Best Zone of Lapping in Beam | बीम का सरिया का लैपिंग कहाँ देना है?
ฝัง
- เผยแพร่เมื่อ 4 ต.ค. 2024
- बीम का सरिया का लैपिंग कहाँ देना है?
L/2 & L/3
1. 7 Big Mistakes in RCC Beam | 7 ऐसा ग़लती जो बीम बांधते समय होता है?
• 7 Big Mistakes in RCC ...
2. 8 Big Mistakes in RCC Column | 8 ऐसी गलती जो पिलर बांधते समय होती है?
• 8 Big Mistakes in RCC ...
3. Best Zone of Lapping in RCC Slab | स्लैब के सरिया का लैपिंग कहाँ देना है?
• Best Zone of Lapping i...
4. Best Zone of Lapping in Beam | बीम का सरिया का लैपिंग कहाँ देना है?
• Best Zone of Lapping i...
5. What is Joggle? Why we Bend a bar while Lapping? सरिया का लैपिंग में जोग्गल क्यों देते है?
• What is Joggle? Why we...
6. Reinforcement Lapping zone of Column for Residential Building | कॉलम में सरिया का लैपिंग कहाँ देना
• Reinforcement Lapping ...
7. Big Mistake of Column Top Surface at Construction Site
• Big Mistake of Column ...
8. Big Mistake in Formwork | Shuttering Failure at Construction Site |
• Big Mistake in Formwor...
#BeamLapping #LappingLength #CivilEngineering
YOUR TEACHING IS FEEL LIKE OUR FRIEND EXPLAIN THINGS TO US. SIMPLE & NORMAL LANGUAGE. GREAT. ALL THE BEST.
thank you
पकाते बहुत हो भाई
Sir ko kitne log pasand karte hai ❤️❤️❤️ good night sir
नमस्ते सर 🙏🙏....,
आप बहूत बारीकी से हर चीज समझाते है. सच कहू तो आप एक ऐसे इंजीनियर है जो, हम जैसे जूनियर इंजीनियर वालों केलीए आप एक गूरु है. और भी you tube पर चैनल है जो Construction site के बारेंमें जानकारी देते है. लेकीन आपका जो सिखाने का तरीका है वो बहूत ही आसान शब्दों में होता है. मतलब आपकी एक अलग ही theme है. और आप हर vedio के अंत में एक डायलॉग बोलते है वो मूझे बहूत पसंत है.
मैंने सिविल डिप्लोमा किया है और मै महाराष्ट्र से हू. आपके बनाए व्हिडीओ पर में self study कर रहा हू.
भाई आप बहुत अच्छे तरिके से समझाते है.ज्ञान देनेसे बढता है.आपके सब विडिओ बहुत ही अच्छे होते है.धन्यवाद दिपक कुमारजी🙏
Thanks
Love you sir aap ke samjhane ka niyam bahut bahut achchha hai
Thank you Sir for Best knowledge
Most welcome
Bahot achchha jankari di sir aap ney Sukriya sir
Bahut khoob deepak sir yeh aur eek daut pura huwa aaj thank you so much sir
Mujhe 3flour tk house bnana h lekin ek samsya aa rhi h pichhe Me lagabhag 3feet pani lga huwa h 22/55 ka plat h kaise bnau
Thank you sir 🙏
बहुत अच्छा
Thank you so much brother. ..
Love you ....great knowledge.
Thanks and welcome
Sir ek video house cons k duration p bhi bana do column , wall cons , rcc etc
सर, कलम का लैपिंग टाई बीम और वाल बीम के बीच दिया जा सकता है क्या?
अगर नियम के अनुसार L/2 के आस पास देते हैं तो बहुत सारे कट पीस निकाल जाएगा और यह 16 mm बार के कट पीस और कहीँ इस्तेमाल भी नही होगा। सर कृपा हमे मार्ग दर्शाएँ।
good sir
Sir bottom bar mey l/8 mey nahi hoga sir... Top bar mey l/3 rakhne se kya hoga sir
Sir ko vidio ke last mai acha lagta hai
Very helpful video sir
thanks
ठीक बा
Sir lohe ki saria me Jung lag gaya hai, pls koi achchha rust remover chemical batayiye, jo turant rust clean kar de, or market me mil sake...pls...
But in IS 13920-2016, LAP SPLICES shall not b provided
A) within joints
B) within a distance of 2d from joint face
C) within a quarter length of member where flexural yielding may occur under the effect earthquake force
Beam ka cuting slab main use..???
Excellent video sir. Thnx a lot
Deepak Kumar ji Jay bholenath
19*14 ka hol hai to Kitna Bim Dena pade
is code ka refrence bhi dijiye
Sir Jamin chat par sariya kitne inch bandhna chahiye hai
Very good sir
Sir mujhe ye batao lo hum bol me L dete hai wo up dawn rakha chahiye ya left right au kou plz batao
I think as per is 13920 the lap should not provided within the quarter length of the member...as you are saying lap can be provided near to support.....please correct doubt...
Deepak sir steel construction se ghar kaise banae is per bhi video banae please
Thanks Sir
Brother 25X40 house plan jo shop attached wala design batayen
Sir , 14x14 k hall me slab pe kitne mm ka saria dena chahiye?
