ความคิดเห็น •

  • @barksofw
    @barksofw 3 ปีที่แล้ว +2

    Salamat sa tips idol gumagawa rin poh ako ng aking small house.

  • @arjundano7521
    @arjundano7521 3 ปีที่แล้ว +1

    Ang galing mo idol...dami ko natutunan sa vlog mo..

    • @acetvph7587
      @acetvph7587 3 ปีที่แล้ว +1

      salamat nmn ka lodi kahit effortless ang videos ko.. Trial p lang kung makapasa kay youtube.. at ngaung nakapasa na.. Pde n natin karerin pa ng mas maayos.. Shout out sau lodi Arjun Dano

  • @patrickobrien5367
    @patrickobrien5367 3 ปีที่แล้ว

    Good morning from lreland keep up the good 👍 work

  • @ParengKuyakoyTvTIPSIDEA1987
    @ParengKuyakoyTvTIPSIDEA1987 3 ปีที่แล้ว +1

    lets go sana maging mag kaibigan din tayo sir i love you construction works

  • @jessvista
    @jessvista 2 ปีที่แล้ว +1

    thanks sa video

  • @budgetarianboy3607
    @budgetarianboy3607 3 ปีที่แล้ว

    Boss, ano ba dapat i una pag buhos footing tie beam o column tapos tie beam na?

  • @power3545
    @power3545 3 ปีที่แล้ว +1

    Ang ganda

  • @oscaraddon1148
    @oscaraddon1148 3 ปีที่แล้ว +1

    Anong dapat na size ang footing ng pang two stories na bahay.

  • @benjiedomado2216
    @benjiedomado2216 3 ปีที่แล้ว

    Sir, matanong ko lng hindi ba kilangan ang concrete blinding?

  • @arnelmercado8014
    @arnelmercado8014 3 ปีที่แล้ว +1

    Bossing anong gamit mng splice sa mga Bakal mo

  • @luisquejano2423
    @luisquejano2423 3 ปีที่แล้ว +3

    Collum should be same 16mm and 12 mm stirrup

  • @norbertoparejr1650
    @norbertoparejr1650 3 ปีที่แล้ว +3

    Sir question po ano po ang right na lalim ng ground tie beam na naka connect sa mga column bago mag buhos?thanks you po....

  • @luisquejano2423
    @luisquejano2423 3 ปีที่แล้ว

    Wala bang epoxy coated na tie wire #16 at Yung spacing ng beam for ground is beside the collum should be 5pcs 5cm..15cm the rest and stirrup should be 12mm and vertical should be 16 mm for the 2story house

  • @ronieburce2820
    @ronieburce2820 3 ปีที่แล้ว +1

    2 storys ba yan ilang bakal ang gamit sa poste at ano sukat nyan 16mm ba?

  • @foursisters674
    @foursisters674 3 ปีที่แล้ว +1

    Ilang metro po ang space bawat poste sir?

  • @twopiecez5226
    @twopiecez5226 2 ปีที่แล้ว

    Saan unang maglagay nang dowels?? Sa tabi ba nang poste??

  • @michaelgu9907
    @michaelgu9907 3 ปีที่แล้ว

    Boss anong sukat ng poste mo pag nabuhusan? 12x16 ba?

  • @generdagdag4889
    @generdagdag4889 3 ปีที่แล้ว

    Wow bossing ,hirap talian nung mga stirrups ng tie beam nyan..mtatagalan pa

  • @martelrivera1135
    @martelrivera1135 2 ปีที่แล้ว

    Anong size ng bakal ang nasaposte nyo?

  • @geraldclarito
    @geraldclarito 2 หลายเดือนก่อน

    Sir, ask ko lang po. bahay ko balak kng i extend or pa gawaannko ng slab kaso wla syang footing tie beam ba yun sa pina ka groundfloor nya...bali po yung posti at saka hollowblock lng ang nkabaon mga 3 pirasong hollowblock kakayanin kaya yung slab ko sir?? buhusan kasi ng simento.

  • @noverdepaynos171
    @noverdepaynos171 3 หลายเดือนก่อน

    Tanong po idol, hindi po ba itinatali yong bakal ng tie sa bakal ng column?

  • @rudyfernando916
    @rudyfernando916 3 ปีที่แล้ว

    Good job gumagamit kayo ng vibrator. Kasi kahit first class ang concrete mix kung may ampao na parte ang buhos weak pa rin ang finish product.

    • @samarayan35
      @samarayan35 3 ปีที่แล้ว

      Ano solution pag nag aampao ung concrete sir?

