PLC & VFD MODBUS Communication Mode

แชร์
ฝัง
  • เผยแพร่เมื่อ 4 ต.ค. 2024

ความคิดเห็น • 284

  • @alix8147
    @alix8147 5 ปีที่แล้ว +4

    Direct and simple you can be a great teacher, thank you sir from Iran.

  • @mekonenabebe4653
    @mekonenabebe4653 7 ปีที่แล้ว +1

    hello Rajvir, thank you sir, I really appreciate your contribution for us . I am electrical engineer graduate and i am new for PLC programming and now I start learning by help of your videos. thank you again

    • @thegeterrdone
      @thegeterrdone  7 ปีที่แล้ว +1

      +Mekonen Abebe you are welcome 😇🤘

  • @ibrahimcop
    @ibrahimcop 3 ปีที่แล้ว +1

    izlediğim en güzel açıklayıcı video olmuş teşekkürler

  • @mahmudrajon9104
    @mahmudrajon9104 4 ปีที่แล้ว +2

    really genius for this field.

  • @ehsanzare9098
    @ehsanzare9098 3 ปีที่แล้ว +1

    Very very useful. you are the best and I thank you so much.

  • @lwinmoeaung9831
    @lwinmoeaung9831 5 ปีที่แล้ว +1

    Thanks! This video helps a lot. Please keep creating these kind of videos.

  • @akhtar2024
    @akhtar2024 2 ปีที่แล้ว +1

    Thanks for explaining it clearly and in depth.

    • @thegeterrdone
      @thegeterrdone  2 ปีที่แล้ว

      Thank you :) don’t forget to check out our new website for free courses. Only at www.codeandcompile.com

  • @rsrao8472
    @rsrao8472 3 ปีที่แล้ว +1

    Thank you very much Rajveer Singh

  • @hardiknagar9527
    @hardiknagar9527 4 ปีที่แล้ว +1

    I am so unlucky that I m watching this video very late ,very very useful video 👍 keep uploading sir .thank you personally for this video.

  • @nisargthakkar471
    @nisargthakkar471 5 ปีที่แล้ว +1

    SIR YOU ARE SIMPLY GREAT.DOING GREAT JOB.
    THANKS A LOT.

  • @arunprasath3944
    @arunprasath3944 3 ปีที่แล้ว +1

    Super explaination sir
    i have one doubt data stored in h2102 moved to D1500
    if i connect another vfd then which data register i can read values

  • @patelautomation8699
    @patelautomation8699 7 ปีที่แล้ว +2

    thank you so much sir

  • @atomall1
    @atomall1 6 ปีที่แล้ว +2

    You have a great talent for explaining. Thank you Sir.

  • @АтканБаткан
    @АтканБаткан 8 ปีที่แล้ว +1

    Thank you rajvir bhai

  • @muhammadzafariqbal4512
    @muhammadzafariqbal4512 9 ปีที่แล้ว +1

    very nice and deep explain

  • @syedmohsinasgherrizvi1449
    @syedmohsinasgherrizvi1449 7 ปีที่แล้ว +1

    Your efforts are appreciable, thanks for this wonderful lecture.

  • @felipearcher
    @felipearcher ปีที่แล้ว +1

    Hello Professor, would you know how to tell me which block to use to send ASCII commands on the serial port of the DVP20 SX2 for a printer? Configure the port already managed. Thanks in advance

  • @ahmedsaeed297
    @ahmedsaeed297 7 ปีที่แล้ว +1

    if i read the data from different slaves the data will saved in d1050 and d1051 and so on what ever the number of data addressees i read from the same slave and different slaves

  • @siddhanthuge4064
    @siddhanthuge4064 5 ปีที่แล้ว +1

    thanks for making such important videos

  • @getkapoor
    @getkapoor 9 ปีที่แล้ว +1

    Very well explained.

  • @plckhmer3651
    @plckhmer3651 2 ปีที่แล้ว +2

    Great job

  • @alirezashabani2869
    @alirezashabani2869 4 ปีที่แล้ว +1

    its verfy good learning a bout modbus tanx

  • @rajav8611
    @rajav8611 10 ปีที่แล้ว +1

    Dear Mr. Rajvir. You have done a very good work it helped me a lot. Can you please post a tutorial about Delta HMI-PLC-VFD communication example.

