Torque setting INTELLI BERNARD CONTROLS

แชร์
ฝัง
  • เผยแพร่เมื่อ 20 ต.ค. 2024
  • BERNARD CONTROLS, Electric actuator expert.
    INTELLI+® is an intuitive and intelligent integrated
    control which offers key benefits to end users:
    • Non-intrusive settings
    • Intuitive interface with local LCD display
    and easy-to-use menu
    • Accurate information with absolute sensors,
    which constantly measure the position and
    torque of the valve
    • Increased security with constant selfmonitoring,
    ESD, Partial Stroke Test (PST),
    Alarms indication, signaling continuity...
    • Preventive maintenance: INTELLI+®
    continuously monitors its components as well
    as the actuator status and measures some
    important valve parameters. It provides users
    with a great deal of information to help with
    system diagnosis, aid in scheduling their valves
    preventative maintenance and maximize
    process availability by reducing maintenance
    downtime. INTELLI+® permanently monitors
    the required torque necessary to operate the
    valve, memorizing these torque values
    generated during the last open and close
    operations.
    • Infra-red/Bluetooth communication with PC
    and tablet via INTELLISOFT software to collect
    data, implement settings/configuration

ความคิดเห็น • 15

  • @boiguacci4373
    @boiguacci4373 ปีที่แล้ว

    Thank you

  • @soufianeboutadjine3863
    @soufianeboutadjine3863 2 ปีที่แล้ว

    Hello, I would like to ask a question. I have a bernerd valve that has an alarm on shut down which is an exclamation mark

  • @dicksonjatau1778
    @dicksonjatau1778 10 หลายเดือนก่อน

    When the light is off will the valve automatically shuts down

    • @scottliu4097
      @scottliu4097  7 หลายเดือนก่อน

      the light is powered by main power supply. so when main power supply is shut down, electric actuator can't move any more.

  • @soufianeboutadjine3863
    @soufianeboutadjine3863 2 ปีที่แล้ว

    J'ai un problème avec la vanne de régulation Bernerd pouvez vous m'aider

  • @김수영-i5g5w
    @김수영-i5g5w 4 ปีที่แล้ว +1

    good

  • @alexjofra
    @alexjofra 3 ปีที่แล้ว

    How set position stx40

  • @chrisurb901
    @chrisurb901 7 ปีที่แล้ว

    como puedo regresar los valores por defaull al actuador ya que me genrea una alarma y el porcentaje de la valvula esta 546??

  • @petergreen8783
    @petergreen8783 3 ปีที่แล้ว

    Good day, I have STX-6 I cannot log in into the menu using red and blue knobs, someone habit both local and remote activation. How can I open it to get access into the menu

    • @soufianeboutadjine3863
      @soufianeboutadjine3863 2 ปีที่แล้ว

      Hello, I would like to ask a question. I have a bernerd valve that has an alarm on shut down which is an exclamation mark

  • @R945-l6f
    @R945-l6f 3 ปีที่แล้ว

    What to do if a lock symbol appear on display and nothing can access

    • @soufianeboutadjine3863
      @soufianeboutadjine3863 2 ปีที่แล้ว

      Hello, I would like to ask a question. I have a bernerd valve that has an alarm on shut down which is an exclamation mark

    • @R945-l6f
      @R945-l6f 2 ปีที่แล้ว

      @@soufianeboutadjine3863 go to alarm menu then check what alarm is that

    • @soufianeboutadjine3863
      @soufianeboutadjine3863 2 ปีที่แล้ว

      @@R945-l6f There are two alarms in opening position sensor fault and closing memory activity and position sensor fault