10mm & 8mm
Sir ak baat puchne h mra chhat m beem 12 m ke char se 4 char ka beem bana h koi problem nahi hai na sir ye bataye mra jamen 5 dur m bana h
As pr is code bataya hai kya sir?
Sir , aap hero ho
thanks
Sir 5year phle 800sqft ghr ka construction Hua h so ab unko upr me construction I mean bedroom hall bathroom kitchen bnvana h.. So iske lie construction ka starting ka procedures explain krne Vala video bnao n... Argent need h... Kese start krenge ky bnaenge ky cheej krna h un sb k bare me...
Actually TH-cam me is topic k upr Ak b video ni bna h nd jo video bne h unme direct g+1 ka construction aksath dikhae h
Very very grateful video sir Ji, dear can I provided the crank bar or speser bar lapin zone,
Sorry sir, dear sir likhana tha
yes
Sir lapping nhi samajh paye. Koi vedio real sight p karte hue dikhaye.
Sir ji flat slab house pe video banaiye sir ji aur flat slab house banne ke disadvantages and advantages bataiye
Sir some videos show L/4 L/3 which is correct
Repert plz clear fild me dekhaea
Superb ❤
Thanks 🤗
Top and bottom me steel me 3bar hai aur lapping alternet hona chahiye ya nahi 3/2 bar me aur l beam ka measurmt w - 1ft aur h- 2ft hai 16 ka bar l kitna hoga sir sir aap ka number chahiye
Super sir
sir mene v kl apna ghr m aise diye pr tikedr bolta h glt pr fir v. hm aise dlwa. diye jaise ap bole
Sir thank you
Sir ji Extra Bar ko bhi Ld provide karte hai kiya???🤔🤔🤔🤔
yes
Sr bottom me Column face se 2d distance par lap dete hi [ where d= effective depth of beam ] as per IS-13920-1993 in bottom part, lap length=50d
Good 👍
Thanks
Sir ,1 fhit bay 1 fhit motai aur 10 fhit hait ho to kitna score fhit hoga
Hame bataiye sir ,
Kya hum 16 mm tmt bar mein 3 feet lapping dekar welding kar sakte hai?
Bottom me lapping l/3 ...ke andar nhi........ As per is code... Column face se 2d distance napiye.... Fir 2d distance ke bad lap dijiye... Where d=effective depth of beam
sir builder wale makan me dono side beam aur piller common hota hai. to agar padosi ne first fllor bana liya aur hamare liye sariya beam aur slab se nahi nikala tab hum apna first floor ka slab kaise bana sakte hai
Sir , I have one question for you beautiful learning video , is it possible to have different lapping zone in same beam , like is it possible that if i am doing overlap in any beam so can I have different upper lapping zone difference lower lapping zone !! Kindly reply, thank you sir .😊
Send me sketch drawing
Extra bar aur creank bar konse better hai
Last mein sir aap thoda side ho jao, SCREEN SHOT lene mein prob hota hai...
please learn the negative B.M and positive B.M zone.
Latak Bim me colum kaise dale
सर क्या अगर मकान का दीवाल अगर आधा हम इस फेस से जोड़े ओर आधा दूसरे फेस से तो क्या दिक्क्त आता है
Very interesting.
Glad you think so!
Kethni fit pr dina hi hum log eng nahi hi sr
Cantiliver m lapping zone kaha hota hai
Bahut site Par koi nhi deta h sir jee..
Site Par itna dimag koi nhi lagata h
पिछली बार की वीडियो में आपने बताया था कि बीम के बॉटम में ओवरलैप L/6 एवं टाप में L/2 रखा जाता है लेकिन इस बार आपने बॉटम में ओवरलैप L/3 बताया है ?
Laping dena jaruri he kya,nahi dene se kya problem face karna pad sakta he
Huu
Beam me Laping dete time Sariya ko L bana dena he ya wese hi
sir whatsapp kiye कोई replay nahi kiye ...
36m ka sariya Bina Kate use kar sakte h kua
haa
सर आपसे 2 बात पूछना था
मेरा घर धलाई होने वाला है
सीमेंट ACC F2R का कैसा होगा
और
बालमुकुंद का रोड़ मेरे एरिया मे ज्यादा बालमुकुंद का रोड़ ही मिलता है बिहार का बेतिया जिला
प्लीज़ सर जवाब दिजीए
अच्छा होगा या कुछ बदलाव करना होगा
देहात एरिया है
ok
सर नमस्कार
HELLO SIR , what is l/4 L means length then 4 ?
Do Column ke beech jo duri hoti hai uska 4 bhaag
या आप से वीडियो कॉल बात करे का कोई समय
Sir apne ek video me ld ka formula "ld=45d" bataya tha par ye video me 50 liya hai, aisa kyo?? 🤔🤔
Ld length is depend upon the Grade of Steel and Grade of concrete ✌️🔥😎😎
@@imamshaikh5198 ld is minimum 75 provide..
s
Sir slab m 20 ka sarita lagta h kya
Slab thickness divided by 8 is the formula. For residential buildings upto 12 mm rod is used.
25 ka bhi lagta he
सर क्या आप का फोन नम्बर मिल सकता है
Y u v.n