    • @thegeterrdone
      @thegeterrdone  10 ปีที่แล้ว

      Thank you Raja V I appreciate your gesture! And regarding Delta- PLC - VFD Tutorial - Are you asking Hardwire or Modbus? Between we have 200+ other tutorial in our professional course - Advanced Industrial Automation Check details here: online.nfiautomation.org

  • @abengineers920
    @abengineers920 5 ปีที่แล้ว +1

    Good work.Thank you

  • @satnaamsingh3896
    @satnaamsingh3896 7 ปีที่แล้ว +1

    Sir, i am your student at NFI , i need to perform Modbus operation using delta PLC and Siemens vfd!! I am facing a lot of problems! No parameters are there for ASCII mode in manual moreover no address for functions!

  • @dharmendrasuthar4342
    @dharmendrasuthar4342 2 ปีที่แล้ว +1

    Need a detailed video on PID control in delta plc.

  • @loxkumwenda2549
    @loxkumwenda2549 9 ปีที่แล้ว +1

    This is simplifies my understanding. Sir, any video on unity pro - ladder and structured languages?

    • @thegeterrdone
      @thegeterrdone  8 ปีที่แล้ว

      Sorry we do not have Unity ladder programming tutorials.

  • @ashiqhusainahmedalivankani8697
    @ashiqhusainahmedalivankani8697 ปีที่แล้ว +1

    Thanks for very good explanation... Keep it up...❤❤❤

    • @thegeterrdone
      @thegeterrdone  11 หลายเดือนก่อน

      Most welcome 😊

  • @aniketmirajkar280
    @aniketmirajkar280 7 ปีที่แล้ว +1

    is this case you have used any conveter between plc and vfd.

  • @misterAD88
    @misterAD88 4 ปีที่แล้ว +1

    Very good thanks

  • @ramjeepalukuri602
    @ramjeepalukuri602 5 ปีที่แล้ว +1

    If we use more than one drive what would be data address for plc for showing the output frequency and command frequency

    • @thegeterrdone
      @thegeterrdone  5 ปีที่แล้ว

      In PLC, you will find many registers for reading MODBUS data, you need to asisgn those dataregister in MODREAD command.

  • @achrafbara8025
    @achrafbara8025 8 ปีที่แล้ว +1

    hi mr RAJVIR SINGH thank you for all informations, please can you show us how we can command a servopack with a PLC for example S7 300 and a type of signale that we should send from PLC to servopack thank you very much

  • @ragisunil
    @ragisunil 10 ปีที่แล้ว +1

    Sir, I am good at electrical hard wiring ,VFD drives and basic PLC programming.
    but how to program high speed digital encoder in PLC which is used to measure the length of metal sheet and how to program HMI?

  • @minervatech6721
    @minervatech6721 5 ปีที่แล้ว +1

    Hi Sir, Thank you so much for your explanation.But I have some problem that even I did all procedures (PLC & VFD sides) as you had done, I cannot turn on the VFD by command (e.g K2) and change the frequency (e.g K2000 etc.).Please help me to reply.

  • @tarekmohsen7572
    @tarekmohsen7572 5 ปีที่แล้ว +1

    Thank you

  • @szas6754
    @szas6754 6 ปีที่แล้ว +1

    thanks so much for this awsome illustration⚘⚘

  • @SuperEngineer02
    @SuperEngineer02 8 ปีที่แล้ว +1

    Dear Rajvir sir, i am getting feedback of command & output frequency but i want to get feed back of output current & voltage so i have written H2104 & D1052 for current feedback & H2106 & D1054 for voltage feedback but it's not working.please suggest. FYI i have sent the screen shoot to your mail, thanks

  • @rajajiv6754
    @rajajiv6754 10 ปีที่แล้ว +1

    Yes sir, I am thinking for MODBUS is it possible to use HMI's COMM2 as RS485 interface and VFD comm. setup as RS485 where the PLC is the master HMI and VFD are as slaves as peer to peer.

  • @pranavdosajh
    @pranavdosajh 7 ปีที่แล้ว +2

    thanks for such an informative video!!! I have a small doubt is it possible to operate 2 vfd's simultaneously? and if I read the two vfd's output frequency together in which data register it will be saved?

  • @jannatmimi8618
    @jannatmimi8618 4 ปีที่แล้ว +1

    how to get feedback frequency ,if i use two vfd togather 1 and 2 ?

