12 Big Mistakes in Beam Before Concreting Work at Site | Beam Checklist | Learning Civil Technology

แชร์
ฝัง
  • เผยแพร่เมื่อ 21 ส.ค. 2024
  • Reinforcement lapping Zone as per IS Code 13920 in Column
    • Reinforcement lapping ...
    What is Development Length in Beam Column Footing and Pile Cap
    • What is Ld | What is ...
    Development Length Value for Different Grade of Concrete for Practical Use at Construction Site
    • Development Length Val...
    How to Derive Development Length of Bar Formula as Per IS 456 2000
    • How to Derive Developm...
    How to Calculate Development Length of Bar as Per IS 456 2000
    • How to Calculate Devel...
    What is Ld | What is Development Length in Beam-Column Footing and Pile Cap | BBS
    • What is Ld | What is ...
    What is Lap Length | Overlapping | Lap Splices in Beam | Column | Footing and Pile Cap
    • What is Lap Length | O...
    Difference Between Development Length and Lap Length
    • Difference Between Dev...
    Cutting Length of Lap Length and Development Length
    • Cutting Length of Lap ...
    What To do if Lap in Column Comes in Zone A
    • What To do if Lap in ...
    Which Bar should be Staggered during lapping in Column? | Upper or Lower
    • Which Bar should be JO...
    How to Calculate Rolling Margin of Reinforcement Steel at Site for Billing
    • How to Calculate Rolli...
    Circular Cover Block in Column | Round Cover Block क्या हैं? | Importance of Round Cover Block
    • Circular Cover Block i...
    Download Latest IS 13920 : 2016 pdf
    learningtechno...
    12 Big Mistakes in RCC Beam Construction | 10 ग़लती बीम बांधते समय होता है | Learning Civil Technology
    #learningciviltechnology #civilengineeringvideos #RCCBeamMistake #BigMistakeInBeam
    *****************************************
    JOIN US ON
    ✔Telegram: t.me/LearningC...
    ✔Instagram: / learningciviltechnology
    ✔Facebook: / learningtechnologyoffi...
    *****************************************
    ⓿My Playlist Link
    ✔HOW TO STUDY DRAWING
    • How To Study Drawing
    ✔CIVIL INTERVIEW
    • Interview
    ✔CHECKLIST OF CIVIL WORKS
    • Checklist of Civil Works
    ✔BBS (BAR BENDING SCHEDULE)
    • BBS (Bar Bending Sched...
    ✔QUANTITY ESTIMATE
    • Quantity Estimate
    ✔CONCRETE VOLUME CALCULATION
    • Concrete Volume
    ✔IS CODE LECTURE
    • IS CODE LECTURE
    ✔DREAM HOUSE CONSTRUCTION SERIES
    • DREAM HOUSE CONSTRUCTI...
    ✔HOUSE CONSTRUCTION
    • House Construction
    ✔HOUSE PLAN
    • House Plan
    ✔CIVIL EXPERIMENTS
    • Experiment
    ✔SURVEYING
    • Surveying
    ✔CIVIL ENGINEERING TALK
    • Civil Engineering Talk
    ****************************************************************
    CONTACT DETAILS
    ✔Email Id for Business Enquiry - civilengineeringofficial@gmail.com
    ✔Linkedin: / civilengineermukeshsah
    Disclaimer:-
    Copyright Disclaimer under section 107 of the Copyright Act of 1976, allowance is made for “fair use” for purposes such as criticism, comment, news reporting, teaching, scholarship, education and research. Fair use is a use permitted by copyright statute that might otherwise be infringing.

ความคิดเห็น • 253

  • @premnathdaram2929
    @premnathdaram2929 ปีที่แล้ว +6

    Your all lectures are so helpful to each and every civil engineer....🙏
    Hook length should be 10D as per IS code

