How to setup microscope, chair, Table for your first surgical case- Dr Sourabh Patwardhan

แชร์
ฝัง
  • เผยแพร่เมื่อ 7 ก.ย. 2024

ความคิดเห็น • 73

  • @myrapetclinicindore
    @myrapetclinicindore 3 ปีที่แล้ว +2

    Im a vet surgeon and have been doing cataract surgeries on animals since last few years. Your tips on microscope are very useful. and other videos also on phaco are also very useful as we dont have any training centres for us here in india but learned a lot from from videos.
    thanks a lot
    and hope to visit your centre someday

  • @chaturnandy
    @chaturnandy 2 ปีที่แล้ว +1

    Very well explained sir. Not many people go into this aspect

  • @vijayshinde4283
    @vijayshinde4283 หลายเดือนก่อน

    Very nice explanation sir
    Thank you 😊

  • @ramanichandrasekharaiyer9914
    @ramanichandrasekharaiyer9914 3 ปีที่แล้ว +1

    I regularly train many veterinary ophthalmologist on cataract surgery especially Phaco, as you mentioned the importance on operating room set up is something our young beginners should concentrate. Great sharing Thanks

  • @bhukyaharish3679
    @bhukyaharish3679 10 หลายเดือนก่อน

    Thanks for video Sir nicely mentioned practical difficulties n solution before starting the surgery… while sitting on temporal side am not able to put legs freely under table , while focusing table obstructing my legs .. kindly mention how to avoid it

  • @rakeshbali7209
    @rakeshbali7209 ปีที่แล้ว

    Interesting guidance.... We want more knowledge how to prepare operation theatre for operation... And necessarily thing in O. T.... Good management for O. T... Advance tech of O. T

  • @drravikulkarnirnr3948
    @drravikulkarnirnr3948 3 ปีที่แล้ว +1

    Very nice sir... very very useful... saved it

  • @drravikulkarnirnr3948
    @drravikulkarnirnr3948 3 ปีที่แล้ว +1

    Sir, make a teaching video on Sony a7II Camera settings for surgical video recording... plz post it if u hv done it already

  • @drprabodhakumarswain3192
    @drprabodhakumarswain3192 ปีที่แล้ว +2

    thank u very much for very nice video..sir what about presbyopic glasses?? does it req to be used while doing surgery...in otherwise emmetropic eye??

    • @SourabhPatwardhanPhacoTips
      @SourabhPatwardhanPhacoTips  ปีที่แล้ว

      You dont need presbyopic spects to look through microscope, but you may need if you wish to see whats there on the assistant trolley

  • @thedge6503
    @thedge6503 ปีที่แล้ว +1

    Very informative video on this topic. What microscope magnification do you advice on Zeus’s lumera, for cataract surgery? (9x, 10 or other). Thanks in advance

  • @turgaysatc2496
    @turgaysatc2496 4 ปีที่แล้ว +1

    Nice and guiding video for beginners. Thank you.

  • @yashprabhaneurohospital
    @yashprabhaneurohospital 2 ปีที่แล้ว +1

    Mast ..Sir...nice video...step by step guidelines

  • @rohit_roars
    @rohit_roars ปีที่แล้ว

    Sir please make a video on how to hold various instruments while doing SICS.

  • @shakeebkhan4862
    @shakeebkhan4862 4 ปีที่แล้ว

    Nicely explained and very practical points indeed sir. Thank you very much.

  • @acuriousnewophthalmologist8344
    @acuriousnewophthalmologist8344 6 หลายเดือนก่อน

    Thanks for the video Sir, One doubt- In the patient position section the eye of patient is almost reaching lower end of sternum, shouldn't it be somewhere around umbilicus level for good and comfortable posture?

    • @SourabhPatwardhanPhacoTips
      @SourabhPatwardhanPhacoTips  6 หลายเดือนก่อน

      You can lower head end of ot table. Can ask patient to fold knees which makes the position more comfortable

  • @SourabhPatwardhanPhacoTips
    @SourabhPatwardhanPhacoTips  4 ปีที่แล้ว

    th-cam.com/video/UmPdXArgyPE/w-d-xo.html watch the entire video till the end for understanding phacodynamics

  • @hananeamrani5230
    @hananeamrani5230 3 ปีที่แล้ว +3

    Sir, what zoom do you use in your surgery please ?

  • @bhartiahuja2
    @bhartiahuja2 3 ปีที่แล้ว

    Very nice video for beginners
    Dear sir
    Pls elaborate on x y
    Zoom settings also
    If possible

  • @andgm5209
    @andgm5209 2 ปีที่แล้ว

    Dr can you please explain how to look for a mandibular molar in the microscope 🙏🙏🙏 some tips to have a direct view. Nice grettings Dr!