  • @amrishamrish2599
    @amrishamrish2599 6 ปีที่แล้ว +1

    Vfd with pressure tranducer _ how many percentage save energy for submersible pump motor (12hp)

  • @ajitpalsingh2526
    @ajitpalsingh2526 5 ปีที่แล้ว +1

    hello sir. i made the program of vfd modbus in wpl soft and the program works perfect as you explained in video. Now i tried a delta hmi dop b to communicate with plc with modbus but unfortunately i could not connect hmi with plc .so please guide me what to do. thanks . ajit pal singh

  • @shahbazarain9488
    @shahbazarain9488 4 ปีที่แล้ว

    Defined knowledge in a very easy way. Appreciated sir

  • @pankajsonwane3152
    @pankajsonwane3152 3 ปีที่แล้ว +1

    Thank u thank u thank u....sir

  • @malekae4429
    @malekae4429 3 ปีที่แล้ว +1

    Genius ! But can we read/write any parameters from VFD even if it is not mentioned in the parameters address table? E.g 90-03 parameter group 90 & group number 03 ( 9003H ) ?

    • @thegeterrdone
      @thegeterrdone  3 ปีที่แล้ว

      No you can only Monitor parameters which has their modbus addresses

  • @hariharand5186
    @hariharand5186 5 ปีที่แล้ว +1

    Respected Sir Is this Program Code that u have used here can be utilised only for this Model of Delta VFD??

  • @vellamuthun8635
    @vellamuthun8635 7 ปีที่แล้ว +1

    hello very thanks for your all videos
    can you put give a short notes about device net bulider and it communication with plc in delta

  • @srisaimeka3736
    @srisaimeka3736 4 ปีที่แล้ว +1

    I wanted to know how to communicate with delta plc using modbus rtu and check if i can read/write values in modscan64

  • @vivekkumarnirmal9538
    @vivekkumarnirmal9538 3 ปีที่แล้ว

    What a class sir .u teach me slot even my experience.great job sir heads of u sir

  • @sameerkhandelwal8061
    @sameerkhandelwal8061 6 ปีที่แล้ว +1

    Sir pls make a video of yashkawa a1000 modbus communication with Delta plc

  • @sincos1319
    @sincos1319 3 ปีที่แล้ว +1

    Great sir

  • @tanweerahmad516
    @tanweerahmad516 8 ปีที่แล้ว +1

    nicely explained.......................

  • @hanhtrangtvt227
    @hanhtrangtvt227 6 ปีที่แล้ว +1

    hi, can i do the same communication with VFD-EL ?

  • @stephensickle
    @stephensickle 6 หลายเดือนก่อน +1

    What are you saying at "19:56"? What "Bit" ? Im trying to find the bit definition so i can create my programme according to your instructions please @Raj

    • @thegeterrdone
      @thegeterrdone  4 หลายเดือนก่อน

      Please contact me at rajvir@codeandcompile.com

  • @JYOTIverma-xr3gj
    @JYOTIverma-xr3gj 7 ปีที่แล้ว +1

    Great video tons of thanks sir...vl u please make a vedio on loadcell module ( 02LC , 01LC) how to calibrate .

    • @thegeterrdone
      @thegeterrdone  6 ปีที่แล้ว

      +JYOTI verma I would like to but I don’t have load cell module

  • @sumanthms4042
    @sumanthms4042 2 ปีที่แล้ว +1

    Hi sir, with the plc program in video, I'm not able to access PLC from PC over RS232. How to access PLC from PC?
    Please guide

  • @VishalPatel-vv4fj
    @VishalPatel-vv4fj 5 ปีที่แล้ว +1

    Hello rajvir sir, please upload delta 14 ss plc with communication pid controller plc programming video

  • @mahesh7437
    @mahesh7437 4 ปีที่แล้ว

    thanks,very good information,i have one question, how to communicate more than one vfd to plc.

  • @electrotwist9566
    @electrotwist9566 5 ปีที่แล้ว +1

    your videos are wonderful,I've seen all of them and I really Like that.
    But i want to control VFD using my HMI via MODBUS, I know the connections and everything but you can do one more video on that as well..
    I will recommend you when I will start my tutorials on PLC
    Thank You.

  • @YashKumar-tt7li
    @YashKumar-tt7li 7 ปีที่แล้ว +1

    hello sir , i m using vfd el series and plc 14 ss2 . i m not able to communicate the vfd(el series) with plc (delta 14ss2) by ths programme
    .

    • @thegeterrdone
      @thegeterrdone  7 ปีที่แล้ว

      Did you check the appropriate parameters for communication? Also the wiring.. ? Also kindly check if your VFD supports RTU or ASCII communication mode. This information is in the VFD manual.

