Stop push connection should be in series with overload contact whereas here the sto push elemnt has been connected across parallel to thermal overload contact
Sahab ji ye jo apnay nc push button lagaya aur relay ka NC wo galat connection hai is say off nahi hoga kiyan ki ye dono parlal main attay hain ye series mai karo
Bhai sab, bohut acha explainkia hai , lekin ek ghalti kia lagta hai. Apne off botton switch parralel connect kia hai over load kho. Vho series me hona chahié. Hai ki nahi. Please reply kro.
Capacitors connection is little wrong I guess, running and starting capacitors combined wire has to connect to yellow wire i.e Starting winding. Please explain
Sir last ki Jo nc push button connection Kiya Aisa karne se only Olr ki nc se hi off hoo Sakta he...Lekin wo connection Olr ki no ....nc ki looping ke andar lagana padega...too hamari two way on off hoga.....
Sir please 3 phase submersible pump ka control bnaye jab water level submersible ki range se nichey ho jye to pump automatic off ho jye r jb water level increase ho pump automatically start ho jye, yh manually start kiyaa jye. Mutlab pannel pey 2no option mojood hon
Sir sab kuch thik hai Lekin ap jo NC switch ka connection kiya yeh kavi off nehi hoga starter. agar off hoga to contactor switch se hi starter off hoga.
Bhai aap air conditioner mey jo contactor use kar tey hai wo contactor use kar key diagram dekha ye q k us me NO NC nai ho ta..es se zaldi samaj aata hai
Good information sir
Very nice video sir ji fantastic
Very nice video thanks sir
Bahut bahut dhanyvad sar
Superb sir
Ab sir isme Auto switch ki wiring connection wala video banaye
Sir
Stop push connection should be in series with overload contact whereas here the sto push elemnt has been connected across parallel to thermal overload contact
U r right
Right brother
Video 1 Number he bhai iske Thank you kahna Nhi bhulunga...
Thanks
Very nice.... Your teaching is awesome....
Best video Bhai
Good work sr
Nice video Sir
GOOD. CLARITY.
Nice 🌹👏😷
Good
Thanks guruji
very good video..thanks for your time
Nice
Bahut badia sir
Thank you sir ji,keep making videos,sir your NC push button connection is wrong .
Thanks sar hi❤️🙏
👍👍🙏💯Very good
Best.
Very good brother
Very very good
Bhut badhai
सीखखखने वाले हैं।,😊😊😊😊😊😊
Main Contactor nc and stop nc parallel me diya tu off kaise hoga??
Buhut sahi sanjhaya hai
Excellent explanation. Thanks. If possible, kindly explain how auto controller wires are connected in this schematic.
बहुत ही सरल तरीका सिखाया हे आप ने भाई साहब
Shukriya sir ji ❤️❤️
Very nice 👌
🙄
Good one. My supports
Indicater wireing connection.🙏🙏
Nice exalnation
Stop push button apne parllal me lgaya hai jo roung hai stop push button series me lgaya jata hai
thankyou sir for information......
👍
informative video✔
3 phase starter settings
Super
Sir aphne last me bataya off button ka galath laghrahai already contector me NC hotahi aph NC push button se kaise off hogi??
Yes.. That is a rong explanation
Sahab ji ye jo apnay nc push button lagaya aur relay ka NC wo galat connection hai is say off nahi hoga kiyan ki ye dono parlal main attay hain ye series mai karo
Remot Stop push button galat connect hai
Remot stop push button galat connect hai
Wiring is fake
Thanks sir
Sir esme No push button k done N N terminals mein lopping nahi ki jati hai ?
Sirji 3phase motar srater pannel wiring video upload kijiye.
👌👌👌
Thanks Sir 🙏🏻🙏🏻
नमस्कार सर अम्पीयर मिटर खराब हुआ तो मोटर चालू नही होती है क्या
अम्पीयर मिटर निकाल कर उसका वापर डायरेक्ट कर सकते है क्या बताईये.
Yes kr dijiye
Your NC point contractor and OOF Push button is wrong because not a parallel only series thanks 🙏
By mistake please consider
Bhai sab, bohut acha explainkia hai , lekin ek ghalti kia lagta hai. Apne off botton switch parralel connect kia hai over load kho. Vho series me hona chahié. Hai ki nahi. Please reply kro.