    • @user-hw2vk2us2r
      @user-hw2vk2us2r 4 หลายเดือนก่อน

      8D also can take

    • @AbdusSamad-ew6wx
      @AbdusSamad-ew6wx 18 วันที่ผ่านมา

      Pahle tha 10d but latest 6d bol raha sir ne IS cod ka anusar

  • @kiranm25x
    @kiranm25x ปีที่แล้ว +10

    You are doing Gods work by educating new house builders 🙏 Thank you Sir

  • @XYZ.96
    @XYZ.96 6 หลายเดือนก่อน +3

    6d
    V v nice Way of teaching
    And the knowledge also👍

  • @pavanmutsakarla1722
    @pavanmutsakarla1722 8 หลายเดือนก่อน +2

    The way of yor explanation is love it sir.❤

  • @SatyamSingh-vg8je
    @SatyamSingh-vg8je 8 หลายเดือนก่อน +2

    Thanks sir for this knowledge sharing session 🙏

  • @vaschouhan15
    @vaschouhan15 2 หลายเดือนก่อน +1

    Very very nice and useful information sir ji 🙏😊👌👌

  • @bbjconcreteindia
    @bbjconcreteindia 8 หลายเดือนก่อน +2

    Very very informative video

  • @gauranggshah7135
    @gauranggshah7135 6 หลายเดือนก่อน +1

    Your lectures are like refresher course.
    Some place double binding wires are used.Your comment please .

  • @shailenderayadav788
    @shailenderayadav788 หลายเดือนก่อน +1

    Good.teacher.and.teaching.good

  • @shrikantmaurya6896
    @shrikantmaurya6896 7 หลายเดือนก่อน +2

    Sir ji, bhut achi video banayi hai apne, samjhane ka tarika apka bhut hi acha lagta hai sir Mujhe, me apki mostly video dekhta hu or share or comment bhi or like bhi krta hu sir ji, or sir ji ab to me pure confidence se interview deta hu, sir ji me abhi CBRI roorkee me job kr rha hu, thank you🙏🙏🙏🙏 sir ji

  • @apuromeogamer8005
    @apuromeogamer8005 9 หลายเดือนก่อน +9

    Sir last wala samjha nehi mai ek mistri hoon, aur mai apki video kafi dino se dekh raha hoon, please sir last wala acche se samjha sakte ho

  • @RONIKFF777
    @RONIKFF777 หลายเดือนก่อน +1

    So super

  • @aaliyahkhan8565
    @aaliyahkhan8565 6 หลายเดือนก่อน +1

    Very detailed teaching

  • @engramjadalikhan7739
    @engramjadalikhan7739 4 หลายเดือนก่อน +1

    Very good 🌹 From Pakistan

  • @RoamNRides
    @RoamNRides ปีที่แล้ว +1

    Very Imp Topic

  • @hrishabhkumarsingh4118
    @hrishabhkumarsingh4118 6 หลายเดือนก่อน

    Position of hook should be in compression zone.
    Like in continuous beam, tension zone is around upper part of beam-column junction.

  • @sazzadhussain46
    @sazzadhussain46 11 หลายเดือนก่อน +1

    Good Sir, Bangladesh

  • @sauravbasu1344
    @sauravbasu1344 9 หลายเดือนก่อน +1

    Very informative video.

  • @rizwankhan-cv5mv
    @rizwankhan-cv5mv 10 หลายเดือนก่อน +1

    Love from Pakistan ❤

  • @prabhatkumarpanda4438
    @prabhatkumarpanda4438 6 หลายเดือนก่อน +1

    Sir Plz look up where the bottom lapping zone...u said that the lapping zone in bet L/6... I thought the lapping near column we can't provide..it may be after L/6..once check

    • @meaifollowyourdreams5196
      @meaifollowyourdreams5196 4 หลายเดือนก่อน

      Yes agreed with you...I learn from some videos it says that lapping of bottom bar near the support is not allowed....length of effective depth multiple by 2 should be measured from column and just after that length we can provide lapping of bottom bar in beam......
      (Depth of beam-bottom cover-half dia of main bar=effective depth × 2).
      I'm not an engineer but I learn everyday from multiple videos of engineer....the reason I learn and watch several videos of house construction it is because I want to build my own house with my own hand and idea only..so learning and taking ideas from many people is good..😊😊

  • @gauranggshah7135
    @gauranggshah7135 6 หลายเดือนก่อน

    Lovk ringgit details excellent point.
    Also on some extra stirrups are provided. Your comment please.