  • @edytonel2930
    @edytonel2930 6 ปีที่แล้ว +1

    Very good.

  • @RakeshP61
    @RakeshP61 8 ปีที่แล้ว +1

    sir please suggest me how to configure plc & vfd in allen bradley....by any communication medium. and sir your video is to good m learning many things...thank you

  • @ayoobaarabi4178
    @ayoobaarabi4178 3 ปีที่แล้ว +1

    Tnx for the usefull video
    If i want to use ispsoft for this project, can i use this registers and functions just like wplsoft???

  • @SivaKumar-yd4wo
    @SivaKumar-yd4wo 7 ปีที่แล้ว

    very good explanation. I'm very clear about your explanation. thank you very much....

  • @amalbabu8587
    @amalbabu8587 7 ปีที่แล้ว +1

    epic explanation

  • @diogo_engca
    @diogo_engca ปีที่แล้ว +1

    Excelent!

  • @faresalsharif7036
    @faresalsharif7036 6 ปีที่แล้ว +1

    thank you so much for this useful video, but how can i get the data adress of my VFD-L?
    is it the same as VFD-M series

  • @usamashehbaz9172
    @usamashehbaz9172 10 ปีที่แล้ว +3

    Rajvir thanks a lot .It's really worth it :)

  • @waisongt1517
    @waisongt1517 5 ปีที่แล้ว

    Can u tell me of similar make but of 20hp induction motor air compressor which VFD can be best used???

  • @thiennguyen-hy1mc
    @thiennguyen-hy1mc 6 ปีที่แล้ว +1

    When run the simulation, the error timed out, how to fix?

  • @chlee1555
    @chlee1555 9 ปีที่แล้ว +2

    Great Video, very informative and good details.

  • @raedhatem7379
    @raedhatem7379 2 ปีที่แล้ว

    Hello bro, I read the voltage and the current from the VFD, and the value will be saved in D1050 and D1051 why both saved in D1050 ? In other words the value in D1050 once the current value and once the voltage value why the voltage will not be saved in D1051 ?

  • @abdulroshyab
    @abdulroshyab 10 ปีที่แล้ว

    Thank Mr. Rajvir! You have just opened a door for me in this side of the world. Thank you again!!! I am trying to understand these motor dives and I came across the DELTA VFD-B it is driving a motor on a 35kg washing machine and I have made a timer that will provide washing cycles, rinse and spin now can help me on how to step speed the motor using DELTA VFD-B? Pleaaaase?

    • @thegeterrdone
      @thegeterrdone  10 ปีที่แล้ว

      Hi Rashid, kindly forward your query at nfiautomation@gmail.com. I will respond via E-mail.

  • @shuhaimisyakir2554
    @shuhaimisyakir2554 7 ปีที่แล้ว +1

    Hello...I have one question..how about communication direct using another type PLC cpu? also can use this method or not? Because their setting and write method the program is similar with Mitsubishi programming. Thank you.

    • @thegeterrdone
      @thegeterrdone  6 ปีที่แล้ว

      +shuhaimi syakir yes that’s possible as well :) prefer to link Plc via Ethernet for flexible data flow

  • @akshaysantoshpatil
    @akshaysantoshpatil 5 ปีที่แล้ว +1

    That's what all i needed thanku sir,

  • @viijayakarankapkar9621
    @viijayakarankapkar9621 8 ปีที่แล้ว +1

    VERY NICE

  • @emilioreyes4995
    @emilioreyes4995 8 ปีที่แล้ว

    Very good explanation

    • @thegeterrdone
      @thegeterrdone  8 ปีที่แล้ว

      +emilio reyes Thank you check more great stuff at www.nfiautomation.org

    • @princejst147
      @princejst147 8 ปีที่แล้ว

      Rajvir Singh

  • @siddhanthuge4064
    @siddhanthuge4064 5 ปีที่แล้ว

    you are great sir

  • @LytningBlue
    @LytningBlue 9 ปีที่แล้ว +1

    Brother , can we convert it to structured text?Do you have a sample syntax?

    • @thegeterrdone
      @thegeterrdone  9 ปีที่แล้ว

      No we do not work on structured text. Sorry could not help you in that case.

  • @mansoorraza4903
    @mansoorraza4903 7 ปีที่แล้ว +1

    Dear Sir,
    can you tell me which type of comparison command did you use for "logic generating pulses".

