Choosing the Right Fuse Type for Off-Grid Solar: Expert Guide for 12V to 48V Battery Systems

แชร์
ฝัง
  • เผยแพร่เมื่อ 19 พ.ค. 2024
  • 🎁 Free diagrams: cleversolarpower.com/free-dia...
    📖 My best-selling book: cleversolarpower.com/off-grid...
    Welcome to my comprehensive guide on selecting the right fuse type for your off-grid solar power system. In this video, we delve into the world of fuses for solar setups, exploring six different kinds of fuses to ensure your system is not only efficient but also safe.
    We start with the MIDI fuse, ideal for 12 and 24V batteries, and move up to the MEGA fuse, suitable for similar voltage ranges but with higher current. For those using 12, 24, and 48V lead-acid batteries, the MRBF fuse is a perfect choice. We also cover the ANL fuse for 12 and 24V systems, the Class-T fuse for high-capacity lithium batteries up to 48V, and the NH00 fuse, a popular choice in Europe for similar applications.
    Each fuse type is broken down by its specifications, including voltage, current, ICC rating, and cost, along with recommendations for appropriate fuse holders. I will also discuss why the interrupt current capacity (ICC) is a crucial safety feature, especially in high-current scenarios typical of lithium batteries.
    Understanding the importance of battery voltage in arcing, I explain why selecting the right battery fuse is essential, particularly in high-voltage systems like 48V lithium batteries.
    For reliable and safe installations, I recommend top brands like Blue Sea Systems, Littlefuse, Bussman, Siemens, Schneider, and Victron. These brands offer the quality and reliability you need for peace of mind in your solar power setup.
    Check out the link for my recommended fuses: cleversolarpower.com/diy-sola...
    Click Like if you find this video helpful and subscribe for more insightful content.
    00:00 Introduction
    00:21 MIDI fuse
    01:39 MEGA fuse
    02:40 MRBF fuses
    03:50 ANL fuse
    04:44 Class-T fuse
    05:25 NH00 fuse
    06:35 Icc and battery voltage
    08:29 Quality fuses and breakers
    09:09 end
  • แนวปฏิบัติและการใช้ชีวิต

ความคิดเห็น • 28

  • @cleversolarpower
    @cleversolarpower  5 หลายเดือนก่อน

    🎁 Free diagrams: cleversolarpower.com/free-diagrams/
    📖 My best-selling book: cleversolarpower.com/off-grid-solar-power-simplified

  • @Aestdyfyfydyyetryuoiyfghcvb
    @Aestdyfyfydyyetryuoiyfghcvb 17 วันที่ผ่านมา +1

    If you show a example with Rate Table for ex. Class-T then this video will be perfection.

  • @rorymax8233
    @rorymax8233 13 วันที่ผ่านมา

    Interesting and valuable information, thank you.

  • @Sydneywizard
    @Sydneywizard 5 หลายเดือนก่อน +1

    Thanks for sharing and educating us with your knowledge. Its much appreciated and Merry Christmas to you.

    • @cleversolarpower
      @cleversolarpower  5 หลายเดือนก่อน +1

      Thank you! Happy holidays!

  • @davidcromapix9083
    @davidcromapix9083 หลายเดือนก่อน +1

    Thanks , very useful data.

  • @Electronzap
    @Electronzap 4 หลายเดือนก่อน +1

    Good info.

  • @2hotscottpro
    @2hotscottpro 4 หลายเดือนก่อน

    Good info.I was looking to upgrade fuses and battery shut-offs.I have cheap fuse you showed ,top left one showed in group of 4.
    My positive shut off post gets warm from 800 watts using 1500 watt heater on low.I know heat makes them fall apart.Bussman 187 series push button disconnects are $55.

