Identificare defect instalație electrica in varianta 1P și 1P+N

แชร์
ฝัง
  • เผยแพร่เมื่อ 28 พ.ย. 2024

ความคิดเห็น • 61

  • @dumitrustelian1855
    @dumitrustelian1855 3 หลายเดือนก่อน +2

    Mulțumim frumos pentru explicații, Spor și sănătate multă

  • @vincegaspar1677
    @vincegaspar1677 ปีที่แล้ว +5

    Multumim pentru demonstratie,ati explicat foarte bine,trebuie aplicat in teren .😊👍🏻

  • @alexandrubondaret7076
    @alexandrubondaret7076 10 หลายเดือนก่อน +2

    ❤Felicitări! Un video bun informativ! 😉👏👏👏

  • @cristianciumas3217
    @cristianciumas3217 ปีที่แล้ว +2

    Foarte utilă această demonstrație și ușor de înțeles! Mulțumim! Spor la treabă!

  • @radutmariuscatalin6097
    @radutmariuscatalin6097 ปีที่แล้ว +1

    Mulțumim mult pentru prezentare Adi!

  • @ionelciprian
    @ionelciprian ปีที่แล้ว +1

    Foarte util video multumim si spor la treaba Adrian 👍👍👍

  • @marianene9009
    @marianene9009 ปีที่แล้ว +1

    Superb mii de mulțumiri

  • @n55m6a7
    @n55m6a7 ปีที่แล้ว +1

    Prezent la lectie....👍👍⚡⚡

  • @ionelrusu7417
    @ionelrusu7417 ปีที่แล้ว +1

    Super ajutător!!!!

  • @ivansevera2735
    @ivansevera2735 ปีที่แล้ว +1

    de ce nu imi plac monopolarele complica lucrurile,! Felicitari pt prezentare !!!

  • @liviuprecup4447
    @liviuprecup4447 ปีที่แล้ว +2

    Mulțumim. Sănătate....

  • @payatsmihai1309
    @payatsmihai1309 4 หลายเดือนก่อน +2

    Bună ziua. Se accepta și femei la cursul dumneavoastră?

  • @marcelmorar7658
    @marcelmorar7658 ปีที่แล้ว +2

    Cred ca ar trebui și Ștefan sa vadă acest clip și toți care sunt adepți monopolarelor

  • @poppop3173
    @poppop3173 ปีที่แล้ว +1

    Salut Adrian. Construiesc casa și o sa am Pe parter 25 prize plus iluminatu și pe etaj poate tot la fel.cit ar costa doua tablouri electrice

  • @dumitrustelian1855
    @dumitrustelian1855 3 หลายเดือนก่อน

    Bună ziua, la mine acasă când ating nul cu pe, sare curentul pentru toată casa,,, cum a-ți alimentat planșa? Mulțumesc

  • @ionelr1172
    @ionelr1172 ปีที่แล้ว +1

    Din punct de vedere al electricianului, cum recomandati sa fie peretele inaintea de realizarea intalatiei electrice la casa noua: tencuit sau netencuit (la rosu)?

    • @alarmelectricsistem
      @alarmelectricsistem  ปีที่แล้ว +2

      Nu este o regula însă ca totul sa fie perfect ar fi indicat ca infrastructura sa se facă la rosu iar dozele sa se monteze la gri. Asta dacă pereții nu sunt drepți iar dozele montate la rosu ar rămâne mult in interior.

    • @ionelr1172
      @ionelr1172 ปีที่แล้ว

      @@alarmelectricsistem legat de circuitul separat pentru cuptor electric, plita electrica si pompa caldura aer-apa 8KW, de cat sa fie grosimea firelor? 4mm2 pt cuptor si plita si 6mm2 pt pompa caldura?

    • @modorangeorge4991
      @modorangeorge4991 4 หลายเดือนก่อน +1

      @@ionelr1172 Pompa aia nu-i trifazata ? Ca 8KW pe monofazat cam greu.

