Sir now a days bentup should not be used.... So can we provide only extra top used this floating column .... Is it right or wrong ...... Givee reply as early as possible
very nice informative video. I have 1 question .. if floating column is continuing for 2 floors, then the column steel will continue for 2nd floor or will terminate at roof slab. what is the detail for this?
mashallah bahut khoob muhtram ap se bahut kuch seekhne ko milta he
thanks
Nyc 👍
Thanks 🤗
Great learning experience sir 🎉❤❤❤
So nice
Iska cutting length BBS kaise Banta hi sir ye bataye
Sir now a days bentup should not be used.... So can we provide only extra top used this floating column .... Is it right or wrong ......
Givee reply as early as possible
Agar floating column lena bhuljate toh kya usko hilti ke upar le sakte?
Sir sajjha kitna le sakta jaada se jaada
Sir mai 1 baar aapse baat karna chahta hu
Sir concrete curtain wall pr bhi video banaye
Thanks Brother, nice video...
thanks
Thank you sir.
Explain floating columns resting on cantilever beam sir
As soon as possible
thank you deepak
Welcome
Please 🙏 is there any formula to determine the slope of the crank bars supporting the floating column .
Thanks 🙏 .
Sir, in which zone of the beam the floating column which will be good in the middle or at the side.if design is not available.
As I know it must not exceed the compressed part of the beam .
Sir fer stub beam or floating coloum main kya different hai
both are same...
stub column pe jyada load nahi aata hai
lekin floating column me jyada load aata hai isliye crank bar diya jata hai
Very nice sir
Thanks for watching my video, Hafiz ji
Thank You Sir.....
welcome Yash Ji
Sir let me know the length of bend up bar
Sir taper coloum kya hote h. Taper coloum pe video bna k smjhao na
very nice informative video. I have 1 question .. if floating column is continuing for 2 floors, then the column steel will continue for 2nd floor or will terminate at roof slab. what is the detail for this?
Sir,
I have one questn .. how to make this floating column to behave like a purely axially loaded..???...is it possible practically...??
it is possible,
send me your email id, I will mail you
@@CivilEngineerDeepakKumar sagarsrd7@gmail.com
@@sagarsarda9025
ok reply you soon......
@@CivilEngineerDeepakKumar thank u sir
Send me too kbhowmick09@gmail.com
sir, centering plate par ek vedio banaye ki aap ki site par kon si plate used karte ho...
Ok
Han bahut jald hi banaunga
@@CivilEngineerDeepakKumar thank you sir
Sir....More Vedio Upoad kijiye
Ok I am trying my best to upload more videos
nice vedio #myengineeringsupport
Sir.
How to design floating column???
Can I get spreadsheet of floating column design???
thanks for watching
Sir test of bearing capacity of soil per video banaye plz
Ok Tehseen Ji....
I will make video on this topic
And thanks for suggestion
Sir, junction pe shear reinforcement ki detail kiasi hogi?
Hello Juned Ji
I will make video on this topic
(Reinforcement details of Column Drop Panel)
It may help you
Typical details me puri size mhi batao sir ji
Thanks sir
Y shaped column details a
Sir which condition floating column on site
for support of overhead tank, etc
@@CivilEngineerDeepakKumar sir can we build this floating column on 10-15 year old beam, & what type of reinforcement design should be there?
What is the difference between stub column and floating column
both are same,
but the difference in load resistance capacity
@@CivilEngineerDeepakKumar thnx sir.. 🙏
can u add the cad file
email me
Sae ap wat sap nambar day many malo mat Lani ha
Sir kya aapka mobile no mil sakta hai
watch
th-cam.com/video/oiS90F2hKEs/w-d-xo.html
Guruji mjo aaigo
thank you
Number de diye
Aap ka number do sir