  • @mzakria53
    @mzakria53 10 หลายเดือนก่อน

    You have good table and chair from where I can get any idea of price . Is table good enough for temporal approaches

  • @devduttanayak
    @devduttanayak 4 ปีที่แล้ว +1

    Very nice 👌👌

  • @drtanveerahmed5008
    @drtanveerahmed5008 4 ปีที่แล้ว

    Small things matter the most. Thank u sir..

  • @dariusnicholson2969
    @dariusnicholson2969 4 ปีที่แล้ว +1

    Thank you.

  • @v4youv4you50
    @v4youv4you50 3 ปีที่แล้ว

    V practical tips sir thnku so. Much

  • @MultiShaay
    @MultiShaay 4 ปีที่แล้ว +1

    Excellent doctor 💪🏼💪🏼

  • @kunalkukwas6119
    @kunalkukwas6119 2 ปีที่แล้ว

    Very useful video sir, tilting lower end microscopes may loose their coaxial component leading to poor depth perception so it's not recommend for bigginers..

    • @SourabhPatwardhanPhacoTips
      @SourabhPatwardhanPhacoTips  2 ปีที่แล้ว +2

      Hello thanks.. it doesn't lose stereopsis if patients eye is in line with the tilt

  • @haidt7
    @haidt7 ปีที่แล้ว

    Very helpfull, thank sir :)

  • @laszuarniwani2144
    @laszuarniwani2144 3 ปีที่แล้ว

    Thankyou dr...maybinask? About 3 dimension of image when we use microscop . ...this morning I doneboperate but have problem when i wantnto capsulorexis i didnt see clear to make flapnthe capsul anterrior ...how to prepare about 3 dimension of image dr?

  • @kshitijparekh9374
    @kshitijparekh9374 ปีที่แล้ว

    Keeping footpedal at sufficient distance...the trolley goes away from the table.

  • @somasekhar957
    @somasekhar957 ปีที่แล้ว

    Super useful

  • @Aragon17E
    @Aragon17E 4 ปีที่แล้ว +1

    Can you please make videos on phacodynamics, please!

    • @SourabhPatwardhanPhacoTips
      @SourabhPatwardhanPhacoTips  4 ปีที่แล้ว +2

      There are 2 videos on phacodynamics thinking process in my playlist. I will add some more soon.

  • @mathildeotsasso6315
    @mathildeotsasso6315 3 ปีที่แล้ว

    Thank you very much Sir

  • @pushkarpudasaini8287
    @pushkarpudasaini8287 4 ปีที่แล้ว +1

    I am not an Ophthalmologist but have started to use surgical microscope in my practice recently. No matter how much I try to adjust my IPD Im unable to get a single vision. Is it due to inexperience or refractive error or something else??

    • @enigma4604
      @enigma4604 ปีที่แล้ว

      Me too, have you got a solution?

  • @laszuarniwani2144
    @laszuarniwani2144 3 ปีที่แล้ว

    And how to make the field of ligt more bigger dr?

  • @naturefuture4485
    @naturefuture4485 3 ปีที่แล้ว

    Sir which is the best ophthalmic microscope budget friendly

  • @shubhrat
    @shubhrat 3 ปีที่แล้ว

    Thank you sir !

  • @user-ix8kn8qg4e
    @user-ix8kn8qg4e ปีที่แล้ว

    Sir when ever I sit on microscope there is always difference between clearity on screen n under microscope..whatever i focused under microscope that's comfortable for me that's not show clear on screen. Ipd set gud .Why this happens not getting understand.pls help

    • @SourabhPatwardhanPhacoTips
      @SourabhPatwardhanPhacoTips  ปีที่แล้ว

      1) you can try focusing using adapter of camera after you have focused under microscope at higher zoom
      2) you might be accommodating, thats why focus keeps changing

  • @amitgreatful
    @amitgreatful 4 ปีที่แล้ว +1

    Sir, nice video....I usually operate on IPD 69 with glass on as I am comfortable with that but my IPD on autoref and manually is 65.....then why I need 69 IPD in microscope... thanks for reply

    • @SourabhPatwardhanPhacoTips
      @SourabhPatwardhanPhacoTips  4 ปีที่แล้ว +3

      Sometimes the eyepieces are set wrongly so actual distance may be different than what is noted on the ipd scale of microscope. Thats very common with older microscopes or if the eye piece assembly was opened at some point of time
      Other thing is eyes are generally more comfortable in slight divergence, particularly if you have mild convergence insufficiency.
      Newer higher end microscopes also have broader field of view through eye pieces (larger diameter) so that allows some flexibility in ipd ..so even if you have set ipd +/- 2 mm you may be able to do surgery.. but its best to have perfect ipd set

    • @amitgreatful
      @amitgreatful 4 ปีที่แล้ว

      @@SourabhPatwardhanPhacoTips sir, that means myopes and increasing age surgeons will set higher IPD as compared to IPD measured on autoref or manually as these surgeons has convergence weaknesses

    • @SourabhPatwardhanPhacoTips
      @SourabhPatwardhanPhacoTips  4 ปีที่แล้ว +1

      Not necessarily amit. The difference is not huge in normal persons.normal surgeons continue to have good convergence. convergence weakness is disorder and can be treated.

