HMI04. Beckhoff PLC HMI - Main Screen, Header, Screen Navigator, and Tc3PlcHMI.exe (4/6)

แชร์
ฝัง
  • เผยแพร่เมื่อ 28 ม.ค. 2025

ความคิดเห็น • 12

  • @alexchala7035
    @alexchala7035 6 หลายเดือนก่อน

    Another graewt video

  • @Cartunerke
    @Cartunerke 4 ปีที่แล้ว +1

    Hello, I have a question about the time and date in the header. What is the format and variables for it to get it on the HMI and where do you have to define it? Thank you in advance!

    • @electricalautomation
      @electricalautomation  4 ปีที่แล้ว +1

      Good Question, and the time and date showing at the header will be the next video in this playlist, I would launch it in two weeks

    • @Cartunerke
      @Cartunerke 4 ปีที่แล้ว

      @@electricalautomation thanks! I'm watching all your tutorials about Beckhoff (actually will be using the HMI server in stead of the HMI PLC edition but variables will be the same)

  • @duyanhngo4987
    @duyanhngo4987 ปีที่แล้ว

    how to make error display table?

  • @deividasnaudzius6504
    @deividasnaudzius6504 4 ปีที่แล้ว

    Hello thanks for video. i have a problem maybe you can help me. I get error after dowloading program to plc, and plc goes on config mode (blue led). Error is this
    Event Type: Information
    Event Source: Application Popup
    Event Category: None
    Event ID: 26
    Date: 12/21/2020
    Time: 7:01:04 PM
    User: N/A
    Computer: CX-171602
    Description:
    Application popup: Tc3PlcHmi.exe - Unable To Locate Component : This application has failed to start because OPENGL32.dll was not found. Re-installing the application may fix this problem.
    OS on PLC WinXP Embedded Standart , And TwinCAT 3.1 4020.39

    • @electricalautomation
      @electricalautomation  4 ปีที่แล้ว

      Hi Deividas, how are you doing. As you shown, your Beckhoff controller is TwinCAT 3.1 4020, it is an old version. Are you using the same version (TwinCAT 4020) on your laptop for the programming? Did you use higher version program your project. Take care that "The ini. file is located in the folder C:\TwinCAT\3.1\Components\Plc\Tc3PlcHmi for builds older than 4022.0 and in the folder C:\TwinCAT\3.1\Boot\Plc for build 4022.0 and newer." pls check the link infosys.beckhoff.com/content/1033/tc3_plc_intro/136113291.html?id=892211445079357022

    • @deividasnaudzius6504
      @deividasnaudzius6504 4 ปีที่แล้ว

      @@electricalautomation tx for answer. Programming laptop have TwinCat 3.1.4024.11, so i need manualy adapt ini file on the target PLC?

    • @electricalautomation
      @electricalautomation  4 ปีที่แล้ว

      @@deividasnaudzius6504 The revision doest match may the major reason. You need to install Remote manager on 4020 in your laptop. please check the video th-cam.com/video/tBCH6YrYCOI/w-d-xo.html. Download the remote manager "TC31-RM-Setup.3.1.4020.56". Your laptop and your beckhoff controller must be the same version.

    • @deividasnaudzius6504
      @deividasnaudzius6504 4 ปีที่แล้ว

      @@electricalautomation Thank You i wil try today

    • @deividasnaudzius6504
      @deividasnaudzius6504 4 ปีที่แล้ว +1

      @@electricalautomation Thanks to you,
      I fixed it!