- Reinforcement lapping Zone as per IS Code 13920 in Column
• Reinforcement lapping ...
What is Development Length in Beam Column Footing and Pile Cap
• What is Ld | What is ...
Development Length Value for Different Grade of Concrete for Practical Use at Construction Site
• Development Length Val...
How to Derive Development Length of Bar Formula as Per IS 456 2000
• How to Derive Developm...
How to Calculate Development Length of Bar as Per IS 456 2000
• How to Calculate Devel...
What is Ld | What is Development Length in Beam-Column Footing and Pile Cap | BBS
• What is Ld | What is ...
What is Lap Length | Overlapping | Lap Splices in Beam | Column | Footing and Pile Cap
• What is Lap Length | O...
Difference Between Development Length and Lap Length
• Difference Between Dev...
Cutting Length of Lap Length and Development Length
• Cutting Length of Lap ...
What To do if Lap in Column Comes in Zone A
• What To do if Lap in ...
Which Bar should be Staggered during lapping in Column? | Upper or Lower
• Which Bar should be JO...
How to Calculate Rolling Margin of Reinforcement Steel at Site for Billing
• How to Calculate Rolli...
Circular Cover Block in Column | Round Cover Block क्या हैं? | Importance of Round Cover Block
• Circular Cover Block i...
Download Latest IS 13920 : 2016 pdf
learningtechno...
12 Big Mistakes in RCC Beam Construction | 10 ग़लती बीम बांधते समय होता है | Learning Civil Technology
#learningciviltechnology #civilengineeringvideos #RCCBeamMistake #BigMistakeInBeam
*****************************************
JOIN US ON
✔Telegram: t.me/LearningC...
✔Instagram: / learningciviltechnology
✔Facebook: / learningtechnologyoffi...
*****************************************
⓿My Playlist Link
✔HOW TO STUDY DRAWING
• How To Study Drawing
✔CIVIL INTERVIEW
• Interview
✔CHECKLIST OF CIVIL WORKS
• Checklist of Civil Works
✔BBS (BAR BENDING SCHEDULE)
• BBS (Bar Bending Sched...
✔QUANTITY ESTIMATE
• Quantity Estimate
✔CONCRETE VOLUME CALCULATION
• Concrete Volume
✔IS CODE LECTURE
• IS CODE LECTURE
✔DREAM HOUSE CONSTRUCTION SERIES
• DREAM HOUSE CONSTRUCTI...
✔HOUSE CONSTRUCTION
• House Construction
✔HOUSE PLAN
• House Plan
✔CIVIL EXPERIMENTS
• Experiment
✔SURVEYING
• Surveying
✔CIVIL ENGINEERING TALK
• Civil Engineering Talk
****************************************************************
CONTACT DETAILS
✔Email Id for Business Enquiry - civilengineeringofficial@gmail.com
✔Linkedin: / civilengineermukeshsah
Disclaimer:-
Copyright Disclaimer under section 107 of the Copyright Act of 1976, allowance is made for “fair use” for purposes such as criticism, comment, news reporting, teaching, scholarship, education and research. Fair use is a use permitted by copyright statute that might otherwise be infringing.
Your all lectures are so helpful to each and every civil engineer....🙏
Hook length should be 10D as per IS code
8D also can take
Pahle tha 10d but latest 6d bol raha sir ne IS cod ka anusar
You are doing Gods work by educating new house builders 🙏 Thank you Sir
6d
V v nice Way of teaching
And the knowledge also👍
The way of yor explanation is love it sir.❤
Thanks sir for this knowledge sharing session 🙏
Very very nice and useful information sir ji 🙏😊👌👌
Very very informative video
Your lectures are like refresher course.
Some place double binding wires are used.Your comment please .
Good.teacher.and.teaching.good
Sir ji, bhut achi video banayi hai apne, samjhane ka tarika apka bhut hi acha lagta hai sir Mujhe, me apki mostly video dekhta hu or share or comment bhi or like bhi krta hu sir ji, or sir ji ab to me pure confidence se interview deta hu, sir ji me abhi CBRI roorkee me job kr rha hu, thank you🙏🙏🙏🙏 sir ji
Sir last wala samjha nehi mai ek mistri hoon, aur mai apki video kafi dino se dekh raha hoon, please sir last wala acche se samjha sakte ho
Very good mistri sahab
So super
Very detailed teaching
Very good 🌹 From Pakistan
Very Imp Topic
Position of hook should be in compression zone.
Like in continuous beam, tension zone is around upper part of beam-column junction.
Good Sir, Bangladesh
Very informative video.
Love from Pakistan ❤
Sir Plz look up where the bottom lapping zone...u said that the lapping zone in bet L/6... I thought the lapping near column we can't provide..it may be after L/6..once check
Yes agreed with you...I learn from some videos it says that lapping of bottom bar near the support is not allowed....length of effective depth multiple by 2 should be measured from column and just after that length we can provide lapping of bottom bar in beam......
(Depth of beam-bottom cover-half dia of main bar=effective depth × 2).
