beam in downward direction as the beam is simple supported on two columns. I think higher dia rod shall be at bottom. If plinth beam constructed on simple pcc on earth then higher dia shall be at top. I am not a civil engg hence I may be wrong.
Siir, thank you for your teaching in utube , about boundary wall that ,being a lay man understand about the same .. May i request forr a small elaboration. 1. You taught column size 10 x10 inch. 2. Plinth beam size also 10 x 10 inch . 3.brick wall size also 10 x 10 inch. In column and plinth beam the stirrup or tie up The stirrup 7inch x 7 inch and concrete margin either side (all) 1 inch , this comes 9 inch x 9 inch , the remaining 1 inch can I assume as plastering of 1/2 inch (half inch) x 1/2 inch. For brick wall it come to 9 inch x 9 inch for this also can i assume as plastering of 1/2 x 1/2 inch . Thank you once again please.
Sir column to column distance 20 feet kar saktay hn? Or Kia issi boundary wall ko in future rooms K back wall bana saktay Hain? I mean roof ka weight othaye ge wall?
I have observed stepped compound wall at some sites.why is stepped compound wall required and how to take levels of such stepped compound wall. Pls clear my doubt
Tie Beam ko yaha main Plinth Beam Bolna Bhul gaya hu. Iske lie maaf kijiyega. Baki ka Video ko Like aur Share kar ke apna pyar mujhpe jarur dikhaye. Thanks
Make video on shear wall. Reinforcement details of wall in high rise building spanning 60mts above
Sir compund wall ka column eccentric rakhna padega na?? Nahi to footing dusre ke plot mein ghus jayega na??
Sir ,,niche footing ka nahi batya ,jali ka kaise kitna
@@rohankharbanda5918 well point
Coloum ka jo base me jaali bNega wo ketna mm ka rod rahega
Thank You Very Much... You are One of My Best Teachers... Love You so Much... If Possible... I'll Meet You One Day
Most important "HIGHLIGHT" or USP of this entire video..is the explanation behind 'why putting 2nos. 12mm dia in upper & 2 nos.10mm dia still in lower tie beam... EXCELLENT 👍👍👍 Rest 4 nos. 10mm dia can easily manage in upper plinth beam...thanks🙏
Apne bahut good explanation ki ,achi tarah se Samj me aa gaya,🙏
बहुत अच्छे जी 🙏🙏 जानकारी के लिए बहुत धन्यवाद देता हूं।
Apke samjhane ka tarika accha hai sir , Apke jayse guru ke margdersahan se hi week student v apne aap ko good student ban sakta hai
Ap bhi sikho apne juniors ko v sikhau
My favorite civil Er channel😍😍😍😍
Great ! basic fundamental explanation for layman who intend to build boundary wall structures for their own homes 🙏
Mukesh Dada apnar lecture Khub Valo laga
Mukesh Bhai.. bahut zabardast
Bahot badiya sir 🔥🔥🔥
Very good and clear demonstration
In short an Excellent 😘😘😘😘 ummah
Bahut Badhiya jankari diya aapne sir.
Very nice explaination Thanks .Wish you all the best
Very good presentation 👏 👌 👍 💐. Now tell me while erecting the barbed wire on the top, is the wall likely to get weaken or shorten the life span of the wall?
No
I think u r the best in INDIA nice teaching technic & more helpful for freshers
great video keep it up. god bless you.
Very well explained sir
Best explanation ❤
Excellently described . Thanks .
Very nice way of explaination
Thanks for explaining in easy way.👍
Most welcome 😊
Nice one bro❣️
Good video
Informative
Bahut Acha excellent
Thanks sir....👍👍👍👍
Very good 👌🏻👌🏻👌🏻
Very nice.
Concise . Thank you
Good informative video bro keep continue hard work 💪and all the best 👍
V.v. good presentation Sir.
Tq sir it's very useful
Great video sir
GREAT BRO.
BHAGUT ACHAA BHAI
Nice information and explanation keep it up sir
Very well explained
Very Nice Sir...
Excellent...
Nice information sir.
Well explained👍
Informative video
Sir mn apka bht purana subscriber hoon or mjjy bht kushii ho rii ha k ap wapiss active ho gaye hain apny channal pr.... Sir aik request ha mairii k aap koii aik project lay kr uskii dwg perhna or uska total estimate nikaln pooori video series dalain proffesional project kii...... Tnxx & love from islamabad 🇵🇰
Excellent sir
Very good.
Very Interesting
very informative video sir
Bahut badhiya jankari hai sir. 5" wall me coulm ki distance kitna rkhe
Very knformative. Pl let me know plinth beam function design etc for compound wall
Ur videos are informative
Very Good
वहुत अच्छा
Awesome.
thanks a lot sir
Detailed info.thanks
Verry good suggestion sir
Thanks
Very good sir
@@pravinbahipatel7127 I want pricast boundary wall construction.