    • @thegeterrdone
      @thegeterrdone  7 ปีที่แล้ว +1

      It's Equalizer goes with 'LD= C0 k1'

  • @gauravsharma3555
    @gauravsharma3555 4 ปีที่แล้ว

    Great vedio done by you
    I want to read function code 04 input register in delta plc .
    Modrd,modwr command is support only function code 03 holding register.
    Pls suggest me the command for function code 04 ( input data register)

  • @arieljulve1745
    @arieljulve1745 10 ปีที่แล้ว +1

    HI Mr. Singh..thanks for this video it's very interesting even I am weak in numbers lol...Anyway, I will enrolling some courses in udemy after sometime because I am little bit busy with my electrical works..

    • @thegeterrdone
      @thegeterrdone  10 ปีที่แล้ว

      No problem ariel ;) Pleasure.. Soon i would be sharing more videos with you!

  • @alvaroenriquetascoquintero7216
    @alvaroenriquetascoquintero7216 8 ปีที่แล้ว

    Hello. I need comunication 5 VFD DELTA but I have problem with the send pulse for M1122. Help me please.

  • @preetparmar
    @preetparmar 9 ปีที่แล้ว +1

    hi i have got two KEB inverters on two motors on a machine its a master slave configration.i was just wondering where and how do you configure which to make a slave or master.??

    • @thegeterrdone
      @thegeterrdone  9 ปีที่แล้ว

      well, you can do that by assigning the different communication address to the VFD. Now you can control two VFD using Modbus. To make master slave operation its all about coding.

    • @preetparmar
      @preetparmar 9 ปีที่แล้ว

      what things do i need to take care of when i replace a vfd in a master slave configuration.
      like i said i have these 2 vfds one is master and othere is slave and master has given up i want to change master vfd

  • @gameeducation1343
    @gameeducation1343 4 ปีที่แล้ว

    Hi
    Please establish rs485 communication between delta plc and mitsubishi vfd E700.
    It should contain change of frequency of drive through modbus register.
    Hope you consider my request.

  • @ElectricalisEasy
    @ElectricalisEasy 4 ปีที่แล้ว

    while using modwr you write the value of d10 to h2000, is this h2000 dependent on the manufacturer of the vfd or it can be used when using any type of vfd with delta plc?

    • @thegeterrdone
      @thegeterrdone  4 ปีที่แล้ว

      Its dependent on the hardware so basically on VFD

  • @godwinahiat6640
    @godwinahiat6640 7 ปีที่แล้ว +1

    Good evening Sir, i've been watching videos online always, i must say you are really helping us. I am using Delta SIPSOFT TO Program , please i need a vodeo on Delta ISPSOFT as a beginner to home automation lighting control. Thank you

  • @ArunKumar-ml6qm
    @ArunKumar-ml6qm ปีที่แล้ว

    Sir your video is very nice,but I am confuse that modbus register is available in plc or VFD drive

    • @thegeterrdone
      @thegeterrdone  ปีที่แล้ว

      You have to check for Modbus register for VFD as we are reading and writing data from VFD. So VFD manual will have those :)

  • @abdulh4830
    @abdulh4830 7 ปีที่แล้ว +1

    very good thank you

  • @muhammadfiaz6227
    @muhammadfiaz6227 7 ปีที่แล้ว

    very informative this video thanks sir....I am in trouble to connect a analog module to fx3u Mitsubishi plc and also in floating point plz help me...

  • @gurudansingh7209
    @gurudansingh7209 4 ปีที่แล้ว

    Hi Rajvir Singh, All the time very nice informative video. Great 👍 thanks
    I am designing one special purpose Cnc machine. We need your help.
    Thanks

  • @habibrehman7820
    @habibrehman7820 4 ปีที่แล้ว

    Sir please make video of s7 300 and abb acs 550 profibus communication

  • @chickenz4604
    @chickenz4604 3 ปีที่แล้ว

    hello sir what is the differences between using RS-485 and analog input output module for communication between PLC and VFD?

  • @rajajiv6754
    @rajajiv6754 10 ปีที่แล้ว +1

    Dear Sir. I tried to make communication between PLC and VFD as per this tutorial. But I could not able to communicate with VFD, my problem is that the counter C0 is not counting and its hold at M0, also M1122 also always ON. I checked my configurations again and again all seems okay as per your tutorial. Can you please help me in this regard. Thank you.