  • @conradotescalajr2912
    @conradotescalajr2912 2 ปีที่แล้ว

    Anong sugat ng sterap ninyo boss

  • @jesselhoffmann2799
    @jesselhoffmann2799 3 ปีที่แล้ว

    Ilang floor ba ang pinapagawa? Kc kasaluyan nagpapatayo din ako nag start sila last 2 weeks. Gusto ko sana i share ang pictures while ginawa din nila ang footing or buhos. Mas gusto ko yang ginawa nyo.

  • @simpliciocamirino2271
    @simpliciocamirino2271 3 ปีที่แล้ว

    pa shoutout naman dyn,sir,baka pwede moakong gawing trabahate,hhehe,joke lang,sir.

    • @acetvph7587
      @acetvph7587 3 ปีที่แล้ว

      cge po.. no problem
      busy lng me ngaun sa mga project,. hnd n mkpagvideo
      pwede basta pagbilaoin hehe

  • @BoyHongkong
    @BoyHongkong 3 ปีที่แล้ว

    Magkano mag rent ng mixer per day ba?

  • @kennethclark7290
    @kennethclark7290 3 ปีที่แล้ว +1

    Unang part ng video bakit hindi ipinagsabay ang bottom at top bars? saka ilagay ang mga stirrups. Delaying tactics?

    • @chanrobspierre5840
      @chanrobspierre5840 3 ปีที่แล้ว +1

      diskarte q jan d q muna ifix lateral ties ng columns pra free moving ang main bars ng ftb.

  • @richardlei1391
    @richardlei1391 3 ปีที่แล้ว +1

    Sir ang vertical reinforcement ng poste meron concrete nakadikit dapat lilinisan yan bago buhusan if magbubuhos ng column.

    • @acetvph7587
      @acetvph7587 3 ปีที่แล้ว

      opo lalo na kapag makapal tlga nakadikit sa bakal

  • @mariaarroyo5223
    @mariaarroyo5223 3 ปีที่แล้ว +1

    👍

  • @bobbycaranto944
    @bobbycaranto944 3 ปีที่แล้ว

    Tama ba dinig ko ang mix mo sa concrete mixer, 3 gravel, 1 bag cement at 3 sand? Tama ba yung mix? Ang alam ko the right mix for M20 is 1: 1.5: 3, pls correct me if I am wrong. thanks.

    • @acetvph7587
      @acetvph7587 3 ปีที่แล้ว

      wrong

    • @larrysantos2246
      @larrysantos2246 3 ปีที่แล้ว +1

      Generally, if you want to meet the 3000PSI compressive strength ng concrete for slab, beam, footing at column, as a standard practice for building a house, you have to go to this mixture proportion of 1:2:3 0.5 which means, sa isang bag ng semento, 2 timba ng buhangin (Boysen 16 ltr. pail) at 3 timba ng graba G grade at 20 liters of water. 1:2:4 0.5 is also an acceptable ratio.

  • @marvinnumeral6011
    @marvinnumeral6011 3 ปีที่แล้ว

    eto layout na my 2nd floor? or ground lng?

    • @acetvph7587
      @acetvph7587 3 ปีที่แล้ว

      ground floor lng lodi

  • @manuelpondivida9337
    @manuelpondivida9337 3 ปีที่แล้ว +2

    Informative video👍... just a note, yong concrete mixture ratio (1-3-3) sa footing, sabi mo.... pwede na yan😢, so para sa akin , it sounds na meron pang mas matibay na concrete mixture ratio sa footing? Yong spacing nang tie beam stirrups, pwede naman cguro na 5cm (2”) or 10 cm fm end to end? Material costs lang cguro ang concerned kaya may spacing? Ty

    • @manuelpondivida9337
      @manuelpondivida9337 3 ปีที่แล้ว

      👍👍👍

    • @larrysantos2246
      @larrysantos2246 3 ปีที่แล้ว +1

      Generally, if you want to meet the 3000PSI compressive strength ng concrete for slab, beam, footing at column, as a standard practice for building a house, you have to go to this mixture proportion of 1:2:3 0.5 which means, sa isang bag ng semento, 2 timba ng buhangin (Boysen 16 ltr. pail) at 3 timba ng graba G grade at 20 liters of water. 1:2:4 0.5 is also an acceptable ratio.

  • @leimunoz1397
    @leimunoz1397 3 ปีที่แล้ว

    Sir pwede poh ba magtanong?

  • @nicoafilipinovlogdogiesand2548
    @nicoafilipinovlogdogiesand2548 3 ปีที่แล้ว

    sir yung bang mga intersection ng mga column at beam talagang hindi ito tinatali ? kunyari kahit sa 2nd floor ?