    • @cleversolarpower
      @cleversolarpower  4 หลายเดือนก่อน +1

      I recommend using the disconnects switches from bluesea systems. They have less resistance. Read my article on my website about 'how to calculate power loss in a circuit'

  • @finleyandtom
    @finleyandtom 2 หลายเดือนก่อน +1

    Thanks for a super clear and informative video -
    So i am correct im thinking that with a 12v 105ah lithium battery i would be ok to fuse the main connection from the battery with a suitably sized midi or mega fuse ? 105x10 = 1050 amps max during short - IIC for a midi fuse is 5000A and 2000A for a mega

  • @npvols4321
    @npvols4321 หลายเดือนก่อน

    Please help, i have a 5000watt inverter, 4 x 200 amp hour AGM batteries , and 4 230 watt panels. I think i need a 400amp Class T fuse, but i dont know where to put it ? 12v system Please advise.

  • @fc436
    @fc436 3 หลายเดือนก่อน +1

    my 100a nh have 120kA at 500v dc icc

  • @URackADisciprine
    @URackADisciprine 4 หลายเดือนก่อน +1

    I have found Class-T fuses lower than 100A from Bussman and LittelFuse in my searches. Am looking to get an 80A (something like LittelFuse JLLN080P 80A 200KA) for a 48V LiFePO4 battery but no clue which holders will work with that. Wish they were sold as a pair.

    • @cleversolarpower
      @cleversolarpower  4 หลายเดือนก่อน +1

      The holders are sold separately. Make sure you got the right one. There are different ones for different currents. I think there are two types sold by bluesea systems.

    • @URackADisciprine
      @URackADisciprine 4 หลายเดือนก่อน +2

      There are two from Blue Sea systems, they are both too large. One is for 110-200A and the other is from 225-400A. I can't find the one I need which is for 70-100A.

  • @simon359
    @simon359 4 หลายเดือนก่อน +1

    A lot of the 48 V systems I see use mega fuses, and I didn’t see what you recommended for charge controllers? 48 V system in USA

    • @cleversolarpower
      @cleversolarpower  4 หลายเดือนก่อน +2

      Some mega fuses are rated for 58V. But people copy from other setups, so they can be faulty. 58V rated mega or midi fuse for charge controllers.

  • @TheFlashmark
    @TheFlashmark หลายเดือนก่อน +1

    Why we can't use ANL fuse for 48v LifePO4 batteries pack?

    • @cleversolarpower
      @cleversolarpower  หลายเดือนก่อน +1

      The Icc rating of an ANL fuse is too low.

  • @2hotscottpro
    @2hotscottpro 2 หลายเดือนก่อน +1

    What size fuse for 920ah 48v is why I’m here.

    • @cleversolarpower
      @cleversolarpower  2 หลายเดือนก่อน +1

      You need to figure out what load you want to power for the fuse size. For the fuse type, you likely need class-t or NH if it's lithium.

    • @2hotscottpro
      @2hotscottpro 2 หลายเดือนก่อน +1

      @@cleversolarpower 6k watt inverter with Li bat

  • @ZIlberbot
    @ZIlberbot 2 หลายเดือนก่อน

    except choosing fuse 10 times more than battery capacity, there should be like a precise formula with battery voltage as well, as energy of short circuit battery or power source is Amperage x Voltage x time ....

    • @cleversolarpower
      @cleversolarpower  2 หลายเดือนก่อน

      It is not the fuse rating. It is the short circuit fuse rating, these two are totally different. As you can see on the table different voltages have different short circuit current.

  • @johntheaccountant5594
    @johntheaccountant5594 5 หลายเดือนก่อน +1

    Why can you not use an MCB instead of a fuse?

    • @cleversolarpower
      @cleversolarpower  5 หลายเดือนก่อน +1

      An MCB is more expensive than a fuse. MCB's are used in AC switchboards. In a DC circuit the fuse wil seldom trip, so that's why we use a fuse. However, and MCB is used as a disconnect between the solar panels and charge controller.

    • @johntheaccountant5594
      @johntheaccountant5594 5 หลายเดือนก่อน +1

      @@cleversolarpower when you were saying "fuse/breaker" is US$15 dollars, I was thinking that an AC MCB is US$6 and doesn't have to be replaced when it activates.