How to adjust the water pressure after replacing the autoclave expansion vessel

แชร์
ฝัง
  • เผยแพร่เมื่อ 9 พ.ย. 2020
  • Expansion vessels on amzn.to/35dF1m4
    After a week of dishwasher, washing machine, boiler, and other appliances afflicted by various malfunctions and above all 5 degree showers, I decided to remedy this tedious situation also because I became a popularizer of the miraculous properties of cold showers, which can make you a better and winning person, it seems to me disrespectful towards those who to solve problems, perhaps even of an existential type, prefer to use a drill, saw, screwdriver, hammer, perhaps computer and rattle off the rosary appealing to all the saints of the calendar passing also to the blessed if the first courses were not enough.
    So I slipped into the first brico that I crossed on my way, I took the expansion tank for the autoclave that to the eye seemed more similar to the one that, certainly no longer working perfectly, is the cause of all these other aforementioned malfunctions, regardless too much to the technical specifications, on the other hand to go back to replace it or with the exact technical specifications, it would not have made a difference.
    The pressure that a regular household appliance operator guarantees is between about 2 and 4 bars and in buildings with autoclave tanks the pressure regulator is the expansion tank.
    An autoclave system is essentially composed of a cistern where the water from the aqueduct flows, a pump that takes the water from the cistern, an expansion tank where the water taken from the pump is pressurized, a pressure switch that controls the pump according to at the minimum and maximum pressure reached by the water and two non-return valves, one located before and one after the pump which serve respectively to prevent the water from returning to the tank and to withdraw the water from the autocave when aqueduct is insufficient or nil in the absence of water.
    In this way the autoclave system has the dual task of maintaining the ideal water flow rate and water reserve proportional to the size of the tank.
    All the components of the autoclave system are related to each other in terms of size and power and on the whole they must satisfy the users to be served.
    To choose the size and the type of expansion vessel, it is mainly necessary to refer to the power and capacity of the pump.
    To replace an expansion tank, just unscrew the old one counterclockwise and screw the new one clockwise again, taking care before proceeding to drain all the system water after disconnecting the pump from the current, covering with plastic electrical components potentially exposed to any splashes of water, having closed all the general taps of both the aqueduct and the cistern, having garnished the thread with a little hemp to avoid leaks and having checked the vacuum pressure of the expansion which must be the same as that reported on the technical specifications.
    If the new expansion tank is identical to the old one, it will probably be sufficient to reopen all the general cocks, reconnect the pump to the electrical network and test that everything is working correctly, otherwise the pressure switch intervention interval will have to be re-calibrated.
    Usually the pressure switch looks like a plastic box attached to the pump, once the cover is removed, two screws are accessed which are used to adjust the pump connection and disconnection pressure, turning the screw on the left clockwise increases both the pressure minimum than maximum and vice versa while turning the screw clockwise to the right raises only the maximum pressure and vice versa, but for safety it is better to check the specifications of your pressure switch.
    In my case I calibrated the pressure switch to turn on the pump just before 2 bar and turn it off at about 2.5 bar, so that with a fully open tap the pump works for about 10 seconds and remains disconnected for about 20 seconds, if the pump never switches off, the intervention threshold must be lowered.
    During the assembly operations it is necessary to pay attention to incrustations which, detaching themselves, can create problems with the non-return valves or clog the nozzles on the taps.
    If the malfunction of the expansion tank depends on the breaking of the lung, i.e. the internal rubber bag, it is possible for some models to find a compatible spare part and replace it only, saving a few tens of euros and above all polluting much less ...
    Andrea's Toolbox
  • แนวปฏิบัติและการใช้ชีวิต

ความคิดเห็น • 42

  • @antoninosegesta6449
    @antoninosegesta6449 2 ปีที่แล้ว +1

    Ok grazie messier dell'informazione tankyiu buona vita

    • @AndreaBox
      @AndreaBox  2 ปีที่แล้ว

      Prego, Ciao.

