SUBMERSIBLE STARTER COMPLETE WIRING! RUNNING CAPACITOR CONNECTION! STARTING CAPACITOR CONNECTION
ฝัง
- เผยแพร่เมื่อ 5 ก.พ. 2025
- submersible starter connection with starting & running capacitor
in this video we explain submersible starter connection with voltmeter, ammeter, start stop switch and capacitor
we explain submersible starter power & control wiring very easily for learning submersible starter connection just watch and learn
#submersible starter connection#
What is VOLTAGE drop
• What Is Voltage Drop i...
Neutral & earth difference
• NEUTRAL और EARTH में क...
Why transformer neutral graund or earth
• WHY TRANSFORMER NEUTRA...
Siemens drive parameter setting and connection
• SIEMENS SINAMICS V20 D...
How to calculate kwh or electrical bill calculation
• WHAT IS KWH(UNIT)? HOW...
Cable testing with multimeter
• HOW TO TEST CABLE WITH...
Reverse forward starter power wiring connection
• REVERSE FORWARD STARTE...
Manual reverse forward starter with limit switch
• How to make Reverse fo...
Automatic reverse forward starter
• Star Delta starter pow...
Automatic reverse forward motor starter connection
• Automatic reverse forw...
3 phase rccb test on single phase supply practical
• 3 PHASE RCCB मे SINGLE...
3 phase ammeter connection with selector switch
• 3 PHASE AMMETER CONNEC...
8 pin relay testing with multimeter
• 8 PIN RELAY TESTING WI...
How to check ceiling fan common start run with multimeter
• 3 WIRE CEILING FAN COM...
How to make dol starter with relay
• How to make dol starte...
How to check ceiling fan common start run with series lamp
• Video
ammeter connection with current transformer
• 3 PHASE AMMETER CONNEC...
Cooler motor testing with series test lamp
• COOLER MOTOR TESTING W...
Street light timer setting
• STREET LIGHT TIMER SET...
Air compressure power & control wiring practically
• AIR COMPRESSURE के ST...
3 phase cable testing with megger
• HOW TO CHECK CABLE INS...
3 phase motor test with megger
• Induction motor test (...
Dol starter control from different points
• MOTOR CONTROL FROM DIF...
How to make reverse forward motor starter
• How to make Reverse f...
Manual reverse forward starter with limit switch
• How to make Reverse fo...
Automatic reverse forward starter
• Star Delta starter pow...
Automatic reverse forward motor starter connection
• Automatic reverse forw...
Thanks for watching
Very nice diagram 👍👍👍
Very nice video sir ji fantastic
Very nice video thanks sir
Video 1 Number he bhai iske Thank you kahna Nhi bhulunga...
Thanks
Good information sir
Nice 🌹👏😷
Good work sr
👍👍🙏💯Very good
Nice video Sir
Bahut bahut dhanyvad sar
Very nice.... Your teaching is awesome....
very good video..thanks for your time
Best video Bhai
Thanks guruji
Bahut badia sir
GOOD. CLARITY.
Buhut sahi sanjhaya hai
Shukriya sir ji ❤️❤️
Nice
Thank you sir ji,keep making videos,sir your NC push button connection is wrong .
Very very good
Very nice 👌
🙄
Good
Best.
Stop push connection should be in series with overload contact whereas here the sto push elemnt has been connected across parallel to thermal overload contact
U r right
Right brother
Superb sir
Ab sir isme Auto switch ki wiring connection wala video banaye
Sir
Very good brother
Thanks sar hi❤️🙏
Nice exalnation
Good one. My supports
Sir,ON indication supply ap ON push bottom se diye hai to fir ON indication utna der ON hoga jitne der ON push botton ko press kar ke rakhege
सीखखखने वाले हैं।,😊😊😊😊😊😊
thankyou sir for information......
Bhut badhai
informative video✔
Super
Thanks sir
Thanks Sir 🙏🏻🙏🏻
Bhai sab, bohut acha explainkia hai , lekin ek ghalti kia lagta hai. Apne off botton switch parralel connect kia hai over load kho. Vho series me hona chahié. Hai ki nahi. Please reply kro.
Ok sir by default hua h please consider
👌👌👌
Excellent explanation. Thanks. If possible, kindly explain how auto controller wires are connected in this schematic.
बहुत ही सरल तरीका सिखाया हे आप ने भाई साहब
Indicater wireing connection.🙏🙏
Main Contactor nc and stop nc parallel me diya tu off kaise hoga??
नमस्कार सर अम्पीयर मिटर खराब हुआ तो मोटर चालू नही होती है क्या
अम्पीयर मिटर निकाल कर उसका वापर डायरेक्ट कर सकते है क्या बताईये.
Yes kr dijiye
Sahab ji ye jo apnay nc push button lagaya aur relay ka NC wo galat connection hai is say off nahi hoga kiyan ki ye dono parlal main attay hain ye series mai karo
Remot Stop push button galat connect hai
Remot stop push button galat connect hai
Wiring is fake
Your NC point contractor and OOF Push button is wrong because not a parallel only series thanks 🙏
By mistake please consider
Coile ko holding karne ke liye phase chahiye 4 no point se vaha s e aapne neutral provide kiya aapne
Sirji 3phase motar srater pannel wiring video upload kijiye.
