Assalam o Alaikum sir. Aapki video dekh k maine wapda sharing karly and it is running good. But the only problem is k jab wapda pe load shift hota hai to output pe dono phase aarahe hote hain aur lights off bhi hon to halki light on hoty hai aur mobile charging k time pe touch sahi se kaam nhe karta. Please iska hal bata dein.
Agar ongrid inverter ko simple wapda meter pr laga den or zero export device na ho to extra current ko kis trah nullify kr skty hain reverse metering se bachny k lye.
PV k voltage 310v DC sy ziyada hon gy to he PV ko WAPDA py preference milay gi. Solar string bnatay howay iska dehan rakhain. 220×1.41= 310v DC. 1.41 AC sy DC conversion factor ha.
@@drmunawarsaeedkhan5434 aap rectifier ziyada amperage k lagain. 100 Amp k laga lain aur sath m heat sink zara larger size k lagain. 100 Amp k 2000 Rupee tak mklay ga par zindagi asan ho jaye gi
@AsadAli-ej9vz Assalam o Alaikum sir. Aapki video dekh k maine wapda sharing karly and it is running good. But the only problem is k jab wapda pe load shift hota hai to output pe dono phase aarahe hote hain aur lights off bhi hon to halki light on hoty hai aur mobile charging k time pe touch sahi se kaam nhe karta. Please iska hal bata dein.
Keep it up good work Bhai. Ap ne Jo last time inverter ka circuit explain Kiya tha uski minimum trigger voltage Kitne he Matlab minimum Kitne pannel laga sakte hn. Is it possible ke usko hum 24 volt battery se connect krkske with DC to DC up converter in case rat ko use krna ho
Thanks.....ye local inverter high PV input k Liye design kiye gye hn in MN chopper k use bhi ni hy is Liye ye low input DC voltages py operate ni ho ga. Agr boost converter lga k battery attach krn to koi faida ni , is condition MN battery backup na hony k brabr ho ga
Solar k sath jo Rec lagaya hae. Us mas AC input wali side kahan connect kerni hae or dc output wali kahan connect kerni hae? Yeh missing lag rahe hae. Kindly clarify
السلامُ علیکم ۔ جی ماشاءاللہ آپ بہت اچھے طریقے سے بریف کرتے ہیں میرے جیسا ان رموز سے نابلد شخص بھی مستفیض ھو رہاھے۔ جناب آپ سے گزارش ھے کہ نیٹ پہ بغیر بیٹری والے انورٹر اور کٹس کی تو بھر مارھے لیکن ایسے آف گرڈ انورٹر جو بیٹری اوپریٹڈ ھوں بہت کم ہیں آپ سے التماس ھے کہ انورٹر کے ایسے سرکٹس جن میں پی وی ان پٹ 500 وولٹ تک ھو 12-12وولٹ کی دو بیٹری سے اوپریٹ ھو اور آؤٹ پٹ 5-3 کلوواٹ تک ھو اس پہ بھی وڈیو بنائیں بہت بہت شکریہ عبدالناصر
Reverse current stop karnay k liye bridge kis tariqay sey lagatay hain us mai tu 4 points hotay hai 2 for AC and 2 for DC.. Please guide thank you@@AsadAli-ej9vz
@@MuhammadImran-uq9rc input aap AC wali 2 pins py lagain gy aur DC wali 2 pins sy aap output agay circuit m laga dain gy. Ab AC wali pins sy current agay jaye ga par reverse nhe ho sakay ga, due diodes in bridge rectifier. Sorry for late response.
@@solarinnovation040 جی استاد محترم ۔ ایک برج والے انوٹر لگائے ہیں تو انکا بل بہت زیادہ ایا ۔ جب وولٹ پینل کی طرف گیے ہیں تو یونٹ بھی گرے ہیں۔ پھر واپڈذ شیرنگ کا کنیکشن ختم کر دیا۔
Yai tu apki video dekh kr poocha tha uss sy, but he warned me not to use it, could you share some test video on it . Kiya koi voltage drop ya variation atti hai supply mai. Ya modify hota hai current , ya ampere mai farad perta hai???