    • @acetvph7587
      @acetvph7587 3 ปีที่แล้ว +2

      tinatali po namin yan, Yung iba patong lang sa stirrups pag may hook..

  • @atromitos88
    @atromitos88 11 หลายเดือนก่อน

    gaano po kalalim footing sa 2storey at ano size ng parilya. ty po

  • @kniveskullchua5303
    @kniveskullchua5303 3 ปีที่แล้ว +1

    Tanung pra sa tie beam.. pwde b ang 4 na 12mm at 1-10mm lods? .20x.30 ?

    • @acetvph7587
      @acetvph7587 3 ปีที่แล้ว

      Pde nmn kung bungalow.. pero pg 2 storey gawin mo man lng RSb 16mm ang main bar

  • @berisopaul4939
    @berisopaul4939 3 ปีที่แล้ว +1

    boss ask ko lang po...ang size ba ng bakal mo eh 16x16? pwede po ba s pag 2 story 4 ang 16 x 16 abd ung dalwa n bakal 12x12

  • @BoyHongkong
    @BoyHongkong 3 ปีที่แล้ว

    Meron din bang narerentahan na concrete vibrator diyan sa pinas?

    • @mikenav5326
      @mikenav5326 3 ปีที่แล้ว +1

      Meron po sir. Uso naman yan dito.

  • @bronegsph6422
    @bronegsph6422 3 ปีที่แล้ว

    Idol ano standard nyo ng pagitan ng dowel mula sa poste para sa asentad Hindi po nabangit

    • @acetvph7587
      @acetvph7587 3 ปีที่แล้ว

      40cm vertical, 60mm horizontal para sa CHB laying or asinta.

  • @leoawag8515
    @leoawag8515 3 ปีที่แล้ว +1

    Ask Lang po sir puidi ba hawing flooring ang plywood na pholinoed board? Thank you p.o. sir

    • @richardlei1391
      @richardlei1391 3 ปีที่แล้ว

      boss matibay ang PHENOLIC BOARD kaso mas mahal kesa plywood pwede yan gawin flooring.

  • @norbertoparejr1650
    @norbertoparejr1650 3 ปีที่แล้ว

    Sir pwede po magtanong ask ko lng kung anong magandang lalim ng mga tie bar na naka connect sa mga column bago mag pouring ng cement

  • @anthonyvillanueva730
    @anthonyvillanueva730 3 ปีที่แล้ว +1

    Boss kailngan ba sabay sabay buhos ng lahat ng tie beam.thanks.

  • @rottweiler4125
    @rottweiler4125 2 ปีที่แล้ว +1

    Bagong viewer at bagong subscriber mo lodi,..sakto mga video's mo na sa tulad ko naghanap ng mga idea sa pag papatayo ng bahay ko..... Tanong ko lang lodi, sa 4 to 5 meters na layo nang COLLUM, (poste). Ok lang ba na gamitin [ 2pc na 16MM] and [4pcs na 12MM] na mga MAIN BAR para sa FOOTING TIE BEAM???AT ilang ang tamang kapal at lapad ng FOTTING TIE BEAM??.
    ....para yan lodi sa 2 STOREY HOUSE.. Thank you lodi ang and god bless..

    • @acetvph7587
      @acetvph7587 ปีที่แล้ว

      pwede nmn po pero much better kahit 4 ung 16mm and 2 lang ung 12mm panggitna

  • @jorpakzenduro9375
    @jorpakzenduro9375 ปีที่แล้ว

    Boss ano po size ng rebar sa footing tie beam? Salamat po.

  • @kennedymagtoto974
    @kennedymagtoto974 3 ปีที่แล้ว

    Hindi naka squala yung bar sa kanto sa may poste

  • @finnandcocoblogs
    @finnandcocoblogs 3 ปีที่แล้ว +1

    Ilang storey Yan boss?

    • @finnandcocoblogs
      @finnandcocoblogs 3 ปีที่แล้ว

      @@acetvph7587 maraming salamat boss god bless.