  • @fabrizioricci4857
    @fabrizioricci4857 3 ปีที่แล้ว +1

    Bel video. quando hai smontato il vecchio vaso di espansione, era pieno d'acqua oppure era vuoto ?

    • @AndreaBox
      @AndreaBox  3 ปีที่แล้ว +1

      Come si vede dal video ho chiuso gli ingressi e fatto defluire tutta l'acqua da un rubinetto con la pompa spenta . La pressione del manometro arriva a zero quando quasi tutta l'acqua è defluita, ma in ogni caso meglio preparare un bel secchio. Grazie per la visione, se non lo hai già fatto: condividi, commenta, metti mi piace, iscriviti al canale.
      Gruppo telegram su t.me/andreastoolbox

  • @michelebelcuore6839
    @michelebelcuore6839 ปีที่แล้ว +1

    Ciao complimenti !posso chiederti se ho capito bene devo mettere una valvola di non ritorno prima e dopo l autoclave giusto?in piú dopo averlo montato devo riempirlo io l autoclave dalla vite giusto il vaso a espansione si caricherà lui giusto in base alla pressione prestabilita dall' prestostato .bravo e simpatico come spieghi

    • @AndreaBox
      @AndreaBox  ปีที่แล้ว

      Si la valvola di non ritorno deve essere prima e dopo, il vaso di espansione deve essere precariato alla pressione indicata nelle specifiche tecniche e montato vuoto , verrà riempito dalla pompa pilotata dal pressostato. Grazie per la visione, se non lo hai già fatto: condividi, commenta, metti mi piace, dai una occhiata agli altri video, offri un super grazie ed iscriviti al canale. Grazie per il supporto. Ciao
      Gruppo telegram su t.me/andreastoolbox

  • @antoninosegesta6449
    @antoninosegesta6449 3 ปีที่แล้ว +1

    Buona sera scusa volevo un informazione da lei quando io smonto il vaso naturalmente vuoto poi lo debbo gonfiare la Camera d'aria si o no quando la monto ok

    • @AndreaBox
      @AndreaBox  2 ปีที่แล้ว

      Ė meglio gonfiarlo a vuoto alla pressione indicata sulle specifiche. Grazie per la visione, se non lo hai già fatto: condividi, commenta, metti mi piace, iscriviti al canale.
      Gruppo telegram su t.me/andreastoolbox

  • @enzomaia715
    @enzomaia715 2 ปีที่แล้ว

    Buonasera Andrea, perché con l’impianto di irrigazione chiuso mi per te la pompa per 5 secondi. Devo tarare di nuovo i bar oppure devo cambiare il pressostato. Tieni presente che ha più di 20 anni. Grazie Enzo

    • @AndreaBox
      @AndreaBox  ปีที่แล้ว

      Probabilmente c'è qualche perdita, anche piccola, nell'impianto oppure le valvole di non ritorno non chiudono bene, magari fai qualche prova con il rubinetto generale dopo in contatore chiuso ed altri.
      Grazie per la visione, se non lo hai già fatto: condividi, commenta, metti mi piace, dai una occhiata agli altri video ed iscriviti al canale.
      Gruppo telegram su t.me/andreastoolbox

  • @christianseminara8756
    @christianseminara8756 2 ปีที่แล้ว +1

    Salve la pressione di precarica del vaso d'espansione di 25 litri deve essere inferiore al punto di intervento del pressostato o uguale?

