Sir namaskar Jo aap video banaya hai generatar ka panel ke bare me bataye Auto me kasie chalu hota hai Menual me kaise chalu hota hai Koi porobalm generatar me aata hai to kaise chalu kare Koi opption hai ya kio tarika hai
Auto me.. PLC se command dete heen... contractor se running command controller ko jata he.. phir controller se self Excitor ko start cmnd jata he...self Excitor motor ko pehle se 24 v battery connect reh ta he'NO' point me.. phir DG NC ho ke crank ho ta he.. then controller automatic running relay ko pick kar ta he... DG start ho jata he..aur jyada jan Kari chahiye to comment kare..
Sir Great video to help in operationn maintaining ..we have 500 kva two sets in appartment , need to know if one at stime running in half or less load what should be diesel consumption...hardly set runs less then 700 hrs in year including regular 5 min check up run
Sir 2 saal pura na 4000 hr used dg cumins sudhir 30 kv 3Ph hai second hand me le sakte hai 2.5 lakh me ??? Repair nahi hua hai abhi tak ?? Acha decision do me confused hu
Vacuum indicator shows you status of the air filter. When it reaches and locks in the red zone, the air filter should be changed and the indicator reset to zero. Reset the indicator by pushing the yellow reset at the end of the indicator.
Turbo charger intake air ko boost krne k liye lggta hai, is se engines ki efficiency aur achi ho jaati hai. You tube pr turbocharger animation dekho ache se smj ayega
Engine hunting at idle is usually caused by a fuel delivery, air leak, or governor system problem. Cleaning the carburettor, adjustment of the governor, changing the air filter may be required. Hope it's helpfully
Governor main purpose in engine is to limit the maximum speed of the engine to protect engine from breakdown and low idling speed to protect engine from stalling when loaded. The governors does this activity by controlling the fuel to the engine. Engine control unit works on a feedback given by the Engine (Sensors) it controls the actuators according to the values of sensors. That's can regulate the flow of fuel. 1. Engine control unit is not working properly sometime to feedback the flow of fuel. 2. There may the dust particles in the diesel which will block the governor.
Underspeed: High-pressure oil enters propeller line to decrease the pitch. A governor is in its underspeed condition when the engine is operating at a speed lower than the governor calls for.
Aj me 1010 KVA ke 4 dg or 2.5mw ke turbine chala raha hu. Dg turbine or electrical ko hold krta hu. Ab me gujrat job kr raha hu. 4 year ka experience hi. APKI COMPANY ME VACANCY HI TO. MSG KRNEA. OK EK BAR SAVEA Ka moka de.
If any one looking for job as geeneator technician in delhi-ncr. Please contact me @9015318500(arihant generator services) किसी को जनरेटर तकनीशियन या जनरेटर मैकेनिक की जॉब चाइये तो कॉल करे(9015318500)
Very informative video, Thanks for sharing Sir
Excellent sir
Good work ji
Sir app bhut ache trh se dg ke part smghaya hai
Thankyou achi knowledge mili
Bahut badiya Sir
Thank you very much sir great job again thanks sir ji
Enjn ke plet on nhi horhi he ripering
Awesome video sir.. Plz upload more
Thanks for information
Bhai ji 30 kva mai single phase silent DG kaunsa hai jiski performance good ho aur diesel bhi kam leta ho please
Eicher
Verrry help full and good sir ji
Sir namaskar
Jo aap video banaya hai generatar ka panel ke bare me bataye
Auto me kasie chalu hota hai
Menual me kaise chalu hota hai
Koi porobalm generatar me aata hai to kaise chalu kare
Koi opption hai ya kio tarika hai
Auto me.. PLC se command dete heen... contractor se running command controller ko jata he.. phir controller se self Excitor ko start cmnd jata he...self Excitor motor ko pehle se 24 v battery connect reh ta he'NO' point me.. phir DG NC ho ke crank ho ta he.. then controller automatic running relay ko pick kar ta he... DG start ho jata he..aur jyada jan Kari chahiye to comment kare..
Good sr
Sir ji apne jo dg par details bola hai o engine kitna kva ka hai ..???????
625 KVA
@@guideonline5921 thank you for your reply
Sir Great video to help in operationn maintaining ..we have 500 kva two sets in appartment , need to know if one at stime running in half or less load what should be diesel consumption...hardly set runs less then 700 hrs in year including regular 5 min check up run
Sir aapka mo. No. Milega kya
Ok sar 👍
Good video sir
Very good sir
good sir..we appreciate your work
great job sir
I have 500kva cummins d.g., so for aluminium radiator what coolant is used, as I am using Fleetcool XB DCA15L is this coolant OK ?
GOOD VIDEO
How much oil pressure need 500kw generator to running position
Sar Ji good
Sir 2 saal pura na 4000 hr used dg cumins sudhir 30 kv 3Ph hai second hand me le sakte hai 2.5 lakh me ??? Repair nahi hua hai abhi tak ?? Acha decision do me confused hu
Nice sir
Can i used B5 grade biodiesel used in 2000kva generators
No. Don’t use any bio diesel it will chock up nozzle and pump plungers. That will cost you more than the actual diesel difference
Phn charge kar sakte h koi pareshani to nhi aaygi mobile me
Awesome sir..
But u are not uploading suvh videos..Why??
Silencer ke pipe pe turbocharger ke bad insulation mein kya hai
Bahe coolant level low show krta hai full krny k bd b low show hota hai jenretor start nahi hota kya problem hai kindaly btana
Aapka sensor kharab hai. Coolant sensor change kro. Sahi ho jaega
Sir vacuum indictor kya feedback deta h
Vacuum indicator shows you status of the air filter.