Ok sir by default hua h please consider
Perfect explanation sir Thank-you...Iss circuit mein Remote wiring QHAISE Add karna hai...
Motor stop nahi hoga stop botton ka nc and starter ka nc series me hoga
Esme alg se jo off switch laga hai es circuit se kam nahi karega. Esko main current se connect karna parega
Capacitors connection is little wrong I guess, running and starting capacitors combined wire has to connect to yellow wire i.e Starting winding. Please explain
Earth really connection please 🙏
Namaskar batching plant ke electrical wiring ka bhi thoda video banaa date to bahut achha hota
2 pesh ka connection kaa video banaye
2 pole k contactor ka starter conection bataiye
Sir last ki Jo nc push button connection Kiya Aisa karne se only Olr ki nc se hi off hoo Sakta he...Lekin wo connection Olr ki no ....nc ki looping ke andar lagana padega...too hamari two way on off hoga.....
Kisi se bhi off nahi hoga mera manhai bhai
1 capacitor motor ka or 1 kisliye dusra torika se banayega to kuch problem hoga bhaiya ampire meter series jaisa lagaya hain na
4
Sir 2 pole wale contctot ka starter conection bataiye
Starting capacitor ki wire y line pr lgni hai sir bcz starting winding code is y
Xtra NC push batan ke connection galat hai off'nahi hoga
Sir please 3 phase submersible pump ka control bnaye jab water level submersible ki range se nichey ho jye to pump automatic off ho jye r jb water level increase ho pump automatically start ho jye, yh manually start kiyaa jye. Mutlab pannel pey 2no option mojood hon
WLC water level controler
Use
Sir sab kuch thik hai Lekin ap jo NC switch ka connection kiya yeh kavi off nehi hoga starter. agar off hoga to contactor switch se hi starter off hoga.
Sir push button se ban nahi hoga Kyu ki startar ka nc Kat nahi hoga na perelal me Diya huva hai na esliye
Sir he stater kithana hp Singal phase
Motor run kane keliye use kar saktha hi
Red Button se Of Nahi Hoga. kya sikhe sir ulta confuse Honge Naye student
Starting capacitor off kiun Nehi ho payega uske bareme thoda bataiye
Starter ko direct line mein jodke mcb se off on karna thik hoga kya?
😂😂😂
Sar Singal phase 3hp oil immersed contral panel starter par ek camplit video or bana do
Kis type ka wire use krna chahiye panel bnane me ?
Nc push button is wrong connection
By mistake sir
Please consider
DOL STARTER auto manual
Boss ye wala starter ka do jagah se on off kaise karenge aur kitna taar le jana padega
Only 2 wire
Sir bahut achha sujhav diya aur achhe se aur vidip dale
👌👍🙏🤝🌹🌹
Stater off nahi hoga.
Bhai aap air conditioner mey jo contactor use kar tey hai wo contactor use kar key diagram dekha ye q k us me NO NC nai ho ta..es se zaldi samaj aata hai
Sir Rong connection forthis video how are you off switch push button work condition? Please explain sir
Thank u sir..
Starting capcitar start push button se jayega to NC k thru ya no k
dono element no h ya NO . NC h
500v coil chal sakati hai for 2hp single phase motor
Start condition me volt meter chalu nahi rahega kya
B auri y Badal jaaye to kya hoga
indicater
I want to 3phase submersible pump control wiring
Red button ki to wearing Ki Nahin sir aapane
Sir ji which software is used for drawing
Sar ismein single phase auto switch kaise Tarah lagayenge
sar aap se aek galti hui hai aap ne stop pus batan ko pairral me joda hai jo ki sirij me rahe ga
Sir ye green wala switch garam hoke pigal kyu jata hai kabi kabi
Sir Esme on off trip indicater ka wireing kaese kare.please sir ji 🙏🙏🙏
Ha bhai video ke last me NC connection galat h wo to NO hoga he nahi
Ok by mistake please consider
कंटेक्टर ३ फ़ेज का है और वायरिंग सिंगले फ़ेज़ की कर रहे ....!!!!!
Three pole ke contactor ko to bta diya aapne two pole contactor ka vdo bnaiye
Stop pus baten vairing gelet he moter stop nhe hogi
On karne par off nehi ho raha he
Push to off button 96/95 Kodiya to overload protection Kaise milega
Automatic ty then you motar overload
Put your videos in English
Ok