  • @jonknows5247
    @jonknows5247 3 ปีที่แล้ว

    Substandard halo nyo. Stirups panahon pa ni kopong kopong

  • @pekongpekong1106
    @pekongpekong1106 3 ปีที่แล้ว

    Ilang cm ba ang lalim nyan..at ilang floor po yan boss

    • @arneltamayo1746
      @arneltamayo1746 3 ปีที่แล้ว

      10x8meters sir tag 8pcs na 16mm ang poste..4mx4m ang agwat bawat poste ok lang ba.tas yung tie beam pwede 12mm na apat.tnx po

  • @joshuacanas9021
    @joshuacanas9021 3 หลายเดือนก่อน

    My klang kpa lodi dapat nlagyan mo mona yn ng grava bgo ka nagbakal para sa tie Beam

  • @edwarddelacruz9301
    @edwarddelacruz9301 3 ปีที่แล้ว +1

    Idol ask ko lng po balak ko po kasi magpagawa ng 2 storey maliit na area lng po 4x7 let say 30sqm. Bali ilang column po at ano po size ng bakal at combination sa isang column? Pati po sa biga.marami salamat po

    • @edwarddelacruz9301
      @edwarddelacruz9301 3 ปีที่แล้ว

      @@acetvph7587 marami salamat po idol mga magkano po kaya estimated cost labor at materyales kapag rough finished lng po fully structural with block works and plastered in and out. 30sqm x 2 total of 60sqm. Godbless idol napakaimformative ng content mo. Wait ko po reply mo idol.salamat

  • @isaiah6423
    @isaiah6423 2 ปีที่แล้ว +1

    11:54 dpat yung stirrups mo sir salitan.halos lahat nsa taas yung dugtongan

  • @nestorsalarda9765
    @nestorsalarda9765 3 ปีที่แล้ว

    Gud evening sir asklg ilan floor ba ung ginagawa nyo.at anung size ng.bakal nyo sa poste?salamat

    • @acetvph7587
      @acetvph7587 3 ปีที่แล้ว

      2 storey po.. 16mm bakal ginamit namin., min. of 6pcs each column

  • @lagriojoey9014
    @lagriojoey9014 3 ปีที่แล้ว +1

    Sir ask qo lng kung ilang feet ung lalim nang tie beam po sir

  • @bentambling5672
    @bentambling5672 3 ปีที่แล้ว +2

    Ang standard na templa 1:2:3 a 17 to 20 L ng tubig

  • @urieltadlas8641
    @urieltadlas8641 3 ปีที่แล้ว

    ano ang tamang spacing sa stirup ng pilar

    • @acetvph7587
      @acetvph7587 3 ปีที่แล้ว

      5sets na 5cm spacing simula sa parilya, 5 sets ng 10cm spacing..the rest 20cm

  • @markanthonyalbos1135
    @markanthonyalbos1135 3 ปีที่แล้ว

    Ilang bakal Ang nagagamit sa isang posts?.

    • @acetvph7587
      @acetvph7587 3 ปีที่แล้ว

      6pcs ng rsb 16mm

  • @Christian_calayag
    @Christian_calayag ปีที่แล้ว

    Boss baka naman😅😅

  • @roronecosia9562
    @roronecosia9562 3 ปีที่แล้ว

    Hello po bagong kaibigan po dto sir
    Itong ground lay out po Ba ai ganon din kng mag second floor? Please respect my comment
    God bless po at sa lahat.

  • @kennethcariaga5808
    @kennethcariaga5808 2 ปีที่แล้ว

    Sir tinatali ba ng alambre Yung dulo ng bakal papasok Don sa column? Dba Naka squal a po Yun? O ipapasok lng na parang Naka dikit sabay lagyan alambre? At same proce po ba Yun sa second floor ( slab)

    • @acetvph7587
      @acetvph7587 2 ปีที่แล้ว

      madali pong paraan ung itatali ung dulo ng bakal sa column para mailagay yung stirrups.. isang paraan p po ay binubuka ung stirrups sabay isisingit sa lahat ng bakal sa column para maipasok tapos sabay ang pagtatali sa bawat spacing na nakaassign sa bawat stirrups

  • @kennedymagtoto974
    @kennedymagtoto974 3 ปีที่แล้ว

    Mhirap mag tali dyan

  • @noracandari4522
    @noracandari4522 ปีที่แล้ว +1

    sir ok lang ba na 4 meters ang distance bet column footing?

    • @acetvph7587
      @acetvph7587 ปีที่แล้ว

      yes po .. pero meron mababago sa design ng structural po.. sa laki ng poste o biga at ano gagamitin bakal.. Hindi po ako structural engineer para masagot ng sakto ang katanungan nyo pero ang alam ko ay pwede po.. dpnde lng sa structural analysis

  • @NumberSense101_MervhieCalma
    @NumberSense101_MervhieCalma 3 ปีที่แล้ว

    Sa bungalow sir anu minimum size ng bakal?

  • @nestorgonzales3460
    @nestorgonzales3460 2 หลายเดือนก่อน

    Hindi ba pwede gunamit ng formula sa beam? Commonly used ay L/4.. para malaman Ang spacing..? .educate me sir...t.y .