When it reaches and locks in the red zone, the air filter should be changed and the indicator reset to zero. Reset the indicator by pushing the yellow reset at the end of the indicator.
Sir coolant aur oil line ko bataye
Great job
Nice
Aur video banaiye sar d.gset.ke.bare.me
#deep sea generator ke bare mai bta do sir please ek video bna do
Please watch our Channel for Generator videos.
Nice Bhai or video banao diji ka
Bhai mere pas same size ka generator he lekin wo start hone k kuch time bad high rpm kr k off ho jata he ap kuch bta sakte ho
Veryyyy goood
Mara janaytar ka raytar ma pani jayda Haram hota ha
Super
Sir mere pass 160 kva ka 2 generator hai unme turbochargers kisliye hote hain
Apne senior se pata kro
Or ek bat or fb se dhyan hato tb pata chalega
Mein fb nahi chalata only padta hu in class 6 samjhe komit
Turbo charger intake air ko boost krne k liye lggta hai, is se engines ki efficiency aur achi ho jaati hai.
You tube pr turbocharger animation dekho ache se smj ayega
I have kta50g3 it's hunting
Can you give me soulation
Engine hunting at idle is usually caused by a fuel delivery, air leak, or governor system problem. Cleaning the carburettor, adjustment of the governor, changing the air filter may be required. Hope it's helpfully
No worries. The K-19 Cummins series has this issue. It hunts for few seconds. Warm it up for 1-2 minutes. After that you can put load on it
DG kA canjaption kese nikalte h batana please dir
Sir agar dg trip marta hoga to problem kya ho sakata hai
Sar Chabi of karne per bhi engine chalta rahata hai kis Karan hai
Engine model
what is the reason of voltage drop in AVR and we have always provide bulb in AVR in moist condition mainly in rain and in winter season
Voltage drop is depend on the loss factor.
Mera be answered yhi hi
Me be phale sardi me avr pr bulb lagata ta.
Sir ek video alternate pe banaye
Sir Dg safety ke bare main video banayea
Sir, DG B check main kitna lube oil dalega. 1010 Kva,1250 Kva koi formula hai kya ?
Yea name h lube oil ka
Modal no.ky hai.modal ke hisab se oil Dlta hai.
Sir
Oil air gus jai to
Kiya korna parega
Sir 125 kva DG me baar,baar governor problem ku aata hai.
Governor main purpose in engine is to limit the maximum speed of the engine to protect engine from breakdown and low idling speed to protect engine from stalling when loaded. The governors does this activity by controlling the fuel to the engine.
Engine control unit works on a feedback given by the Engine (Sensors) it controls the actuators according to the values of sensors. That's can regulate the flow of fuel.
1. Engine control unit is not working properly sometime to feedback the flow of fuel.
2. There may the dust particles in the diesel which will block the governor.
Sir Cummins 500.kva ka d g hai aur o start ho kar band ho jata hai keya problem ho sakta hai
Give me your number plss
How many hours after the silent generator should be fully serviced
300 Hours to be B check if 15W40 CI4 oil is filled while previous B Check. If CI4+ is used then it can be changed at 500 Hours
Bhai ji mujhe eska kam sekhna hai plz help me
Sir DG ME BYPASS FILTER KYUN LAGTA HAI
PLS ANSWER ME
Qoki jab app ka DG rining me hota he tab oil fillter chock hogy to oil bypass ke throw oil suply hoti he
sir what is the need of double self start in dg please explain
Can you show please oil rifle
Sir sem janeter hai start hota hai lekin speed nhi hota hai Kya problem hai
Underspeed: High-pressure oil enters propeller line to decrease the pitch. A governor is in its underspeed condition when the engine is operating at a speed lower than the governor calls for.
It might be due to low frequency
Oil ma diesal ata ha uska jawab
In Diesel generator, diesel is the source to produce electricity
Nice video,please silent your mobile
Mobil ke ring pr dhyan hi. Ek br mil tuse he silent kru
sir me dg stoper bnata hu koi trik btaye ise sell karne k liye
why burn fuse .generator not run full speed .please explain
Sir generator ke ek ek function ke bare mein video baniye
Abhishek character beta book pado
Abhishek charan I m busy
Filter ka work to bataya nhi aapne or. Na hi vacuum indicater ke bare me agar laal ho jayega vacuum indicater to kya kre
Air Filter is to clean the air which is given to ignition and if red colour indicate on indicator then simply check the air Filter.
Alternate ke bare me bataye
dg ek ek part ke baare video sir bano
40kva dg ka tapid saiting pump taiming jankaree DE sirji
Air blding nikalana
Sir sellery kitni hoti hai
Sir you are wrong Friction ko kabhi bi khatam nhi kiyaa ja sakta
Usse kamm kiyaa ja sakta hai
Aj me 1010 KVA ke 4 dg or 2.5mw ke turbine chala raha hu. Dg turbine or electrical ko hold krta hu. Ab me gujrat job kr raha hu. 4 year ka experience hi. APKI COMPANY ME VACANCY HI TO. MSG KRNEA. OK
EK BAR SAVEA Ka moka de.
Bato sir
Aap apna resume send karo, mere mail pe
mdgufranansari7@gmail.com
generator pump problem
vedio
Are sir pover supply Nahi deta to kya kare chalu hota he lekin power Nahi deta
I wait your answer
I am Diesel mechanic and 2 year experience sir aap ki company me job Avelebal he sir
If any one looking for job as geeneator technician in delhi-ncr. Please contact me @9015318500(arihant generator services)
किसी को जनरेटर तकनीशियन या जनरेटर मैकेनिक की जॉब चाइये तो कॉल करे(9015318500)
sir aapka mobile number de do na
Good sir ji
Nice video sir