  • @laszuarniwani2144
    @laszuarniwani2144 3 ปีที่แล้ว

    My problem cause i operate in another hospital ..have long time not operate with
    This microscop...before i operate in another hospital is nothing problem ..
    i can operate compfortable .

  • @krishnamarfatia7567
    @krishnamarfatia7567 4 ปีที่แล้ว

    Sometimes the Instrument trolley gets stuck to the Phaco footswitch preventing full pressing of phaco pedal. That is also one thing to take care of. Specially during Right eye surgery

  • @arundesai9006
    @arundesai9006 4 ปีที่แล้ว

    Sir I have - 0.75 cylinder in one eye other eye is emmetrope, i am not comfortable with both with glasses and without glasses, but without glasses depth perception is not good, what best I can do operate comfortably.

    • @SourabhPatwardhanPhacoTips
      @SourabhPatwardhanPhacoTips  4 ปีที่แล้ว

      Check your IPD and convergence capacity with synaptophore or RAF ruler. It may be because of convergence insufficiency

    • @SourabhPatwardhanPhacoTips
      @SourabhPatwardhanPhacoTips  4 ปีที่แล้ว

      Also if you are stressed during surgery your accommodation may increase and can lead to headache or blurry vision.

  • @poonamjuneja7911
    @poonamjuneja7911 3 ปีที่แล้ว

    Sir
    I m a first year PG in Ophthalmology
    I am not getting binocular single vision in my wet lab practice. I checked my ipd its 62mm and working on same bt still not getting it... i m a myopic either with glasses or lenses i m not getting it sir.
    Really stressed please help me out sir??

    • @eyedocnikhil
      @eyedocnikhil 3 ปีที่แล้ว

      Change microscope... Most wet lab microscopes are pathetic..

  • @eyedocnikhil
    @eyedocnikhil 3 ปีที่แล้ว

    Sir
    Why is your microscope tilted when you have red glow and tiltable eye piece in-built in this microscope???

    • @SourabhPatwardhanPhacoTips
      @SourabhPatwardhanPhacoTips  3 ปีที่แล้ว +1

      Helps in adjusting according to height of surgeon. If i was taller i would have kept it more vertical

    • @SourabhPatwardhanPhacoTips
      @SourabhPatwardhanPhacoTips  3 ปีที่แล้ว

      Or if my ot table could go lower a bit more

    • @eyedocnikhil
      @eyedocnikhil 3 ปีที่แล้ว

      Sir
      I'm not convinced with the answer...
      Please don't mind my reply...
      You are already a tall surgeon. I'm bothered because such a costly microscope doesn't give perfect ergonomics to all height surgeons... Zeiss tiltable is more than 180 so can actually look up and operate without tilting objective....

    • @SourabhPatwardhanPhacoTips
      @SourabhPatwardhanPhacoTips  3 ปีที่แล้ว

      :-) for good ergonomics the neck position should be straight upright. If it is flexed or extended, surgeon will get Musculoskeletal problems in long run. Since i operate for long hours ,i dont want to keep my neck extended or flexed. I maintain primary position. If i had low height table, i might be able to keep objective straight, but unfortunately with wheels its height is a bit more than what i wish.
      Also with height,surgeons may have slightly shorter upper body even if they are tall, so it varies from person to person. The tilt function is for adapting for that. I have Leica m822 as well, it also needs some adjustments like this.
      I am using invertetube here, so you will find that its a bit longer than regular 0-180 , but i have adjusted to that too. 😉

    • @eyedocnikhil
      @eyedocnikhil 3 ปีที่แล้ว

      Ok sir.. Agree with you... Got to know few more points today... Thank you

  • @nagabhushanrudrappa3706
    @nagabhushanrudrappa3706 4 ปีที่แล้ว

    Sir who is the distributor for surgiline chair unit

  • @yanbil9478
    @yanbil9478 ปีที่แล้ว

    Sir are they any différences between ophthalmic microscope and ENT microscope ?

  • @paroskar
    @paroskar 4 ปีที่แล้ว

    Which chair are you using? Contact no. and make please? Any other good options?

  • @SourabhPatwardhanPhacoTips
    @SourabhPatwardhanPhacoTips  4 ปีที่แล้ว

    th-cam.com/video/zSARIk-MVB4/w-d-xo.html phacodynamics