  • @user-hw2vk2us2r
    @user-hw2vk2us2r 4 หลายเดือนก่อน +1

    About your question: as per 13920: 2016, the minimum hook length in the RCC beam and column. Answer is c) 6d

  • @upenpaikofficial
    @upenpaikofficial ปีที่แล้ว +1

    I love you ❤❤❤❤❤
    From Kolkata

  • @tharindukanchana4516
    @tharindukanchana4516 8 หลายเดือนก่อน +1

    Thank you 🙏

  • @katyanrajroy4123
    @katyanrajroy4123 4 หลายเดือนก่อน +1

    Nice one and useful

  • @parmarpravin7666
    @parmarpravin7666 ปีที่แล้ว +1

    Good...Mukesh sir

  • @ksumit31
    @ksumit31 2 หลายเดือนก่อน

    stirupps in beam connecting columns should be plcaed closer near the columns and spacing should increase in the middle ?

  • @dipalimore3420
    @dipalimore3420 7 หลายเดือนก่อน +1

    Sir, slab checking baare mein bhi video batao plz

  • @omkarshinde7672
    @omkarshinde7672 10 หลายเดือนก่อน +1

    Best information

  • @YogeshLohar93
    @YogeshLohar93 ปีที่แล้ว +1

    Sir,ek aur point hai column junction se pehla beam ka stirrups maximum 50mm ke andar aana chahiye..

  • @ejazsaleem9621
    @ejazsaleem9621 7 หลายเดือนก่อน +1

    Plz explain about RCC slab reinforcement

  • @anilsamantaraya9832
    @anilsamantaraya9832 13 วันที่ผ่านมา

    Sir, master ring as per IS code ? Clause no ?bataye?site master ring beam pe koi deta nehi.kya is ko bill me claim hota hei kya?

  • @Entertainmentmanoj423
    @Entertainmentmanoj423 หลายเดือนก่อน +1

    सर❤❤❤❤❤❤

  • @pammipandey1605
    @pammipandey1605 ปีที่แล้ว +1

    Gjb boss mja aa gya

  • @arunkumarkarn1995
    @arunkumarkarn1995 ปีที่แล้ว +3

    A/c to new abundment IS 13920:2016 ,6d hona chahiye or 65 mm in place of 10d or 75mm

  • @muhammadmurtazanasir9393
    @muhammadmurtazanasir9393 4 หลายเดือนก่อน +1

    Best video

  • @pappalarameshwarrao
    @pappalarameshwarrao ปีที่แล้ว +1

    nice teaching

  • @AD13D
    @AD13D ปีที่แล้ว +1

    Super...

  • @nawazshariff9217
    @nawazshariff9217 3 หลายเดือนก่อน

    In beams top bars lapping length should be 50d and for bottom bars lap length should be 28d..

  • @kamleshgoyal9389
    @kamleshgoyal9389 5 หลายเดือนก่อน

    Sir column ki bars ko cut kaise krna hota h after 2 nd floor or 3rd floor columns and so on .I mean kitni length tak cut krke rkhna hota h

  • @baldevnayak137
    @baldevnayak137 วันที่ผ่านมา +1

    Aaj ka answer is 6d

  • @hinaajannabum3871
    @hinaajannabum3871 3 หลายเดือนก่อน

    Neutral Axis kya hota he? Or reinforce steel ko kese layer mey dalna he?

  • @kughazhechophi7469
    @kughazhechophi7469 4 หลายเดือนก่อน

    Mukesh brother could you kindly clear my query. If the column size is 9×12 inch does it include cover block space of concrete or otherwise.
    BDW i'm not from civil engineering background so kindly suggest your valuable info in this regard. Thank you in anticipation.

  • @apurvabhagwat6943
    @apurvabhagwat6943 5 หลายเดือนก่อน +1

  • @majibuddinahmed6584
    @majibuddinahmed6584 10 หลายเดือนก่อน +1

    Wow ❤❤

  • @MohitSharma-po2eb
    @MohitSharma-po2eb ปีที่แล้ว +2

    In some cases, development length is exceed to beam depth then what will be the development length

    • @LearningCivilTechnology
      @LearningCivilTechnology  ปีที่แล้ว +2

      Make it in C shape...

    • @naveeng8549
      @naveeng8549 6 หลายเดือนก่อน

      😂 How to place the bar when two ends is the same situation

  • @soumyadipdas7307
    @soumyadipdas7307 9 หลายเดือนก่อน

    Sir mere ghar ke chad ke middle beam mein plastic nehi diye the, cement slurry gira tha waha se bohot, abhi tak koi problem nehi hua but in future koi problem ho sakta hai ???