Stop push button apne parllal me lgaya hai jo roung hai stop push button series me lgaya jata hai
Capacitors connection is little wrong I guess, running and starting capacitors combined wire has to connect to yellow wire i.e Starting winding. Please explain
Sir aphne last me bataya off button ka galath laghrahai already contector me NC hotahi aph NC push button se kaise off hogi??
Yes.. That is a rong explanation
Esme alg se jo off switch laga hai es circuit se kam nahi karega. Esko main current se connect karna parega
Sir last ki Jo nc push button connection Kiya Aisa karne se only Olr ki nc se hi off hoo Sakta he...Lekin wo connection Olr ki no ....nc ki looping ke andar lagana padega...too hamari two way on off hoga.....
Kisi se bhi off nahi hoga mera manhai bhai
1 capacitor motor ka or 1 kisliye dusra torika se banayega to kuch problem hoga bhaiya ampire meter series jaisa lagaya hain na
Sir esme No push button k done N N terminals mein lopping nahi ki jati hai ?
Earth really connection please 🙏
👍
Sir he stater kithana hp Singal phase
Motor run kane keliye use kar saktha hi
Bhai aap air conditioner mey jo contactor use kar tey hai wo contactor use kar key diagram dekha ye q k us me NO NC nai ho ta..es se zaldi samaj aata hai
Starting capacitor off kiun Nehi ho payega uske bareme thoda bataiye
Sir Rong connection forthis video how are you off switch push button work condition? Please explain sir
2 pole k contactor ka starter conection bataiye
Sir 2 pole wale contctot ka starter conection bataiye
Namaskar batching plant ke electrical wiring ka bhi thoda video banaa date to bahut achha hota
Sir please 3 phase submersible pump ka control bnaye jab water level submersible ki range se nichey ho jye to pump automatic off ho jye r jb water level increase ho pump automatically start ho jye, yh manually start kiyaa jye. Mutlab pannel pey 2no option mojood hon
WLC water level controler
Use
Motor stop nahi hoga stop botton ka nc and starter ka nc series me hoga
2 pesh ka connection kaa video banaye
3 phase starter settings
Starting capacitor ki wire y line pr lgni hai sir bcz starting winding code is y
👌👍🙏🤝🌹🌹
Perfect explanation sir Thank-you...Iss circuit mein Remote wiring QHAISE Add karna hai...
Boss ye wala starter ka do jagah se on off kaise karenge aur kitna taar le jana padega
Only 2 wire
Sir bahut achha sujhav diya aur achhe se aur vidip dale
Xtra NC push batan ke connection galat hai off'nahi hoga
Starting capcitar start push button se jayega to NC k thru ya no k
dono element no h ya NO . NC h
Sir ji which software is used for drawing
Starter ko direct line mein jodke mcb se off on karna thik hoga kya?
😂😂😂
how create this video which software used please know to me
Start condition me volt meter chalu nahi rahega kya
Sir push button se ban nahi hoga Kyu ki startar ka nc Kat nahi hoga na perelal me Diya huva hai na esliye
Sar Singal phase 3hp oil immersed contral panel starter par ek camplit video or bana do
500v coil chal sakati hai for 2hp single phase motor
Red Button se Of Nahi Hoga. kya sikhe sir ulta confuse Honge Naye student
sar aap se aek galti hui hai aap ne stop pus batan ko pairral me joda hai jo ki sirij me rahe ga
Thank u sir..
Sir ye green wala switch garam hoke pigal kyu jata hai kabi kabi
I want to 3phase submersible pump control wiring
Kis type ka wire use krna chahiye panel bnane me ?
Sir sab kuch thik hai Lekin ap jo NC switch ka connection kiya yeh kavi off nehi hoga starter. agar off hoga to contactor switch se hi starter off hoga.
Sir Esme on off trip indicater ka wireing kaese kare.please sir ji 🙏🙏🙏
Sar ismein single phase auto switch kaise Tarah lagayenge
Nc push button is wrong connection
By mistake sir
Please consider
submersible starter सर कितने tipy के बाजार मेेे आते है और आन्तर क्या क्या होते है
Red button ki to wearing Ki Nahin sir aapane
Sir hamre motor on Karne par hand pump me current aata hai
Aapki dusri video me aapne NO switch ko contarctor ke NO par lagaya hai, jabki iss video me apne NO switch ko contractor ke NC par ek terminal aur dusra relay pr joda hai. kon sa correct h??
Push to off button 96/95 Kodiya to overload protection Kaise milega
Automatic ty then you motar overload
Ha bhai video ke last me NC connection galat h wo to NO hoga he nahi
Ok by mistake please consider
B auri y Badal jaaye to kya hoga
Stop pus baten vairing gelet he moter stop nhe hogi
How to bypass start sw for imagine tl80 wlc