  • @pablobanna6853
    @pablobanna6853 3 ปีที่แล้ว +1

    Ground beam ang tawag sa ilalim

    • @anglaruan6728
      @anglaruan6728 3 ปีที่แล้ว

      Hindi, Plinth or Tie Beam ang right term jan.

  • @waynekyu5377
    @waynekyu5377 3 ปีที่แล้ว

    Sir tanong po kung may existing na bahay ka na po tas balak mong mangpadagdag ng kwarto pano na po yung dugtongan ng tie beam sa dati ng nabuhusan na column?

    • @acetvph7587
      @acetvph7587 3 ปีที่แล้ว

      titingnan po muna natin structural ng bahay lalo na ang pundasyon.
      Kadalasan okay lng sa mga foreman gawin ang second floor pero in the real world of engineering let us consider many factors.

    • @waynekyu5377
      @waynekyu5377 3 ปีที่แล้ว

      @@acetvph7587 bungalow lang po siya sir

  • @PeterParker-hf8ok
    @PeterParker-hf8ok 3 ปีที่แล้ว

    Hello kuya, ok lang po ba may kalawang ung rebar or mas maganda galvanised po?

    • @acetvph7587
      @acetvph7587 3 ปีที่แล้ว

      okie nmn po.. wag lang po yung kalawang na kalawang na na wala nang tibay.. kadalasan po gawa lang po ng ulan, nagkakaroon ng kalawang pero hnd nmn po yung loob pa kinakalawang.., yung outer side pa lng kadalasan.. gawa ng moist

    • @PeterParker-hf8ok
      @PeterParker-hf8ok 3 ปีที่แล้ว

      @@acetvph7587 kayo po bay batangeuno?

    • @acetvph7587
      @acetvph7587 3 ปีที่แล้ว

      Hnd po. Tga quezon po ako

  • @jerrygonzales51
    @jerrygonzales51 3 ปีที่แล้ว

    questions: pwede ba sir iangat ang footing tie beam sa above o same natural ground level kasi me tambak ang bahay eh? (on engineering standard) kapag ba merong tie beam? kailangan pa ba ng wall footing? thanks po

    • @manuelpondivida9337
      @manuelpondivida9337 3 ปีที่แล้ว +1

      Yong yatang tie bean footing, yan ang magiging wall footing( laying platform of CHB)kc meron dowels?

    • @marloujaymomo4760
      @marloujaymomo4760 2 ปีที่แล้ว +2

      yung tie-beam general term yan. footing tie-beam kung nasa footing malapit ang kanyang location.. plinth beam naman kung naka lapag siya sa natural grade line.
      marami klase ng beam. pero ang main function niya is mag kabit sa column para mas maging kapit at less slender ang bawat column at maging matibay ang structure

  • @ronitomoto5589
    @ronitomoto5589 3 ปีที่แล้ว

    Mas maganda nga yung malapad ang buhos Sa footing? Lodz matibay

    • @acetvph7587
      @acetvph7587 3 ปีที่แล้ว

      oo nmn boss lodi\

  • @dep1912
    @dep1912 2 ปีที่แล้ว

    Hindi na ba popormahan ung tie beam? Ung pinaka lupa na ung porma?

    • @acetvph7587
      @acetvph7587 2 ปีที่แล้ว

      Opo para tipid.. Pero dun sa iba na malaki sasakupin ng buhos po ay need namin lagyan ng porma sa sidings.. dpende po

  • @lipongko2519
    @lipongko2519 2 ปีที่แล้ว

    sir, Plano ko pataasan ang ang bahay ko, row hause na pabahay pader Lang ang pagitan, 4x6meter, kung ang poste ko ay 6 kailangan pa ba Ng tie beam?

  • @urieltadlas8641
    @urieltadlas8641 3 ปีที่แล้ว

    gaano ka lalim sir ang foundation ng pilar

  • @richardlei1391
    @richardlei1391 3 ปีที่แล้ว +1

    boss di pwede tansa2x ang water cement ratio.

    • @gnidnoeled786
      @gnidnoeled786 3 ปีที่แล้ว

      Sa concrete mix ratio na 1:2:3 ang tubig dito ay 0.5, ang minimum na strength ng mix ratio na to ay 3,000 psi. Better kung nasa tamang mix ratio ang concrete at ang tubig ay tama.

    • @richardlei1391
      @richardlei1391 3 ปีที่แล้ว

      @@gnidnoeled786 boss ang 3,000psi ang mix ratio ay 1:3:3 ang 1:2:3 ang psi niyan ay nasa 4,000 ang 1:2.5 :5 ay 3,500psi ang 1:2:2 ay 4,500 psi at ang water cement ratio ng 1:2:3 ay nasa .45 to .50

  • @generdagdag4889
    @generdagdag4889 3 ปีที่แล้ว

    Eh kung malambot pa ung lupa at natitibag pa...tagal

  • @zackliwanagan8219
    @zackliwanagan8219 3 ปีที่แล้ว

    ano sukat ng footing tie beam mo sir at ano ang lalim nyan?

