Fire technology and

แชร์
ฝัง
  • เผยแพร่เมื่อ 27 ธ.ค. 2024
  • Fire technology and safety engineering interview l #Fire safety engineer
    फायर इंटरव्यू क्वेश्चंस
    फायर इंजीनियरिंग एक ऐसी फिल्ड है जिसमें आग लगने के प्रकार, आग बुझाने के तरीके, आग बुझाने के इक्वीपमेंट, आग में घिरे लोगों को सुरक्षित बाहर निकालना आदि बातों का प्रशिक्षण दिया जाता है।
    Fire engineering.
    1. High rise building ki minimum high kya hoti hai.
    2. Dry riser ka internal dalmeter kya hota hai.
    3. Public way ki minimum width or height kitni hogi.
    4. Ramp na ration kitna hona chahiye hori zatal mai one level to anthoer level par.
    5. Bank ki building kis group mai aati hai or kis kis sub division mai aati hai.
    6. According to NBC, drums capacity with baskets on each floor kitni honi chahiye.
    7. Business building me floor area ration type 2 building me kitna hona chahiye.
    8.Stand by supply mai DG set room ka fire resistance kitna hona chahiye.
    9. Occupant local business building me kitna hona chahiye per person.
    10. Trival distance based on occupany and cantrouction business building me kitna hona chahiye.
    11. Business building me stare ki choadi kitni honi chahiye.
    12. Bank building me riser ki hight kitni honi chahiye.
    13. Group E 1 building me trade ki wiedth kitni honi chahiye.
    14. Group E1 building me 1 hight me jyada kitni riser honi chahiye.
    15. Ramp ka ratio kya hoga.
    16. Ramp ki dirction change hoti hai to landing ka size kya hoga.
    17. Stair me air pressure kitni paxel hoga.
    18. Lobbies me air pressure kitni paxel hoga.
    19. Room me air pressure kitni paxel hoga.
    20. Fresh air intake ki exhaust outlets ya grill ka distance kitna hona chaiy.
    21. Smoke exhust system 1 hours me kitni bar air change krta hai.
    22. 10 meter se jyda unchi bank building me yard hundred kitni unchi building ke liy use kiya jata hai.
    23. According to NBC, bank building me yard hydrent kitni unchi building ke liy use kiya jayga.
    24. Bank me kis colure ke springler use honge.
    25. Springler ke bich ka distence kitna hoga.
    26. Smoke detector ke bich ka distence kitna hoga.
    27. Automatic detcation and alarm system kitni hight ki building ke liy required hota hai.
    28. According to NBC under ground water tank ki capecity kitni honi chahiye and terrace tank ki capecity kitni honi chahiye.
    29.15 meter se unchi building me under ground tank ki capecity kya honi chahiye.
    30. 15 meter se jyada 24 se km hight ki building me terrace tank ki capecity kya hoti hai.
    31. 3.5 kg per cm2 pressure pump 10 meter se 15 meter unchi building me 1 mint me kitna pani dega.
    32. 15 meter se unchi building me terrace tank se 3.5 kg per cm2 pressure ka pump kitna pani dega.
    33. Kis size ki building me fire officer ki requirment hoti hai.
    34. Hose reel ke riser, down comer main ka diameter kitna hona chahiye.
    35. Hydraulicelly romote location ka pressure minimun and maximum kitna hoga.
    36. Red colour ke springler ka tempreature kya hota.
    37. Business building me minimun kitne door hone chahiye 1 floor per.
    38. Drill ke liy kitni team honi chahiye or unke name or working ke bhare me btao.
    39. Kitne meter hight ki building me atrium me springler ki requirment nhi hoti.
    40. ELCB ki full form kya hoti hai.
    41. Fire man switeu kha per lgta hai.
    42. Transfer ki divar ki rating resistance kitna hoga.
    43. Kitni unchi building me helipad banana compulsary hai.
    44. LPG gas ki aag kis type ki aag hai.
    45. Tail ki aag kis type ki aag .
    46. Bank me konsa extinguisher use hoga.
    47. Metal ki aag ko bujane ke liy konsa extinguser use hoga.
    48. Eleetric aag ke liy konsa extinguser use hoga.
    49. Tail ki aag ko bujane ke liy konsa actinguser use hoga.
    50. Bank ki aag ko bujane ke liy extiguiser ka symbol konsa hoga.
    51. Elective ki aag konse class me hoti.
    52. AFFF.
    53. Dense smoke jha hoti hai vha kis trh ke smok detcation lgte hai.
    54. Fix day kab banaya jata hai.
    55. ISO 9000 family stander kis ke liy use kiya jata hai
    अनियंत्रित अग्नि को नियंत्रित करने और उसके विनाश को कम करने के लिए उपयोग की गई योजना (पद्धति) को अग्नि सुरक्षा या (Fire Safety) कहते है|
    Fire Engineering Course
    0ur New channel - / vlogbymanojsharma
    What is BTech Safety and Fire Engineering? फायर इंटरव्यू क्वेश्चंस एंड आंसर्स
    Bachelor of Technology [B.Tech] (Safety and Fire Engineering)
    How many types of fire , what is fire , Type of fire extinguisher
    What is the sprinkler system. How sprinkler system work
    Body Language -
    • Body Language (Gesture...
    Bank Interview -
    • Bank Interview #IBPS #...
    फायर एंड सेफ्टी बुक इन हिंदी
    सेफ्टी ऑफिसर कोर्स क्या है
    फायर एंड सेफ्टी कोर्स फीस डिटेल्स
    fire technology and safety engineering
    fire technology and safety engineering jobs
    b tech in fire and safety engineering
    b tech in fire engineering
    fire engineering interview questions
    Our social links -
    Website - pdclassessgnr.in
    Facebook: / pd.classes
    Instagram: / pd.classes

ความคิดเห็น •