    • @ionelr1172
      @ionelr1172 4 หลายเดือนก่อน

      @@modorangeorge4991 6kw monofazat

  • @fokozuynen2048
    @fokozuynen2048 ปีที่แล้ว

    Buna ziua , am o intrebare cu care ma confrunt de ceva timp. Cum fac instalatii de apa calda in apartamente sau montez sisteme de aer conditionat se intampla sa dau cu bormasina gauri in locuri unde nu ar trebui sa fie fire electrice si bam acolo sunt :) . In multe cazuri le montez o doza si le pun mansoane iar o reparatie de genu asta costa foarte mult din punct de vedere al materialelor multi propietari zic lasa domne dai cu banda izolatoare si lasa-l asa in zid. O solutie mai ieftina sub 200 lei nu am gasit. Daca aveti timp sa faceti un clip macar sa le dau exemplu de la cineva care stie ca daca le zic eu ca e periculos cu banda izolatoare in zid zic ca vreau sa ma dau inginer.

  • @DumitruSimte
    @DumitruSimte 4 หลายเดือนก่อน +1

    Am găsit într-o baraca metalica o inst. Super făcută pin 78..iti dispare chefu de meserie

  • @simicidoru9525
    @simicidoru9525 ปีที่แล้ว +1

    👍👍

  • @constantinesculaurentiu2181
    @constantinesculaurentiu2181 ปีที่แล้ว +2

    Si eu sunt adeptul sigurantelor bipolare,dc sa ii intrerupi omului toata casa?pt o reparație minusculă.tocmai sa decuplezi circuitul in care se intervine,restul rămânând functional!

  • @emilenache1537
    @emilenache1537 ปีที่แล้ว +1

    👍

  • @georgecurelea3247
    @georgecurelea3247 ปีที่แล้ว

    Salutare Adrian ,cei de la enel mi-au pus diferential pe general C32 RCBO 0,3A este bun? Daca nu ce-mi recomanzi? Mulțumesc!

    • @ioanmuntean2308
      @ioanmuntean2308 11 หลายเดือนก่อน +1

      Nu se pune RCBO general numai pe circuite dedicate.

    • @modorangeorge4991
      @modorangeorge4991 4 หลายเดือนก่อน +1

      @@ioanmuntean2308 e vorba de ala din bransament ce oricum nu-l poti schimba tu

  • @cornelmihalache5539
    @cornelmihalache5539 6 หลายเดือนก่อน

    in priza ptr centrala termica unde trebuie sa fie plusul

    • @modorangeorge4991
      @modorangeorge4991 4 หลายเดือนก่อน +1

      Nu prea exista "plus" in circuitele de curent alternativ cum e cel de la retea. Nu te pricepi nu umbli.

  • @hexanlaci
    @hexanlaci ปีที่แล้ว +1

    Buna! Am cumparat cablu CYY-F 3x2.5 , il folosesc la toata instalatia din casa la prize. Peste cateva zile termin si cu impamantarea tarusi-platbanda etc... Problema mea este ca imi apare curent pe firul verde la prize ,degeaba desfac legaturiile la doze! 40 ..., 50 v Mentionez ca folosesc circuite dedicate la fiecare incapere separat...! nu conteaza ca nu e nimic bagat in priza.,tot apare curent... Sa schimb toate cabluriile pe cabluri NYM-J ? Va rog scrieti-mi ceva raspuns.... multumesc

    • @christiand7804
      @christiand7804 ปีที่แล้ว +2

      Salut, termina priza de pamant si masoara dupa.

    • @lexaaxel926
      @lexaaxel926 6 หลายเดือนก่อน +2

      Se numeste current Indus! Cand firul GV - impamantare va fi legat la o impamantare , fenomenul va dispare!