    • @zackliwanagan8219
      @zackliwanagan8219 3 ปีที่แล้ว

      @@acetvph7587 salamat bossing ng marami .more power to you!

  • @Ray_Marts
    @Ray_Marts 3 ปีที่แล้ว

    Hindi po ba sir baliktaran ang pagtakid nung square na bakal sa beam?

    • @acetvph7587
      @acetvph7587 3 ปีที่แล้ว

      nice question.. Maganda tlga baliktaran pero pde rin nmn hnd.
      Depende rin sa application lamang

    • @Ray_Marts
      @Ray_Marts 3 ปีที่แล้ว

      @@acetvph7587 salamat sa reply sir. . .

    • @acetvph7587
      @acetvph7587 3 ปีที่แล้ว +1

      @@Ray_Marts mas gawin natin ng tama kapag malakihang project ka lodi.. sasample-lan kita minsan.. next project namin para mas tama ipakita ko tlga at as is sa plan tlga

    • @Ray_Marts
      @Ray_Marts 3 ปีที่แล้ว

      @@acetvph7587 ok sir abang lang ako

  • @pogishow2833
    @pogishow2833 2 ปีที่แล้ว +1

    Pinahirap nyo lng trabaho nyo.

  • @haroldcapuno2518
    @haroldcapuno2518 2 ปีที่แล้ว

    Bossing,pwede ba gawing 20x30 ang column?bongalow style lng po ang bahay..

    • @acetvph7587
      @acetvph7587 2 ปีที่แล้ว +1

      oo nman boos lodi.. malaki n yun para sa bungalow

    • @haroldcapuno2518
      @haroldcapuno2518 2 ปีที่แล้ว

      @@acetvph7587 salamat boss sa reply.my idea na po akong nakuha sa video mo salamat....

    • @haroldcapuno2518
      @haroldcapuno2518 2 ปีที่แล้ว

      @@acetvph7587 boss,pwede pa kaya gawing 6x12 inch?medyo nagtitipid boss eh.ilang bakal kaya ang ilagay?12mm ang gamitin.bali 6 lahat.

    • @acetvph7587
      @acetvph7587 2 ปีที่แล้ว

      Pwede nmn boss lodi.

    • @acetvph7587
      @acetvph7587 2 ปีที่แล้ว

      Pde n kahit 4 n 12mm sa pinakang tipid.. wag nmn 10mm lng.. much better p din anim n piraso

  • @otse3329
    @otse3329 3 ปีที่แล้ว

    gaano kakapal ang footing?

    • @acetvph7587
      @acetvph7587 3 ปีที่แล้ว +1

      350mm

    • @otse3329
      @otse3329 3 ปีที่แล้ว

      @@acetvph7587 pag 10x10inches na poste ng fence bosing 350mm parin ang kapal ng footing? o pwd manipis konti? salamat.

  • @oliverumerez5531
    @oliverumerez5531 3 ปีที่แล้ว

    boss ano po ba ang standard na mixture 1*2*3 po ba 1*3*3 ano boss mas mganda gamtin

  • @arjiemeregildo1164
    @arjiemeregildo1164 2 ปีที่แล้ว +1

    Sir napansin ko lang mga anelyo yong hook nya dapat naka 135 degree

    • @acetvph7587
      @acetvph7587 2 ปีที่แล้ว

      korek po.. un po tlga tama

  • @marvinesteron9914
    @marvinesteron9914 3 ปีที่แล้ว +1

    nagtipid sa porma kaya lng dami waste sa concrete ng tie beam

    • @acetvph7587
      @acetvph7587 3 ปีที่แล้ว +1

      Pabor p nga po yan sa may ari kasi hnd nmn namin tinitipid yung sa concrete although natipid nmn namin ung porma. Mas tumibay nmn pundasyon kasi mas lumaki conrete cover

  • @udekk2r867
    @udekk2r867 3 ปีที่แล้ว

    anu size ng column

  • @marceengmatsing9787
    @marceengmatsing9787 3 ปีที่แล้ว

    Sir anong sukat po ng poste nyo?