I'm not an engineer but I learn everyday from multiple videos of engineer....the reason I learn and watch several videos of house construction it is because I want to build my own house with my own hand and idea only..so learning and taking ideas from many people is good..😊😊
Lovk ringgit details excellent point.
Also on some extra stirrups are provided. Your comment please.
About your question: as per 13920: 2016, the minimum hook length in the RCC beam and column. Answer is c) 6d
I love you ❤❤❤❤❤
From Kolkata
Thank you 🙏
Nice one and useful
Good...Mukesh sir
stirupps in beam connecting columns should be plcaed closer near the columns and spacing should increase in the middle ?
Sir, slab checking baare mein bhi video batao plz
Best information
Sir,ek aur point hai column junction se pehla beam ka stirrups maximum 50mm ke andar aana chahiye..
Plz explain about RCC slab reinforcement
Sir, master ring as per IS code ? Clause no ?bataye?site master ring beam pe koi deta nehi.kya is ko bill me claim hota hei kya?
सर❤❤❤❤❤❤
Gjb boss mja aa gya
A/c to new abundment IS 13920:2016 ,6d hona chahiye or 65 mm in place of 10d or 75mm
Best video
nice teaching
Super...
In beams top bars lapping length should be 50d and for bottom bars lap length should be 28d..
Sir column ki bars ko cut kaise krna hota h after 2 nd floor or 3rd floor columns and so on .I mean kitni length tak cut krke rkhna hota h
Aaj ka answer is 6d
Neutral Axis kya hota he? Or reinforce steel ko kese layer mey dalna he?
Mukesh brother could you kindly clear my query. If the column size is 9×12 inch does it include cover block space of concrete or otherwise.
BDW i'm not from civil engineering background so kindly suggest your valuable info in this regard. Thank you in anticipation.
Yes... It includes
@@LearningCivilTechnology ty
❤
Wow ❤❤
In some cases, development length is exceed to beam depth then what will be the development length
Make it in C shape...
😂 How to place the bar when two ends is the same situation
Sir mere ghar ke chad ke middle beam mein plastic nehi diye the, cement slurry gira tha waha se bohot, abhi tak koi problem nehi hua but in future koi problem ho sakta hai ???
If you feel easy
Then BN Dutta explain
6d Sir
Master ring to column may provide karte hai na over the slab
Yes... Lekin yaha beam ki baat ho Rahi hai...
6d or 65mm by is code 13920..
Sir, j bolt ki details in foundation m kasa lagata h Or j bolt ki kya kya check karte h
Hook length 6d
Typical footing drawing mai likhte ish kya matlab hai ❓❓❓❓ battye bahi
Same type
Hook length must be 6d as per latest norms.
C) 6d.
C) 6D
6d sir
Jee ready Karo video about soil test
good
Master Ring.. plz explain
Sir, Master Ring & Lock Ring are not same! Master ring is the main ring of a beam but lock ring partly called as Horizontal ring
Pl clear IS516 part4 B-2.5.1 ,
Sir where it mention in IS code spacing of cover block 0.8 m.
Bhai 18x120 feet shop ready krna hai
Piller dimension bta do plz
Down beam ki bhi
Niche basement and uper ek ground floor hai
e L/6 Lap zone konse code me hai?
Sir mix design me standard deviation ka kya role h. Please ek detail video laiye is pr.
Thanks! Sir.6d hota hai.
C) 6d
Beam and column ka jaha junction banta hai ya T banta hai vaha column me stripes nahi daal pate hai beam ke steel ki vajh se to vaha kya kare .
(C) 6D
As per Is 13920:2016 is 6d
Ans.c)6d ~65mm.
May I request you to show master ring in beam in 3D view
I need bent up bar knowledge.
6D FOR HOOK LENGTH
Hook binding 135degree
कॉलम यदि 6 मीटर से भी ज्यादा दूरी हो , मान के चलो 7,9 मीटर है तो ऐसा स्थिति में कितना का लैपिंग रहेगा।
Top bar me L/3 kru and Bottom mai L/6 kro , in Top bar apka 7900 mm kit length hai na toh centre mai 2633 pr lap hoga and Bottom at both sides L/6 krna 1316 k baad side se lap kr skte ho
Top bair zont L/3 ushae aige sir
As per seismic zones ke Hisar se Kya hai lap zone
Thank you sir .
Isme 2 imp point missing hai
1. Face Bar
2. Main bar placing at junction
6D
6 D
Ans 6d ans
Stirrups hook length has been updated in the latest amendment as 8d, pehle 6d tha aab 8d hai.
6d
Pole ka size 5 floor ke liye kitna dina he
Sir agar 3D main dakha dete toh pura clear ho jata
Can we use marble pieces as cover block?
absolutely no.
@@Nick32176 dear friend cover block are not available in Pakistan. Generally people use marble pieces. What is solution?
Staad pro kyu nahi सिखाते
10 D
6 d
Please Mack videos pile load test
6D
yeh to up bata diya 6d hoga. pahle 10d tha.
6D.
Good morning sir 6d par hona chahiye
10d
IS 13920 me to likha hai joints or middle quarter me lap nahi karna hai.pleade clear
Han ek dmm sahi kah rhe ho