  • @XYZ.96
    @XYZ.96 6 หลายเดือนก่อน

    If you feel easy
    Then BN Dutta explain

  • @tirkey09
    @tirkey09 4 หลายเดือนก่อน +1

    6d Sir

  • @pratikchikhale8860
    @pratikchikhale8860 ปีที่แล้ว +1

    Master ring to column may provide karte hai na over the slab

  • @AD13D
    @AD13D ปีที่แล้ว +1

    6d or 65mm by is code 13920..

  • @LalitKumar-ps2ho
    @LalitKumar-ps2ho 5 หลายเดือนก่อน

    Sir, j bolt ki details in foundation m kasa lagata h Or j bolt ki kya kya check karte h

  • @gauranggshah7135
    @gauranggshah7135 6 หลายเดือนก่อน +1

    Hook length 6d

  • @Jaswindersingh-pp4cs
    @Jaswindersingh-pp4cs ปีที่แล้ว +2

    Typical footing drawing mai likhte ish kya matlab hai ❓❓❓❓ battye bahi

  • @nyabombam3897
    @nyabombam3897 6 หลายเดือนก่อน +1

    C) 6d.

  • @PintuKumar-uc2wl
    @PintuKumar-uc2wl 6 หลายเดือนก่อน +1

    C) 6D

  • @kishorjadhav635
    @kishorjadhav635 หลายเดือนก่อน +1

    6d sir

  • @stephenantony7513
    @stephenantony7513 9 หลายเดือนก่อน +1

    Jee ready Karo video about soil test

  • @user-cj6mi1ye6b
    @user-cj6mi1ye6b 10 หลายเดือนก่อน +1

    good

  • @ejazsaleem9621
    @ejazsaleem9621 7 หลายเดือนก่อน +1

    Master Ring.. plz explain

  • @souravpanda505
    @souravpanda505 7 หลายเดือนก่อน

    Sir, Master Ring & Lock Ring are not same! Master ring is the main ring of a beam but lock ring partly called as Horizontal ring

  • @bhoomiarora
    @bhoomiarora หลายเดือนก่อน +1

    Pl clear IS516 part4 B-2.5.1 ,

  • @SyedAli-vz2id
    @SyedAli-vz2id ปีที่แล้ว

    Sir where it mention in IS code spacing of cover block 0.8 m.

  • @ChansparepartsTangra
    @ChansparepartsTangra 10 หลายเดือนก่อน

    Bhai 18x120 feet shop ready krna hai
    Piller dimension bta do plz
    Down beam ki bhi
    Niche basement and uper ek ground floor hai

  • @dharmesh11
    @dharmesh11 ปีที่แล้ว +1

    e L/6 Lap zone konse code me hai?

  • @sandeepchaurasiya3123
    @sandeepchaurasiya3123 ปีที่แล้ว

    Sir mix design me standard deviation ka kya role h. Please ek detail video laiye is pr.

  • @denanathsingh9554
    @denanathsingh9554 ปีที่แล้ว +1

    Thanks! Sir.6d hota hai.

  • @balasubramanianmurugan5395
    @balasubramanianmurugan5395 8 หลายเดือนก่อน +1

    C) 6d

  • @HimanshuS5
    @HimanshuS5 ปีที่แล้ว

    Beam and column ka jaha junction banta hai ya T banta hai vaha column me stripes nahi daal pate hai beam ke steel ki vajh se to vaha kya kare .

  • @Raunakvilog4124
    @Raunakvilog4124 7 หลายเดือนก่อน +1

    (C) 6D

  • @abhijeetlahane7372
    @abhijeetlahane7372 ปีที่แล้ว +1

    As per Is 13920:2016 is 6d

  • @veerkumarchoudhary5704
    @veerkumarchoudhary5704 ปีที่แล้ว +1

    Ans.c)6d ~65mm.

  • @YogendraYadav-jq6nn
    @YogendraYadav-jq6nn 9 หลายเดือนก่อน

    May I request you to show master ring in beam in 3D view

  • @aaliyahkhan8565
    @aaliyahkhan8565 6 หลายเดือนก่อน +1

    I need bent up bar knowledge.