    • @acetvph7587
      @acetvph7587 3 ปีที่แล้ว

      40cm x 25cm

    • @ronaldcorpuz3829
      @ronaldcorpuz3829 ปีที่แล้ว

      @@acetvph7587 nung sukat po ng tiebeam at no.of rebars den size ng rsb

  • @rogeliobicasjr3031
    @rogeliobicasjr3031 3 ปีที่แล้ว

    ansikip ng hukay nyo lodi popormahan pb yan o wla na

    • @acetvph7587
      @acetvph7587 3 ปีที่แล้ว

      wala n po lodi., yung hukay na po magsisilbing porma

  • @alejandrobandong
    @alejandrobandong 2 ปีที่แล้ว

    Ilang floor po gagawin

    • @acetvph7587
      @acetvph7587 2 ปีที่แล้ว

      2 palapag

    • @atromitos88
      @atromitos88 9 หลายเดือนก่อน

      may deck pa po ba yun sir or 2 floor lng @@acetvph7587

  • @rollijo
    @rollijo 3 ปีที่แล้ว +3

    Pare, sa lugar ba ninyo walang lindol? Ang Pilipinas ay nasa earthquake zone, sa aking pagkakaalam kung may lindol sa lugar na pagtatayuan ng structure ang dapat na gawing rebar (reinforcing bar) hooks ang recommended end hooks ng "Stirrups" (tawag sa beams or girders) at "Ties" (ang tawag para sa columns) ay 135° Seismic Stirrups and Tie Hooks both ends na iba sa na-install sa column ties sa video na combination ng 90° at 180° kasama na rin sa video ang footing tie beam "stirrups" na 90° na dapat 135° hooks. Ang "16mm" main rebars ng footing tie beam na 90° bend ay dapat (for 16mm rebars only: 12d + 1/2 of 95mm + bar diameter = 250mm (10 inches) total hook length minimum). Refer to STANDARD HOOK DETAILS
    in accordance with ACI 318 Building Code and CRSI (Concrete Reinforcing Steel Institute) Tables.

    • @arnolfoaragones7415
      @arnolfoaragones7415 3 ปีที่แล้ว

      ilang laki ng poste ang for 2nd and 3rd flr. at distance ng bawat poste

    • @acetvph7587
      @acetvph7587 3 ปีที่แล้ว

      thanks po sa info.. salamat po..mkakatulong yan.,

    • @acetvph7587
      @acetvph7587 3 ปีที่แล้ว

      ikaw lodi ko ngaun sir

    • @ginengineerkamote3815
      @ginengineerkamote3815 ปีที่แล้ว +1

      Hindi ba dapat ang minimum hook ay kung ano mataas sa 3db+75 at 9db?

  • @lyndonpaullee8830
    @lyndonpaullee8830 3 ปีที่แล้ว

    Kalodi Sir, Question lng. If 12mm-6pcs/10mm Stirrups kada Poste (6pcs na poste) kaya nya po ang load sa Tie beam sa taas na 16mm.
    *4x10 po size ng bahay.

    • @acetvph7587
      @acetvph7587 3 ปีที่แล้ว

      gawin nyo n po 16mm mga bakal na gagamitin sa poste.. wag n po 12mm lang kung para sa 2 storey.. kung one storey lang nmn okie n po ung 12mm

  • @ailynalino7636
    @ailynalino7636 3 ปีที่แล้ว

    Boss ano sukat ng poste nyo gusto ko gayahin kasi

    • @acetvph7587
      @acetvph7587 3 ปีที่แล้ว

      25cm x 40cm po yan

  • @pong3753
    @pong3753 ปีที่แล้ว +1

    Sa ating footing kailangan malakas xa na kayang buhatin ang lahat ng load ng bahay gaya ng dead load ang live load at kailangan atlist 3000psi or higit pa sana ang lakas or 21Mpa sana ganun din ang columns.. mali po yung buhos nyo na 133,.. mahina po yan... Ok sana 124 or 123....

  • @bukidloverfamily9451
    @bukidloverfamily9451 2 ปีที่แล้ว

    Master baho pa Ako naka panood sa vlog my ta nong lang Ako sa halege Ano Ang sokat nang ring bar

    • @acetvph7587
      @acetvph7587 2 ปีที่แล้ว

      yung ring bar po ay column ties tawag kapag sa poste.. sa biga nmn po ay stirrups. bale 15cm x 25cm sukat ng ties namin para sa 25cm x 35cm n poste

  • @manuelpatawaran5504
    @manuelpatawaran5504 3 ปีที่แล้ว

    One factual observation is... Walang gravel sa ilalim ng tie beam...4 inches minimum and tamper Dapat....