    • @AndreaBox
      @AndreaBox  2 ปีที่แล้ว

      La pressione di prevarica a vuoto deve essere quella indicata nelle specifiche del produttore. Grazie per la visione, se non lo hai già fatto: condividi, commenta, metti mi piace, iscriviti al canale.
      Gruppo telegram su t.me/andreastoolbox

  • @RusseLLab.
    @RusseLLab. ปีที่แล้ว

    Ciao, basta avvitarlo a mano il vaso di espansione ? Canapa o teflon come un qualsiasi raccordo e stretto a mano. Grazie

    • @AndreaBox
      @AndreaBox  11 หลายเดือนก่อน +1

      Si, il raggio del vaso da da leva. Grazie per la visione, se non lo hai già fatto: condividi, commenta, metti mi piace, dai una occhiata agli altri video, offri un super grazie e per non perdere i prossimi video iscriviti al canale. Grazie per il supporto. Ciao
      Gruppo telegram su t.me/andreastoolbox

  • @michelerossi9399
    @michelerossi9399 ปีที่แล้ว

    salve, ho una pompa dal che aspira da una falda, funziona correttamente, se lascio 1 metro di canna come scarico pressione resta a 2 bar diciamo, se metto una canna lunga 20 metri va a 5 circa, e normale?

    • @AndreaBox
      @AndreaBox  ปีที่แล้ว

      In generale senza scendere nei dettagli delle leggi fisiche, negli impianti bisogna tenere in conto delle perdite di carico dovute all'attrito del liquido che scorre nelle tubazioni che aumenta all'aumentare della lunghezza delle tubazioni; quindi per compensarle la pompa aumenta la pressione di immissione iniziale. Grazie per la visione, se non lo hai già fatto: condividi, commenta, metti mi piace, dai una occhiata agli altri video, offri un super grazie ed iscriviti al canale. Grazie per il supporto. Ciao
      Gruppo telegram su t.me/andreastoolbox

  • @neculaiariton5302
    @neculaiariton5302 3 ปีที่แล้ว +2

    Salve,di recente mi hanno sostituito motorino del autoclave da ora la autoclave quando in uso continua andare quasi continuo circa 2 secondi si 2 no con variazione di pressione del acqua,altre fastidioso rumore...mi rivolgo a chi è bravo in queste cose... quale può essere problema e come rimediare.grazie

    • @AndreaBox
      @AndreaBox  3 ปีที่แล้ว

      Credo sia da regolare il pressostato oppure è sottodimensionato, se non ci sono rotture.
      Grazie per la visione, se non lo hai già fatto: condividi, commenta, metti mi piace, iscriviti al canale.
      Gruppo telegram su t.me/andreastoolbox

  • @vinceaudi281
    @vinceaudi281 11 หลายเดือนก่อน

    Salve, hanno montato una pompa di calore per una villetta elettropompa autoadescante con pressostato integrato, 0,75 w hp1 matra. quando si aprono i rubinetti in casa la pompa va e si accende, invece è come se non arrivasse pressione alla pompa di calore (vano tecnico dove sono collegati anche 3 rubinetti e 1 wc) e quindi non possiamo collaudare il tutto. quale potrebbe essere il problema? grazie

    • @AndreaBox
      @AndreaBox  9 หลายเดือนก่อน

      Controlla che non vi siano valvole chiuse, che la pressione sia sufficiente per la pompa di calore e che la pompa sia dimensionata adeguatamente. Grazie per la visione, se non lo hai già fatto: condividi, commenta, metti mi piace, dai una occhiata agli altri video, offri un super grazie ed iscriviti al canale. Grazie per il supporto. Ciao
      Gruppo telegram su t.me/andreastoolbox

  • @sossioderrico4184
    @sossioderrico4184 3 ปีที่แล้ว +1

    Perché ci sono vasi di espansione di diverse dimensioni e quali le differenze operative

    • @AndreaBox
      @AndreaBox  3 ปีที่แล้ว +1

      Il vaso di espansione deve essere dimensionato alla potenza della pompa ed all'utenza da servire, esistono anche formule per calcolare la dimensione giusta. Inoltre c'è ne sono sia per uso alimentare che non alimentare. Grazie per la visione, se non lo hai già fatto: condividi, commenta, metti mi piace, iscriviti al canale.
      Gruppo telegram su t.me/andreastoolbox