  • @pansulsatpathy309
    @pansulsatpathy309 6 หลายเดือนก่อน +1

    6D FOR HOOK LENGTH

  • @MukeshDhimanKumar-bp9st
    @MukeshDhimanKumar-bp9st 6 หลายเดือนก่อน +1

    Hook binding 135degree

  • @Samran-bh4ru
    @Samran-bh4ru 4 หลายเดือนก่อน

    कॉलम यदि 6 मीटर से भी ज्यादा दूरी हो , मान के चलो 7,9 मीटर है तो ऐसा स्थिति में कितना का लैपिंग रहेगा।

    • @PuneMagic
      @PuneMagic หลายเดือนก่อน

      Top bar me L/3 kru and Bottom mai L/6 kro , in Top bar apka 7900 mm kit length hai na toh centre mai 2633 pr lap hoga and Bottom at both sides L/6 krna 1316 k baad side se lap kr skte ho

  • @user-xn5zo3mq7h
    @user-xn5zo3mq7h 2 หลายเดือนก่อน

    Top bair zont L/3 ushae aige sir

  • @devcpwd
    @devcpwd ปีที่แล้ว

    As per seismic zones ke Hisar se Kya hai lap zone

  • @amitghosh4446
    @amitghosh4446 7 หลายเดือนก่อน +1

    Thank you sir .
    Isme 2 imp point missing hai
    1. Face Bar
    2. Main bar placing at junction

  • @ramgopalgupta7838
    @ramgopalgupta7838 หลายเดือนก่อน +1

    6D

  • @VikashGautam-g7c
    @VikashGautam-g7c 22 วันที่ผ่านมา +1

    6 D

  • @sigmarules4048
    @sigmarules4048 6 หลายเดือนก่อน +1

    Ans 6d ans

  • @abhishekpanigrahi1288
    @abhishekpanigrahi1288 11 หลายเดือนก่อน

    Stirrups hook length has been updated in the latest amendment as 8d, pehle 6d tha aab 8d hai.

  • @subhrodiptadas1594
    @subhrodiptadas1594 10 วันที่ผ่านมา +1

    6d

  • @khairullaskar596
    @khairullaskar596 9 หลายเดือนก่อน

    Pole ka size 5 floor ke liye kitna dina he

  • @brown.gentleman
    @brown.gentleman 3 หลายเดือนก่อน

    Sir agar 3D main dakha dete toh pura clear ho jata

  • @user-bn3wx1xd8u
    @user-bn3wx1xd8u 8 หลายเดือนก่อน

    Can we use marble pieces as cover block?

    • @Nick32176
      @Nick32176 7 หลายเดือนก่อน

      absolutely no.

    • @user-bn3wx1xd8u
      @user-bn3wx1xd8u 7 หลายเดือนก่อน

      @@Nick32176 dear friend cover block are not available in Pakistan. Generally people use marble pieces. What is solution?

  • @nall1222
    @nall1222 10 หลายเดือนก่อน +1

    Staad pro kyu nahi सिखाते

  • @narinderjoshi3914
    @narinderjoshi3914 5 หลายเดือนก่อน +1

    10 D

  • @mohd.ibrahim737
    @mohd.ibrahim737 2 หลายเดือนก่อน +2

    6 d

  • @Nagendrakumar-vj2re
    @Nagendrakumar-vj2re 7 หลายเดือนก่อน

    Please Mack videos pile load test

  • @AbdusSamad-ew6wx
    @AbdusSamad-ew6wx 18 วันที่ผ่านมา +1

    yeh to up bata diya 6d hoga. pahle 10d tha.

  • @anupamraygupta8473
    @anupamraygupta8473 ปีที่แล้ว +2

    6D.

  • @GkYaduwanshi
    @GkYaduwanshi 7 หลายเดือนก่อน +1

    Good morning sir 6d par hona chahiye

  • @narinderjoshi3914
    @narinderjoshi3914 5 หลายเดือนก่อน +1

    10d

  • @devcpwd
    @devcpwd ปีที่แล้ว

    IS 13920 me to likha hai joints or middle quarter me lap nahi karna hai.pleade clear

    • @shortvd969
      @shortvd969 8 หลายเดือนก่อน

      Han ek dmm sahi kah rhe ho

  • @mdazad459
    @mdazad459 7 หลายเดือนก่อน +1

    C 6d

  • @user-me8ix3vh7p
    @user-me8ix3vh7p หลายเดือนก่อน +1

    6

  • @shafeeqkhan5794
    @shafeeqkhan5794 3 หลายเดือนก่อน +1

    6d latest code