    • @acetvph7587
      @acetvph7587 3 ปีที่แล้ว

      it depends again the scenario or yung status ng lupa. Matigas n po kasi yung lupa kaya no need for gravel bedding unlike dun sa talagang maputik na kahit may gravel bedding na ay nalubog pa. Watch my next episode and makikita nyo po ang tunay at matibay na paggawa ng pundasyon. Meron rin po kayo makikita dun gravel bedding na 4" ang thickness bago buhusan ng konkreto. Watch my Episode 5B . Ito po yung link
      th-cam.com/video/honJKeTST4s/w-d-xo.html

    • @manuelpatawaran5504
      @manuelpatawaran5504 3 ปีที่แล้ว +3

      @@acetvph7587 pls... don't be offended..The proper terminology is soil density..Walang scenario o status ang lupa..Ang purpose ng gravel under foundation has nothing to do with compression load...It's all about water irrigation or drainage... Remember... concrete is a porous material... meaning....it absorbs water or moisture...And water promotes rebar rusting...Ang maling akala ng maraming pilipino..Ang bakal ay hindi kinakalawang pag nakabaon o lubog sa semento... This is the reason why Harrison plaza is about to be demolished after 50 years as stated in building code of the Philippines...The simplest way to test soil density is.....by using SOIL LOAD TESTER...A more advanced method is using GPR...or ground penetrating radar...

  • @MegaCelman
    @MegaCelman 3 ปีที่แล้ว +1

    3

  • @davejhay4109
    @davejhay4109 ปีที่แล้ว

    Ip structure analysis nyo sa engineer kse malalakas ang earthquake sa bansa nten nowadays pag daring pa ng draribv na panahon

  • @rowelmabazza1052
    @rowelmabazza1052 3 ปีที่แล้ว +1

    Dapat binanggit mo kung 2nd floor yan kc kapag 2nd floor yan mali ung pagkabit sa mga bakal.

    • @acetvph7587
      @acetvph7587 3 ปีที่แล้ว

      Structural engineer po b kayo?

  • @ronaldmendoza3594
    @ronaldmendoza3594 3 ปีที่แล้ว

    Ka lodi ano sizes ng rebar sa footing tie beam mo salamat ka lodi sa sagot keep safe and God bless

    • @acetvph7587
      @acetvph7587 3 ปีที่แล้ว +1

      16m rin po pero 4 pcs lng

    • @ronaldmendoza3594
      @ronaldmendoza3594 3 ปีที่แล้ว

      @@acetvph7587 ka lodi salamat sa sagot keep safe and God bless

  • @urieltadlas8641
    @urieltadlas8641 3 ปีที่แล้ว

    sir anu ang tamang sukat sa ground beam, at anung sukat din sa 2nd floor beam, pkisagot sa chat or text sir

    • @acetvph7587
      @acetvph7587 3 ปีที่แล้ว

      25cm x 40cm po ginawa na in sa ibaba,., 20cm x 30cm sa taas

    • @richardlei1391
      @richardlei1391 3 ปีที่แล้ว

      Lodi di ba sa footing tie beam mas malapad ang width kesa sa depth?

    • @anglaruan6728
      @anglaruan6728 3 ปีที่แล้ว

      Depende yan sa structural analysis ng engineer. Wlang standard na size na sinusunod sa mga Beams, footings at columns. Magvavary yan depende sa loadings, design at external factor ng bahay na itatayo.

  • @manuelpatawaran5504
    @manuelpatawaran5504 3 ปีที่แล้ว +1

    It's better to use BI wire compared to GI wires...

    • @acetvph7587
      @acetvph7587 3 ปีที่แล้ว

      yes but G.I. Wires are commonly use..

    • @manuelpatawaran5504
      @manuelpatawaran5504 3 ปีที่แล้ว

      @@acetvph7587 BI has a higher tensile strength compared to GI..GI wires has been commonly used in the Philippines for almost 100 years..yet other countries have been upgraded to BI wires...Sa kawad pa lang yan na pangtali... Wala pang fiberglass rebar at basalt rebar sa pinas...

  • @oceantv.21oceanbase65
    @oceantv.21oceanbase65 2 ปีที่แล้ว

    Mali nmn yung spacing

  • @EuropeTruckersPinoy
    @EuropeTruckersPinoy 3 ปีที่แล้ว

    Matamlay panoorin, wlang tamang info... pero pinanood ko pa rin pra makakuha ako ng idea kpg nagpatayo ako ng bahay ko...

  • @srmontejojerameel4627
    @srmontejojerameel4627 3 ปีที่แล้ว

    Kuyakoy mga tao araw yan

    • @acetvph7587
      @acetvph7587 3 ปีที่แล้ว

      ok lng po yan kalodi meron nmn time frame yan sinusunod.. The best yan sakin