Very nice plz boq of this boundary wall
Thank you for your video
great sir
Sir , If we fill murram inside compound wall for a height of 5 feet and total wall height 10 feet above ground video me bataya jaisa ban sakte kya?
Super sir
Nice video Sir.
very important Lecture! Thanks
Super video sir
Very nice
As you mentioned thickness of PCC and Rcc to be 75 mm, Also share What should be the dimension of Platform (Horizontal and Vertical Dimension ) of Same
Do we need to provide expansion joint if the length of wall is more than 100m? If yes, then at what interval?
Sir ,mere boundary wall main nise 1.5 foot hi diya hain... Future main koi dikkat aiyegi kiya sir??
Super
thanks bro....
U welcome
Thanks sir
Sir, water supply schemes k liye bhi koi vedio bna de.. jisme WTP, Intake structure and overhead tank construction ka whole process bata de.. plzzzzzz
Thank you sir jii
Very nice video sir , kiya colum ka distance 12 fit rakh saktye h, kiuki mi ek room 11×12 fit ka banane ke liye soch raha hu , please bateiye
yes
@@LearningCivilTechnology thank sir 🙏💕
Sir,
Thank you for your excellent explanation.
You are really a fantastic Tuitor. But sir,
You did not mention the width of the base column ( substructure )
Sir, agar boundary wall 5" bricks wall ho to koyi dikkat hoga keya????
Thnku sir I agree with u sir g
Excellent
tie beam ke niche kya brick work kia jayega ya soil filling.
Nice info. 👏👏 . If 3"rcc wall 6'height with 6mm sariya at 1'×1' se banaye aur plenth beam coloum 13feet par de to kitna kharch hoga.
Sir 4 bigha plot ka BOUNDARY karna hai or uska estimate nikalna
Biharke Village area se hu
To Kitna charge kare hm.
Can we make same type of Boundary wall with 4 inch Brick wall thickness, Remain all we will keep same as you are suggesting?Asking regarding 🧱 Brick Thickness 4 Inch instead of 9 inch
Sirb thank you for plinth beam teaching . Accordingly you taught to use 12mm at top otherwise use all four rods 10mm apart frlom this rwo option , may we apply 12mm on all these four rods of plinth beam .
Sir compund wall ka column eccentric rakhna padega na?? Nahi to footing dusre ke plot mein ghus jayega na??
Yes
Sir me Assam ka hu .nurmel boundary wall drawing+hum get drowing keise kernahe .sir mereliye jorur video Dena.
as ur fan, ur videos are too good, sir. 🙏🙏
I've a small doubt that, if we do trepizoidal footing r rectangular r square footing for a boundary wall column, it will go into the beside site, sir..? for this what we can do sir..?
Sir here brick work load will act on plinth beam in downward direction as the beam is simple supported on two columns. I think higher dia rod shall be at bottom. If plinth beam constructed on simple pcc on earth then higher dia shall be at top. I am not a civil engg hence I may be wrong.
Siir, thank you for your teaching in utube , about boundary wall that ,being a lay man understand about the same .. May i request forr a small elaboration.
1. You taught column size 10 x10 inch.
2. Plinth beam size also 10 x 10 inch .
3.brick wall size also 10 x 10 inch.
In column and plinth beam the stirrup or tie up
The stirrup 7inch x 7 inch and concrete margin either side (all) 1 inch , this comes 9 inch x 9 inch , the remaining 1 inch can I assume as plastering of 1/2 inch (half inch) x 1/2 inch.
For brick wall it come to 9 inch x 9 inch for this also can i assume as plastering of 1/2 x 1/2 inch .
Thank you once again please.
Sir mai tia se upor khara beam dena nahi chahta kya problem aasakti hay
Sir column to column distance 20 feet kar saktay hn? Or Kia issi boundary wall ko in future rooms K back wall bana saktay Hain? I mean roof ka weight othaye ge wall?
Sir kya hum column ki size 9"x9" nhi rakh sakte hai......?
Sir what should be the grade of concrete used in column and beam
Thanks.sir.
Brother Mukesh. Pls prepare construction cost details for compound wall with pillars.
🎉🎉🎉
What material is used for coping
I have observed stepped compound wall at some sites.why is stepped compound wall required and how to take levels of such stepped compound wall. Pls clear my doubt
Thank you Sir
And layout par jab column ka vertical rod ka specing Kaise lete h is par ek video sir
Good
Sir what should be the grade of steel used in column and beam?
❤❤❤❤❤❤❤❤❤