  • @marianacanal8415
    @marianacanal8415 ปีที่แล้ว

    cum va pot contacta

  • @liviuc4915
    @liviuc4915 ปีที่แล้ว

    Eu acuma finalizez o căsuță și am o problemă cu, curentul îmi bate siguranță de afară, când bag flexul, rotopercutorul, iar dacă încerc să fac material, dacă merge malaxorul în gol nu sare dacă îl bag în material și imediat sare, aceiași priză merge cu frigiderul, filtru de cafea, am adus flex nou, rotopercutor nou la fel sare, care ar fi problema.

    • @marianionescu3592
      @marianionescu3592 ปีที่แล้ว +2

      Posibil sa fie curba B. Schimba cu curbă C

  • @sukycatana7661
    @sukycatana7661 ปีที่แล้ว

    Buna ziua , de ce imi sare generalul dupa un anumit timp ,3-4 saptamani -2 -3 luni ...?

    • @angellino1
      @angellino1 ปีที่แล้ว +2

      Defect latent....momentan

    • @sukycatana7661
      @sukycatana7661 ปีที่แล้ว

      @@angellino1 multumesc ,ce e de facut ?cum pot rezolva defectul ?

    • @angellino1
      @angellino1 ปีที่แล้ว +1

      @@sukycatana7661 trebuie investigat,eventual schimbat cablajul/traseul

  • @Radu-11-11
    @Radu-11-11 ปีที่แล้ว

    Bună ziua , un colaborator pe Iași cu probleme la o siguranță diferentiala care pica la ploaie. Mulțumesc

    • @andreicojocaru350
      @andreicojocaru350 ปีที่แล้ว

      Unde in iasi?

    • @nituvasile1751
      @nituvasile1751 ปีที่แล้ว

      Face condens,umezeala,si-n cazul aista suna un electrician.

    • @Radu-11-11
      @Radu-11-11 ปีที่แล้ว

      @@nituvasile1751 am sunat nu au găsit problema doar pe priza jumătatea casei

    • @Radu-11-11
      @Radu-11-11 ปีที่แล้ว

      @@andreicojocaru350 în Iași zona bucium

    • @andreicojocaru350
      @andreicojocaru350 ปีที่แล้ว +1

      @@Radu-11-11 problema este la o priza exterioara ceva lampa din exterior

  • @enceanuadin1253
    @enceanuadin1253 ปีที่แล้ว

    In 2 saptamani am gasit Pe inversat in priza cu N si a doua N cu PE lipite pe traseu....... aaa ca poti gasi orice...

  • @gabrielgherman2562
    @gabrielgherman2562 ปีที่แล้ว +1

    „ ... Schimbați pozițiile întrerupătoarelor... ”
    Și dacă avem circuit cap-scară ? 😁🤪

    • @modorangeorge4991
      @modorangeorge4991 4 หลายเดือนก่อน

      Doar unul din ele e de ajuns

    • @gabrielgherman2562
      @gabrielgherman2562 4 หลายเดือนก่อน

      ​@@modorangeorge4991
      Asta dacă știm de existența lui.

  • @creaturysrunnerbikers7693
    @creaturysrunnerbikers7693 ปีที่แล้ว +1

    👏👏👏👏💖💖👍🫡

  • @vlad-fx2pe
    @vlad-fx2pe ปีที่แล้ว +3

    Dupa curs direct la oftamolog cu becurile alea in ochi 😂

    • @florind.5711
      @florind.5711 ปีที่แล้ว +2

      Percepția umana este diferita față de focalizarea generala a unui telefon sau camera

  • @gabriel-liviualexandru421
    @gabriel-liviualexandru421 ปีที่แล้ว +1

    Super, dar mai omorât frate cu acel " bineînțeles" cred că ți-a devenit tic verbal. Ai grija pe viitor.

  • @nituvasile1751
    @nituvasile1751 ปีที่แล้ว

    Su-ni un preten, bineînțeles sa fie electrician nu (electro)zugrav!😂

  • @fn1571
    @fn1571 ปีที่แล้ว

    Buna ziua, am un bec care a funcționat ani de zile intr-o anexa si de o luna nu mai funcționează ,nu am intervenit cu absolut nimic asupra instalației electrice , cum se poate remedia aceasta problema