Can we convert our old pwm inverter to mppt with load sharing? Or add WAPDA load sharing option in PWM ? And which additional components are needed ? Kindly make a video on it Thanks JazakAllah
MashaAllah Bhai boht acha explain kiya hai.
GOD❤❤❤
Great information yar.. God bless you sir❤
بہت اچھے ۔ میں اسے ہی ڈھونڈ رہا تھا ۔ مشکل آسان کی شکریہ آپ کا
میں بھی 😮😮😮
Good video on wapda sharing
Thankyou ji inductor ke sath sar ji IGBT ki gate ke voltage ke bare mein jankari dijiye
Assalam o Alaikum sir. Aapki video dekh k maine wapda sharing karly and it is running good. But the only problem is k jab wapda pe load shift hota hai to output pe dono phase aarahe hote hain aur lights off bhi hon to halki light on hoty hai aur mobile charging k time pe touch sahi se kaam nhe karta. Please iska hal bata dein.
Bhai rectifier ki output 180-190 k darmian hae. Is ko kesay improve kia jaye.. agay koi capacitor lagaya jaye to kis volt ka or kia capacity ho gee .
شکریہ سر❤❤
Highly appreciated
Good info
Aoa bhai g......
Bhai jan awais ke app ko salam keh raha h...urr hr dafa ke trhaa is daffa b...very nice video
Thanks g..
Bhai thankuuu
Camera ko Landscape krain Bhai Video full screen nhi hoti
Information to zabardast hoti hy apki hr video me❤
Masha Allah
Agar ongrid inverter ko simple wapda meter pr laga den or zero export device na ho to extra current ko kis trah nullify kr skty hain reverse metering se bachny k lye.
Good job
PV k voltage 310v DC sy ziyada hon gy to he PV ko WAPDA py preference milay gi. Solar string bnatay howay iska dehan rakhain. 220×1.41= 310v DC. 1.41 AC sy DC conversion factor ha.
2 ghanty sharing Ki hy, solar side wala rectifier blast kr gya
@@drmunawarsaeedkhan5434 aap rectifier ziyada amperage k lagain. 100 Amp k laga lain aur sath m heat sink zara larger size k lagain. 100 Amp k 2000 Rupee tak mklay ga par zindagi asan ho jaye gi
@AsadAli-ej9vz Assalam o Alaikum sir. Aapki video dekh k maine wapda sharing karly and it is running good. But the only problem is k jab wapda pe load shift hota hai to output pe dono phase aarahe hote hain aur lights off bhi hon to halki light on hoty hai aur mobile charging k time pe touch sahi se kaam nhe karta. Please iska hal bata dein.
Mara Sara load wapda par shift Kar daita ha inverter PV honey k bawajood...6 plates Hain 575 ki...Kia plate ziada Karon??
Excelent
Keep it up good work Bhai. Ap ne Jo last time inverter ka circuit explain Kiya tha uski minimum trigger voltage Kitne he Matlab minimum Kitne pannel laga sakte hn. Is it possible ke usko hum 24 volt battery se connect krkske with DC to DC up converter in case rat ko use krna ho
Thanks.....ye local inverter high PV input k Liye design kiye gye hn in MN chopper k use bhi ni hy is Liye ye low input DC voltages py operate ni ho ga.
Agr boost converter lga k battery attach krn to koi faida ni , is condition MN battery backup na hony k brabr ho ga
Solar k sath jo Rec lagaya hae. Us mas AC input wali side kahan connect kerni hae or dc output wali kahan connect kerni hae? Yeh missing lag rahe hae. Kindly clarify
Bridge module py + and - k symbol ho ga wahan whn DC output ho gi ....dosri side ac input
Is rectifier k sath ac ni hy. Dono taraf DC hy
Bhai rectifier ki output 180-190 k darmian hae. Is ko kesay improve kia jaye.. agay koi capacitor lagaya jaye to kis volt ka or kia capacity ho gee .