  • @christianseminara8756
    @christianseminara8756 2 ปีที่แล้ว +1

    Il pressostato pressione minima e massima a quanto va regolato in una villa pianoterra? Pressostato square d fsg22

    • @AndreaBox
      @AndreaBox  2 ปีที่แล้ว +1

      Gli elettrodomestici sono progettati per pressioni da 2 a 4 bar. Nel mio caso, magazzino piano terra, ho tarato il pressostato per fare accendere la pompa poco prima dei 2 bar e farla spegnere a circa 2,5 bar, in modo tale che con un rubinetto tutto aperto la pompa lavori per circa 10 secondi e rimanga staccata circa 20 secondi, se la pompa non stacca mai bisogna abbassare la soglia di intervento. Grazie per la visione, se non lo hai già fatto: condividi, commenta, metti mi piace, iscriviti al canale.
      Gruppo telegram su t.me/andreastoolbox

    • @monicalovato1889
      @monicalovato1889 3 หลายเดือนก่อน

      La vite piccola non regola la pressione. Di partenza autoclave. ​@@AndreaBox

  • @giagia7766
    @giagia7766 8 หลายเดือนก่อน

    Ciao, ho montato qualche ora fa il vaso di espansione con autoclave. Vorrei capire se è normale che mentre il rubinetto è aperto il pressostato attacca e stacca o va regolato il pressostato.

    • @AndreaBox
      @AndreaBox  8 หลายเดือนก่อน

      Si deve accendere il meno possibile per preservare il motore, per un impianto piccolo a rubinetto aperto impiegherà più tempo per spegnersi e si riaccenderà a seconda della portata del rubinetto dopo 10/30 secondi , ma in generale bisogna fare riferimento alle specifiche dichiarate dal costruttore per tarare il tutto. Grazie per la visione, se non lo hai già fatto: condividi, commenta, metti mi piace, dai una occhiata agli altri video, offri un super grazie ed iscriviti al canale. Grazie per il supporto. Ciao
      Gruppo telegram su t.me/andreastoolbox

  • @stefanosa100
    @stefanosa100 4 หลายเดือนก่อน

    Speriamo che ci sia sul mercato un'inversione di tendenza e se possibile sostituire solo la camera d'aria. Mi sembra uno spreco inutile buttare anche la parte metallica.

    • @AndreaBox
      @AndreaBox  4 หลายเดือนก่อน

      In alcune ferramenta si trovano ancora le membrane ma devono essere compatibili.
      Grazie per la visione, se non lo hai già fatto: condividi, commenta, metti mi piace, dai una occhiata agli altri video, offri un super grazie e per non perdere i prossimi video iscriviti al canale. Grazie per il supporto. Ciao
      Canale WhatsApp su whatsapp.com/channel/0029VaLJSbc9cDDYrfYAgV2L
      Gruppo telegram su t.me/andreastoolbox

  • @vincentecharlieraccosta5819
    @vincentecharlieraccosta5819 15 วันที่ผ่านมา

    La mia autoclave, aveva bisogno di cambiare la tenuta e un cuscinetto perché perdeva e mi faceva staccare il salvavita. Smontata la pompa e cambiato tutto perfettamente. Rimonto il tutto. Ma aimé l'autoclave stavolta non stacca. Da permettere che non ho toccato il pressostato ho solo smontato momentaneamente il vaso d'espansione e rimontato il tutto dopo la manutenzione alla pompa. Perché l'autoclave stavolta non stacca? È un problema di pressostato? O di vaso d'espansione?