    • @thegeterrdone
      @thegeterrdone  10 ปีที่แล้ว

      Can you please send the program at nfiautomation@gmail.com. I will check and get back to you! ;)

    • @hanhtrangtvt227
      @hanhtrangtvt227 6 ปีที่แล้ว

      i have the same trouble, can u help me ???

    • @electrotwist9566
      @electrotwist9566 5 ปีที่แล้ว

      I got a same Problem, Can you Help me???

  • @amanlimbad6047
    @amanlimbad6047 8 ปีที่แล้ว +1

    hello sir can I control vfd frequency with limit switch I want use vfd for my hydraulic press pump

    • @thegeterrdone
      @thegeterrdone  7 ปีที่แล้ว +1

      Yes you can do that ! Just connect limit switch common to VFD digital ground and then output to the M0 or M1 to achieve whatever you want!

  • @Jonathan-ru9zl
    @Jonathan-ru9zl 3 ปีที่แล้ว +1

    HI! thank you. Does 2 or more MODRD commands can be sent together at the same time?

    • @thegeterrdone
      @thegeterrdone  3 ปีที่แล้ว

      Yes, that is possible :)

    • @Jonathan-ru9zl
      @Jonathan-ru9zl 3 ปีที่แล้ว

      @@thegeterrdone how is it possible?

  • @EngOmar-kz9qv
    @EngOmar-kz9qv 2 ปีที่แล้ว

    Hi Mr Rajvir,
    Greeting to you from Iraq .
    please if want to read the faults codes of VFD , can i use MODRD instruction? or there is another way ?
    Regards

    • @thegeterrdone
      @thegeterrdone  2 ปีที่แล้ว

      Yes, I am sure you can find MODBUS register for the fault :)

  • @kirannb5354
    @kirannb5354 5 ปีที่แล้ว

    Sir, can u make a video for setup communication wizard, in delta WPLSOFT.

  • @satyajeetvispute6484
    @satyajeetvispute6484 10 ปีที่แล้ว +5

    Hello. Thank you so much for all your wonderful videos. I am sure many of us would be completely lost if it weren't for people such as yourself who are willing to extend a helping hand. My field is actually embedded systems and as such I have very little exposure to plc. Modbus too is new to me. I would like to be able to communicate with the delta vfd via pc (not plc). Basically what I am trying to do is interface a small keypad to a pc using a micro-controller and rs232 protocol and then have the pc send the commands to vfd via modbus to vary frequency. Is that possible? I cant find modbus commands in the delta vfd manual.....

    • @thegeterrdone
      @thegeterrdone  10 ปีที่แล้ว +1

      Neo Avelino Hi! Well if you are doing it with PC., you have two option.1) Either you can use VFD Software named VFDsoft., in which you have parameter settings, VIsual monitoring and built in Keypad to control the VFD.2) You can use C program to directly read/write the register of VFD. What you say is possible. But why Micro-controller, if you are using PC, use PC controller and C as program. How doers it sound?PS. Sorry for late reply, i was bit occupied!

    • @satyajeetvispute6484
      @satyajeetvispute6484 10 ปีที่แล้ว

      Thanx for the info. Your idea of using c program sounds fantastic...only problem is I dont know how I can do it. Actually I have never worked on the modbus protocol before and the delta vfd manual is very confusing to me. If u dont mind, I would like to take our discussion in a different direction- lets consider eliminating the pc part altogether and just try controlling the delta vfd using 8051 micro-controller alone. How can one vary the frequency of the vfd using micro-controller and modbus? What will be the modbus command for it?
      ps- thanx for replying back. means a lot to me.

    • @thegeterrdone
      @thegeterrdone  10 ปีที่แล้ว

      Neo Avelino Hello Neo, I don't have idea about Micro-controller programming, have not really done it before. The idea is to write the value in 2000H register of VFD which defines the Operation and 2001H which defines the Frequency of VFD. SImilar you can read the value of feedback register of VFD. So the only way is to communicate the Controller with VFD using (9600, 7, EVEN, 1) and then Read/write the values.

    • @satyajeetvispute6484
      @satyajeetvispute6484 10 ปีที่แล้ว

      Thanks for all the help. u truly are a great person. I shall give it a try using micro-controller. will let u know how it goes. thanx once again and God Bless.

    • @thegeterrdone
      @thegeterrdone  10 ปีที่แล้ว

      Thanks neo. ..

  • @sajalmahmud7286
    @sajalmahmud7286 6 ปีที่แล้ว

    Sir this is to possible to simulate that Offline ,if possible plz help me...........thank you