السلامُ علیکم ۔ جی ماشاءاللہ آپ بہت اچھے طریقے سے بریف کرتے ہیں میرے جیسا ان رموز سے نابلد شخص بھی مستفیض ھو رہاھے۔ جناب آپ سے گزارش ھے کہ نیٹ پہ بغیر بیٹری والے انورٹر اور کٹس کی تو بھر مارھے لیکن ایسے آف گرڈ انورٹر جو بیٹری اوپریٹڈ ھوں بہت کم ہیں آپ سے التماس ھے کہ انورٹر کے ایسے سرکٹس جن میں پی وی ان پٹ 500 وولٹ تک ھو 12-12وولٹ کی دو بیٹری سے اوپریٹ ھو اور آؤٹ پٹ 5-3 کلوواٹ تک ھو اس پہ بھی وڈیو بنائیں بہت بہت شکریہ
عبدالناصر
Ok
1200v 50a ka bridge lagaya hy. Jo solar input per lagaya woh 22a load per overheat Hua, smell aor smoke Nikla.
Kiya yeh kamyab hy?
Very nice
3 phase me pv input ki 2 wire hoti hain to ye 3+3 Rectifier wali samagh nhi i
AP ksi 2 terminal py input pv lga skty hn
220VAC rectifier kh baad ziyada hongay means 300 DC Some thing
Yes voltages increase hn gy
Main ny bridges inverter K bahir solar input aor AC input K sath lagyi hyn, laikin 80 percent wapda sy ampere lay raha tha.
Aap ny jo PV string bnaie ha wo kam az kam 330V DC hona chahye. Even 350V behtar rahay ga. M 3 months sy use kr raha hon aur pora analysis kiya ha
Reverse current stop karnay k liye bridge kis tariqay sey lagatay hain us mai tu 4 points hotay hai 2 for AC and 2 for DC..
Please guide thank you@@AsadAli-ej9vz
@@MuhammadImran-uq9rc input aap AC wali 2 pins py lagain gy aur DC wali 2 pins sy aap output agay circuit m laga dain gy. Ab AC wali pins sy current agay jaye ga par reverse nhe ho sakay ga, due diodes in bridge rectifier. Sorry for late response.
واپڈا شیرنگ سے وولٹ پینل کی طرف بھی خلے جاتے ہیں
To is Liye double bridge k use kr rhy hn
@@solarinnovation040 جی استاد محترم ۔ ایک برج والے انوٹر لگائے ہیں تو انکا بل بہت زیادہ ایا ۔ جب وولٹ پینل کی طرف گیے ہیں تو یونٹ بھی گرے ہیں۔ پھر واپڈذ شیرنگ کا کنیکشن ختم کر دیا۔
Jis sy many inverter Liya , wo kehta ha PV ki supply pr bridge lagany sy processor khrab hota hai, wo asa kiun keh raha hai??? Please help
Can you share video of installing bridge at PV supply
th-cam.com/video/OvgfJqYtzrM/w-d-xo.html
I think pv input py bridge use krny sy kch ni ho ha
Yai tu apki video dekh kr poocha tha uss sy, but he warned me not to use it, could you share some test video on it . Kiya koi voltage drop ya variation atti hai supply mai. Ya modify hota hai current , ya ampere mai farad perta hai???
You think nhi ? Confirm it please@solarinnovation040
After rectification dc voltage will be 320vDC not 220
For best performance of this system your pv on load voltage should be greater then 330vDC
How bridge can I increase 220v ac into 320 v dc
Rectification MN voltages up ksy hn gy
@@solarinnovation040 Ac cycle ki lower peak wave b dc mn convert ho jatibhai full bridge rectification mn… try it…. Vdc=230Vac/0.707rms
earth breaker trip hu jata ha wapda ka-----
fail
اگر میرے پاس یہ برجز 100 ایمپئر والی موجود ہے اور میں وہ استعمال کروں تو ٹھیک رہے گا یہ لازمی ہے کہ 30 یا 60 ایمپئر ہی استعمال کریں
As u wish 100 amps bhi use kr skty hn
100 Amp ziyada behtar ha, magar expensive paray ga. 50 Amp walay kafi cheap mil jatay hain
Moghy 7kw me chye asa he mil jay ga kya
Can we convert our old pwm inverter to mppt with load sharing?
Or add WAPDA load sharing option in PWM ?
And which additional components are needed ?
Kindly make a video on it
Thanks
JazakAllah
Which type of inverter are u using?
PWM 2.2kw
Plz sir aka wattsap number chaye.plz
Am from sahiwal