    • @AndreaBox
      @AndreaBox  14 วันที่ผ่านมา +1

      Potrebbe essere un problema del pressostato o del vaso d’espansione. Se il pressostato non rileva la pressione corretta o se il vaso d’espansione non funziona come dovrebbe, l’autoclave potrebbe non spegnersi. Altre possibili cause potrebbero essere impurità nel sistema che interferiscono con il funzionamento del pressostato o della pompa, problemi elettrici o guasti nel cablaggio, componenti usurati o danneggiati che necessitano di sostituzione, o una regolazione impropria del pressostato. Se non sei sicuro di come procedere, è sempre una buona idea consultare un professionista.
      Grazie per la visione, se non lo hai già fatto: condividi, commenta, metti mi piace, dai una occhiata agli altri video, offri un super grazie ed iscriviti al canale. Grazie per il supporto. Ciao
      Gruppo telegram su t.me/andreastoolbox

    • @vincentecharlieraccosta5819
      @vincentecharlieraccosta5819 13 วันที่ผ่านมา +1

      @@AndreaBox . Grazie per la tua risposta. Ho risolto stamani,ho capito quale era il problema. Quando ho montato la pompa non mi ero accorto che ho montato il cablaggio (l'avvolgimento motore)al contrario avevo invertito il senso di marcia. Hahahaha. Era la mia prima volta. Comunque l'ho smontata e rimontata nel verso giusto. Adesso funziona alla grande e anche più silenziosa.😁

    • @AndreaBox
      @AndreaBox  13 วันที่ผ่านมา +1

      @@vincentecharlieraccosta5819 Perfetto e grazie per aver condiviso la tua esperienza.

  • @desdedesde790
    @desdedesde790 2 ปีที่แล้ว

    Il mio con quattro mani non si svita...forse non tutti i vasi si smontano così...

    • @AndreaBox
      @AndreaBox  2 ปีที่แล้ว

      Quelli che ho visto io sono tutti così, se non ci sono dadi bulloni, giunti o saldature prova a mettere dello Svitol o WD40 e lascia agire per qualche ora, ripetendo l'operazione se necessario. Grazie per la visione, se non lo hai già fatto: condividi, commenta, metti mi piace, iscriviti al canale.
      Gruppo telegram su t.me/andreastoolbox

  • @Franco-ec5cw
    @Franco-ec5cw ปีที่แล้ว

    Troppo veloce nelle spiegazioni.

    • @AndreaBox
      @AndreaBox  ปีที่แล้ว

      Prova a leggere descrizione e sottotitoli oppure ad utilizzare la riproduzione a velocità ridotta che trovi nelle impostazioni di TH-cam nel video, l'ingranaggio in alto a destra. Grazie per il suggerimento e la visione, se non lo hai già fatto: condividi, commenta, metti mi piace, dai una occhiata agli altri video, offri un super grazie ed iscriviti al canale. Grazie per il supporto. Ciao
      Gruppo telegram su t.me/andreastoolbox

  • @sergiocuezzu5386
    @sergiocuezzu5386 3 ปีที่แล้ว +1

    Snocciolare il rosario 📿 io lo snocciolo tutte le volte che mi provo a fare la doccia.

    • @AndreaBox
      @AndreaBox  3 ปีที่แล้ว

      Spero sia impermeabile 😀

    • @sergiocuezzu5386
      @sergiocuezzu5386 3 ปีที่แล้ว +1

      @@AndreaBox la pressione dell'acqua è inregolare,o troppo forte o troppo poca con notevoli cambi di temperatura o troppo calda o troppo fredda

    • @AndreaBox
      @AndreaBox  3 ปีที่แล้ว

      Per non avere problemi con gli elettrodomestici , caldaia, lavatrice, lavastoviglie, ecc... deve essere compresa tra un minimo di 1.5 e un massimo di 3 bar ed il più possibile costante.

    • @giuseppetubolino3865
      @giuseppetubolino3865 3 ปีที่แล้ว

      Ma ti sembra questo il modo di spiegare (intendo la velocità di parlare) per far comprendere a chi ascolta e guarda? Sarai un ottimo idraulico ma l'insegnamento, mi spiace, non fa per te. Un saluto